FprEN 18316
(Main)Inorganic fertilizers - Determination of the total K2O content by gravimetry and inductively coupled plasma optical emission spectrometry (ICP-OES)
General Information
- Abstract
This document specifies two different methods (Method A and B) for the determination of the content of potassium (expressed as K2O) in inorganic fertilizers. Method A specifies a gravimetric method. Method B specifies the method using inductively coupled plasma optical emission spectrometry (ICP-OES).
This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components, fertilizers, liming materials, soil improvers, growing media, inhibitors and plant biostimulants, and where inorganic fertilizers are the highest % in the blend by mass or volume, or in the case of liquid form, by dry mass.
If inorganic fertilizers are not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply.
NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
- Status
- Not Published
- Publication Date
- 03-Feb-2027
- Technical Committee
- CEN/TC 260 - Fertilizers and liming materials
- Drafting Committee
- CEN/TC 260/WG 7 - Chemical analysis
- Current Stage
- 4599 - Dispatch of FV draft to CMC - Finalization for Vote
- Start Date
- 20-Aug-2026
- Due Date
- 31-Aug-2027
- Completion Date
- 20-Aug-2026
Overview
FprEN 18316 is a draft European Standard developed by CEN (European Committee for Standardization) that specifies two analytical methods for determining the total potassium oxide (K₂O) content in inorganic fertilizers. This standard is critical for laboratories, fertilizer manufacturers, and regulatory bodies involved in the testing and compliance of fertilizing products, ensuring consistency and reliability in potassium quantification, which is essential for nutrient management and agricultural productivity.
The document outlines:
- Method A: A gravimetric method for K₂O determination.
- Method B: Utilization of inductively coupled plasma optical emission spectrometry (ICP-OES) for K₂O measurement.
Both methods are applicable to inorganic fertilizers and certain fertilizer blends, specifically where inorganic fertilizers are the major component by mass or volume.
Key Topics
Scope and Application:
- Applicable to blended fertilizing products containing fertilizers, liming materials, soil improvers, growing media, inhibitors, and plant biostimulants-provided inorganic fertilizers are the predominant component.
- If a blend consists of components in equal ratios, the user can decide which standard to apply.
- Ensures appropriate potassium analysis across a wide spectrum of fertilizer products.
Analytical Methods:
- Gravimetric Method (Method A): Involves dissolving the sample in diluted hydrochloric acid, followed by precipitation and quantitative measurement of potassium as potassium tetraphenylborate.
- ICP-OES Method (Method B): Involves sample dissolution and direct determination of potassium concentration through advanced optical emission spectrometry.
Sampling and Sample Preparation:
- Highlights the importance of representative sampling and homogeneity in test portions.
- Recommends standardized procedures for sample grinding, digestion, and filtration to minimize analytical errors.
Accuracy and Reliability:
- Notes potential variations due to matrix effects in complex fertilizer blends.
- Validation studies support the robustness and reliability of both methods, with awareness of possible interferences or unexpected results in certain blends.
Applications
FprEN 18316 brings significant value to stakeholders in the fertilizer industry and regulatory sector by:
- Supporting compliance with EU and national fertilizer regulations, including those under Regulation (EU) 2019/1009.
- Providing a harmonized testing framework for determining total K₂O, facilitating fair trade and enforcement of labeling requirements.
- Improving product quality control for fertilizer manufacturers to ensure nutrient declarations align with actual content.
- Assisting agricultural laboratories in delivering reliable potassium analysis for diverse fertilizer types and blends, supporting better nutrient management and agronomic efficiency.
- Reducing market inconsistencies by standardizing analytical practices, thus enabling more consistent product performance for end-users.
Related Standards
- EN 1482-2: Fertilizers, liming materials and inhibitors - Sampling and sample preparation – Part 2: General sample preparation provisions.
- EN 12944-1/2: Fertilizers, liming materials and inhibitors - Vocabulary (essential definitions for analytical work).
- EN 16964: Relates to sample digestion by aqua regia.
- Regulation (EU) 2019/1009: Lays out the regulatory requirements for marketing EU fertilizing products.
These standards, in combination with FprEN 18316, provide a comprehensive framework for potassium determination and quality control in inorganic fertilizers, ensuring accurate analysis and supporting the agricultural sector in Europe and beyond.
