Abstract

ISO 1628-3:2010 defines particular conditions for determining the reduced viscosity (also known as viscosity number) and intrinsic viscosity of polyethylenes and polypropylenes at 135 °C in dilute solution.
The viscosity of polymer solutions may be affected by additives present in the sample. The value of a reduced viscosity determined by this method may therefore be unreliable if the sample contains fillers or other additives.

Status
Not Published
Publication Date
05-Dec-2027
Technical Committee
CEN/TC 249 - Plastics
Drafting Committee
CEN/TC 249 - Plastics
Current Stage
4060 - Closure of enquiry - Enquiry
Start Date
08-Sep-2026
Due Date
08-Sep-2026
Completion Date
08-Sep-2026

Buy Documents

Draft

prEN ISO 1628-3:2026

English language (14 pages)
Preview
Preview
e-Library read for
×1 day

prEN ISO 1628-3 is the draft standard for determining the reduced viscosity, also called viscosity number, and intrinsic viscosity of polyethylenes and polypropylenes in dilute solution using capillary viscometers. It is aimed at laboratories, polymer producers, and quality teams that need a controlled way to compare PE and PP materials at elevated temperature. The document specifies the solvent, sample preparation, test methods, calculation steps, and reporting items needed to make the result usable in practice.

What does prEN ISO 1628-3 specify?

prEN ISO 1628-3 specifies how to measure the viscosity behaviour of polyethylenes and polypropylenes in dilute solution at elevated temperature, with the main scope covering 135 °C to 160 °C. It organizes the work from scope and references through principle, solvent, apparatus, sample preparation, procedure, result calculation, and test report.

The document is structured in Clauses 1 to 10:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Terms and definitions
  • Clause 4 Principle
  • Clause 5 Solvent
  • Clause 6 Apparatus
  • Clause 7 Test sample
  • Clause 8 Procedure
  • Clause 9 Expression of results
  • Clause 10 Test report

What are the key requirements of prEN ISO 1628-3?

Sample, solvent, and temperature control

Clause 1 limits the method to polyethylenes and polypropylenes, and warns that fillers or additives can affect the solution viscosity. In practice, that means the method is best suited to clean polymer materials, not highly filled compounds.

Clause 4 states that these polymers do not dissolve at room temperature in known solvents, so dissolution and testing must be done at elevated temperature without precipitation. That matters because any precipitation changes the concentration and makes the result invalid.

Clause 5 sets decahydronaphthalene as the reference solvent for the manual efflux time method and allows chlorinated solvents such as 1,2-dichlorobenzene and 1,2,4-trichlorobenzene. The solvent must be stabilized with antioxidant and filtered, so the lab has to control oxidation as well as temperature.

Method A and Method B

Clause 4.2 defines the efflux time method: the laboratory measures the flow time of the solvent and the polymer solution in an Ubbelohde viscometer, then calculates reduced viscosity and intrinsic viscosity from those times and the known concentration. This is the classic manual route when a viscometer setup is available.

Clause 4.3 defines the differential pressure method: the laboratory measures differential pressure across two capillaries, one for solvent and one for polymer solution, and calculates the same viscosity results. This gives an alternative procedure for automated instruments and changes the way the flow signal is collected.

Clause 6 sets the apparatus for each method. For the efflux time method it specifies Ubbelohde viscometers, thermostatic baths, a timer, balance, shaker, flask, pipette, and filter funnel. For the differential pressure method it requires matched capillaries held at the same temperature, with larger capillaries for PE-UHMW or PP-UHMW when needed.

Concentration, preparation, and reporting

Clause 8 gives the concentration choices and preparation steps. For the efflux time method, the solution concentration is selected so the solution-to-solvent efflux time ratio stays in the stated range, and if the viscosity is unknown the method starts from a low concentration. For the differential pressure method, the concentration can be lower, and the instrument maker’s instructions guide the calculation of the injected mass or concentration.

Clause 7 requires dry powder or very small pieces. For manufactured articles, the standard allows either testing the whole article as a homogenized grind or testing surface and interior separately. That is important when the surface has a different history from the core.

Clause 9 gives the calculation of reduced viscosity and intrinsic viscosity and says to round the values to the nearest whole number. It also notes that precision is not established from interlaboratory data, so the method should be used carefully for disputes or strict specification work.

Clause 10 requires the report to identify the method, solvent, temperature, sample treatment, whether the solution was filtered, the result values, deviations, and unusual observations. In practice, this is what makes the test traceable and repeatable.

What terms does prEN ISO 1628-3 define?

  • Reduced viscosity - the main calculated flow property from the test, reported in millilitres per gram and also called viscosity number.
  • Intrinsic viscosity - the derived viscosity value used to characterize the polymer solution at low concentration.
  • Efflux time method - the manual method based on measuring solvent and solution flow times in an Ubbelohde viscometer.
  • Differential pressure method - the alternative method based on pressure difference across solvent and solution capillaries.
  • Ubbelohde viscometer - the capillary viscometer recommended for the efflux time method.
  • Decahydronaphthalene - the reference solvent named for the manual method, with antioxidant added before use.
  • PE-UHMW / PP-UHMW - ultra-high molecular weight polyethylene and polypropylene, which may need larger capillaries and more careful dissolution.

