Abstract

This part of the European Standard defines how to calculate the energy performance indicators for road lighting installations using the calculated power density indicator (PDI) DP and the calculated annual energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during the year, even if the relevant lighting requirements change during the night or seasons.
These indicators may be used to compare the energy performance of different road lighting solutions and technologies for the same road lighting project. The energy performance of road lighting systems with different road geometries or different lighting requirements cannot be compared to each other directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as the lighting requirements. The power density indicator (DP) and annual energy consumption indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2.

Status
Not Published
Publication Date
27-Feb-2028
Current Stage
4020 - Submission to enquiry - Enquiry
Start Date
12-Nov-2026
Due Date
01-Feb-2026
Completion Date
01-Feb-2026

Buy Documents

Relations

Effective Date
07-Apr-2025

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija

ZAG inspection body for construction products, structures, and materials.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

prEN 13201-5 is a draft published by the European Committee for Standardization (CEN). Its full title is "Road lighting - Part 5: Energy performance indicators". This standard covers: This part of the European Standard defines how to calculate the energy performance indicators for road lighting installations using the calculated power density indicator (PDI) DP and the calculated annual energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during the year, even if the relevant lighting requirements change during the night or seasons. These indicators may be used to compare the energy performance of different road lighting solutions and technologies for the same road lighting project. The energy performance of road lighting systems with different road geometries or different lighting requirements cannot be compared to each other directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as the lighting requirements. The power density indicator (DP) and annual energy consumption indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2.

This part of the European Standard defines how to calculate the energy performance indicators for road lighting installations using the calculated power density indicator (PDI) DP and the calculated annual energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during the year, even if the relevant lighting requirements change during the night or seasons. These indicators may be used to compare the energy performance of different road lighting solutions and technologies for the same road lighting project. The energy performance of road lighting systems with different road geometries or different lighting requirements cannot be compared to each other directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as the lighting requirements. The power density indicator (DP) and annual energy consumption indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2.

prEN 13201-5 is classified under the following ICS (International Classification for Standards) categories: 93.080.40 - Street lighting and related equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN 13201-5 has the following relationships with other standards: It is inter standard links to EN 13201-5:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN 13201-5 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2027
Cestna razsvetljava - 5. del: Kazalniki energetske učinkovitosti
Road lighting - Part 5: Energy performance indicators
Straßenbeleuchtung - Teil 5: Energieeffizienzindikatoren
Éclairage public - Partie 5: Indicateurs de performance énergétique
Ta slovenski standard je istoveten z: prEN 13201-5
ICS:
27.015 Energijska učinkovitost. Energy efficiency. Energy
Ohranjanje energije na conservation in general
splošno
93.080.40 Cestna razsvetljava in Street lighting and related
pripadajoča oprema equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2026
ICS 93.080.40 Will supersede EN 13201-5:2015
English Version
Road lighting - Part 5: Energy performance indicators
Éclairage public - Partie 5: Indicateurs de performance Straßenbeleuchtung - Teil 5:
énergétique Energieeffizienzindikatoren
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 169.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 13201-5:2026 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms, definitions, symbols and abbreviations . 6
3.1 Terms and definitions . 6
3.2 Symbols and abbreviations . 7
3.3 Indices . 9
4 Power density indicator (PDI) . 9
4.1 Calculation of the power density indicator . 9
4.2 Average horizontal illuminance to be used for calculation of the power density
indicator . 10
4.3 System power (P) to be used for calculation of the power density indicator . 10
4.4 Area (A) to be used for calculation of the power density indicator . 11
5 Annual energy consumption Iindicator (AECI) . 11
Annex A (informative) Examples of calculation and typical values of energy performance
indicators . 13
A.1 Examples of operational profiles . 13
A.1.1 General . 13
A.1.2 Constant lighting level operational profile . 13
A.1.3 Multi-power operation . 14
A.1.4 Operation with vehicle and presence detectors . 14
A.1.5 Operation with a real time continuously adjusting of the lighting level . 15
A.2 Evaluation of traffic conditions . 16
A.3 Examples of calculation . 19
A.4 Typical values of energy performance indicators . 28
A.4.1 General . 28
A.4.2 Two-lane road for motorized traffic (road layout A) . 29
A.4.3 Road with mixed motorized and pedestrian traffic without footpath (road layout B) . 30
A.4.4 Road and footpath on the side of lighting arrangement (road layout C) . 31
A.4.5 Road and footpath on the opposite side to the lighting arrangement (road layout D) . 31
A.4.6 Road and two footpaths on both sides (road layout E) . 32
A.4.7 Road and two foothpaths on both sides separated from carriageway by grass strips
(road layout F) . 33
A.4.8 Typical values of AECI for different operational profiles . 34
A.5 Comparison of energy performance of different operational profiles and road
layouts . 35
Annex B (informative) Installation luminous efficacy . 37
B.1 General . 37
B.2 Calculation of the correction factor . 37
B.3 Calculation of the utilance . 38
B.4 Calculation of the efficiency of luminaires . 38
Annex C (informative) Lighting factor of an installation . 39
C.1 Installation lighting factor q . 39
inst
C.2 Role of q in road lighting design aimed at energy saving . 39
inst
C.3 Typical values of q . 40
inst
Annex D (informative) Presentation of energy performance indicators . 41
Bibliography . 42

