EN 14792:2017
(Main)Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
This European Standard specifies the standard reference method (SRM) based on the chemiluminescence principle for the determination of the nitrogen oxides (NOx) in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system, as well as the analyser.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on this measurement method. It applies for periodic monitoring and for the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes.
This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of prEN 14793.
This European standard has been validated during field tests on waste incineration, co-incineration and large combustion installations and on a recognized test-bench. It has been validated for sampling periods of 30 min in the range of 0 mg/m3 to 1 300 mg/m3 of NO2 for large combustion plants and 0 mg/m3 to 400 mg/m3 of NO2 for waste incineration, according to emission limit values (ELV) laid down in the Directive 2010/75/EC.
The ELV for NOx (NO + NO2) in EU directives are expressed in mg/m3 of NO2 on a dry basis, at a specified value for oxygen and at reference conditions (273 K and 101,3 kPa).
NOTE The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex F.
Emissionen aus stationären Quellen - Bestimmung der Massenkonzentration von Stickstoffoxiden - Standardreferenzverfahren: Chemilumineszenz
Diese Europäische Norm legt das Standardreferenzverfahren (SRM) auf Basis des Chemilumineszenz-Verfahrens zur Bestimmung der Stickstoffoxide (NOx) in Abgasen, die aus Abgaskanälen in die Atmosphäre emittiert werden, fest. Es beinhaltet die Einrichtungen zur Probenahme und zur Probengasaufbereitung sowie das Analysegerät.
Diese Europäische Norm legt zu bestimmende Verfahrenskenngrößen und Mindestanforderungen fest, die von portablen automatischen Messeinrichtungen (P AMS) auf Basis dieses Messverfahrens eingehalten werden müssen. Sie gilt für wiederkehrende Messungen und für die Kalibrierung oder Überprüfung von automatischen Messeinrichtungen (AMS), die aus gesetzgeberischen oder anderen Gründen stationär an einem Abgaskanal installiert sind.
Diese Europäische Norm legt Anforderungen zum Nachweis der Gleichwertigkeit von Alternativverfahren (AM) mit dem Standardreferenzverfahren (SRM) durch Anwendung der EN 14793:2017 fest.
Diese Europäische Norm wurde in Feldversuchen an Abfallverbrennungsanlagen, Mitverbrennungsanlagen und Großfeuerungsanlagen sowie an einem anerkannten Prüfstand validiert. Sie wurde mit Probenahmedauern von 30 min für NOx-Konzentrationen im Bereich von 0 mg/m3 bis 1 300 mg/m3 für Großfeuerungsanlagen und im Bereich von 0 mg/m3 bis 400 mg/m3 für Abfallverbrennungsanlagen, jeweils gemessen als NO2, entsprechend den in der Richtlinie 2010/75/EU geforderten Emissionsgrenzwerten (ELV) validiert.
In den EU-Richtlinien wird der Grenzwert für NOx (NO + NO2) gemessen als NO2 in Milligramm je Kubikmeter (mg/m3) für trockenes Gas bei einem Bezugssauerstoffgehalt und Normbedingungen (273 K und 101,3 kPa) angegeben.
ANMERKUNG Die Einzelheiten der Anlagen, die Bedingungen bei den Feldversuchen und die Werte der Wiederhol- und der Vergleichpräzision im Feld werden in Anhang A aufgeführt.
Emissions de sources fixes - Détermination de la concentration massique des oxydes d'azote - Méthode de référence normalisée : chimiluminescence
La présente Norme européenne spécifie la méthode de référence normalisée (SRM) basée sur le principe de chimiluminescence pour la détermination des oxydes d'azote (NOx) des effluents gazeux émis dans l'atmosphère par les conduits et cheminées. Elle inclut le système de prélèvement et de conditionnement du gaz ainsi que l'analyseur.
