Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications

This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.
NOTE 1   Information on surface characteristics is given in Annex A.
NOTE 2   Information on the performance of roof and wall assemblies is given in Annex B.

Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen - Produktanforderungen

Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits

Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten - Specifikacije za proizvod

General Information

Status
Not Published
Current Stage
5060 - Closure of Vote - Formal Approval
Start Date
09-Oct-2015
Due Date
02-Jan-2017
Completion Date
09-Oct-2015

Relations

Buy Standard

Draft
EN 490:2012/kFprA1:2015
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2015
Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten -
Specifikacije za proizvod
Concrete roofing tiles and fittings for roof covering and wall cladding - Product
specifications
Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen -
Produktanforderungen
Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits
Ta slovenski standard je istoveten z: EN 490:2011/FprA1
ICS:
91.060.20 Strehe Roofs
91.100.30 Beton in betonski izdelki Concrete and concrete
products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
FINAL DRAFT
EN 490:2011
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
July 2015
ICS 91.100.30
English Version
Concrete roofing tiles and fittings for roof covering and wall
cladding - Product specifications
Tuiles et accessoires en béton pour couverture et bardage - Dach- und Formsteine aus Beton für Dächer und
Spécifications des produits Wandbekleidungen - Produktanforderungen
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 128.
This draft amendment A1, if approved, will modify the European Standard EN 490:2011. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 490:2011/FprA1:2015 E
worldwide for CEN national Members.

Contents
Page
Foreword .3
1 Modification to the Foreword .4
2 Modification to Clause 3, Terms and definitions .4
3 Modification to Clause 6, Evaluation of conformity .4
4 Modifications to 6.1, General .4
5 Modifications to 6.2, Type testing .4
6 Modification to 6.3, Factory production control (FPC) .5
7 Modification to Annex ZA .5

Foreword
This document (EN 490:2011/FprA1:2015) has been prepared by Technical Committee CEN/TC 128
“Concrete tiles and fittings”, the secretariat of which is held by BSI.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
1 Modification to the Foreword
Replace penultimate paragraph with:
"This amendment to EN 490:2011 implements EU Regulation no. 305/2011.".
2 Modification to Clause 3, Terms and definitions
Add:
"3.12
product type
set of representative performance levels or classes of a construction product, in relation to its essential
characteristics, produced using a given combination of raw materials or other elements in a specific
production process".
3 Modification to Clause 6, Evaluation of conformity
Change the title to:
"Assessment and verification of constancy of performance (AVCP)".
4 Modifications to 6.1, General
In the first sentence, after "European Standard", add "and with the performances declared by the
manufacturer in the declaration of performance" to read:
"The compliance of a concrete roofing tile or fitting with the requirements of this European Standard and with
the performances declared by the manufacturer in the declaration of performance (DoP) shall be
demonstrated by:".
Add to the first bullet point "determination of the product type by" to read:
"
 determination of the product type by initial type testing (ITT), and".
5 Modifications to 6.2, Type testing
In the he third paragraph following PCS values, add "demonstrating their compliance" to read:
"In respect of reaction to fire performance, if the raw materials for coating systems are supplied with a
declaration of their PCS values demonstrating their compliance, no testing for PCS is required to demonstrate
compliance with the limits given in 5.9.2.2.2.".
Add a new last paragraph:
"A manufacturer may use the results of the product type determination obtained by someone else (e.g.
by another manufacturer, as a common service to manufacturers, or by a product developer), to justify
his own declaration of performance regarding a product that is manufactured according to the same
design (e.g. dimensions) and with raw materials, constituents and manufacturing methods of the same kind.".
6 Modification to 6.3, Factory production control (FPC)
In the second paragraph, add to the end of the sentence ", if they apply to the product", to read:
"The FPC system shall include the tests identified in the relevant column in Table 2, if they apply to the
product.".
7 Modification to Annex ZA
Replace Annex ZA (including change in title) with the following:
"
Annex ZA
(informative)
Clauses of this European Standard addressing the provisions of the EU
Construction Products Regulation
ZA.1 Scope and relevant clauses
This European Standard has been prepared under the following mandates given to CEN by the European
Commission and the European Free Trade Association:
 M/121, ‘Internal and external wall and ceiling finishes’, and
 M/122, ‘Roof coverings, roof lights, roof windows and ancillary products’.
If this European standard is cited in the Official Journal of the European Union (OJEU), the clauses of
this standard, shown in this annex, are considered to meet the provisions of the relevant mandate, under
the Regulation (EU) No. 305/2011.
This annex deals with the CE marking of the concrete roofing tiles and fittings for roof covering and
wall cladding intended for the uses indicated in Table(s) ZA.1.1 to ZA.1.2 and shows the relevant clauses
applicable.
NOTE 1 In addition to any specific Clauses relating to dangerous substances contained in this European Standard,
there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation
and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction
Products Regulation, these requirements also need to be complied with, when and where they apply.
NOTE 2 National regulations on dangerous substances may require verification and declaration on release, and
sometimes content, when construction products covered by this European Standard are placed on those markets. In the
absence of European harmonized test methods, verification and declaration on release/content should be done taking into
account national provisions in the place of use. An informative database of European and national provisions on
dangerous substances is available at the Construction web site on EUROPA (accessed through
http://ec.europa.eu/enterprise/construction/cpd-ds.)
Table ZA.1.1 — Relevant clauses for roof coverings
Product: Concrete roofing tiles and fittings
Intended use: for pitched roof coverings
Essential Characteristics Clauses in this and other Regulatory Notes
European Standard(s) classes
related to essential
characteristics
Mechanical resistance 5.5 - Declared
compliance
External fire resistance 5.9.1 - Declared class
Reaction to fire 5.9.2 Classes A1 to F Declared class
Water impermeability 5.6 - Declared
compliance
Dimensional variation 5.2 - Declared
compliance
Durability 5.7 - Declared
compliance
Release of dangerous substances 5.10 - -