European foreword
This document (prEN 13201-5:2026) has been prepared by Technical Committee CEN/TC 169 “Light and
lighting”, the secretariat of which is held by DIN.
This document is currently submitted to the enquiry.
This document will supersede EN 13201-5:2015.
Significant changes between this document and EN 13201-5:2015 are:
— the terms and definitions included in EN 12665 were deleted to avoid duplication;
— better performing tri-power operation profile replaced the bi-power profile in A.1;
— calculation example in A.2 was improved and extended by two additional lighting situations, the
examples were completed by particular values;
— added typical values of energy performance indicators D and D in A.3;
E P
— form for presentation of energy performance indicators D and D in Annex D was improved.
E P
Introduction
The purpose of this European Standard is to define energy performance indicators for road lighting
installations. The standard introduces two metrics, the power density indicator (PDI) D and the annual
P
energy consumption indicator (AECI) D that are always used together.
E
To quantify the potential savings obtainable from improved energy performance and reduced
environmental impact, it is essential to calculate both the power density indicator (D ) and the annual
P
energy consumption indicator (D ). In addition, the installation luminous efficacy (η ) can be used for
E inst
comparing the energy performances of alternative road lighting installations.
Careful choice of lighting class(es) during the design and specification phase will help to maximize energy
savings by ensuring only the necessary levels of illumination provided at the correct times and for the
minimum periods necessary. Additional guidance is given in the CEN/TR 13201-1 with regard to the
visual needs of road users, e.g. under varying traffic volumes during certain times of night or under
varying weather conditions.
When designing a road lighting installation, it is desirable to reduce overlighting to the minimum
technically obtainable while ensuring that the design criteria of EN 13201-2 are met. Overlighting can be
minimized by the careful selection of the luminaire but the specified lighting class, the designed lighting
point spacing and uniformity ratios are all determining factors of the luminous flux emitted by the
luminaire and thus the power of the luminaire required. However, this precise luminous flux might not,
in reality, exist. Where the luminous flux of the luminaire is greater than that required the designer can
by means of continuously variable control gear, compensate for this effect by reducing the luminous flux
of the luminaire to the required level resulting in lower energy consumption. The same principles and
control gear can be used to compensate for changes in luminous flux emitted throughout the lifetime of
the light sources in luminaires.
The energy levels calculated using this document are not meant to be used as a direct input for the
calculation of the load on the electrical distribution system. Such calculations are normally based on the
energy requirement derived directly from the lighting and electrical design.
Examples of operational profiles and examples of calculation of the energy performance indicators are
provided in Annex A. Typical values of energy performance indicators are provided to illustrate the
energy performance of recent technological level of luminaires and installations.
Annex B introduces the installation luminous efficacy and its factors as a measure of the influence of
various light losses and other parameters.
Lighting factor of an installation, as introduced in Annex C, can be additionally used to characterize the
energy performance of road lighting installations independently on the lighting components used. Other
factors and parameters having influence to the energy performance, such as the maintenance factor (see
CIE 154), can be recognized but are not dealt within this document.
Recommendations on presentation of the energy performance indicators are provided in Annex D.
1 Scope
This document defines how to calculate the energy performance indicators for road lighting installations
using the calculated power density indicator (PDI) D and the calculated annual energy consumption
P
indicator (AECI) D . Power density indicator (D ) demonstrates the energy needed for a road lighting
E P
installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual
energy consumption indicator (D ) determines the power consumption during the year, even if the
E
relevant lighting requirements change during the night or seasons.
These indicators may be used to compare the energy performance of different road lighting solutions and
technologies for the same road lighting project. The energy performance of road lighting systems with
different road geometries or different lighting requirements cannot be compared to each other directly,
as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as
the lighting requirements. The power density indicator (D ) and annual energy consumption indicator
P
(D ) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2.
E
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 12665, Light and lighting - Basic terms and criteria for specifying lighting requirements
EN 13201-2, Road lighting - Part 2: Performance requirements
EN 13201-3, Road lighting - Part 3: Calculation of performance
3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12665 and the following apply.
3.1.1
system power (of a lighting installation in a given state of operation)
P
total power of the road lighting installation needed to fulfil the required lighting classes as specified in
EN 13201-2 in all the relevant sub-areas, and to operate and control the lighting installation (unit: W)
3.1.2
power density indicator (of a lighting installation in a given state of operation)
PDI
D
P
value of the system power divided by the value of the product of the surface area to be lit and the
-1. −2
calculated maintained average illuminance value on this area according to EN 13201-3 (unit: W·lx m )
