IEC 60364-7-714:2011 applies to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply authority or the origin of the circuit supplying the external lighting installation exclusively. The requirements apply to, for example, lighting installations for roads, parks, gardens, places open to the public, sporting areas, illumination of monuments, floodlighting, telephone kiosks, bus shelters, advertising panels, town plans and road signs. The requirements do not apply to: - public street-lighting installations which are part of the public power grid; - temporary festoon lighting; - road traffic signal systems; - and luminaires which are fixed to the outside of a building and are supplied directly from the internal wiring of that building. This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. The major technical changes with respect to the previous edition are listed below: - clause numbering is aligned with present structure of IEC 60364; - additional protection is required in some cases of equipment incorporating lighting; - more stringent requirements regarding IP degree of protection; - introduction of particular requirements for isolation.
- Standardization document14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies lighting requirements for outdoor work places, which meet the needs for visual comfort and performance. All usual visual tasks are considered. This European Standard is not applicable for emergency lighting; see EN 1838 and EN 13032-3.
This European Standard does not specify lighting requirements with respect to the safety and health of workers at work and has not been prepared in the field of application of Article 153 of the EC treaty, although the lighting requirements, as specified in this standard, usually fulfil safety needs. Lighting requirements with respect to the safety and health of workers at work may be contained in Directives based on Article 153 of the EC treaty, in national legislation of member states implementing these directives or in other national legislation of member states.
This European Standard neither provides specific solutions, nor restricts the designer’s freedom from exploring new techniques nor restricts the use of innovative equipment.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation34 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the verification of the design of steel, aluminium, concrete and fibre reinforced polymer composite lighting columns by testing. It gives type tests and so does not cover testing for quality control purposes. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
This European Standard includes a simplified method for testing steel and aluminium lighting columns. Refer to EN 40-4 for concrete lighting columns and to EN 40-7 for fibre reinforced polymer composite lighting columns.
NOTE For a more detailed test procedure, refer to Annex D of EN 1990:2002.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this European Standard.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies design loads for lighting columns. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this document, in conjunction with Annex B of EN 40-7:2002.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the requirements for the verification of the design of steel, aluminium, concrete and fibre reinforced polymer composite lighting columns by testing. It gives type tests and so does not cover testing for quality control purposes. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard. This European Standard includes a simplified method for testing steel and aluminium lighting columns. Refer to EN 40-4 for concrete lighting columns and to EN 40-7 for fibre reinforced polymer composite lighting columns. The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this European Standard. This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies design loads for lighting columns. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard. The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this document, in conjunction with Annex B of EN 40-7:2002. This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the verification of the design of lighting columns by calculation. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard. The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this standard in conjunction with EN 40-7. This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767). The calculations used in this European Standard are based on limit state principles, where the effects of factored loads are compared with the relevant resistance of the structure. Two limit states are considered: a) the ultimate limit state, which corresponds to the load-carrying capacity of the lighting column; b) the serviceability limit state, which relates to the deflection of the lighting column in service.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60364-7-714:2011 applies to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply authority or the origin of the circuit supplying the external lighting installation exclusively. The requirements apply to, for example, lighting installations for roads, parks, gardens, places open to the public, sporting areas, illumination of monuments, floodlighting, telephone kiosks, bus shelters, advertising panels, town plans and road signs. The requirements do not apply to: - public street-lighting installations which are part of the public power grid; - temporary festoon lighting; - road traffic signal systems; - and luminaires which are fixed to the outside of a building and are supplied directly from the internal wiring of that building. This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. The major technical changes with respect to the previous edition are listed below: - clause numbering is aligned with present structure of IEC 60364; - additional protection is required in some cases of equipment incorporating lighting; - more stringent requirements regarding IP degree of protection; - introduction of particular requirements for isolation.
- Standardization document14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60364-7-714:2011 applies to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply authority or the origin of the circuit supplying the external lighting installation exclusively. The requirements apply to, for example, lighting installations for roads, parks, gardens, places open to the public, sporting areas, illumination of monuments, floodlighting, telephone kiosks, bus shelters, advertising panels, town plans and road signs. The requirements do not apply to:
- public street-lighting installations which are part of the public power grid;
- temporary festoon lighting;
- road traffic signal systems;
- and luminaires which are fixed to the outside of a building and are supplied directly from the internal wiring of that building.
This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. The major technical changes with respect to the previous edition are listed below:
- clause numbering is aligned with present structure of IEC 60364;
- additional protection is required in some cases of equipment incorporating lighting;
- more stringent requirements regarding IP degree of protection;
- introduction of particular requirements for isolation.
- Standard20 pagesEnglish and French languagesale 15% off
This document specifies lighting requirements for humans in outdoor work places, which meet the needs for visual comfort and performance of people having normal, or corrected to normal ophthalmic (visual) capacity. Usual visual tasks and the avoidance of obtrusive light are considered.
This document specifies requirements for lighting solutions for most outdoor work places and their associated areas in terms of quantity and quality of illumination. In addition, recommendations are given for good lighting practice. This document does not specify lighting requirements with respect to the safety and health of people at work and has not been prepared in the field of application of Article 153 of Treaty on the Functioning of the European Union although the lighting requirements, as specified in this document, usually fulfil safety needs.