La présente Norme européenne spécifie les caractéristiques devant être déterminées et les critères de performance devant être remplis par les systèmes de mesurage fondés sur cette méthode de mesurage. Elle s'applique à la surveillance périodique et à l'étalonnage ou au contrôle des systèmes de mesurage automatisés (AMS, Automatic Measuring Systems) installés à demeure sur une cheminée, à des fins réglementaires ou à d'autres fins.
La présente Norme européenne spécifie les critères permettant de démontrer l'équivalence entre une méthode « alternative » et la méthode de référence normalisée par l'application du prEN 14793.
La présente Norme européenne a été validée au cours d'essais sur site pratiqués sur des installations destinées à l'incinération des déchets, à la coincinération et sur de grandes installations de combustion ainsi que sur un banc d'essai reconnu. Elle a été validée pour des périodes de prélèvement de 30 min, dans la gamme comprise entre 0 mg/m3 et 2 000 mg/m3 de NO2 pour de grandes installations de combustion et entre 0 mg/m3 à 400 mg/m3 of NO2 pour l'incinération des déchets, conformément aux valeurs limites d'émission (VLE) spécifiées dans la Directive 2010/75/CE.
Les VLE des Directives UE pour NOx (NO + NO2) sont exprimées en mg/m3 de NO2 sur sec, à une valeur spécifiée de l'oxygène et dans les conditions de référence (273 K et 101,3 kPa).
NOTE Les caractéristiques des installations, les conditions des essais sur site et les valeurs de répétabilité et de reproductibilité sur site sont indiquées à l'Annexe F.
Emisije nepremičnih virov - Določevanje masne koncentracije dušikovih oksidov - Standardna referenčna metoda: kemiluminiscenca
Ta evropski standard določa standardno referenčno metodo (SRM) na podlagi kemoluminiscence za določanje dušikovih oksidov (NOx) v dimnih plinih, ki prehajajo v ozračje iz vodov in odvodnikov. Vključuje sistem za vzorčenje in kondicioniranje plinov ter tudi analizator.
Ta evropski standard določa lastnosti in merila zmogljivosti, ki jih morajo izpolnjevati merilni sistemi na podlagi te merilne metode. Uporablja se za redno spremljanje in kalibracijo ali nadzor avtomatskih merilnih sistemov (AMS), ki so trajno nameščeni na odvodnik, in sicer za zakonske ter druge namene.
Ta evropski standard določa merila za prikaz enakovrednosti alternativne metode standardni referenčni metodi z uporabo standarda prEN 14793.
Ta evropski standard je bil potrjen med preskusi sežiganja odpadkov, sosežiga in velikih kurilnih naprav na terenu ter na ustrezni preskusni mizi. Potrjen je bil za 30-minutna obdobja vzorčenja v razponu od 0 mg/m3 do 1300 mg/m3 NO2 za velike kurilne naprave in od 0 mg/m3 do 400 mg/m3 NO2 za sežig odpadkov glede na mejne vrednosti emisij (ELV), opredeljene v Direktivi 2010/75/ES.
Mejne vrednosti emisij za NOx (NO + NO2) v direktivah EU so izražene v mg/m3 NO2 na suhi osnovi pri podani vrednosti kisika in referenčnih pogojih (273 K in 101,3 kPa).