3.1.3
installation luminous efficacy
η
inst
minimum luminous flux needed to provide the minimum lighting level for the specified area divided by
−1
the total average power consumption of the lighting installation (unit: lm·W )
3.1.4
constant light output (of a road lighting installation)
CLO
regulation of the road lighting installation aiming at providing a constant light output from the light
sources
Note 1 to entry: This functionality aims to compensate for the light loss caused by ageing of the light sources.
3.1.5
installation lighting factor
q
inst
dimensionless factor accounting for the relation of the calculated average maintained luminance of road
surface over the calculated average maintained horizontal illuminance on this surface and the average
luminance coefficient of the r-table adopted in luminance calculation
3.1.6
lighting operation factor
c
op
dimensionless ratio between the value of AECI for the actual operational profile and the AECI for full
power operation
3.1.7
illuminance reduction factor
k
E
dimensionless ratio between the light level of the actual operational lighting class and the designed
lighting class
Note 1 to entry: The illuminance reduction factor, often managed via adaptive lighting systems, involves reducing
light levels by one lighting class or greater (for example a reduction factor of 0,8 = 80 %) for energy efficiency. When
reducing lighting levels, a “dimming curve” is used to manage the change.
3.1.8
power reduction factor for the reduced lighting level
k
P
dimensionless ratio between the reduced power at a given reduced lighting level and the full power
Note 1 to entry: The power reduction factor (PRF) quantifies how much electrical power a lighting system uses
when dimmed to a lower light output level compared to the electrical power used at the full light output level.
3.2 Symbols and abbreviations
Table 1 — Symbols and abbreviations
Symbol or
Name or description Unit
abbreviation
A Area to be lit m
Correction factor for luminance or hemispherical illuminance based
C -
L
lighting designs
c Lighting operation factor -
op
CLO Constant Light Output
−2
D Annual energy consumption indicator (AECI) Wh·m
E
Symbol or
Name or description Unit
abbreviation
-1. −2
D Power density indicator (PDI) W·lx m
P
Average maintained horizontal illuminance lx
E
E Hemispherical illuminance lx
hs
E
Minimum required average illuminance lx
min
E Calculated average maintained illuminance on the carriageway lx
R
EIR Edge illuminance ratio
f Overall maintenance factor (MF) of the lighting installation -
M
k Illuminance reduction coefficient for the reduced lighting level -
E
k Power reduction coefficient for the reduced lighting level -
P
−2
Average maintained luminance cd·m
L
−2
L Minimum required average luminance cd·m
min
LOR Light output ratio
Number of operation time periods for different levels of operational power
m -
P
n Number of sub-areas to be lit -
Number of light points associated with the lighting installation or the
n -
lp
representative section
P System power of all the luminaires designed to lit the relevant area W
Total active power of any devices not considered in the operational power
P W
ad
P but necessary for operation of the road lighting installation
P Power of light aource(s) inside the luminaire W
ls
RLO Light output ratio (LOR) of luminaires used in the lighting installation -
q Lighting factor of an installation -
inst
−1
Q Average luminance coefficient sr
o
t Duration of the operation time for a particular system power P over a year h
U Utilance of the lighting installation -
Φ Luminous flux reaching the area to be illuminated lm
A
Φ Luminous flux emitted from the light source(s) in a luminaire lm
ls
δ Detection probability coefficient -
−1
η Installation luminous efficacy lm·W
inst
−1
η Luminous efficacy of the light sources used in the installation lm·W
ls
n Number of luminaires considered in the calculation -
lu
η Power efficiency of luminaires used in the lighting installation -
P
3.3 Indices
Table 2 — Indices
Index Name or description
C Cycle path
F Footpath
FL Left footpath
FP Full power period
FR Right footpath
LN Late night period
LT Low traffic period
R Carriageway
4 Power density indicator (PDI)
4.1 Calculation of the power density indicator
Power density indicator for an area divided into sub-areas for a given state of operation shall be
calculated with the following formula:
P
D =
P
n
E ⋅ A
( ii)
∑
i=1
(1)
where
D is the power density indicator, in watt per lux per square metre;
P
P is the system power of the lighting installation used to light the relevant areas (see 4.3), in
watt;
E is the maintained average horizontal illuminance of the sub-area i determined in accordance
i
with 4.2, in lux;
A is the size of the sub-area “i” lit by the lighting installation, in square metre;
i
n is the number of sub-areas to be lit.
If the required lighting class changes during the night and/or through the seasons (for example
reductions in lighting class due to decreased traffic density, changes in the visual environment or other
relevant parameters), the power density (D ) should be calculated separately for each of the lighting
P
classes. Alternatively, where multiple lighting classes are used during the night or year the power density
(D ) may be calculated as an average over this period. The calculation shall clearly indicate the
P
assumptions used for calculation of the power density (D ) and how this value was evaluated.
P
Values of the power density indicator (D ) shall be always presented and used together with the annual
P
energy consumption indicator (D ) for assessment of the energy performance of a particular lighting
E
system.
4.2 Average horizontal illuminance to be used for calculation of the power density
indicator
For illuminance based lighting classes (C and P) the maintained average horizontal illuminance ( ) to be
E
used for the power density (D ) calculation shall be calculated according to EN 13201-3.
P