Who uses prEN ISO 1628-3?

prEN ISO 1628-3 is used by polymer testing laboratories, quality control teams, and material developers working with polyethylene and polypropylene. It is relevant for producers checking batch consistency, laboratories comparing material grades, and buyers or specifiers who need a standardized viscosity test for incoming or outgoing material control. It also supports work on manufactured articles, especially when surface and core material may need separate assessment.

What changed in prEN ISO 1628-3 from the previous edition?

prEN ISO 1628-3 is the fourth edition and replaces the third edition. The main stated change is the addition of an alternative differential pressure method, aligned with the same change made in ISO 1628-1:2024.

Which standards are used with prEN ISO 1628-3?

  • ISO 1628-1:2024 - provides the general principles for dilute-solution viscosity testing and supports the calculation and instrument framework used here.
  • ISO 3105:1994 - gives specifications and operating instructions for the glass capillary kinematic viscometers referenced for the efflux time method.

What does the prEN ISO 1628-3 document contain?

The document contains the solvent guidance, apparatus descriptions, sample preparation rules, and step-by-step procedures for both the efflux time method and the differential pressure method. Table 1 lists recommended Ubbelohde viscometer sizes, Table 2 and Table 3 guide solution concentration selection for the two methods, and Clause 9 gives the formulas used to calculate reduced viscosity and intrinsic viscosity. It also includes the report content required to document the test in a traceable way.

Relations

Effective Date
18-Dec-2024

Buy Documents

Draft

prEN ISO 1628-3:2026

English language (14 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Smithers Quality Assessments

US management systems and product certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

prEN ISO 1628-3 is a draft published by the European Committee for Standardization (CEN). Its full title is "Plastics - Determination of the viscosity of polymers in dilute solution using capillary viscometers - Part 3: Polyethylenes and polypropylenes (ISO/DIS 1628-3:2026)". This standard covers: ISO 1628-3:2010 defines particular conditions for determining the reduced viscosity (also known as viscosity number) and intrinsic viscosity of polyethylenes and polypropylenes at 135 °C in dilute solution. The viscosity of polymer solutions may be affected by additives present in the sample. The value of a reduced viscosity determined by this method may therefore be unreliable if the sample contains fillers or other additives.

ISO 1628-3:2010 defines particular conditions for determining the reduced viscosity (also known as viscosity number) and intrinsic viscosity of polyethylenes and polypropylenes at 135 °C in dilute solution. The viscosity of polymer solutions may be affected by additives present in the sample. The value of a reduced viscosity determined by this method may therefore be unreliable if the sample contains fillers or other additives.

prEN ISO 1628-3 is classified under the following ICS (International Classification for Standards) categories: 83.080.20 - Thermoplastic materials. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN ISO 1628-3 has the following relationships with other standards: It is inter standard links to EN ISO 1628-3:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN ISO 1628-3 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 4.1 General
  • 4.2 Method A – Efflux time method
  • 4.3 Method B – Differential pressure method
  • 5 Solvent
  • 6 Apparatus
  • 6.1 Efflux time method
  • 1 P100 sintered-glass disc
  • 6.2 Differential pressure method
  • 7 Test sample
  • 8 Procedure
  • 8.1 Efflux time method
  • 8.2 Differential pressure method
  • 9 Expression of results
  • 9.1 Reduced viscosity, I
  • 9.2 Intrinsic viscosity, [η]
  • 9.3 Precision
  • 10 Test report
  • Bibliography

1 Scope

This part of ISO 1628 defines particular conditions for determining the reduced viscosity (also known as viscosity number) and intrinsic viscosity of polyethylenes and polypropylenes at elevated temperatures (135 °C – 160 °C) in dilute solution.

The viscosity of polymer solutions can be affected by fillers or additives present in the sample. The value of a reduced viscosity determined by this method can therefore be unreliable if the sample contains fillers or other additives.

NOTE Reduced viscosity is also known as the Staudinger function (J ) and intrinsic viscosity as the Staudinger

index (J ).

g

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1628-1:2024, Plastics — Determination of the viscosity of polymers in dilute solution using capillary viscometers — Part 1: General principles ISO 3105:1994, Glass capillary kinematic viscometers — Specifications and operating instructions

3 Terms and definitions

There are no terms and definitions in this document.

4 Principle

4.1 General

Ethylene polymers and isotactic polypropylenes are not soluble at room temperature in any known solvents. Precautions shall therefore be taken during the test to avoid any precipitation of polymer, which would give an incorrect solution concentration.

The dissolution and test temperatures shall be chosen with the above precautions.

