This document describes a method for the sampling and measurement of mercury of both vapour and solid phases on stationary source flue gas streams. Mercury generally exists as elemental (Hg0) and oxidized (Hg2+) forms, both in the vapour and solid phases in flue gases. The vapour-phase (gaseous) mercury is captured either isokinetically or non-isokinetically with a gold amalgamation trap after removing solid-phase (particulate) mercury with a filter. Because gold amalgamation trap captures only ...view more

    • sale 15% off
    • Standard
      35 pages
      English language
    • sale 15% off
    • Draft
      35 pages
      English language
    • sale 15% off
    • Draft
      34 pages
      French language
    • sale 15% off
    • Draft
      27 pages
      English language

This European Standard specifies a manual method for the determination of the concentration of fluorinated compounds expressed in HF. Two cases are presented:
- first case: the measurand is the concentration of hydrofluoric acid and gaseous and bound to particulates fluorides,
- second case: the measurand is the concentration of hydrofluoric acid and gaseous fluorides.
Three analytical techniques are proposed: ionometry, spectrophotometry and ion-exchange chromatography.
This European Standa...
view more

    • sale 10% off
    • Technical specification
      71 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      74 pages
      English language
    • e-Library read for
      1 day

This European Technical Specification specifies the standard reference method (SRM) for the measurement of carbon dioxide (CO2) based on the Infrared (IR) absorption principle. It includes the sampling and the gas conditioning system, and allows the determination of the CO2 in flue gases emitted to the atmosphere from ducts and stacks.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS...
view more

    • sale 10% off
    • Technical specification
      34 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical specification
      35 pages
      English language
    • e-Library read for
      1 day

This Standard contains specifications for active sampling of bioaerosols from exhaust air flowing through a defined cross-section of a stack. It defines general principles that have to be taken into account during an isokinetic sampling campaign for bioaerosols by bubbling the exhaust air through a specific impinge designed for emission measurements.
In the Standard the application with culturable organisms is specified but the same principle might be applicable for other analysis methods (e.g....
view more

    • sale 10% off
    • Standard
      57 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This document specifies the quality assurance and quality control procedures related to automated dust arrestment plant monitors.
This document applies to two types of instruments commonly used for dust arrestment plant control purposes:
— filter dust monitors that are configured in mass concentration units (e.g. mg/m3) and is used for dust arrestment control purposes;
— filter leakage monitors that indicate a change in the emission levels or a change in the magnitude of the dust pulses creat...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      20 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the performance requirements on data acquisition and handling systems (DAHS) regarding implementation of the procedures defined in EN 17255-1 including
— data acquisition;
— data processing;
— data storage;
— data output;
— generation of reports;
— system functions;
— data security;
— documentation.
This European Standard supports the requirements of EN 14181 and legislation such as the IED and E-PRTR. It does not preclude the use of additional features ...
view more

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      21 pages
      English language
    • e-Library read for
      1 day

EN-ISO 21904-4 specifies two methods for establishing the minimum air volume flow rate. One method is dedicated for use with captor hoods, nozzles and slot nozzles with a ratio of slot length to hose diameter of 8:1 or less. The other method is dedicated for use with on-gun extraction devices.These methods are not applicable to down draught tables.

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      16 pages
      English language
    • e-Library read for
      1 day

ISO 21904-1 defines the general requirements for ventilation equipment used to capture and separate fumes generated by welding and allied processes, e.g. arc welding and thermal cutting.This document also specifies the test data to be marked on the capture devices.It applies to the design and manufacture of parts of the equipment including hoods for welding, ducting, filter units, air movers, systems that inform of unsafe operation and workplace practices to ensure safe working with regard to ex...view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

EN-ISO 21904-2 specifies a method for testing equipment for the separation of welding fume in order to determine whether its separation efficiency meets specified requirements.The method specified does not apply to testing of filter cartridges independent of the equipment in which they are intended to be used.This document applies to equipment that is manufactured after its publication.

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for testing equipment for the separation of welding fume in order to determine whether its separation efficiency meets specified requirements.
The method specified does not apply to testing of filter cartridges independent of the equipment in which they are intended to be used.
This document applies to equipment that is manufactured after its publication.
NOTE General ventilation systems are excluded from the Scope of ISO 21904-1.