NOTE Lighting requirements with respect to the safety and health of workers at work can be contained in Directives based on Article 153 of Treaty on the Functioning of the European Union, in national legislation of member states implementing these directives or in other national legislation of member states.
This document neither provides specific solutions, nor restricts the designers' freedom from exploring new techniques nor restricts the use of innovative equipment. The illumination can be provided by daylight, electric lighting or a combination of both.
This document is not applicable for the lighting of indoor work places and underground mining or emergency lighting. For indoor work places, see EN 12464-1 and for emergency lighting, see EN 1838 and EN 13032-3.
- Draft56 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies lighting requirements for outdoor work places, which meet the needs for visual comfort and performance. All usual visual tasks are considered. This European Standard is not applicable for emergency lighting; see EN 1838 and EN 13032-3.
This European Standard does not specify lighting requirements with respect to the safety and health of workers at work and has not been prepared in the field of application of Article 153 of the EC treaty, although the lighting requirements, as specified in this standard, usually fulfil safety needs. Lighting requirements with respect to the safety and health of workers at work may be contained in Directives based on Article 153 of the EC treaty, in national legislation of member states implementing these directives or in other national legislation of member states.
This European Standard neither provides specific solutions, nor restricts the designer’s freedom from exploring new techniques nor restricts the use of innovative equipment.
- Draft56 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with fixed external lighting installations. The requirements apply particularly to lighting installations e.g. for roads, parks, gardens, public places, sporting areas, illumination of monuments and flood lighting, and other equipment incorporating lighting such as telephone kiosks, bus shelters, advertising panels, town maps, road signs. Note: External lighting comprises luminaires, wiring system and accessories located outside buildings. [
]This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page numbers correspond to the French-language pages.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with fixed external lighting installations. The requirements apply particularly to lighting installations e.g. for roads, parks, gardens, public places, sporting areas, illumination of monuments and flood lighting, and other equipment incorporating lighting such as telephone kiosks, bus shelters, advertising panels, town maps, road signs. Note: External lighting comprises luminaires, wiring system and accessories located outside buildings.
- Standardization document6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the verification of the design of lighting columns by calculation. It applies to post top columns not exceeding 20 m height for post top lanterns and to lighting columns with brackets not exceeding 18 m height for side entry lanterns.
The calculations used in this standard are based on limit state principles, where the effects of factored loads are compared with the relevant resistance of the structure. Two limit states are considered:
a) the ultimate limit state, which corresponds to the load-carrying capacity of the lighting column;
b) the serviceability limit state, which relates to the deflection of the lighting column in service.
NOTE In following this approach, simplifications appropriate to lighting columns have been adopted, These are:
1) the calculations are applicable to circular and regular octagonal cross-sections;
2) the number of separate partial safety factors have been reduced to a minimum;
3) serviceability partial safety factors have a value equal to unity.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard.
This standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not included, this group of lighting columns will have additional requirements (see prEN 40-2).
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the verification of the design of steel, aluminium and concrete lighting columns by testing. It gives type tests and so does not cover testing for quality control purposes. It applies to post top lighting columns not exceeding 20 m height for post top lanterns and to lighting columns with brackets not exceeding 18 m height for side entry lanterns. The requirements for lighting columns made from materials other than concrete, steel or aluminium (for example wood, plastic and cast iron) are not specifically covered in this standard.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies design loads for lighting columns. It applies to post top columns not exceeding 20 m height for post top lanterns and to columns with brackets not exceeding 18 m height for side entry lanterns. Special structural designs to permit the attachement of signs, overhead wires, etc. are not covered by this standard. The requirements for lighting columns made from materials other than concrete, steel or aluminium (for example wood, plastic and cast iron) are not specifically covered in this standard.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the verification of the design of steel, aluminium and concrete lighting columns by testing. It gives type tests and so does not cover testing for quality control purposes. It applies to post top lighting columns not exceeding 20 m height for post top lanterns and to lighting columns with brackets not exceeding 18 m height for side entry lanterns. The requirements for lighting columns made from materials other than concrete, steel or aluminium (for example wood, plastic and cast iron) are not specifically covered in this standard.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies design loads for lighting columns. It applies to post top columns not exceeding 20 m height for post top lanterns and to columns with brackets not exceeding 18 m height for side entry lanterns. Special structural designs to permit the attachement of signs, overhead wires, etc. are not covered by this standard. The requirements for lighting columns made from materials other than concrete, steel or aluminium (for example wood, plastic and cast iron) are not specifically covered in this standard.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with fixed external lighting installations. The requirements apply particularly to lighting installations e.g. for roads, parks, gardens, public places, sporting areas, illumination of monuments and flood lighting, and other equipment incorporating lighting such as telephone kiosks, bus shelters, advertising panels, town maps, road signs. Note: External lighting comprises luminaires, wiring system and accessories located outside buildings. [
]This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page numbers correspond to the French-language pages.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day