Keywords: FprEN 18316, total K2O determination, inorganic fertilizers, gravimetric method, ICP-OES, potassium content analysis, fertilizer blends, CEN standard, fertilizer quality control, EU fertilizer regulation.
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.

ECOCERT
Organic and sustainability certification.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
FprEN 18316 is a draft published by the European Committee for Standardization (CEN). Its full title is "Inorganic fertilizers - Determination of the total K2O content by gravimetry and inductively coupled plasma optical emission spectrometry (ICP-OES)". This standard covers: This document specifies two different methods (Method A and B) for the determination of the content of potassium (expressed as K2O) in inorganic fertilizers. Method A specifies a gravimetric method. Method B specifies the method using inductively coupled plasma optical emission spectrometry (ICP-OES). This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components, fertilizers, liming materials, soil improvers, growing media, inhibitors and plant biostimulants, and where inorganic fertilizers are the highest % in the blend by mass or volume, or in the case of liquid form, by dry mass. If inorganic fertilizers are not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
This document specifies two different methods (Method A and B) for the determination of the content of potassium (expressed as K2O) in inorganic fertilizers. Method A specifies a gravimetric method. Method B specifies the method using inductively coupled plasma optical emission spectrometry (ICP-OES). This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the following components, fertilizers, liming materials, soil improvers, growing media, inhibitors and plant biostimulants, and where inorganic fertilizers are the highest % in the blend by mass or volume, or in the case of liquid form, by dry mass. If inorganic fertilizers are not the highest % in the blend, the European Standard for the highest % of the blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user decides which standard to apply. NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some components or matrix interactions can affect the outcome. Validation procedures have shown that developed standard methods are robust and reliable across diverse product compositions, but possible interferences and unexpected results when analysing fertilizing product blends are possible.
FprEN 18316 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN 18316 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564, M/564 Amd 1, M/564 Amd 2. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
FprEN 18316 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2026
Anorganska gnojila - Določanje celotnega kalijevega oksida K2O
Inorganic fertilizers - Determination of the total K2O content
Anorganische Düngemittel - Bestimmung des Gesamtgehalts an K2O
Engrais inorganiques - Détermination de la teneur en K2O total
Ta slovenski standard je istoveten z: prEN 18316
ICS:
65.080 Gnojila Fertilizers
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
prEN 18316
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2026
ICS 65.080
English Version
Inorganic fertilizers - Determination of the total K2O
content
Engrais inorganiques - Détermination de la teneur en Anorganische Düngemittel - Bestimmung des
K2O total Gesamtgehalts an K2O
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 260.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 18316:2026 E
worldwide for CEN national Members.
prEN 18316:2026 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Principle . 6
4.1 Method A: Gravimetric method. 6
4.2 Method B: ICP-OES method . 7
5 Sampling and sample preparation . 7
5.1 Sampling . 7
5.2 Sample preparation . 7
5.3 Preparation of the test portion and the sample solution . 7
6 Method A: Gravimetric method. 7
6.1 Reagents . 7
6.2 Apparatus and equipment . 8
6.3 Procedure . 8
6.3.1 Preparation of the aliquot part for precipitation . 8
6.3.2 Weighing the crucible. 9
6.3.3 Precipitation . 9
6.3.4 Filtering and washing . 9
6.3.5 Drying and weighing . 9
6.3.6 Aliquot parts to be taken as samples and conversion factors . 9
6.3.7 Blank test . 10
6.3.8 Control test . 10
6.4 Calculation and expression of the result . 10
6.4.1 Dilution according to Table 1 . 10
6.4.2 Dilution different from Table 1. 10
7 Method B: ICP-OES method . 11
7.1 Reagents . 11
7.2 Apparatus and equipment . 14
7.3 Procedure . 15
7.3.1 General. 15
7.3.2 Interferences . 16
7.3.3 Preparation of the test sample and blank solution . 17
7.3.4 Preparation of the calibration standard solutions . 17
7.3.5 Measurement . 19
7.4 Calculation and expression of the results . 20
8 Precision of Method A and B . 20
8.1 Inter-laboratory study (ILS) . 20
8.2 Repeatability . 20
8.3 Reproducibility . 20
9 Test report . 21
prEN 18316:2026 (E)
Annex A (informative) Results of the inter-laboratory study . 22
Bibliography . 24
prEN 18316:2026 (E)
European foreword
This document (prEN 18316:2026) has been prepared by Technical Committee CEN/TC 260 “Fertilizers
and liming materials”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
prEN 18316:2026 (E)
Introduction
Regulation (EU) 2019/1009 [1] specifies requirements on the making available on the market of EU
fertilizing products and the specific safety and quality requirements for the defined product function
categories (PFCs). Inorganic fertilizers have been classified into PFC 1(C).
