EN 14981:2006
(Main)Surface active agents - Determination of content of high boiling solvents in liquid detergents by GLC
Surface active agents - Determination of content of high boiling solvents in liquid detergents by GLC
This European Standard specifies a method for the identifying and quantifying of high boiling point solvents in finished liquid detergents and raw materials.
Grenzflächenaktive Stoffe - Bestimmung des Gehaltes an hochsiedenden Lösemitteln in flüssigen Reinigungsmitteln durch GLC
Diese Europäische Norm legt ein Verfahren zur qualitativen und quantitativen Analyse von hochsiedenden
Lösemitteln in flüssigen Reinigungsmitteln und Rohstoffen fest.
Agents de surface - Détermination de la teneur en solvants à point d'ébullition élevé dans les détergents liquides par chromatographie en phase gazeuse
La présente Norme européenne décrit une méthode permettant l’identification et la détermination quantitative des solvants à point d’ébullition élevé dans les détergents liquides formulés et les matières premières.
Površinsko aktivne snovi - Določevanje topil z visokim vreliščem v tekočih detergentih s plinsko tekočinsko kromatografijo (GLC)
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Surface active agents - Determination of content of high boiling solvents in liquid detergents by GLCAgents de surface - Détermination de la teneur en solvants a point d'ébullition élevé dans les détergents liquides par chromatographie en phase gazeuseGrenzflächenaktive Stoffe - Bestimmung des Gehaltes an hochsiedenden Lösemitteln in flüssigen Reinigungsmitteln durch GLCTa slovenski standard je istoveten z:EN 14981:2006SIST EN 14981:2007en71.100.40Površinsko aktivna sredstvaSurface active agentsICS:SLOVENSKI
STANDARDSIST EN 14981:200701-april-2007
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14981October 2006ICS 71.100.40 English VersionSurface active agents - Determination of content of high boilingsolvents in liquid detergents by GLCAgents de surface - Détermination de la teneur en solvantsà point d'ébullition élevé dans les détergents liquides parchromatographie en phase gazeuseGrenzflächenaktive Stoffe - Bestimmung des Gehaltes anhochsiedenden Lösemitteln in flüssigen Reinigungsmittelndurch GLCThis European Standard was approved by CEN on 28 August 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14981:2006: E
Examples of chromatogram.9 A.1 Solvent identification.9 A.2 Solvent quantification.12 Annex B (informative)
Statistical and other data derived from the results of inter-laboratory tests.13 Bibliography.14
NOTE A 30 m x 0,25 mm internal diameter, fused silica capillary column (film thickness 0,25 µm) with 100 % polyethylene glycol stationary phase is advisable. 7 Sampling and preparation of the sample The laboratory sample shall be prepared and stored in accordance with ISO 607. 8 Procedure 8.1 Gas chromatographic conditions The following GC conditions have been found to be suitable. At least the quality of separation shown in Figures A.1 and A.2 shall be achieved. Oven temperature programs:
qualitative analysis: 60°C (5 min) to 240°C (5 min) at 5°C/min; qu
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.