4.2 Method A – Efflux time method

The times of flow of a solvent and a solution of polymer at a specified concentration in that solvent are measured at elevated temperature. The reduced viscosity and intrinsic viscosity are calculated from these measurements and from the known concentration of the solution, using an appropriate Ubbelohde viscometer.

oSIST prEN ISO 1628-3:2026 ISO/DIS 1628-3:2026(en)

4.3 Method B – Differential pressure method

The differential pressure across each of the 2 capillaries connected in series, one of them receiving the solvent having the differential pressure ∆p , the other receiving the polymer solution having the differential

pressure ∆p, are measured at elevated temperature. The reduced viscosity and intrinsic viscosity are calculated from these measurements and from the known concentration of the solution.

5 Solvent

5.1 The solution viscosity obtained by this method depends on the solvent used, although the solution viscosities of polyolefin in different solvents are correlated. The reference solvent is decahydronaphtalene which is primarily used in the manual efflux time method, while chlorinated solvents may be used and allow the application of online concentration detectors in automated instruments. 5.2 Decahydronaphthalene, analytical-reagent grade, re-distilled at a temperature not higher than 65 °C and a pressure of approximately 500 Pa; its per-oxidation shall be prevented by suitable means, for example distilling in the presence of hydro-quinone.

Immediately after re-distillation of the decahydronaphthalene, 0,3 % by mass of antioxidant shall be added to inhibit oxidation during the viscosity determination. Antioxidants which have been found satisfactory include:

  • 4,4′-thio-bis-(6-tert-butyl-3-methyl)phenol;
  • bis-(2-hydroxy-3-tert-butyl-5-methyl)phenylmethane;
  • octadecyl-3-(3′,5′-di-tert-butyl-4′-hydroxyphenyl)-n-propionate;
  • Irganox 1010: tetrakis[methylene 3-(3′,5′-di-tert-butyl-4′-hydroxyphenyl)-n-propionate]methane. Filter the solvent through a P100 sintered-glass funnel. Solvent stabilized in this way gives polymer solutions that are resistant to oxidation at 135 °C for several hours.

5.3 Chlorinated solvents, 1,2-dichlorobenzene 1,2,4-trichlorobenzene. Analytical reagent grade, re-distilled at a temperature not higher than 130 °C and a pressure of approximately 6 500 Pa.

Immediately after re-distillation, 0,03 % by mass of antioxidant shall be added to inhibit oxidation during the viscosity determination. Antioxidants which have been found satisfactory include:

  • BHT: 2,6-bis(1,1-dimethylethyl)-4-methylphenol;
  • Irganox 1010: tetrakis[methylene 3-(3′,5′-di-tert-butyl-4′-hydroxyphenyl)-n-propionate]methane. Filter the solvent with P100 sintered-glass funnel.

6 Apparatus

6.1 Efflux time method

6.1.1 Ubbelohde viscometer, preferably either size No.0B as specified in Table B.4 of ISO 3105:1994 or

size No.0a as specified in Table B.9 of ISO 3105:1994, having a nominal viscometer constant of 0,005 (mm / s)/s. These viscometers are shown in Figure 1 and Figure 2 of ISO 1628-1:2024 and the principal parameters

oSIST prEN ISO 1628-3:2026 ISO/DIS 1628-3:2026(en) are given in Table 1. Viscometer size No.1 in Table B.4 and No.I in Table B.9 of described of ISO 3105:1994 may be used provided they give equivalent results as the recommended viscometers. Table 1 — Ubbelohde viscometers recommended for the determination of the dilute-solution viscosity of polymers Nominal viscometer Inside diameter Volume Inside diameter constant of tube R of bulb C of tube P Size No.

(mm /s)/s mm (±2 %) ml (±5 %) mm (±5 %) 0B 0,005 0,46 3,0 6,0 0a 0,005 0,53 5,7 6,0 If the polymer solution needs to be filtered, the modified Ubbelohde viscometer design shown in Figure 1 or other design may be used (the essential dimensions of the modified design are the same as those of the type 0B and type 0a viscometers, but tube L has been modified to include a filter). 6.1.2 Viscometer holder, to hold the viscometer firmly in the correct position in the thermostatic bath. 6.1.3 Thermostatic bath, maintained at 135 °C ± 0,2 °C, in accordance with ISO 1628-1. 6.1.4 Thermostatic bath, maintained at 20 °C ± 0,1 °C.

6.1.5 Temperature-measuring device, in accordance with ISO 1628-1 (scale division 0,1 °C). 6.1.6 Timer, of any kind provided that it can be read to the nearest 0,1 s or better and that it operates at a rate which is constant to ±0,1 % over 15 min.

6.1.7 Analytical balance, accurate to 0,1 mg.

6.1.8 Shaker, fitted in a heating bath capable of maintaining a temperature of 150 °C ± 2 °C, for dissolving the polymer in the solvent. The shaker may be of the rotating, the reciprocating or another suitable type. NOTE Certain types of shaker are not suitable for preparation of PE-UHMW solutions. 6.1.9 Glass-stoppered flask, capacity 100 ml.

6.1.10 Graduated pipette, capacity 50 ml.

6.1.11 Filter funnel, with a P100 sintered-glass disc.

oSIST prEN ISO 1628-3:2026 ISO/DIS 1628-3:2026(en) Dimensions in millimetres Key

...