Fixed, vertical road traffic signs - Part 1: Fixed signs

This part of EN 12899:2001 specifies requirements for new fixed signs :
¾ non-retroreflective and retroreflective fixed signs ;
¾ non-retroreflective and retroreflective fixed signs when they are illuminated at night by external lighting luminaires ; and
¾ transilluminated signs.
The main intended use of fixed signs is for the instruction and guidance of road users on public and private land.
It defines performance limits and a range of performance classes for both sign assemblies without vertical supports and assemblies complete with vertical supports, as well as sign faces and supporting substrates, sign fixings and supports and external lighting luminaires.
Colorimetric and retroreflective properties as well as the luminance are specified. The retroreflective properties are in respect of materials based on the use of glass bead technology only. Structural requirements for signs and sign supports include performance under static and dynamic loading.
It also defines performance levels to be maintained after natural weathering exposure.
NOTE   Where tests for extremely low temperatures are required they should be in accordance with the customer's requirements.

Ortsfeste, vertikale Straßenverkehrszeichen - Teil 1: Ortsfeste Verkehrszeichen

Dieser Teil der Europäischen Norm EN 12899:2001 legt die Anforderungen an neue, ortsfeste
Verkehrszeichen fest:
¿ nicht-retroreflektierende und retroreflektierende ortsfeste Verkehrszeichen;
¿ nicht-retroreflektierende und retroreflektierende, bei Nacht von außen beleuchtete ortsfeste Ver-kehrszeichen;
¿ innenbeleuchtete Verkehrszeichen.
Benutzer öffentlicher und privater Verkehrswege werden durch die ortsfesten Verkehrszeichen infor-miert
und geführt.
Die Norm legt Mindestanforderungen und eine Reihe von Leistungsklassen für Verkehrszeichen-systeme
mit und ohne Aufstellvorrichtungen sowie für das Signalbild, den Bildträger, Schildbefestigung
und Aufstellvorrichtung sowie Beleuchtungseinrichtungen fest.
Es werden farbmetrische und retroreflektierende Eigenschaften sowie die Leuchtdichte festgelegt. Die
Anforderungen hinsichtlich Retroreflektion gelten nur für Materialien, die auf der Technologie von Glas-perlen
beruhen. Konstruktionsanforderungen an Verkehrszeichen und Verkehrszeichenhalterungen
schließen deren Eigenschaften unter statischen und dynamischen Belastungen ein.
Sie legt ebenfalls Leistungsklassen fest, die nach einer natürlichen Bewitterung eingehalten werden
müssen.
ANMERKUNG Wenn Prüfungen bezüglich extrem niedriger Temperaturen gefordert sind, sollten diese nach den
Anforderungen des Auftraggebers ausgeführt werden.
Diese Norm fordert nicht, bereits aufgestellte Verkehrszeichen auszutauschen.
Produkte und Anforderungen, die nicht Gegenstand dieser Norm sind:
a) Schilderbrücken, Kragarme und Fundamente;
b) Verkehrszeichen, die LED-Technologie oder Glasfaseroptik verwenden;
c) Wechselverkehrszeichen;
d) innenbeleuchtete, retroreflektierende Verkehrszeichen;
e) Anforderungen an die passive Schutzeinrichtung von Aufstellvorrichtungen bezüglich Fahrzeug-anprall;
f) temporäre Beschilderung.

Signaux fixes de signalisation routière verticale - Partie 1: Panneaux fixes

Cette partie de la norme européenne EN 12899:2001 spécifie les exigences pour les panneaux fixes neufs :
¾ panneaux fixes rétroréfléchissants et non rétroréfléchissants ;
¾ panneaux fixes rétroréfléchissants et non rétroréfléchissants éclairés la nuit par des luminaires d'éclairage extérieurs ; et
¾ caissons lumineux.
Les panneaux fixes sont principalement destinés à orienter et à guider les usagers de la route sur les réseaux publics et privés.
Elle définit les limites de performances et une gamme de classes de performances pour les ensembles de panneaux sans supports verticaux et les ensembles complets avec supports verticaux, ainsi que pour les faces de panneaux et les subjectiles, les fixations et supports, et les luminaires d'éclairage extérieurs.
Les propriétés de colorimétrie et de rétroréflexion, de même que la luminance, sont spécifiées.  En ce qui concerne les matériaux, les propriétés de rétroréflexion sont basées uniquement sur l'utilisation de la technologie des microbilles de verre. Les exigences mécaniques pour les panneaux et leurs supports incluent les performances sous charge statique et dynamique.
Elle définit également les niveaux de performances à maintenir après un vieillissement climatique naturel.
NOTE   Lorsque des essais à très basses températures sont requis, il convient qu'ils soient réalisés conformément aux exigences du client.