For luminance based lighting classes (M) the maintained average horizontal illuminance ( ) to be used
E
for the power density (D ) calculation shall be the average of illuminance values calculated on the same
P
grid of points which are used for the calculation of luminance in accordance with EN 13201-3.
For hemispherical illuminance based lighting classes (HS) the maintained average horizontal illuminance
( ) to be used for the power density (D ) calculation shall be the average of illuminance values calculated
E P
on the same grid of points which are used for the calculation of hemispherical illuminance in accordance
with EN 13201-3.
Some lighting installations may be over lit in terms of significantly higher lighting levels than those
required or specified. When such overlighting occurs, it should be determined if this is as a result of poor
design or as an unavoidable consequence of other requirements. From an energy efficiency and
environmental perspective corrective action should be taken to minimize any overlighting.
From an energy efficiency and environmental perspective the calculated lighting level for any lighting
installation should not exceed the required lighting level of the next higher lighting class (or not exceed
the required lighting level by 50 % in case of the highest class) without considering other design
solutions.
4.3 System power (P) to be used for calculation of the power density indicator
The system power (P) shall be calculated from the sum of the operational power of the light sources,
control gear(s) and any other electrical device(s) (lighting point control unit(s), switch(es), photoelectric
cell(s), etc.) which are directly associated with the lighting of the area to be lit and installed in order to
operate or regulate the installation. The system power (P) should be calculated for the complete lighting
installation or the representative section used during the lighting design according to the following
formula:
n
lp
P PP+
∑ k ad
k=1
(2)
where
P is the total system power of the lighting installation or its representative section, in W;
th
P is the operational power of the k lighting point (light source, gear, any other device like
k
lighting point control unit, switch or photoelectric cell and component, which are associated
with the lighting point and necessary for its operation), in W;
P is the total operational power of any devices not considered in P but necessary for the
ad k
operation of the road installation such as a remote switch or photoelectric cell, centralized
luminous flux controller or centralized management system, etc. in W.
Where the system power is calculated for a representative area the total operational power P
ad
should be proportioned according to the number of luminaires used to illuminate the area over the
total number of luminaires supplied from the devices represented by P .
ad
n is the number of lighting points associated with the lighting installation or the representative
lp
section whichever is used in the calculation.
If light sources (and other electrical devices) are operated on constant power, this power shall be used
when the system power (P) is calculated.
=
If the lighting class changes during the night and/or seasons (for example reduction in lighting class
during the night due to decreased traffic density, changes in the visual environment or other relevant
parameters), the system power (P) corresponding to the operational lighting class in that period should
be calculated.
NOTE PDI can be a single number for full time constant power operation and for 100 % dimming level in
regulated systems, or it can represent different numbers for each considered state of operation. Annex A gives
examples of calculation and Annex D gives an example of the presentation of results.
Where the luminous flux output of the light source is varied to compensate for changes in luminous flux
output throughout lifetime of the light sources (for example the light sources use constant light output
(CLO) drivers), the average system power associated with these variations should be used for the
calculation of power density (D ).
P
If the calculation for the main lighting class is based on a single calculation for a section of the road, i.e.
for a typical arrangement and spacing, then the system power (P) calculation shall include the sum of the
power of all luminaires and the electrical device(s) related to luminaires, lighting points and segments
which are inside and on the edges of the calculation area relevant to this typical arrangement, in
accordance with EN 13201-3. Annex A shows some typical examples. The number of luminaires and size
of the area shall be relevant to each other.
If the calculation is performed for an irregular shaped area, the system power (P) calculation shall include
the sum of the power of each luminaire and the electrical device(s) related to luminaires, lighting points
and segments, which are needed to light the area.
The system power (P) should not include any power associated with devices which are not used to fulfil
the lighting function, even if they are connected to the same network. Typical examples are illuminated
advertisement and festive lighting.
4.4 Area (A) to be used for calculation of the power density indicator
The area used for calculation of the power density indicator (D ) shall be identical to the area used in
P
lighting design for lighting calculation of parameters according to EN 13201-2 and described in
EN 13201-3.
If the carriageway of a road is not surrounded by other areas (for example another carriageway, footpath,
cycle path or parking areas, etc., which have their own individual specified lighting requirements) and
edge illuminance ratio (EIR) is calculated in accordance with EN 13201-2, the surrounding areas used for
calculating EIR are not included in the calculation of power density indicator.
5 Annual energy consumption Iindicator (AECI)
The annual electricity consumption of a road lighting installation depends on:
— the period of time for which lighting is provided;