prEN 18316:2026 (E)
1 Scope
This document specifies two different methods (Method A and B) for the determination of the content of
potassium (expressed as K O) in inorganic fertilizers. Method A specifies a gravimetric method. Method
B specifies the method using inductively coupled plasma optical emission spectrometry (ICP-OES).
This document is applicable to fertilizing product blends, where the blend is a mix of at least two of the
following components, fertilizers, liming materials, soil improvers, growing media, inhibitors and plant
biostimulants, and where inorganic fertilizers are the highest % in the blend by mass or volume, or in the
case of liquid form, by dry mass.
If inorganic fertilizers are not the highest % in the blend, the European Standard for the highest % of the
blend applies. In case a fertilizing product blend is composed of components in equal quantity, the user
decides which standard to apply.
NOTE Variations in analytical methods for fertilizing product blends can lead to differing results as some
components or matrix interactions can affect the outcome. Validation procedures have shown that developed
standard methods are robust and reliable across diverse product compositions, but possible interferences and
unexpected results when analysing fertilizing product blends are possible.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1482-2, Fertilizers, liming materials and inhibitors - Sampling and sample preparation - Part 2: General
sample preparation provisions
EN 12944-1, Fertilizers, liming materials and inhibitors — Vocabulary — Part 1: General terms
EN 12944-2, Fertilizers, liming materials and inhibitors — Vocabulary — Part 2: Terms relating to
fertilizers
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12944-1 and EN 12944-2 apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at http://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
4 Principle
4.1 Method A: Gravimetric method
The potassium in the homogenized sample to be analysed is dissolved in diluted hydrochloric acid
solution. After eliminating or fixing the substances that might interfere with the quantitative
determination, the potassium is precipitated in a slightly alkaline medium in the form of potassium
tetraphenylborate (KTPB).
A revision is under preparation. Stage at the time of preparation, prEN12944-1:2026
A revision is under preparation. Stage at the time of preparation, prEN12944-1:2026
prEN 18316:2026 (E)
4.2 Method B: ICP-OES method
The potassium in the homogenized sample to be analysed is dissolved in diluted hydrochloric acid
solution. If undissolved material remains, filtering is needed. The mass concentration of potassium is
determined by optical emission spectrometry with inductively coupled plasma (ICP-OES).
ICP-OES instruments using sequential or simultaneous optical systems and axial, radial or dual viewing
of the plasma may be used. The quantification of potassium is achieved by using linear calibration
functions.
5 Sampling and sample preparation
5.1 Sampling
Sampling is not part of the method specified in this document. Recommended sampling methods are
given in EN 1482-1 [2] and EN 1482-3 [3].
It is important that the laboratory receives a sample that is representative of both the product under
consideration and the given analysis. The sample should not have been damaged or changed during
transport or storage.
5.2 Sample preparation
Sample preparation shall be carried out in accordance with EN 1482-2.
Grinding of the sample is recommended for homogeneity reasons.
5.3 Preparation of the test portion and the sample solution
Weigh, to the nearest 0,001 g, 10 g of the prepared sample (5 g for samples with an expected mass
fraction of potassium oxide of more than 50 %). Transfer this test portion to a 600 ml beaker. In a fume
cupboard add slowly 300 ml of the hydrochloric acid solution (6.1.1), cover the beaker with a watch glass
and bring to the boil and continue boiling for 30 min. Allow to cool. Transfer quantitatively into a 1 000 ml
graduated flask, make up the volume with the hydrochloric acid solution (6.1.1), mix well and filter into
a dry beaker. Discard the first 50 ml of the filtrate.
