Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test

Elektromagnetische Verträglichkeit (EMV) - Teil 4-17: Prüf- und Meßverfahren - Prüfung der Störfestigkeit gegen Wechselanteile der Spannung an Gleichstrom-Netzanschlüssen

Compatibilité électromagnétique (CEM) - Partie 4-17: Techniques d'essai et de mesure - Essai d'immunité à l'ondulation résiduelle sur entrée de puissance à courant continu

Elektromagnetna združljivost (EMC) - 4-17. del: Preskusne in merilne tehnike - Preskus odpornosti proti valovitosti na vhodu za napajanje z enosmerno napetostjo (IEC 61000-4-17:1999/A2:2008)

General Information

Status
Published
Publication Date
17-Feb-2009
Withdrawal Date
31-Jan-2012
Current Stage
6060 - Document made available - Publishing
Start Date
18-Feb-2009
Completion Date
18-Feb-2009

Relations

Overview

EN 61000-4-17:1999/A2:2009 (adoption of IEC 61000-4-17 with Amendment 2) is a European/IEC test standard in the EMC family that specifies testing and measurement techniques for assessing immunity to ripple on d.c. input power ports. It defines how to generate, inject and measure residual low-frequency ripple and low-frequency components on direct‑current power inputs so that equipment behavior under realistic power conditions can be evaluated for electromagnetic compatibility.

This amendment (A2, 2009) updates the original 1999 edition and was endorsed by CENELEC as EN 61000-4-17:1999/A2:2009. Annex ZA and certain normative-reference clarifications were introduced as part of the amendment.

Key topics and requirements

  • Scope of testing: Procedures for performing a ripple-on-d.c. input power port immunity test to determine whether equipment continues to operate within acceptable limits when subjected to residual ripple or low-frequency ac components on its DC supply.
  • Test and measurement techniques: Methods for generating ripple waveforms, injecting ripple onto DC power ports, and measuring the waveform and equipment response using appropriate instrumentation.
  • Verification of generator characteristics: Requirements to verify the test generator’s performance and characteristics (see section 6.2 - amendment modifies text regarding references).
  • Normative references: The standard relies on general EMC vocabulary and environmental testing standards, notably IEC 60050‑161 (EMC vocabulary) and IEC 60068‑1 (environmental testing). Amendment A2 removed some dated references and the IEC 61000‑4‑11 reference from the normative list.
  • Conformance and documentation: Test setup, measurement points and reporting conventions necessary for reproducible and auditable immunity assessment.

Note: This summary avoids specification of numerical test levels or waveform parameters - consult the full standard for exact test amplitudes, frequency content and pass/fail criteria.

Applications and who uses it

  • Product compliance testing: EMC laboratories use this standard to validate that products with DC power inputs (industrial controllers, telecom equipment, battery‑operated devices, power supplies, etc.) tolerate ripple without malfunction.
  • Design verification: Design and test engineers apply the methods during development to identify susceptibility to power-line ripple and to qualify mitigation (filtering, regulation).
  • Regulatory and procurement: Compliance teams and procurement specialists reference this standard when specifying EMC immunity requirements for equipment to ensure reliability in environments with imperfect DC supplies.
  • Manufacturers and integrators: Ensure consistent performance and reduce field failures related to DC supply disturbances.

Related standards

  • IEC/EN 61000 series (EMC basic standards and other immunity tests)
  • IEC 60050‑161 (International Electrotechnical Vocabulary - EMC terms)
  • IEC 60068‑1 (Environmental testing - general guidance)
  • Note: Amendment A2 clarifies normative references and removes IEC 61000‑4‑11 as a normative reference in this document.

Keywords: EMC, EN 61000-4-17, IEC 61000-4-17, ripple on DC input, ripple immunity test, DC power port, testing and measurement techniques, immunity testing.

Amendment
EN 61000-4-17:2001/A2:2009
English language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2009
Elektromagnetna združljivost (EMC) - 4-17. del: Preskusne in merilne tehnike -
Preskus odpornosti proti valovitosti na vhodu za napajanje z enosmerno
napetostjo (IEC 61000-4-17:1999/A2:2008)
Electromagnetic compatibility (EMC) -- Part 4-17: Testing and measurement techniques -
Ripple on d.c. input power port immunity test
Elektromagnetische Verträglichkeit (EMV) -- Teil 4-17: Prüf- und Meßverfahren - Prüfung
der Störfestigkeit gegen Wechselanteile der Spannung an Gleichstrom-Netzanschlüssen
Compatibilité électromagnétique (CEM) -- Partie 4-17: Techniques d'essai et de mesure -
Essai d'immunité à l'ondulation résiduelle sur entrée de puissance à courant continu
Ta slovenski standard je istoveten z: EN 61000-4-17:1999/A2:2009
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61000-4-17/A2
NORME EUROPÉENNE
February 2009
EUROPÄISCHE NORM
ICS 33.100.20
English version
Electromagnetic compatibility (EMC) -
Part 4-17: Testing and measurement techniques -
Ripple on d.c. input power port immunity test
(IEC 61000-4-17:1999/A2:2008)
Compatibilité électromagnétique (CEM) - Elektromagnetische Verträglichkeit
Partie 4-17: Techniques d'essai (EMV) -
et de mesure - Teil 4-17: Prüf- und Meßverfahren -
Essai d'immunité à l'ondulation résiduelle Prüfung der Störfestigkeit
sur entrée de puissance à courant continu gegen Wechselanteile der Spannung
(CEI 61000-4-17:1999/A2:2008) an Gleichstrom-Netzanschlüssen
(IEC 61000-4-17:1999/A2:2008)
This amendment A2 modifies the European Standard EN 61000-4-17:1999; it was approved by CENELEC on
2009-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-4-17:1999/A2:2009 E

