EN ISO 10322-2:1997
(Main)Ophthalmic optics - Semi-finished spectacle lens blanks - Part 2: Specifications for progressive power lens blank (ISO 10322-2:1996)
Ophthalmic optics - Semi-finished spectacle lens blanks - Part 2: Specifications for progressive power lens blank (ISO 10322-2:1996)
Augenoptik - Einseitig fertige Brillenglasblanks - Teil 2: Anforderungen an Gleitsicht-Brillenglasblanks (ISO 10322-2:1996)
Dieser Teil von ISO 10322 legt Anforderungen an die optischen und geometrischen Eigenschaften von einseitig fertigen Gleitsicht-Brillenglasbanks fest. Die Anforderungen an einseitig fertige Ein- und Mehrstärken-Brillenglasblanks sind in ISO 10322-1 festgelegt.
Optique ophtalmique - Verres de lunettes semi-finis - Partie 2: Spécifications pour les verres progressifs (ISO 10322-2:1996)
IEC 60512-99-002:2019. est utilisée pour soumettre à essai des connecteurs relevant du domaine d’application du SC 48B, qui sont utilisés dans les câblages de communication à paires torsadées permettant une alimentation à distance, tels que les câblages symétriques de la classe D (ou d'une classe correspondant à une fréquence supérieure) de l’ISO/IEC 11801, à l’appui de la norme IEEE 802.3bt™ (alimentation électrique par câble Ethernet améliorée/PoE Plus, Power over Ethernet Plus).
L’objet du présent document est de détailler un programme d’essai permettant de déterminer l’aptitude des paires de connecteurs à supporter une séquence d'essais de 100 accouplements et désaccouplements au total. Le courant électrique traverse les connecteurs au cours du désaccouplement uniquement, conformément à l’IEC 60512-9-3.
Mots clés: connecteurs, enclenchement et séparation des connecteurs
Očesna optika - Napol zgotovljena stekla očal - 2. del: Specifikacije za progresivna stekla očal (ISO 10322-2:1996)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 10322-2:2000
01-januar-2000
2þHVQDRSWLND1DSRO]JRWRYOMHQDVWHNODRþDOGHO6SHFLILNDFLMH]DSURJUHVLYQD
VWHNODRþDO,62
Ophthalmic optics - Semi-finished spectacle lens blanks - Part 2: Specifications for
progressive power lens blank (ISO 10322-2:1996)
Augenoptik - Einseitig fertige Brillenglasblanks - Teil 2: Anforderungen an Gleitsicht-
Brillenglasblanks (ISO 10322-2:1996)
Optique ophtalmique - Verres de lunettes semi-finis - Partie 2: Spécifications pour les
verres progressifs (ISO 10322-2:1996)
Ta slovenski standard je istoveten z: EN ISO 10322-2:1997
ICS:
11.040.70 Oftalmološka oprema Ophthalmic equipment
SIST EN ISO 10322-2:2000 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 10322-2:2000
---------------------- Page: 2 ----------------------
SIST EN ISO 10322-2:2000
---------------------- Page: 3 ----------------------
SIST EN ISO 10322-2:2000
---------------------- Page: 4 ----------------------
SIST EN ISO 10322-2:2000
---------------------- Page: 5 ----------------------
SIST EN ISO 10322-2:2000
---------------------- Page: 6 ----------------------
SIST EN ISO 10322-2:2000
INTERNATIONAL
Is0
STANDARD
10322-2
Second edition
1996-02-01
Ophthalmic optics - Semi-finished
spectacle lens blanks -
Part 2:
Specifications for progressive power lens
blanks
Op tique oph talmique - Verres de lunettes semi-finis -
Partie 2: Spkifica tions pour les verres progressifs
Reference number
IS0 10322-2:1996(E)
---------------------- Page: 7 ----------------------
SIST EN ISO 10322-2:2000
IS0 10322-2:1996(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide
federation of national standards bodies (IS0 member bodies). The work
of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. IS0
collaborates closely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard IS0 10322-2 was prepared by Technical Committee
lSO/TC 172, Optics and optical instruments, Subcommittee SC 8,
Ophthalmic optics.
This second edition cancels and replaces the first edition
(IS0 10322-2:1991), which has been technically revised.
IS0 10322 consists of the following parts, under the general title
Ophthalmic optics - Semi-finished spectacle lens blanks:
- Part 7: Specifications for single-vision and multifocal lens blanks
- Part 2: Specifications for progressive power lens blanks
Annexes A, B and C of this part of IS0 10322 are for information only.
