Polymeric materials, cellular flexible - Method of assessment of air flow value at constant pressure-drop (ISO 7231:1984)

Weichelastische Schaumstoffe - Verfahren zur Bestimmung der Luftdurchlässigkeit bei konstantem Staudruck (ISO 7231:1984)

Die vorliegende internationale Norm schreibt ein Verfahren zur Bestimmung der Luftdurchlässigkeit von weichelastischen Schaumstoffen vor. Luftdurchlässigkeitswerte können dazu verwendet werden, einen Hinweis von Effekten von Rezepturen und Herstellungsveränderungen auf die Zellenstruktur zu liefern.

Matériaux polymères alvéolaires souples - Détermination de l'indice d'écoulement d'air - Méthode à chute de pression constante (ISO 7231:1984)

Polimerni materiali – Penjeni polimeri - Mehke pene - Metoda ocenjevanja vrednosti zračnega pretoka pri konstantni razliki tlakov (ISO 7231:1984)

General Information

Status
Withdrawn
Publication Date
18-Nov-1997
Withdrawal Date
30-Jun-2010
Technical Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Jul-2010
Completion Date
01-Jul-2010

Relations

Buy Standard

Standard
EN ISO 7231:1999
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 7231:1999
01-maj-1999
3ROLPHUQLPDWHULDOL±3HQMHQLSROLPHUL0HKNHSHQH0HWRGDRFHQMHYDQMD
YUHGQRVWL]UDþQHJDSUHWRNDSULNRQVWDQWQLUD]OLNLWODNRY ,62
Polymeric materials, cellular flexible - Method of assessment of air flow value at constant
pressure-drop (ISO 7231:1984)
Weichelastische Schaumstoffe - Verfahren zur Bestimmung der Luftdurchlässigkeit bei
konstantem Staudruck (ISO 7231:1984)
Matériaux polymeres alvéolaires souples - Détermination de l'indice d'écoulement d'air -
Méthode a chute de pression constante (ISO 7231:1984)
Ta slovenski standard je istoveten z: EN ISO 7231:1997
ICS:
83.100 Penjeni polimeri Cellular materials
SIST EN ISO 7231:1999 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 7231:1999

---------------------- Page: 2 ----------------------

SIST EN ISO 7231:1999

---------------------- Page: 3 ----------------------

SIST EN ISO 7231:1999

---------------------- Page: 4 ----------------------

SIST EN ISO 7231:1999
7231
International Standard
INTERNATIONAL ORGANIZATION FOR STANDARDIZATlON~MElK~YHAPO~HAfl OPTAHM3AUMR IlO CTAHflAPTM3A~MM@ORGANlSATlON INTERNATIONALE DE NORMALISATION
Polymeric materials, cellular flexible - Method of
assessment of air flow value at constant pressure-drop
Matkriaux polymkres alvbolaires soup/es - Determination de l’indice d’koulement d’air - Mbthode 2 chute de pression
constante
First edition - 1984-12-15
Ref. No. IS0 7231-1984 (E)
s UDC 678-4Q5.8 : 532.5
cellular materials, flexible cellular materials, tests, determination, air flow, testing conditions, test specimens.
Descriptors:
Price based on 4 pages

---------------------- Page: 5 ----------------------

SIST EN ISO 7231:1999
Foreword
IS0 (the International Organization for Standardization) is a worldwide federation of
national standards bodies (IS0 member bodies). The work of preparing International
Standards is normally carried out through IS0 technical committees. Each member
body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated to
the member bodies for approval before their acceptance as International Standards by
the IS0 Council. They are approved in accordance with IS0 procedures requiring at
least 75 % approval by the member bodies voting.
International Standard IS0 7231 was prepared by Technical Committee ISO/TC 45,
Rubber and rubber products.
International Organization for Standardization, 1984
0
Printed in Switzerland

---------------------- Page: 6 ----------------------

SIST EN ISO 7231:1999
IS0 7231-1984 (E)
INTERNATIONAL STANDARD
Polymeric materials, cellular flexible - Method of
assessment of air flow value at constant pressure-drop
1 Scope and field of application Traps to prevent manometer liquid being drawn into the
chamber by accidental excess pressure changes shall be pro-
This International Standard specifies a method for determining
vided. A plunger in the fluid reservoir is used to set the zero
the air flow value of cellular polymeric flexible materials. Air point after levelling the manometer.
flow values may be used to give an indication of the effects of
formulation and production variables on the cellular structure.
NOTE - The use of an inclined manometer with 2 Pa graduation is
recommended. A level mounted on the manometer should be used to
ensure that the proper degree of inclination from the horizontal is
maintained.
2 Definition
4.3 Blowers
air flow value: The volume flow rate required to maintain a
constant pressure differential across a flexible foam test piece.
The air supply may be such that positive or negative pressure
differences from atmospheric pressure are obtained across the
For the purposes of this International Standard the units of air
test piece, using compressed air, exhaust blower or vacuum
flow value are cubic decimetres per second.
pumps etc.
NOTE - A particular apparatus may be constructed to use only
positive or negative pressure.
3 Principle
4.4 Test piece mounting
A specified constant air pressure differential is created across a
standard flexible foam specimen. The rate of flow of air
A chamber of nominal dimensions 140 mm diameter x 150 mm
required to maintain this pressure differential is the air flow
depth (see figure 1) or 75 mm diameter x 1000 mm length (see
value.
figure 2) incorporating a test piece mounting and fittings for
the manometer and exhaust shall be provided. The test piece
cavity shall be 50 If: 0,05 mm x 50 + 0,05 mm x 25 + 0,05 mm.
4 Apparatus
The test piece shall be supported by suitable means, for
example by the use of vanes, wires or a perforated support.