Coil coated metals - Test methods - Part 19: Panel design and method of atmospheric exposure testing

This part of EN 13523 specifies the panel design and describes the procedure for determining the resistance to outdoor exposure of an organic coating on a metallic substrate.

Bandbeschichtete Metalle - Prüfverfahren - Teil 19: Probenplatten und Verfahren zur Freibewitterung

Dieser Teil von EN 13523 legt die Gestalt der Probenplatten fest und beschreibt das Verfahren zum Bestimmen der Beständigkeit einer organischen Beschichtung auf einem metallischen Substrat bei Freibewitterung.

Tôles prélaquées - Méthodes d'essai - Partie 19: Modèles de panneaux et méthode d'essai pour les essais d'exposition à l'extérieur

La présente partie de l�EN 13523 spécifie la conception des panneaux et décrit la méthode permettant de
déterminer la résistance à l�exposition à l�extérieur d�un revêtement organique appliqué sur un subjectile métallique.

Kovine, prevlečene v svitkih - Preskusne metode - 19. del: Oblikovanje preskusnih ploščic in preskušanje z zunanjo izpostavitvijo

General Information

Status
Withdrawn
Publication Date
16-Nov-2004
Withdrawal Date
14-Jun-2011
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Jun-2011
Completion Date
15-Jun-2011

Relations

Buy Standard

Standard
EN 13523-19:2005
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 13523-19:2005
01-april-2005
.RYLQHSUHYOHþHQHYVYLWNLK3UHVNXVQHPHWRGHGHO2EOLNRYDQMHSUHVNXVQLK
SORãþLFLQSUHVNXãDQMH]]XQDQMRL]SRVWDYLWYLMR
Coil coated metals - Test methods - Part 19: Panel design and method of atmospheric
exposure testing
Bandbeschichtete Metalle - Prüfverfahren - Teil 19: Probenplatten und Verfahren zur
Freibewitterung
Tôles prélaquées - Méthodes d'essai - Partie 19: Modeles de panneaux et méthode
d'essai pour les essais d'exposition a l'extérieur
Ta slovenski standard je istoveten z: EN 13523-19:2004
ICS:
25.220.60 Organske prevleke Organic coatings
SIST EN 13523-19:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 13523-19:2005

---------------------- Page: 2 ----------------------

SIST EN 13523-19:2005
EUROPEAN STANDARD
EN 13523-19
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2004
ICS 25.220.60
English version
Coil coated metals - Test methods - Part 19: Panel design and
method of atmospheric exposure testing
Tôles prélaquées - Méthodes d'essai - Partie 19: Modèles Bandbeschichtete Metalle - Prüfverfahren - Teil 19:
de panneaux et méthode d'essai pour les essais Probenplatten und Verfahren zur Freibewitterung
d'exposition à l'extérieur
This European Standard was approved by CEN on 23 September 2004.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2004 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13523-19:2004: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 13523-19:2005
EN 13523-19:2004 (E)
Foreword
This document (EN 13523-19:2004) has been prepared by Technical Committee CEN/TC 139 “Paints and
varnishes”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by May 2005, and conflicting national standards shall be withdrawn at the latest by
May 2005.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

2

---------------------- Page: 4 ----------------------

SIST EN 13523-19:2005
EN 13523-19:2004 (E)
Introduction
In the past it has been common practice in the northern hemisphere to expose test panels at 45° facing South.
Whilst this orientation is appropriate for degradation of the organic coating, investigations have shown that it has
little bearing on the overall corrosion performance of the product when used in building applications.
For example, the 45° facing South exposure takes no account of
 overhangs which produce unwashed areas;
 sheet overlaps;
 low pitched roofing, etc.
The Outdoor Exposure Committee of European Coil Coating Association (ECCA) designed an exposure system
which aligns more closely with "real life" situations and which is the basis of this part of EN 13523
Three panel orientations are specified:
a) PANEL 1: 45° to horizontal facing South. The traditional orientation for evaluation of organic coatings: colour
change, gloss change, chalking, etc.;
b) PANEL 2: 90° to horizontal facing North, with an overhang for evaluating general corrosion on side cladding
particularly in unwashed areas;
c) PANEL 3: 5 ° to horizontal facing South. This panel which includes an overlap is principally for evaluating
general corrosion in roofing applications.
The selection of one or more panel des
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.