EN 14471:2013/FprA1
(Amendment)Chimneys - System chimneys with plastic flue liners - Requirements and test methods
Chimneys - System chimneys with plastic flue liners - Requirements and test methods
This European Standard specifies the performance requirements and test methods for system chimneys with plastic flue liners used to convey the products of combustion from appliances to the outside atmosphere under dry and wet conditions. It also specifies the requirements for marking, manufacturer's instructions and evaluation of conformity. This European Standard describes chimney components from which system chimneys can be assembled. This European Standard is not applicable to chimneys with sootfire resistance classification class G. This European Standard is not applicable for chimneys with the following classification: - corrosion resistance class 2 concerning natural wood ); - corrosion resistance class 3; - pressure class N2. This European Standard is applicable to chimneys designed so that no condensate accumulation can occur, e.g. with a minimum inclination of 3° to the horizontal. This European Standard is not applicable - for system chimneys with plastic coated flue liners; - to structurally independent (free-standing or self-supporting) chimneys. Chimneys with components which need further processing during the installation to reach the final material properties are no system chimneys and therefore also not covered by this standard. This European Standard does not cover the requirements for horizontal terminals (as defined for C1 installation types in CEN/TR 1749) regarding aerodynamic behaviour, rainwater ingress and icing behaviour.
Abgasanlagen - Systemabgasanlagen mit Kunststoffinnenrohen - Anforderungen und Prüfungen
Conduits de fumée - Système de conduits de fumée avec conduits intérieurs en plastique - Prescriptions et méthodes d'essai
Dimniki - Sistemski dimniki s plastičnimi dimniškimi tuljavami - Zahteve in preskusne metode
General Information
- Status
- Not Published
- Technical Committee
- CEN/TC 166 - Chimneys
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 03-Oct-2014
- Due Date
- 10-Jun-2015
- Completion Date
- 03-Oct-2014
Relations
- Effective Date
- 22-Oct-2014
- Amends
EN 14471:2013 - Chimneys - System chimneys with plastic flue liners - Requirements and test methods - Effective Date
- 04-Dec-2013
Overview
EN 14471:2013/FprA1 is a European standard developed by the European Committee for Standardization (CEN) that specifies the performance requirements and test methods for system chimneys with plastic flue liners. These chimneys are designed to safely convey combustion products from various appliances to the outside atmosphere under both dry and wet conditions. The standard also covers marking requirements, manufacturer’s instructions, and conformity evaluation to ensure quality and safety compliance.
This standard applies specifically to system chimneys assembled from standardized chimney components featuring plastic flue liners. However, it excludes chimneys with sootfire resistance classification class G, certain corrosion resistance and pressure classification levels, as well as chimneys with condensate accumulation or plastic coated liners. It is not applicable to free-standing or self-supporting chimneys that are structurally independent.
Key Topics
The standard focuses on several core technical and performance areas to ensure reliable chimney function:
Material and Component Requirements
Specifies the materials and components suitable for use in plastic flue liner chimneys, with emphasis on resistance to chemical corrosion, UV exposure, thermal loads, and condensation.Mechanical and Thermal Load Testing
Defines test methods to evaluate resistance to mechanical stresses, wind loads, and long-term thermal exposure to replicate real-life operating conditions.Gas Tightness and Rainwater Penetration
Establishes procedures to test gas tightness to prevent leaks and methods to resist rainwater ingress, ensuring chimney integrity and safety for external installation.Fire Resistance and Sootfire Safety
Sets thermal resistance classifications necessary to withstand typical chimney operating temperatures, including sootfire resistance within defined classes.Marking and Documentation
Requires clear CE marking, manufacturer identification, and comprehensive Declaration of Performance (DoP), facilitating traceability and compliance with EU regulations.Exclusions and Scope Limitations
Clarifies that chimneys with certain pressure classes (e.g., N2), corrosion resistance levels, or free-standing designs fall outside this standard’s scope.
Applications
EN 14471:2013/FprA1 is directly applicable to:
Residential and Commercial Heating Installations
Including wood, gas, and oil-burning appliances where plastic flue liners are used within system chimneys to safely convey exhaust gases.Prefab Chimney Assemblies
System chimneys assembled from standardized plastic-lined components used in building construction, renovation, or retrofit projects.Manufacturers and Installers
Provides manufacturers with harmonized requirements for designing and testing chimney components and offers guidance for installers regarding proper system assembly.Regulatory Compliance
Enables compliance with EU Construction Products Regulation (CPR) and harmonized standards required for placing chimney systems on the European market.
Related Standards
For a fully compliant system and holistic safety approach, EN 14471:2013/FprA1 works in conjunction with:
EN 13384-1: Chimneys - Design and calculation of chimneys - Part 1: Chimney shafts
Supports dimensioning and flow resistance evaluation for chimney sections and fittings.CEN/TR 1749: Technical Report on chimney terminal types and their aerodynamic, rainwater, and icing behaviors - though horizontal terminals are excluded from EN 14471’s scope.