Foreword
The text of document 77A/632/CDV, future amendment 2 to IEC 61000-4-17:1999, prepared by SC 77A,
Low frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 61000-4-17:1999
on 2009-02-01.
The following dates were fixed:
– latest da
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 61000-4-17:1999/A2:2009 is a amendment published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test". This standard covers: Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test

Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test

EN 61000-4-17:1999/A2:2009 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61000-4-17:1999/A2:2009 has the following relationships with other standards: It is inter standard links to EN 61000-4-17:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61000-4-17:1999/A2:2009 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 61000-4-17:1999/A2:2009 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

The article is about a standard called EN 61000-4-17:1999/A2:2009, which is focused on electromagnetic compatibility (EMC). Specifically, it addresses the testing and measurement techniques for assessing the immunity of devices to ripple on the direct current (d.c.) input power port. The standard provides guidelines and procedures for conducting these tests to ensure that devices are not affected by unwanted ripple on their power ports.

기사 제목: EN 61000-4-17:1999/A2:2009 - 전자기적 호환성(EMC) - 파트 4-17: 시험 및 측정 기법 - 직류 입력 전력 포트 내 리플 간섭 시험 기사 내용: 이 기사는 EN 61000-4-17:1999/A2:2009라는 표준에 대한 내용입니다. 이 표준은 전자기적 호환성(EMC)에 초점을 맞추고 있습니다. 구체적으로, 디바이스의 직류(d.c.) 입력 전력 포트에 대한 리플 간섭에 대한 견디는 능력을 평가하기 위한 시험 및 측정 기법을 다루고 있습니다. 이 표준은 이러한 시험을 수행하는 가이드라인과 절차를 제공하여 디바이스가 원치않는 리플에 영향을 받지 않도록 보장합니다.

기사 제목: EN 61000-4-17:1999/A2:2009 - 전자파적합성 (EMC) - 파트 4-17: 테스트 및 측정 기법 - 직류 입력 전력 포트에 대한 립플 면역 시험 기사 내용: 이 기사는 전자파적합성 (EMC)에 관련된 EN 61000-4-17:1999/A2:2009 표준에 대해 다룬다. 이 표준은 테스트 및 측정 기법에 관련하여 직류 (d.c.) 입력 전력 포트에 대한 립플 면역을 측정하기 위한 지침을 제공한다. 이 표준은 전자 기기가 전력 입력의 립플에 의해 유발되는 교란에 면역성을 가지도록 보장하기 위한 테스트를 진행하는 데 중요하다. 이 기사는 다양한 환경에서 전자 기기의 올바른 기능을 보장하는 데 이 표준의 중요성을 강조하고 있다.

The article discusses the EN 61000-4-17:1999/A2:2009 standard, which is related to electromagnetic compatibility (EMC), specifically in testing and measuring the immunity of ripple on the direct current (d.c.) input power port. This standard provides guidelines for conducting tests to ensure that electronic devices are immune to disturbances caused by ripple on their power input. The article highlights the importance of this standard in ensuring the proper functioning of electronic devices in various environments.

記事タイトル:EN 61000-4-17:1999/A2:2009 - 電磁両立性(EMC) - パート4-17:テストおよび計測技術 - 直流入力電力ポートへのリップルの免疫試験 記事内容:この記事では、EN 61000-4-17:1999/A2:2009規格について述べています。この規格は、電磁両立性(EMC)に関連し、直流(d.c.)入力電力ポート上のリップルの免疫性をテストおよび計測するためのガイドラインを提供しています。この規格は、電子機器が電力入力のリップルによる干渉から免疫を持つことを確認するためのテストの重要性を強調しています。この規格は、さまざまな環境で電子機器の正しい動作を確保するために重要です。

記事タイトル:EN 61000-4-17:1999/A2:2009 - 電磁両立性(EMC)- Part 4-17: 試験と測定技術- 直流入力電力ポートのリップルに対する耐性試験 記事内容:この記事は、EN 61000-4-17:1999/A2:2009という規格についてです。これは、電磁両立性(EMC)に焦点を当てたものです。具体的には、デバイスが直流(d.c.)入力電力ポートのリップルに対してどれだけ耐性を持っているかを評価するための試験と測定技術について説明しています。この規格は、デバイスが電力ポート上の望ましくないリップルに影響を受けないようにするために、これらのテストを実施するためのガイドラインと手順を提供しています。