EN 14303:2009
(Main)Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification
Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification
This European Standard specifies the requirements for factory made mineral wool products, which are used for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately 0 °C to + 800 °C.
NOTE Below an operating temperature of ambient, special means against water vapour diffusion and water accumulation by air flow might be required. Below an operating temperature of - 50 C, special tests regarding the suitability of the products in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases.
The products are manufactured with or without facings or coatings, in the form of rolls, boards, slabs, mats, felts, quilts, wired mats, lamella mats, bevelled lags and pipe sections.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This European Standard does not specify the required level of a given property that shall be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.
Products with a declared thermal conductivity greater than 0,065 W/(m•K) at 10 °C are not covered by this standard.
This Eurpean Standard does not cover products for in situ insulation (blowing or pouring) or products for the insulation of the building structure.
This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.
Wärmedämmstoffe für die technische Gebäudeausrüstung und für betriebstechnische Anlagen in der Industrie - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation
Diese Europäische Norm legt die Anforderungen für werkmäßig hergestellte Produkte aus Mineralwolle fest, die als Wärmedämmstoffe für die technische Gebäudeausrüstung und für betriebstechnische Anlagen in der Industrie im Temperaturbereich von etwa 0 °C bis 800 °C benutzt werden.
ANMERKUNG Unterhalb einer Betriebstemperatur, die der Umgebungstemperatur entspricht, könnten besondere Maßnahmen gegen die Wasserdampfdiffusion und gegen Wasseransammlungen im Dämmstoff auf Grund von Luft¬bewegungen erforderlich sein. Unterhalb einer Betriebstemperatur von 50 °C sind besondere Prüfungen bezüglich der Eignung der Produkte für den beabsichtigten Anwendungsfall ratsam (z. B. Sauerstoffverflüssigung). In jedem Fall sollten die Empfehlungen des Herstellers beachtet werden.
Die Produkte werden mit oder ohne Kaschierung und Beschichtung in der Form von Rollen, Platten, Matten, Filzen, Matratzen, Drahtnetzmatten, Lamellen-Matten, abgeschrägten Segmenten und Rohrschalen her-gestellt.
Diese Europäische Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Fest-legungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehr-schicht-Verbundplatten angewendet; die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Diese Europäische Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte Anwendungen benötigte Stufen können Regelwerken oder Ausschreibungen entnommen werden.
Diese Europäische Norm gilt nicht für Produkte, deren Nennwert der Wärmeleitfähigkeit größer ist als 0,065 W/(mK) bei 10 °C.
Diese Europäische Norm gilt nicht für Produkte für an der Verwendungsstelle hergestellte Wärmedämmung (eingeblasen oder geschüttet) oder Produkte, die zur Dämmung des Bauwerks bestimmt sind.
Produits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Produits manufacturés à base de laines minérales (MW) - Spécification
La présente norme spécifie les exigences relatives aux produits manufacturés à base de laines minérales,
utilisés pour l’isolation thermique de l’équipement du bâtiment et des installations industrielles, dont la
température de service est approximativement comprise entre 0 °C et + 800 °C.
NOTE En cas de température de service inférieure à la température ambiante, des moyens spéciaux contre la
diffusion de la vapeur d’eau et l’accumulation d’eau par écoulement d’air peuvent être requis. Pour une température de
service inférieure à – 50 °C, des essais particuliers sont recommandés pour s'assurer de l'aptitude à l'emploi du produit
dans l'application visée (p.ex. liquéfaction de l'oxygène). Il convient de se référer systématiquement aux conseils du
fabricant.
Les produits sont manufacturés avec ou sans parements ou enduits de finition, sous la forme de rouleaux, de
panneaux, de feutres, de « felts », de matelas capitonnés, de nappes grillagées, de feutres lamellaires, de
segments à onglets et de coquilles.
La présente Norme européenne décrit les caractéristiques de ces produits et comporte des modes
opératoires d’essai, d’évaluation de conformité, de marquage et d’étiquetage.
Les produits couverts par la présente norme sont également utilisés dans les systèmes d’isolation thermique
préfabriqués et les panneaux composites ; les performances des systèmes incorporant ces produits ne sont
pas traitées.
La présente Norme européenne ne spécifie pas le niveau requis pour une propriété donnée que doit posséder
un produit pour démontrer son aptitude à une application particulière. Les niveaux requis pour une application
donnée peuvent être trouvés dans les réglementations et les appels d’offre.
Les produits dont la conductivité thermique déclarée est supérieure à 0,065 W/(m·K) à 10 °C ne sont pas
couverts par la présente norme.
Toplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije - Proizvodi iz mineralne volne (MW) - Specifikacija
Ta evropski standard določa zahteve za proizvode iz mineralne volne, ki se uporabljajo za toplotno izolacijo za opremo stavb in industrijske inštalacije z delovnim temperaturnim razponom med približno 0°C in + 800°C. Proizvodi so narejeni z obrobami ali prevlekami ali brez njih v obliki zvitkov, plošč, blokov, mata, filca, prešitih odej, armiranega mata, lamelarnega mata, prirezanih ploščic in cevnih izolacij. Ta evropski standard opisuje značilnosti proizvodov in vključuje postopke preskušanja, vrednotenja skladnosti, označevanja in uporabe nalepk. Proizvodi, ki jih zajema ta standard, se uporabljajo pri montažnih termoizolacijskih sistemih in vezanih ploščah; zmogljivost sistemov, ki vključujejo te proizvode, ni zajeta. Ta evropski standard ne določa zahtevane ravni določene lastnosti, ki jo mora doseči proizvod, da ustreza zahtevam za uporabnosti pri določenem načinu uporabe. Zahtevane ravni za določen način uporabe so navedene v pravilih in javnih razpisih. Ta standard ne zajema proizvodov z nazivno toplotno prevodnostjo nad 0,065 W/(mK) pri 10°C. Ta evropski standard ne zajema proizvodov za in situ izolacijo (z vpihovanjem ali nalivanjem) ali proizvodov za izolacijo gradbene konstrukcije. Ta evropski standard ne zajema naslednjih zvočnih vidikov: neposredne izolacije zvoka, ki se prenaša po zraku, in indeksa prenosa hrupa udarcev.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije - Proizvodi iz mineralne volne (MW) - SpecifikacijaWärmedämmstoffe für die technische Gebäudeausrüstung und für betriebstechnische Anlagen in der Industrie - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - SpezifikationProduits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Produits manufacturés a base de laines minérales (MW) - SpécificationThermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 14303:2009SIST EN 14303:2010en,fr,de01-april-2010SIST EN 14303:2010SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14303
November 2009 ICS 91.100.60 English Version
Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification
Produits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Produits manufacturés à base de laines minérales (MW) - Spécification
Wärmedämmstoffe für die technische Gebäudeausrüstung und für betriebstechnische Anlagen in der Industrie - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) -Spezifikation This European Standard was approved by CEN on 29 September 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14303:2009: ESIST EN 14303:2010
Contents Page Foreword .31Scope .52Normative references .53Terms, definitions, symbols, units and abbreviated terms .64Requirements .95Test methods . 156Designation code . 187Evaluation of conformity . 198Marking and labelling . 19Annex A (normative)
Factory production control . 21Annex B (informative)
Additional Properties . 25B.1General . 25Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 27Bibliography . 35Figures Figure ZA.1 — Example of CE marking information . 34Tables Table 1 — Levels and classes for thickness tolerances. 11Table 2 — Levels and classes for dimensional tolerances . 11Table 3 — Load for thickness measurements . 12Table
4 — Water vapour diffusion equivalent air layer thickness . 14Table 5 — Test methods, specimens and conditions . 17Table A.1 — Minimum product testing frequencies . 21Table A.2 — Minimum product testing frequencies for the reaction to fire characteristics . 23Table B.1 — Test methods, specimens and conditions . 26Table ZA.1 — Relevant clauses . 28Table ZA.2 — System(s) of attestation of conformity . 29Table ZA.3 — Assignment of evaluation of conformity tasks for products under system 1 . 30Table ZA.4 — Assignment of evaluation of conformity tasks for products under system 3 or system 3 combined with system 4 for reaction to fire . 31 SIST EN 14303:2010
EN 14307,Thermal insulation products for building equipment and industrial installations — Factory made extruded polystyrene foam (XPS) products — Specification EN 14308, Thermal insulation products for building equipment and industrial installations — Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products — Specification EN 14309, Thermal insulation products for building equipment and industrial installations — Factory made products of expanded polystyrene (EPS) — Specification EN 14313, Thermal insulation products for building equipment and industrial installations — Factory made polyethylene foam (PEF) products — Specification EN 14314, Thermal insulation products for building equipment and industrial installations — Factory made phenolic foam (PF) products — Specification According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 14303:2010
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that shall be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard. This Eurpean Standard does not cover products for in situ insulation (blowing or pouring) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.
2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance SIST EN 14303:2010
EN 12939, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172, Thermal insulating products — Evaluation of conformity EN 13467, Thermal insulating products for building equipment and industrial installations — Determination of dimensions, squareness and linearity of preformed pipe insulation EN 13468, Thermal insulating products for building equipment and industrial install
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.