Construction Products Regulation (Regulation (EU) No 305/2011)
Mandates harmonized assessment and declaration of performance (AVCP) systems and CE marking for construction products like chimneys.
By applying EN 14471:2013/FprA1, manufacturers and building professionals can ensure safe, durable, and efficient installation of plastic flue liner chimneys that meet strict European safety and performance standards. This boosts confidence in product quality and facilitates smoother market acceptance across the EU.
Frequently Asked Questions
EN 14471:2013/FprA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Chimneys - System chimneys with plastic flue liners - Requirements and test methods". This standard covers: This European Standard specifies the performance requirements and test methods for system chimneys with plastic flue liners used to convey the products of combustion from appliances to the outside atmosphere under dry and wet conditions. It also specifies the requirements for marking, manufacturer's instructions and evaluation of conformity. This European Standard describes chimney components from which system chimneys can be assembled. This European Standard is not applicable to chimneys with sootfire resistance classification class G. This European Standard is not applicable for chimneys with the following classification: - corrosion resistance class 2 concerning natural wood ); - corrosion resistance class 3; - pressure class N2. This European Standard is applicable to chimneys designed so that no condensate accumulation can occur, e.g. with a minimum inclination of 3° to the horizontal. This European Standard is not applicable - for system chimneys with plastic coated flue liners; - to structurally independent (free-standing or self-supporting) chimneys. Chimneys with components which need further processing during the installation to reach the final material properties are no system chimneys and therefore also not covered by this standard. This European Standard does not cover the requirements for horizontal terminals (as defined for C1 installation types in CEN/TR 1749) regarding aerodynamic behaviour, rainwater ingress and icing behaviour.
This European Standard specifies the performance requirements and test methods for system chimneys with plastic flue liners used to convey the products of combustion from appliances to the outside atmosphere under dry and wet conditions. It also specifies the requirements for marking, manufacturer's instructions and evaluation of conformity. This European Standard describes chimney components from which system chimneys can be assembled. This European Standard is not applicable to chimneys with sootfire resistance classification class G. This European Standard is not applicable for chimneys with the following classification: - corrosion resistance class 2 concerning natural wood ); - corrosion resistance class 3; - pressure class N2. This European Standard is applicable to chimneys designed so that no condensate accumulation can occur, e.g. with a minimum inclination of 3° to the horizontal. This European Standard is not applicable - for system chimneys with plastic coated flue liners; - to structurally independent (free-standing or self-supporting) chimneys. Chimneys with components which need further processing during the installation to reach the final material properties are no system chimneys and therefore also not covered by this standard. This European Standard does not cover the requirements for horizontal terminals (as defined for C1 installation types in CEN/TR 1749) regarding aerodynamic behaviour, rainwater ingress and icing behaviour.
EN 14471:2013/FprA1 is classified under the following ICS (International Classification for Standards) categories: 91.060.40 - Chimneys, shafts, ducts. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 14471:2013/FprA1 has the following relationships with other standards: It is inter standard links to EN 14471:2013+A1:2015, EN 14471:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 14471:2013/FprA1 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/105. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 14471:2013/FprA1 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2014
'LPQLNL6LVWHPVNLGLPQLNLVSODVWLþQLPLGLPQLãNLPLWXOMDYDPL=DKWHYHLQ
SUHVNXVQHPHWRGH
Chimneys - System chimneys with plastic flue liners - Requirements and test methods
Abgasanlagen - Systemabgasanlagen mit Kunststoffinnenrohen - Anforderungen und
Prüfungen
Conduits de fumée - Système de conduits de fumée avec conduits intérieurs en
plastique - Prescriptions et méthodes d'essai
Ta slovenski standard je istoveten z: EN 14471:2013/FprA1
ICS:
91.060.40 Dimniki, jaški, kanali Chimneys, shafts, ducts
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
FINAL DRAFT
EN 14471:2013
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
July 2014
ICS 91.060.40
English Version
Chimneys - System chimneys with plastic flue liners -
Requirements and test methods
Conduits de fumée - Système de conduits de fumée avec Abgasanlagen - Systemabgasanlagen mit
conduits intérieurs en plastique - Prescriptions et méthodes Kunststoffinnenrohen - Anforderungen und Prüfungen
d'essai
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 166.
This draft amendment A1, if approved, will modify the European Standard EN 14471:2013. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14471:2013/FprA1:2014 E
worldwide for CEN national Members.