NOTE Alternatively, aqua regia digestion according to EN 16964 can be used, if the operator ensures the
equivalence results and adjust the dilution factors in Clauses 6 and Clause 7 of this standard.
6 Method A: Gravimetric method
6.1 Reagents
Use only reagents of recognized analytical grade.
The electrical conductivity of distilled or demineralized water used in the analysis shall at least
be < 0,5 mS/m (at 25 °C).
6.1.1 Hydrochloric acid, diluted solution 1 + 9 volume fraction, c = 1 mol/l
In a fume cupboard, add 200,0 ml of concentrated hydrochloric acid (ρ = 1,18 g/ml) to about 1 600 ml
of water and cool. Dilute the solution with water to 2 000 ml and mix.
6.1.2 Formaldehyde, clear formaldehyde solution with a mass fraction of 25 % to 35 % formaldehyde.
6.1.3 Potassium chloride, w = 63,18 %, dried at (200 ± 10) °C for 2 h.
K2O
6.1.4 Sodium hydroxide solution, c = 10 mol/l.
prEN 18316:2026 (E)
Care should be taken to ensure that only potassium free sodium hydroxide is used.
Store the reagent in a plastics container.
6.1.5 Indicator solution
Dissolve 0,5 g of phenolphthalein in ethanol at 90 % and make the volume up to 100 ml.
NOTE Alternatively, an indicator solution, which is not a hazardous substance, e.g. bromothymol blue, can be
used, if the operator ensures the equivalence to the phenolphthalein solution.
6.1.6 EDTA solution, c = 0,137 mol/l.
Dissolve 4 g of the dihydrated disodium salt of ethylenediaminetetraacetic acid in water in a 100 ml
graduated flask. Make up to volume and mix.
Store the reagent in a plastics container.
6.1.7 STPB solution, c = 0,19 mol/l.
STPB
Dissolve 32,5 g of sodium tetraphenylborate in 480 ml of water, add 2 ml of the sodium hydroxide
solution (6.1.4) and 20 ml of a magnesium chloride solution (100 g of MgCl ∙6H O per litre).
2 2
Stir for 15 min and filter through a fine, ashless filter.
Store this reagent in a plastics container.
6.1.8 Liquid for washing.
Dilute 20 ml of the STPB solution (6.1.7) to 1 000 ml with water.
6.2 Apparatus and equipment
Usual laboratory apparatus and, in particular, the following:
6.2.1 Graduated flasks, capacity 1 000 ml and 2 000 ml.
6.2.2 Pipettes, capacity 10 ml, 25 ml, and 50 ml.
6.2.3 Beakers, capacity 250 ml and 600 ml.
6.2.4 Measuring cylinder, capacity 500ml.
6.2.5 Filter crucibles, porosity 5 μm to 20 μm.
6.2.6 Boiling water (steam) bath.
6.2.7 Drying oven, regulated at 120 °C ± 10 °C.
6.2.8 Desiccator.
6.2.9 Analytical balance, precision ± 0,1 mg.
6.3 Procedure
6.3.1 Preparation of the aliquot part for precipitation
Transfer by pipette an aliquot part of the filtrate (5.3) containing 25 mg to 50 mg of potassium oxide (see
Table 1) and place it in a 250 ml beaker. If required, make up to 50 ml with water.
prEN 18316:2026 (E)
To remove any interference, add 25 ml of the EDTA solution (6.1.6), several drops of the phenolphthalein
solution (6.1.5) and stir in, drop by drop, sodium hydroxide solution (6.1.4) until it turns red, then finally
add a few more drops of sodium hydroxide to ensure an excess.
Boil gently for 15 min.
NOTE Where no ammoniacal nitrogen is present in the analysed sample there is no need to boil for 15 min.
If necessary, add water to make the volume up to 75 ml.
Bring the solution to the boil, remove the beaker from the heat and add 10 ml of formaldehyde (6.1.2).
Add several drops of phenolphthalein and, if necessary, some more sodium hydroxide until a distinct red
colour appears. Cover the beaker with a watch glass and place it on a boiling water (steam) bath for
15 min.
6.3.2 Weighing the crucible
Dry the filter crucible to a constant mass (about 15 min) in the oven at 120 °C.