0 IS0 1996
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from the publisher.
lnternationa I Organization for Standardiza tion
Case Postal e 56 l CH-121 1 Geneve 20 l Switzerland
Printed in Switzerland
II
---------------------- Page: 8 ----------------------
SIST EN ISO 10322-2:2000
IS0 10322=2:1996(E)
INTERNATIONAL STANDARD 0 IS0
- Semi-finished spectacle lens
Ophthalmic optics
blanks -
Part 2:
Specifications for progressive power lens blanks
3 Definitions
1 scope
For the purposes of this part of IS0 10322, the defi-
This part of IS0 10322 specifies requirements for the
nitions given in IS0 13666 apply.
optical and geometrical properties of semi-finished
progressive power spectacle lens blanks. The re-
quirements for semi-finished single-vision and multi-
4 Classification
focal lens blanks are given in IS0 10322-I.
Semi-finished lens blanks are classified as follows:
a) single-vision semi-finished lens blanks;
b) multifocal semi-finished lens blanks;
2 Normative references
c) progressive power semi-finished lens blanks.
The following standards contain provisions which,
through reference in this text, constitute provisions
5 Requirements
of this part of IS0 10322. At the time of publication,
the editions indicated were valid. All standards are
The tolerances shall apply at a temperature of
subject to revision, and parties to agreements based
23 “C + 5 “C.
-
on this part of IS0 10322 are encouraged to investi-
gate the possibility of applying the most recent edi-
tions of the standards indicated below. Members of
5.1 Optical requirements on the finished
IEC and IS0 maintain registers of currently valid
surface
International Standards.
IS0 7944:1984, Optics and optical instruments - 5.1 .I General
Reference wavelengths.
The optical tolerances shall apply at the reference
IS0 10322-I :I 996, Ophthalmic optics - Semi-fin-
points of the semi-finished lens blank at one of the
ished spectacle lens blanks - Part 1: Specifications
reference wavelengths specified in IS0 7944.
for single-vision and multifocal lens blanks.
The as-worn position can result in the apparent power
to the eye being different from that determined as a
I SO 13666:-J, Ophthalmic optics - Spec tacies
focimeter determination.
lenses - Vocabulary.
1) To be published.
---------------------- Page: 9 ----------------------
SIST EN ISO 10322-2:2000
0 IS0
IS0 10322=2:1996(E)
If the manufacturer has applied corrections to com- b) effective size (d,): actual dimension(s) in milli-
pensate for the as-worn position (see annex B), then metres of the lens blank;
the tolerances shall apply to the corrected value and
c) usable size (d,): dimension(s) in millimetres of the
this corrected value shall be stated by the manufac-
area that is optically usable.
turer on the package or in an accompanying document
(see 8.1).
The tolerances on size shall be as follows:
5.1.2 Tolerances on the surface power of
a) effective size:
semi-finished progressive power lens blanks
dead,-1 mm
The tolerances on the surface power as specified in
table 1 shall apply at the distance design reference
d,
point and shall be measured using the method de-
scribed in 6.1.
b) usable size:
d, 3 d, - 1 mm for d, < 65 mm
5.1.3 Tolerances on the addition power
d” 3 & - 2 mm for d, > 65 mm
The tolerances on the addition power as specified in
table2 shall apply at the design reference points and
The tolerance on usable size does not apply to blanks
shall be measured using the method described in
with a carrier curve, such as lenticulars.
62 . .
5.2.2 Tolerances on thickness
5.2 Geometrical tolerances
5.2.2.1 Centre thickness
5.2.1 Tolerances on the size of lens blanks
The centre thickness of the lens blank, when meas-
ured at its geometric centre (unless otherwise stated
The sizes of lens blanks are classified as follows:
by the manufacturer), shall be not less than the mini-
a) nominal size (&): dimension(s), in millimetres in- mum thickness stated by the manufacturer with a
dicated by the manufacturer; tolerance of +!j mm.
Table 1 - Tolerances on the surface power
Values in dioptres (D)
Tolerance on astigmatism
Tolerance on distance
Distance surface power of
specified by the
surface power
the meridian with the
manufacturerl)
highest absolute distance
Fl + F2
surface power
IF, 421
2
I
3 0,OO and 6 IO,00 + o,c9 0,09
I------- I -
1
> IO,00 and < 15,00 & 0,12
0,12
I
I
NOTE - F, and F2 are the surface powers of the principal meridians.
I
I
1) Relative to the intended surface astigmatism of the lens design.
I I
---------------------- Page: 10 ----------------------
SIST EN ISO 10322-2:2000
IS0 10322-2: 1996(E)
0 IS0
IS0 10322-I :I 995, 6.3, are not excluded from this
part of IS0 10322 for a transition period of 5 years
- Tolerances on the addition power
Table 2
after publication of the first edition of IS0 10322-I
Values in dioptres (D)
(I 991-l 2-l 5).
Alternative measurement methods are acceptable if
shown to perform equivalently to the above reference
method.
6.3 Nlaterial and surface quality
5.2.2.2 Edge thickness
See annex A.
When measured at the point stated by the manufac-
turer, the edge thickness of the lens blank shall be not
less than the minimum thickness stated by the
manufacturer with a tolerance of +i mm.
7 Marking
7.1 Permanent marking
6 Test methods
The lens blank shall be permanently marked on the
...
Questions, Comments and Discussion