— the designed and operational lighting classes specified by the relevant lighting standard for each
lighting period;
— the efficiency of the lighting installation, when providing the necessary lighting for each period;
— the way the lighting management system follows the change in visual needs of road users; and
— the parasitic energy consumption of lighting devices during the period when the lighting is not
needed.
— For comparison and monitoring of the energy performance of a lighting installation, the energy
consumption indicator shall take into account the annual accumulated energy use of road lighting
illuminating the street or public area, however actual lighting needs may vary during the year
because of the following reasons:
— seasonal variations of daylight / night time hours: this depends on the geographical location of the
area;
— changing weather conditions which influence perceived visual performance (i.e. dry or wet road
surface);
— changing traffic density on the street or public area during the night (i.e. different temporal pattern
of usage such as increased usage at “rush hour”) or following the fluctuation in social activity (i.e.
school terms, national holiday periods); and
— changing functionality of the street or public area (i.e. roads are closed for a certain period or turned
to pedestrian areas in festive seasons).
Annual energy consumption indicator (AECI) shall be calculated with the following formula:
m
Pt⋅
( )
jj
∑
j=1
D =
E
A
(3)
where
−2
D is the annual energy consumption indicator for a road lighting installation, in Wh·m ;
E
th
P is the operational power associated with the j period of operation, in W;
j
th
t is the duration of j period of operation profile when the power P is consumed, over a year,
j j
in h;
A is the size of the area lit by the same lighting arrangement, in m ;
m is the number of periods with different operational power P · m shall also consider the period
j
over which the quiescent power is consumed. This period would generally be the time when
the lighting is not operational, i.e. daylight hours and any night time period when the lighting
is not lit.
For calculation of AECI it is necessary to take into account the lighting control profile applied to lighting
system as combination of reduction coefficients and annual operation time for each of the operational
regimes and probability of motion detection, if used.
If the light output of a light source is intended to be constant, but the power consumption of this light
source (or other electrical devices) varies in time (for example if constant light output (CLO) drivers are
used), the average power consumption over the anticipated lifetime shall be included in the calculation.
The calculation shall clearly indicate the lifetime assumptions used for calculation of the average
consumption and how this value was evaluated.
Annual energy consumption indicator (D ) shall be always presented and used together with the values
E
of the power density indicator (D ) for assessment of the energy performance of a particular lighting
P
system.
NOTE Indicator D together with indicator D are a useful tool for energy monitoring in the case of remote-
E P
controlled installations.
Annex A
(informative)
Examples of calculation and typical values of energy performance
indicators
A.1 Examples of operational profiles
A.1.1 General
Typical examples of daily operational profiles for road lighting are given below. Start time and end time
of operation change throughout the year and depend on the geographical latitude and local conditions. It
is advisable that the operation of artificial lighting is correlated with illuminance from daylight with
respect to the illuminance required for a particular lighting class according to EN 13201-2. In the moment
of sunset the illuminance level is considerably high but rapidly decreases. At sunrise the situation is
reversed.
Examples of operational profiles in this annex illustrate the daily course of lighting level. Power level
needed for the calculation of energy performance is associated with lighting levels depending on the type
and power of luminaires and other factors.
NOTE 1 This annex does not deal with particular relation between lighting level and power level.
For the calculation of AECI it is necessary to sum up daily operation hours for each of the lighting levels
throughout a whole year.
NOTE 2 Parasitic power is not included in the operational profiles presented below.
A.1.2 Constant lighting level operational profile
The operational profile in Figure A.1 is typical for lighting installations with simple switching devices like
time switchers or photosensors. Luminaires operate constantly at full power throughout the night time
each day.
Key
X daily course of operation (h = hours)
Y lighting level (%)
Figure A.1 — Constant lighting level profile that results in constant full power consumption of
the lighting system
A.1.3 Multi-power operation
The multi-power operational profile (e.g. tri-power profile shown in Figure A.2) consists of two or more
time periods during the daily course when luminaires are operated at different power associated with
different lighting levels provided. Bi-power profile was typical for voltage regulation of sodium lamps in
older installations. Each of the lighting levels should be derived from lighting class according to
EN 13201-2.
Key
X daily course of operation (hours of the day)
Y lighting level (%)
Figure A.2 — Three lighting level operational profile that results in three levels of power
consumption of the lighting system
A.1.4 Operation with vehicle and presence detectors
When detectors control the lighting system, power usage reduces during periods of no detected traffic,
with luminaires also operating at reduced lighting levels. Figure A.3 illustrates a four-level lighting
profile, showing that a minimum lighting level remains during periods of no detection. The peaks are
based on sensor activity and therefore irregular. To calculate AECI, annual probability parameters for
each lighting level activated by detectors shall be assumed.