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      18 pages
      English language
    • e-Library read for
      1 day

This document defines the general requirements for ventilation equipment used to capture and separate fumes generated by welding and allied processes, e.g. arc welding and thermal cutting.
This document also specifies the test data to be marked on the capture devices.
It applies to the design and manufacture of parts of the equipment including hoods for welding, ducting, filter units, air movers, systems that inform of unsafe operation and workplace practices to ensure safe working with regard...
view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      28 pages
      English language
    • e-Library read for
      1 day

This document specifies the fundamental structure and the most important performance characteristics of automated measuring systems for carbon monoxide (CO), carbon dioxide (CO2) and oxygen (O2) to be used on stationary source emissions. This document describes methods and equipment for the measurement of concentrations of these gases. The method allows continuous monitoring with permanently installed measuring systems of CO, CO2 and O2 emissions. This international standard describes extractive...view more

    • sale 15% off
    • Standard
      52 pages
      English language
    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies a manual method of measurement including sampling and different analytical methods for the determination of the mass concentration of ammonia (NH3) in the waste gas of industrial plants, for example combustion plants or agricultural plants. All compounds which are volatile at the sampling temperature and produce ammonium ions upon dissociation during sampling in the absorption solution are measured by this method, which gives therefore the volatile ammonia content of the ...view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      51 pages
      English language
    • e-Library read for
      1 day

This document specifies procedures for establishing quality assurance for automated measuring systems (AMS) installed on industrial plants for the determination of the concentration of greenhouse gases in flue and waste gas and other flue gas parameters. This part of ISO 14385 specifies the following: - a procedure to maintain and demonstrate the required quality of the measurement results during the normal operation of an AMS, by checking that the zero and span characteristics are consistent wi...view more

    • sale 15% off
    • Standard
      32 pages
      English language
    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

This document specifies the procedures for establishing quality assurance for automated measuring systems (AMS) installed on industrial plants for the determination of the concentration of greenhouse gases in flue and waste gas and other flue gas parameters. This part of ISO 14385 specifies a procedure to calibrate the AMS and determine the variability of the measured values obtained by an AMS, which is suitable for the validation of an AMS following its installation. This part of ISO 14385 is d...view more

    • sale 15% off
    • Standard
      35 pages
      English language
    • sale 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day

This document specifies the fundamental structure and the most important performance characteristics of automated measuring systems for carbon monoxide (CO), carbon dioxide (CO2) and oxygen (O2) to be used on stationary source emissions. This document describes methods and equipment for the measurement of concentrations of these gases. The method allows continuous monitoring with permanently installed measuring systems of CO, CO2 and O2 emissions. This international standard describes extractive...view more

    • sale 15% off
    • Standard
      52 pages
      English language
    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

This document specifies a manual method of measurement including sampling and different analytical methods for the determination of the mass concentration of ammonia (NH3) in the waste gas of industrial plants, for example combustion plants or agricultural plants. All compounds which are volatile at the sampling temperature and produce ammonium ions upon dissociation during sampling in the absorption solution are measured by this method, which gives the volatile ammonia content of the waste gas....view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      51 pages
      English language
    • e-Library read for
      1 day

This document specifies the use of FTIR spectrometry for determining the concentrations of individual volatile organic compounds (VOCs) in waste gases from non-combustion processes. The method can be employed to continuously analyse sample gas which is extracted from ducts and other sources. A bag sampling method can also be applied, if the compounds do not adsorb on the bag material, and is appropriate in cases where it is difficult or impossible to obtain a direct extractive sample. The princi...view more

    • sale 15% off
    • Standard
      32 pages
      English language

This document specifies a manual method of measurement including sampling and different analytical methods for the determination of the mass concentration of ammonia (NH3) in the waste gas of industrial plants, for example combustion plants or agricultural plants. All compounds which are volatile at the sampling temperature and produce ammonium ions upon dissociation during sampling in the absorption solution are measured by this method, which gives the volatile ammonia content of the waste gas....view more

    • sale 15% off
    • Standard
      45 pages
      French language
    • sale 15% off
    • Standard
      44 pages
      English language

This European Standard specifies the conversion of raw data from an automated measuring system (AMS) to reported data by a data acquisition and handling system (DAHS). This specification includes:
- requirements for the handling of data,
- requirements for the reporting of data,
- calculation procedures required.
The main items covered by this European Standard are given by, but not limited to raw data acquisition, raw data validation, data correction and data averaging.
This European Stand...
view more

    • sale 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day