Drain and sewer systems outside buildings

This European Standard sets out the objectives for drain and sewer systems outside buildings.  It specifies the functional requirements for achieving these objectives and the principles for strategic and policy activities relating to planning, design, installation, operation, maintenance and rehabilitation.
It is applicable to drain and sewer systems, which operate essentially under gravity, from the point where wastewater leaves a building, roof drainage system, or paved area, to the point where it is discharged into a wastewater treatment plant or receiving water.
Drains and sewers below buildings are included provided that they do not form part of the drainage system for the building.

Entwässerungssysteme außerhalb von Gebäuden

Diese Europäische Norm legt Ziele für Entwässerungssysteme außerhalb von Gebäuden fest. Sie legt Funktionsanforderungen zum Erreichen dieser Ziele fest sowie Grundsätze für Strategie und Vorgehensweise in Bezug auf Planung, Bemessung, Bau, Betrieb, Unterhalt und Sanierung.
Sie gilt für Entwässerungssysteme, welche hauptsächlich als Freispiegelsysteme betrieben werden, von dem Punkt an, wo das Abwasser das Gebäude bzw. die Dachentwässerung verlässt oder in einen Straßenablauf fließt, bis zu dem Punkt, wo das Abwasser in eine Kläranlage oder einen Vorfluter eingeleitet wird.
Abwasserleitungen und -kanäle unterhalb von Gebäuden sind hierbei eingeschlossen, solange sie nicht Bestandteil der Gebäudeentwässerung sind.

Réseaux d'évacuation et d'assainissement à l'extérieur des bâtiments

La présente Norme européenne définit les objectifs des réseaux d’évacuation et d’assainissement à l’extérieur des bâtiments. Elle spécifie les prescriptions de fonctionnement permettant d’atteindre ces objectifs ainsi que les principes des activités stratégiques et politiques liées à la planification, à la conception, à l’installation, au fonctionnement, à l’entretien et à la réhabilitation.
Elle s’applique aux réseaux d’évacuation et d’assainissement, principalement les réseaux gravitaires, à partir du point où les eaux usées quittent un bâtiment, un système d’évacuation de toiture ou une surface revêtue, jusqu’au point où elles se déversent dans une station d’épuration ou un milieu récepteur aquatique.
Les branchements et collecteurs situés sous des bâtiments sont inclus, à condition qu’ils ne fassent pas partie du réseau d’évacuation du bâtiment.

Sistemi za odvod odpadne vode in kanalizacijo zunaj zgradb

General Information

Status
Withdrawn
Publication Date
22-Jan-2008
Withdrawal Date
25-Apr-2017
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
26-Apr-2017

Relations

Buy Standard

Standard
EN 752:2009
English language
110 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2009
1DGRPHãþD
SIST EN 752-1:1996
SIST EN 752-2:1996
SIST EN 752-3:1996
SIST EN 752-4:1998
SIST EN 752-5:1998
SIST EN 752-6:1998
SIST EN 752-7:1998
Sistemi za odvod odpadne vode in kanalizacijo zunaj zgradb
Drain and sewer systems outside buildings
Entwässerungssysteme außerhalb von Gebäuden
Réseaux d'évacuation et d'assainissement a l'extérieur des bâtiments
Ta slovenski standard je istoveten z: EN 752:2008
ICS:
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 752
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2008
ICS 93.030 Supersedes EN 752-1:1995, EN 752-2:1996, EN 752-
3:1996, EN 752-4:1997, EN 752-5:1997, EN 752-6:1998,
EN 752-7:1998
English Version
Drain and sewer systems outside buildings
Réseaux d'évacuation et d'assainissement à l'extérieur des Entwässerungssysteme außerhalb von Gebäuden
bâtiments
This European Standard was approved by CEN on 24 November 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2008 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 752:2008: E
worldwide for CEN national Members.

Contents Page
Foreword.7
1 Scope.10
2 Normative references.10
3 Terms and definitions .11
4 Objectives.19
4.1 General.19
4.2 Public Health and Safety.20
4.3 Occupational Health and Safety.20
4.4 Environmental Protection.20
4.5 Sustainable Development.20
5 Requirements.21
5.1 Functional Requirements.21
5.1.1 Introduction.21
5.1.2 Protection from flooding.22
5.1.3 Maintainability.22
5.1.4 Protection of surface receiving waters .22
5.1.5 Protection of groundwater.22
5.1.6 Prevention of odours and toxic, explosive and corrosive gases .23
5.1.7 Prevention of noise and vibration.23
5.1.8 Sustainable use of products and materials .23
5.1.9 Sustainable use of energy .23
5.1.10 Structural integrity and design life .23
5.1.11 Maintaining the flow .23
5.1.12 Watertightness.23
5.1.13 Not endangering adjacent structures and utility services .23
5.1.14 Inputs quality.23
5.2 Determination of performance requirements for the drain and sewer system .23
6 Integrated Sewer System Management.26
6.1 Introduction.26
6.2 Investigation.27
6.2.1 Introduction.27
6.2.2 Purpose of investigation.28
6.2.3 Review of performance information .28
6.2.4 Determine the scope of the investigation .30
6.2.5 Review existing information.30
6.2.6 Inventory update.31
6.2.7 Hydraulic investigation.31
6.2.8 Environmental investigation.31
6.2.9 Structural investigation.32
6.2.10 Operational Investigation.32
6.3 Assessment.33
6.3.1 Introduction.33
6.3.2 Assessment of the hydraulic performance.33
6.3.3 Assessment of environmental impact.33
6.3.4 Assess structural condition .34
6.3.5 Assess operational performance.34
6.3.6 Compare with performance requirements .34
6.3.7 Identify unacceptable impacts .34
6.3.8 Identify causes of performance deficiencies.34
6.4 Developing the Plan .34
6.4.1 Introduction.34
6.4.2 Develop integrated solutions.35
6.4.3 Assess Solutions.38
6.4.4 Prepare action plan .39
6.5 Implementation.40
6.5.1 Introduction.40
6.5.2 Carry out work .40
6.5.3 Monitoring performance.41
6.5.4 Review performance requirements and update plan.41
7 Health and Safety Principles .41
8 Design Principles.42
8.1 General.42
8.2 Types of systems .42
8.3 Layout and profile .43
8.4 Hydraulic Design.44
8.4.1 General.44
8.4.2 Foul drains and sewers.44
8.4.3 Surface water drains and sewers .45
8.4.4 Combined drains and sewers .47
8.5 Environmental Considerations.47
8.5.1 General.47
8.5.2 Protection of surface receiving waters .49
8.5.3 Protection of Groundwater.49
8.5.4 Prevention of septicity.49
8.5.5 Combined sewer overflows and surface water treatment.50
8.5.6 Emergency overflows.50
8.6 Structural Design.50
8.6.1 Introduction.50
8.6.2 Structural design of pipelines.51
8.6.3 Structural design of other components.51
8.6.4 Materials selection.51
8.7 Operational Considerations.52
8.7.1 General.
...

Questions, Comments and Discussion