Key
X daily course of operation (hours = h
Y lighting level (%)
Figure A.3 — Four lighting level operational profile that results in four levels of power
consumption of the lighting system
A.1.5 Operation with a real time continuously adjusting of the lighting level
In order to further reduce energy consumption whilst still providing light where, when and at the level
needed, a real time measurement of the traffic flow ratio with a continuously monitoring of the adjusted
light level should be adopted.
The example of operation shown could be based for on but not restricted to weather conditions or traffic
conditions or noise sensors (the periods are variable in this case, and not based on fixed hours).
The use of real time monitoring preserves the level of safety for the road user whilst saving energy.
The lowest and the highest lighting levels should be derived from lighting class according to EN 13201-2.
The lighting level between these two lighting classes is adjusted proportionally based on the measured
traffic flow ratio. When the traffic flow ratio exceeds 100 % and for M lighting classes, the lighting class
immediately below the design class is activated.
NOTE This choice is justified by the fact that in this situation, vehicle speed is lower than the maximum allowed
and vehicle density is so high that the concept of average road surface luminance becomes practically insignificant
for visibility conditions.
Considering the traffic flow ratio of Figure A.6 an example of this type of adjusting light level is show in
Figure A.4.
Considering the traffic flow ratio of Figure A.7 an example of this type of adjusting light level is show in
Figure A.5.
Knowing the active energy absorbed by the lighting system during the annual cycles the annual energy
consumption indicator AECI is obtained by dividing these values by the area of the surface illuminated by
the lighting system, in square meters.