Contents Page
Foreword .3
1 Modifications to 4.3, Pressure Classes .4
2 Modifications to 4.4, Sootfire resistance classes .4
3 Modification to 7.2.1, Test sample .5
4 Modification to 7.3, Components subject to wind load .6
5 Modification to 7.5.1, Gas tightness .7
6 Modification to 7.6.4, Rainwater penetration resistance for insulated chimneys for
external installation .8
7 Modifications to 7.7.3, Long-term resistance to thermal load .8
8 Modifications to 11.2, Chimney plate.8
9 Modification to Table ZA.2 – Systems of AVCP .9
10 Modifications to ZA.2.2.3, Example of DoP . 10
11 Modification to ZA.3, CE marking and labelling . 12
Foreword
This document (EN 14471:2013/FprA1:2014) has been prepared by Technical Committee CEN/TC 166
“Chimneys”, the secretariat of which is held by ASI.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
NOTE Due to fact that the Framework Partnership Agreement between the Commission and CEN & CENELEC is not
signed yet, there are currently no New Approach Consultants in place for 2014. Therefore the provisions of CEN-
CENELEC Guide 15 cannot be met.
This shall not prevent the processing of draft standards nor the offering of harmonized standards to the Commission. In
particular, draft standards can be sent to vote without Consultant assessment.
This note will be removed from the Foreword of the finalized publication.
1 Modifications to 4.3, Pressure Classes
st
In the 1 indent, delete "remark: N2 is excluded in the scope of this standard;" and add the following note
st
below the 1 indent:
"NOTE N2 is excluded in the scope of this standard.".
2 Modifications to 4.4, Sootfire resistance classes
st
In the 1 indent, delete "remark: G is excluded in the scope of this standard;" and the following note after the
st
1 indent:
"NOTE G is excluded in the scope of this standard.".
3 Modification to 7.2.1, Test sample
At the end of the subclause, add Figure 1 (same as Figure 1 in 11.2):
"
Key
1 test chimney 6 variable length
2 terminal 7 inspection
3 flue gas inlet 8 measuring opening
4 air gap 9 condensate drain
5 enclosure or outer wall
Figure 1 — Test chimney to determine the resistance to the combination of mechanical and thermal
load
".
4 Modification to 7.3, Components subject to wind load
At the end of the subclause, add the following new Figure 2 and key:
“
Key
A manufacturer's declared freestanding length
C manufacturer's declared maximum wall bracket separation distance
D distance over which the load is distributed = A + C + C/2
1 anchor point
2 wall bracket
Figure 2 — Test assembly for wind load testing
".
5 Modification to 7.5.1, Gas tightness
At the end of the subclause, add Figure 3 (same as Figure 3 in 11.2):
"
Key
1 test chimney 6 manometer
2 equipment for closing the outlet (plate or bladder) 7 inspection fitting
3 seal/adapter 8 condensate drain
4 flowmeter 9 equipment for closing the condensate drain
5 fan (air supply)
Figure 3 — Test chimney to determine the gas tightness
".
6 Modification to 7.6.4, Rainwater penetration resistance for insulated chimneys for
external installation
At the end of the subclause, add Figure 4 (same as Figure 4 in 11.2):
"
Key
1 spray tube 3 free draining plinth
2 sample 4 seal to prevent ingress of water into open
end of section
Figure 4 — Spray apparatus to determine rainwater penetration resistance
".
7 Modifications to 7.7.3, Long-term resistance to thermal load
In Table 10, add the superscript lower case letter "a" after the term "T " in the first column of Table 10 and the
m
superscript lower case letter "b" after the term "t " in the first row of Table 10.
exp
Replace the text of the footnotes in the table with the following text:
“a T shall be at least equal to T .
m nom
b t shall not be shorter than 10 weeks.".
exp
8 Modifications to 11.2, Chimney plate
Delete Figure 1, Figure 2, Figure 3 and Figure 4 (moved to 7.2.1, 7.3, 7.5.1 and 7.6.4 respectively).
9 Modification to Table ZA.2 – Systems of AVCP
Replace Table ZA.2 with the following Table ZA.2:
“
Table ZA.2 — Systems of AVCP
Levels or classes of
Products Intended uses AVCP systems
performance
Prefabricated chimneys Chimneys Any 2+
(storey height elements),
flue liners (elements or
blocks), multi-shell
chimney (elements or
blocks), single walled
chimneys blocks, kits of
free standing chimneys
and attached chimneys
Chimneys terminals Chimneys Any 4
Prefabricated chimneys (A1, A2, B, C) (*) 1
(storey height elements),
flue liners (elements or
blocks), multi-shell For uses subject to (A1, A2, B, C) (**), D, 3
chimney (elements or
regulations on reaction to E
blocks), single walled
fire
chimneys blocks, kits of
free standing chimneys
(A1 to E) (***), F
and attached chimneys
System 1: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.2
System 2+: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.3 including certification of the factory production
control by a notified production control certification body on the basis of initial inspection of the manufacturing plant
and of factory production control as well as of continuous surveillance, assessment and evalua
...