Allow the crucible to cool in a desiccator and then weigh it (precision ± 0,1 mg).
6.3.3 Precipitation
Remove the beaker from the boiling water (steam) bath, stir in drop-by-drop 10 ml of the STPB solution
(6.1.7). This addition should take about 2 min. Wait for at least 20 min (but no more than 30 min) before
filtering.
6.3.4 Filtering and washing
Filter under vacuum into the weighed crucible, rinse the beaker with the liquid for washing (6.1.8), wash
the precipitate three times with the liquid for washing (60 ml in all of the liquid for washing), and twice
with 5 ml to 10 ml of water.
6.3.5 Drying and weighing
Wipe the outside of the crucible with a filter paper. Place the crucible with its contents in the oven for
1,5 h at 120 °C. Allow the crucible to cool in a desiccator to ambient temperature and weigh immediately.
6.3.6 Aliquot parts to be taken as samples and conversion factors
Regarding the aliquot parts to be taken as samples, and the conversion factors, see Table 1.
Table 1 — Aliquot parts and conversion factors
Aliquot part to
K O K
2 Sample
be taken as a Conversion Conversion
for
in the in the
sample for factor F factor F’
analysis
fertilizer fertilizer
precipitation
%K O
%K
% % g ml
g KTPB
g KTPB
5 to 10 4,2 to 8,3 10 50 26,280 21,812
10 to 20 8,3 to 16,6 10 25 52,560 43,624
20 to 50 16,6 to 41,5 10 10 131,400 109,060
more than 50 more than 41,5 5 10 262,800 218,120
prEN 18316:2026 (E)
6.3.7 Blank test
For each series of determinations, carry out a blank test using only the reagents in the proportions used
in the analysis and allow for this when calculating the final result.
6.3.8 Control test
In order to obtain a control for the method of analysis, carry out a determination on an aliquot part of a
solution of potassium chloride dissolved in diluted hydrochloric acid (6.1.1), containing at the most 40 mg
of K O.
6.4 Calculation and expression of the result
6.4.1 Dilution according to Table 1
Calculate the K O content, w , as mass fraction in percent of the fertilizer according to Formula (1):
KO
(1)
w = mm− × F
( )
KO 1 2
Calculate the K content, w , as mass fraction in percent of the fertilizer according to Formula (2):
K
w= mm− × F' (2)
( )
K 12
where
m is the mass of the precipitate from the sample, in g;
m is the mass of the precipitate from the blank, in g;
F and F' are conversion factors (see Table 1).
6.4.2 Dilution different from Table 1
Calculate the K O content, , as mass fraction in percent of the fertilizer according to Formula (3):
2 w
KO
mm− × 0,1314××D 100
( )
w = (3)
KO
m
Calculate the K content, w , as mass fraction in percent of the fertilizer according to Formula (4):
K
mm− × 0,109××D 100
( )
w = (4)
K
m
where
m is the mass of the precipitate from the sample, in g;
m is the mass of the precipitate from the blank, in g;
0,1314 is the conversion factor, KTPB into K O;
0,109 is the conversion factor, KTPB into K;
D is the dilution factor;
m is the mass of the sample for analysis (test portion), in g.
prEN 18316:2026 (E)
7 Method B: ICP-OES method
7.1 Reagents
7.1.1 General
All reagents, excluding acids, but including water shall be of recognized analytical grade and they shall
have negligible concentration of the element to be determined if compared to the lowest concentration
of that element in the sample solution. Regarding the quality of water used for analytical work involving
trace analysis, the electrical conductivity shall at least be < 0,2 mS/m (at 25°C).
7.1.2 Nitric acid, substance concentration c(HNO ) ≈ 14,3 mol/l, ρ ≈ 1,4 g/ml; trace metal grade or
similar purity grade.
7.1.3 Potassium chloride (KCl), trace metal grade or similar purity grade, dried at least at
(250 ± 10)°C.
7.1.4 Potassium sulphate (K SO ), trace metal grade or similar purity grade, dried at least at
2 4
(250 ± 10) °C.
7.1.5 Potassium nitrate (KNO ).
7.1.6 Sodium sulphate (Na SO ), trace metal grade or similar purity grade, dried at least at
2 4
(250 ± 10) °C.