Key
X daily course of operation (hours
Y lighting level (%)
Z lighting class
Figure A.4 — Real time continuously adjusting lighting level operational profile considering the
traffic flow ratio of Figure A.6
Key
X daily course of operation (hours of the day)
Y lighting level (%)
Z lighting class
Figure A.5 — Real time continuously adjusting lighting level operational profile considering the
traffic flow ratio of Figure A.7
A.2 Evaluation of traffic conditions
Often the designer compares different technical solutions to adjust the lighting level of the lighting
system. This task is complex because real future traffic conditions are not known.
The traffic flow ratio is the quotient of the traffic flow rate and the maximum traffic capacity of the road
and is the best quantity for describing the traffic conditions for adjusting the lighting level of a road
lighting system.
Reference performance values of the lighting installation can be obtained considering typical behaviour
of the traffic flow ratio need to operate correctly the lighting system.
This problem can be addressed by the adoption of standardized or agreed values of the traffic flow ratio
accepted by the lighting designer and the owner of the lighting system as suitable for a specific
installation. Using these values, the performances of different technical solution can be compared.
If accurate data for the traffic flow ratio are not available, the following examples relevant to roads with
design lighting class M3 (Figure A.6) and M4 (Figure A.7) might be considered.
The function to evaluate the traffic flow ratio q (t) at a time t is shown in Formula (A.1):
t
2 34 5 6
q t=a++bt ct+ dt+ et+ ft+ gt
( )
t
(A.1)
In Formula (A.1) the time-of-day t is conventionally assumed to start at 17:00 and end after a duration of
14 h. For longer periods the hourly traffic flow ratio can be extrapolated. The values of the polynomial
coefficients a, b, c, d, e, f, g are given in Table A.1.
NOTE Formula A.1 originates from UNI 11431:2016 The source of values in Table A.6 and Table A.7 were
obtained from an evaluation of statistical data from over one million measurements taken on Italian roads.
The time range used for the application of Formula (A.1) could differ from the working period of the
lighting system. Therefore, a consensus should be obtained for the boundary of the working period.