Table ZA.1.2 — Relevant clauses for external wall cladding and internal wall lining
Product: Concrete roofing tiles and fittings
Intended use: for external wall cladding and internal wall lining
Essential Characteristics Clauses in this and other Regulatory Notes
European Standard(s) classes
related to essential
characteristics
Mechanical resistance 5.5 - Declared
compliance
Reaction to fire 5.9.2 Classes A1 to F Declared class
Water impermeability 5.6 - Declared
compliance
Dimensional variation 5.2 - Declared
compliance
Durability 5.7 - Declared
compliance
Release of dangerous substances 5.10 - -

The declaration of the product performance related to certain essential characteristics is not required in those
Member States (MS) where there are no regulatory requirements on these essential characteristics for the
intended use of the product.
In this case, manufacturers placing their products on the market of these MS are not obliged to determine nor
declare the performance of their products with regard to these essential characteristics and the option “No
performance determined” (NPD) in the information accompanying the CE marking and in the declaration
of performance (see ZA.3) may be used for those essential characteristics.
ZA.2 Procedure for AVCP
ZA.2.1 System(s) of AVCP
The AVCP system(s) of concrete roofing tiles and fittings indicated in:
 Table ZA.1.1 in accordance with the Decision of the Commission 98/436/EC of 1998-06-22 (see OJEU
L194 of 1998-07-10), as corrected (see OJEU L278 of 1998-10-15) and amended by 2001/596/EC of 2001-
01-08 (see OJEU L209 of 2001-08-02), and
 Table ZA.1.2, in accordance with the Decision of the Commission 98/437/EC of 1998-06-30 (see OJEU
L194 of 1998-07-10), as corrected (see OJEU L278 of 1998-10-15) and amended by 2001/596/EC of 2001-
01-08 (see OJEU L209 of 2001-08-02),
are shown in Table ZA.2 for the indicated intended uses and relevant levels or classes.
Table ZA.2 — Systems of AVCP
Product(s) Intended use(s) Level(s) or class(es) AVCP systems
of performance
Roofing tiles, slates, For uses subject to reaction A1*, A2*, B* and C* 1
stones and shingles to fire regulations
A1**, A2**, B**, C**, D 3
and E
(A1 to E)***, F
See EN 13501-5 3
For uses subject to external
fire performance
F 4
ROOF
regulations
For uses subject to – –
regulations on dangerous
substances
For uses other than
– 4
specified above
Tiles, sidings, panels A1*, A2*, B* and C* 1
As internal or external
finishes in wall or ceilings
A1**, A2**, B**, C**, D 3
and E
subject to reaction to fire
regulations
(A1 to E)***, F
As internal or external
finishes in walls or ceilings,
as relevant, subject to
– –
regulations on dangerous
substances
As internal or external
finishes in walls or ceilings
– 4
for other uses mentioned in
the mandate
Product(s) Intended use(s) Level(s) or class(es) AVCP systems
of performance
* Products/materials for which a clearly identifiable stage in the production process results in an
improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of
organic material).
** Products/materials not covered by footnote (*).
*** Products/materials that do not require to be tested for reaction to fire (e.g. products/materials of Class
A1 according to Commission Decision 96/603/EC).
System 1: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.2
System 3: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.4
System 4: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.5

NOTE The products which are listed in Table ZA.2 are cited as they are in the relevant Commission Decisions .
Concrete roofing tiles and fittings belong to those families of products – Most of the products are subject to a reaction to
fire class under system 3.
The AVCP of the concrete roofing tiles and fittings in Tables ZA.1.1 to ZA.1.2 shall be according to
the AVCP procedures indicated in Tables ZA.3.1 to ZA.3.3 resulting from application of the clauses of this or
other European Standard indicated therein. The content of tasks of the notified body shall be limited to those
essential characteristics as provided for, if any, in Annex III of the rele
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.