Fixed, vertical road traffic signs - Part 1: Fixed signs

General Information

Status
Withdrawn
Publication Date
11-Dec-2001
Withdrawal Date
06-Nov-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
07-Nov-2007
Completion Date
07-Nov-2007

Relations

Buy Standard

Standard
EN 12899-1:2002
English language
44 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Fixed, vertical road traffic signs - Part 1: Fixed signsFixed, vertical road traffic signs - Part 1: Fixed signsSignaux fixes de signalisation routiere verticale - Partie 1: Panneaux fixesOrtsfeste, vertikale Straßenverkehrszeichen - Teil 1: OrtsfesteVerkehrszeichenTa slovenski standard je istoveten z:EN 12899-1:2001SIST EN 12899-1:2002en93.080.30ICS:SLOVENSKI
STANDARDSIST EN 12899-1:200201-september-2002

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12899-1December 2001ICS 93.080.30English versionFixed, vertical road traffic signs - Part 1: Fixed signsSignaux fixes de signalisation routière verticale - Partie 1:Panneaux fixesOrtsfeste, vertikale Straßenverkehrszeichen - Teil 1:Ortsfeste VerkehrszeichenThis European Standard was approved by CEN on 20 January 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2001 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12899-1:2001 E

Tests for structural properties.22Annex B (informative)
Example of structural calculation based on allowable deflections.24Annex C (normative)
Test points for horizontal and vertical loads.34

or fibre optics ;c) variable message signs ;d) transilluminated retroreflective signs ;e) passive safety performance requirements of sign support structures against vehicle impact ;f) signs used for temporary purposes.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).EN 40-5, Lighting columns – Part 5 : Specification for steel lighting columns.EN 60529:1991, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989).EN 12767, Passive safety of support structures for road equipment – Requirements and test methods.EN 60598-1:1990, Luminaires – Part 1 : Specification for general requirements and tests (IEC 60598-1:1996,modified).

ISO 877, Plastics - Methods of exposure to direct weathering, to weathering using glass - Filtered daylight, and tointensified weathering by daylight using Fresnel mirrors.ISO 1459, Metallic coatings – Protection against corrosion by hot dip galvanised – Guiding principles.ISO 1461, Hot dip galvanised coatings on fabricated iron and steel articles - Specifications and test methods.ISO 6272, Paints and varnishes - Falling-weight test.ISO 9227, Corrosion tests in artificial atmospheres - Salt spray tests.CIE 15.2, Colorimetry.CIE 17.4, International lighting vocabulary.CIE 39.2, Recommendations for surface colours for visual signalling.CIE 54, Retroreflection definition and measurement.CIE 74, Roadsigns.3 Terms and definitions, symbols and abbreviationsFor the purposes of this European Standard, the symbols and abbreviations given in ISO 4 apply. The photometricterms and definitions given in CIE 17.4 and the sign descriptions given in CIE 74 also apply, together with thefollowing :3.1fixed signsign which is intended to remain fixed in position and whose supports are usually set into the ground3.2protective edgefabrication intended to reinforce the edge of the sign and to reduce the severity of personal injury in the event ofbodily impact with the sign edge3.3substratematerial used to support the non-retroreflective and retroreflective sign face materials3.4standard shape sign facescircles, triangles, squares, diamonds and octagons containing legends in accordance with the provisions of theVienna Convention

Sign fixings shall also conform to 5.3.5.5.1.5 SupportsSupports shall conform to 5.3.1 to 5.3.5 and 5.3.8. Hollow supports shall be enclosed at the top to prevent moistureingress.5.1.6 External lighting luminairesExternal lighting luminaires shall conform to EN 60598-1 and to 5.3.8.The structural design shall include the whole structure consisting of housing, support and fixings. Lamps shall beprotected by a housing against rain, wind load and other adverse outdoor conditions. Luminaire housings andluminaire panels shall conform to 5.3.8.NOTELuminaires should be mounted so as not to obscure the driver’s view of the sign face.5.1.7 Sign housings for transilluminated signsSign housings for transilluminated signs shall conform to 5.3.8 and shall be designed to ensure reliable transfer ofall static and dynamic forces to the fixing and mounting structures. The walls of the housing shall be designed tosatisfy the static requirements. Corners shall be rounded. The design shall ensure that rainwater does not run offthe housing and down the sign face.5.1.8 Base compartmentsWhere electrical apparatus is to be housed in a sign post, the post shall be fitted with a base compartmentconforming to EN 40-5. Each base compartment shall be fitted with a secure lock and shall conform to 5.3.8.5.2 Visual performance5.2.1 Colour and luminance factor5.2.1.1 Daylight appearance of non-retroreflective signsWhen tested in accordance with the procedure specified in 6.4, the chromaticity and the luminance factor
shallconform to Table 3 or Table 4.

0,15Grey0,3500,3600,3000,3100,2900,3200,3400,3700,16
0,24Black0,3850,3550,3000,2700,2600,3100,3450,395 0,03Table 4 — Chromaticity and luminance factors
Class NR2 : Non-retroreflective signs1234ColourxyxyxyxyLuminance factorWhite0,3050,3150,3350,3450,3250,3550,2950,325 0,75Yellow0,4940,5050,4700,4800,4930,4570,5220,477 0,45Red0,7350,2650,7000,2500,6100,3400,6600,340 0,07Green0,2300,4400,2600,4400,2600,4700,2300,470 0,10Blue0,1400,1400,1600,1400,1600,1600,1400,160 0,05Brown0,4670,3860,4470,3860,4470,3660,4670,3660,04
0,15Grey0,3050,3150,3350,3450,3250,3550,2950,3250,16
0,24NOTEThe limits specified in Table 3, with the exception of brown and grey, are recommended in CIE 39.2 as surfacecolours for visual signalling and; when colours deteriorate beyond these c
...