Key
X daily course of operation (h)
Y traffic flow ratio (%)
Figure A.6 — Reference average hourly traffic flow ratio on a road with starting lighting class M3
Key
X daily course of operation (h)
Y traffic flow ratio (%)
Figure A.7 — Reference average hourly traffic flow ratio on a road with starting lighting class M4
Table A.1 — Polynomial coefficients of functions in Figure A.6 and Figure A.7
Time
t
Function Coefficient
minutes seconds
a 64,8675 64,8675
−2
b 1,294 99 2,158 32 × 10
−2 −6
c −1,325 35 × 10 −3,681 53 × 10
−5 −10
A d 4,693 20 × 10 2,172 78 × 10
−8 −15
e −7,973 70 × 10 −6,152 55 × 10
−11 −20
f 6,574 18 × 10 8,454 44 × 10
−14 −25
g −2,103 18 × 10 −4,507 85 × 10
a 41,7445 41,7445
−2
b 1,501 11 2,501 85 × 10
−2 −6
c −1,198 86 × 10 −3,330 16 × 10
−5 −10
B d 3,347 59 × 10 1,549 81 × 10
−8 −15
e −4,045 31 × 10 −3,121 38 × 10
−11 −20
f 1,818 26 × 10 2,338 30 × 10
−16 −27
g −3,257 85 × 10 −6,982 71 × 10
NOTE Function A is adopted for a road with starting lighting class M3.
Function B is adopted for a road with starting lighting class M4.
A.3 Examples of calculation
Calculation of the energy performance indicators PDI (Clause 4) and AECI (Clause 5) is additionally
explained by means of three examples shown below.
System power of the luminaires is the nominal power usually provided by luminaire manufacturer. If
calculation of energy performance is performed for a typical field between two consecutive lighting poles
according to EN 13201-3, system power is included in calculation only once. If calculation of energy
performance is performed on the entire road length or its section longer than a single field for
photometric calculation, all luminaires associated with this road section are included.
Illuminated areas can be calculated for the corresponding widths of road layout and the considered length
of the installation (length of the road, road section or spacing of luminaires). Illuminance should be
calculated for each of the areas in accordance with EN 13201-3. Areas of adjacent grass strips and strips
for calculation of the edge illuminance ratio EIR are excluded from the calculation of energy performance
indicators.
EXAMPLE 1:
In this simple case, the road layout consists only of a two lane carriageway (see Figure A.8). Lighting poles
are installed aside of the carriageway with luminaires P mounted directly on their top (without arm).
R
Lighting design is based on illuminance (P lighting class).

Figure A.8 — Situation and identification of luminaires and areas for example 1
Bi-power operational profile is depicted in Figure A.9. Lighting is operated at full power until 23:00. Then
the light level is dimmed down by 40 % (one lighting class, k = 0,60) when traffic intensity is reduced,
E
which corresponds to 37 % of power reduction (k = 0,63). At 05:00 the full power lighting level is
P
restored.
Key
X daily course of operation (h)
Y lighting level (%)
Figure A.9 — Operational profile for example 1
NOTE 1 Switching times in Figure A.9 (ON at 18:00, OFF at 06:00) depend on the day of the year, the geographical
location and how the actual lighting control system (simple timer, astronomical clock timer, photocell etc.) takes
the seasonal changes into account.
Respecting the situation in Figure A.8 and assumptions mentioned above, Formulae (1) and (3) for the
calculation of energy performance indicators become the forms:
kP⋅
PR
D =
P
kE⋅ ⋅ A
ER R
(A.2)
Pt⋅ + k ⋅ t
( )
...