7.1.7 Sodium chloride (NaCl), trace metal grade or similar purity grade, dried at least at (250 ± 10)
°C.
7.1.8 Magnesium sulphate heptahydrate (MgSO⋅7 H O), trace metal grade or similar purity grade,
4 2
dried at least at (250 ± 10) °C.
7.1.9 Di-Ammonium hydrogen phosphate ((NH ) HPO ).
4 2 4
7.1.10 Ammonium sulphate ((NH ) SO ).
4 2 4
7.1.11 Calcium sulphate dihydrate (CaSO⋅2 H O).
4 2
7.1.12 Standard stock solutions for magnesium, calcium, sodium, and phosphate, concentration of
10 000 mg/l (10 g/l) for each element.
Both single-element stock solutions and multi-element stock solutions with adequate specification,
stating the acid used and the preparation technique, are commercially available. These solutions are
considered to be stable for more than one year, but in reference to guaranteed stability, the
recommendations of the manufacturer should be considered. Alternatively, the stock solutions may be
prepared by the dissolution of high purity salts.
The standard stock solutions for magnesium and calcium should have been made from Mg(NO ) and
3 2
Ca(NO ) , respectively.
3 2
7.1.13 Standard stock solutions for lithium, concentration of 1 000 mg/l (1 g/l).
Single-element stock solutions with adequate specification, stating the acid used and the preparation
technique, are commercially available. These solutions are considered to be stable for more than one
year, but in reference to guaranteed stability, the recommendations of the manufacturer should be
considered. Alternatively, the stock solutions may be prepared by the dissolution of high purity salts.
prEN 18316:2026 (E)
7.1.14 Argon, purity 99,995 % or better.
7.1.15 Calibration stock solution I, including matrix modifier for universal application.
Transfer 11,677 g of Na SO (7.1.6), 300 ml of PO standard stock solution 10 g/l (7.1.12), and 10 ml of
2 4 4
nitric acid (7.1.2) into a 1 000 ml graduated flask, dissolve with water, temper, fill up to the mark, and
homogenize.
NOTE The calibration stock solutions are important to ensure universal use of the calibration for as many
inorganic fertilizers as possible. The composition of these solutions serves on the one hand as a matrix modifier and
on the other hand to adjust the salt content in the ICP-OES measurement.
7.1.16 Calibration stock solution II, including matrix modifier for universal application.
Transfer 9,953 g of KCl (7.1.3), 200 ml of Mg standard stock solution 10 g/l (7.1.12), 100 ml of Ca
standard stock solution 10 g/l (7.1.12), and 10 ml of nitric acid (7.1.2) into a 1 000 ml graduated flask,
dissolve with water, temper, fill up to the mark, and homogenize.
7.1.17 Dilution solution.
Transfer 5,0 ml of standard stock solution for Li 1 g/l (7.1.13) and 10 ml of nitric acid (7.1.2) into a
1 000 ml graduated flask, dissolve with water, temper, fill up to the mark, and homogenize.
NOTE Alternatively, a Y-piece on the nebuliser can be used for online dosing of the internal standard (Li).
If a Y-piece on the nebuliser is used for online dosing of the internal standard (Li), the Li standard stock
solution (7.1.13) should not be added to this dilution solution. To do so, the added Li solution
concentration in the spray chamber (and plasma) should be chosen according to the intensity of the K
signal. Also, it requires a very good, proven long-term precision of the online dosing method.
7.1.18 Control sample, muriate of potash (MOP).
Transfer 9,550 g of KCl (7.1.3), 0,350 g of NaCl (7.1.7) and 0,200 g of MgSO⋅7 H O (7.1.8) into a 1 000 ml
4 2
graduated flask. Add approx. 500 ml of water, 10 ml of nitric acid (7.1.2) and mix until the salts are
dissolved. Then fill up to the mark with water, temper, and homogenize.
w = (60,33 ± 0,18) %
K2O
where
w is the target mass fraction of K O, in %, of the fertilizer.
K2O 2
NOTE The absolute standard deviation is based on empirical observation while using the method on daily
O control standard. The user of this method can set its own
basis. The ± 0,18 % is the maximum SD for the 60 % K2
appropriate acceptance limits for the control samples,
...