OPOMBA: Lastnosti naprav, pogoji med preskusi na terenu ter vrednosti ponovljivosti in reprodukcije na terenu so podani v dodatku F.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Emissionen aus stationären Quellen - Bestimmung der Massenkonzentration von Stickstoffoxiden - Standardreferenzverfahren: ChemilumineszenzEmissions de sources fixes - Détermination de la concentration massique des oxydes d'azote - Méthode de référence normalisée : chimiluminescenceStationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence13.040.40Stationary source emissionsICS:Ta slovenski standard je istoveten z:EN 14792:2017SIST EN 14792:2017en,fr,de01-marec-2017SIST EN 14792:2017SLOVENSKI
STANDARDSIST EN 14792:20061DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14792
January
t r s y ICS
s uä r v rä v r Supersedes EN
s v y { tã t r r wEnglish Version
Stationary source emissions æ Determination of mass concentration of nitrogen oxides æ Standard reference methodã chemiluminescence Emissions de sources fixes æ Détermination de la concentration massique des oxydes d 5azote æ Méthode de référence normalisée ã chimiluminescence
Emissionen aus stationären Quellen æ Bestimmung der Massenkonzentration von Stickstoffoxiden æ Standardreferenzverfahrenã Chemilumineszenz This European Standard was approved by CEN on
t x September
t r s xä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s v y { tã t r s y ESIST EN 14792:2017
European foreword . 5 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 7 4 Symbols and abbreviations . 13 4.1 Symbols . 13 4.2 Abbreviated terms . 14 5 Principle . 14 5.1 General . 14 5.2 Measuring principle . 14 6 Description of the measuring system . 15 6.1 General . 15 6.2 Sampling and sample gas conditioning system . 16 6.2.1 Sampling probe . 16 6.2.2 Filter . 17 6.2.3 Sample gas line . 17 6.2.4 Sample gas conditioning system . 17 6.2.5 Sample gas pump . 18 6.2.6 Secondary filter . 18 6.2.7 Flow controller and flow meter . 18 6.3 Analyser equipment . 18 6.3.1 General . 18 6.3.2 Converter . 19 6.3.3 Ozone generator . 19 6.3.4 Reaction chamber . 19 6.3.5 Optical filter . 19 6.3.6 Photomultiplier tube . 20 6.3.7 Ozone removal . 20 7 Performance characteristics of the SRM . 20 8 Suitability of the measuring system to the measurement task . 21 9 Field operation . 22 9.1 Measurement planning . 22 9.2 Sampling strategy. 22 9.2.1 General . 22 9.2.2 Measurement section and measurement plane . 22 9.2.3 Minimum number and location of measurement points . 22 9.2.4 Measurement ports and working platform . 22 9.3 Choice of the measuring system . 23 9.4 Setting of the measuring system on site . 23 9.4.1 General . 23 9.4.2 Preliminary zero and span check, and adjustments . 23 9.4.3 Zero and span checks after measurement . 24 SIST EN 14792:2017
Validation of the method in the field . 28 A.1 General . 28 A.2 Characteristics of installations . 28 A.3 Repeatability and reproducibility in the field . 29 A.3.1 General . 29 A.3.2 Repeatability . 30 A.3.3 Reproducibility . 31 Annex B (informative)
Sampling and conditioning configurations . 32 Annex C (normative)
Determination of conversion efficiency . 33 C.1 General . 33 C.2 First method: cylinder gases for calibration . 33 C.3 Second method: gaseous phase titration . 33 Annex D (informative)
Examples of different types of converters . 35 D.1 Quartz converter . 35 D.2 Low temperature converter (molybdenum) . 35 D.3 Stainless steel converter . 35 Annex E (informative)
Calculation of the uncertainty associated with a concentration expressed for dry gas and at an oxygen reference concentration . 36 E.1 Uncertainty associated with a concentration expressed on dry gas . 36 E.2 Uncertainty associated with a concentration expressed at a oxygen reference concentration . 38 Annex F (informative)
Example of assessment of compliance of chemiluminescence method for NOx with requirements on emission measurements . 40 F.1 General . 40 F.2 Elements required for the uncertainty determinations . 40 F.2.1 Model equation . 40 F.2.2 Combined uncertainty . 41 F.2.3 Expanded uncertainty . 41 F.2.4 Determination of uncertainty contributions in case of rectangular distributions . 43 F.2.5 Determination of uncertainty contributions by use of sensitivity coefficients . 44 F.3 Example of an uncertainty calculation. 44 F.3.1 Site specific conditions . 44 SIST EN 14792:2017
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.