IEC/SC 77A - IEC_SC_77A
Standardization in the field of electromagnetic compatibility with regard to low frequency phenomena (ca <= 9 kHz, see note). Note: This limit frequency can be adapted to a higher frequency according to the phenomena or equipment
IEC_SC_77A
Standardization in the field of electromagnetic compatibility with regard to low frequency phenomena (ca <= 9 kHz, see note). Note: This limit frequency can be adapted to a higher frequency according to the phenomena or equipment
General Information
IEC 61000-2-4:2024 is available as IEC 61000-2-4:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-2-4:2024 is related to conducted disturbances in the frequency range from 0 kHz to 150 kHz. It gives compatibility levels in differential mode (L-L and L-N) for industrial locations, with a nominal voltage up to 35 kV and a nominal frequency of 50 Hz or 60 Hz. NOTE 1 Industrial locations are defined in 3.1.8. Power distribution systems on ships, aircraft, offshore platforms and railways are not included. NOTE 2 See also Annex E. The compatibility levels specified in this document apply at the in-plant point of coupling (IPC). The level of the low-frequency disturbances at the terminals of equipment receiving its supply from the IPC is generally assumed to be similar to the disturbance level at the IPC itself. However, in some situations this is not the case, particularly when a long feeder is dedicated to the supply of a particular load, or when a disturbance is generated or amplified within the installation of which the equipment forms a part. Compatibility levels are specified for the types of low-frequency electromagnetic disturbances expected at any in-plant point of coupling (IPC) within industrial locations, for guidance in the definition of: a) limits for disturbance emissions in industrial power distribution systems (including the planning levels defined in 3.1.5); NOTE 3 A very wide range of conditions is possible in the electromagnetic environments of industrial networks. These are approximated in this document by the three classes described in Clause 4. However, it is the responsibility of the operator of such a network to take account of the particular electromagnetic and economic conditions, including equipment characteristics, in setting the above-mentioned limits. b) immunity levels for the equipment within these systems. The disturbance phenomena considered are: - voltage deviations; - voltage dips and short interruptions; - voltage imbalance; - power-frequency variations; - harmonics up to order 40; - interharmonics up to the 40th harmonic; - voltage components above the 40th harmonic up to 150 kHz; - DC component; - transient overvoltages. The compatibility levels are given for different classes of environment determined by the characteristics of the supply network and loads. NOTE 4 Compatibility levels at the point of common coupling (PCC) on public networks are specified in IEC 61000‑2‑2 for low-voltage networks and IEC 61000‑2‑12 for medium-voltage networks. IEC TR 61000‑3‑6 and IEC TR 61000‑3‑7 describe the approach of power distribution system operators to the limitation of emissions from installations and large loads. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) introduction of new classes 2a, 2b and 2L (former class 2); b) modification of existing compatibility levels for class 3; c) addition of compatibility levels in the frequency range 2 kHz to 150 kHz; d) addition of compatibility levels using a new quantity: partial weighted harmonic distortion (PWHD).
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft16 pagesEnglish languagesale 10% offe-Library read for1 day
NEW!IEC 61000-3-11:2017 is available as IEC 61000-3-11:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-3-11:2017 is concerned with the emission of voltage changes, voltage fluctuations and flicker produced by equipment and impressed on the public low-voltage supply system. It specifies the limits of voltage changes produced by equipment tested under specified conditions. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a new Annex A which explains the limitations and effectiveness of IEC 61000‑3-11 regarding the connection of multiple items of similar equipment at the same location in the supply network.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation24 pagesSlovenian languagesale 10% offe-Library read for1 day
2020-12-14 EC letter: citation of EN + A1 put on hold EMC and RED - either to cite with a restriction or TC to povide other solution, link to directives temporary removed
2020-02-19: EC mail with concerns for citation under RED and subsequently also EMC - CCMC proposal to discuss during EC EG RE 2020-03-02
2020-02-07: EC letter acception for citation EMCD
2019-06-06 D163/C005: noting positive assessment, approved Annex ZZ and ZA and asked to make document available
2019-04-24: BT doc prepared
2019-03-32 D162/C065 TC to submit EMC elements to BT
2019-02-01: confirmation of positive assessment for RED and EMCD
2019-01-23 lacking answer, EY Confirmation requested
2019-01-07 EY Confirmation requested
2018-11-30 Discussed with under EY Quality Review: simplifierd AR is inconclusive
2018-09-03: HAS assessment (2018-08-02) : interpreted to be 'Compliant', go to BT for integration in the text of Annexes ZZ
2018-05-22: submitted for assessment on 2018-05-18
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
2019-03-19: TC Secretary has requested to proceed with publication. No Annex ZZ needed.
Link to M/452 (safety of music players) removed, standard supporting to EMC, but not as hEN.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the corrigendum of January 2022 have been included in this copy.
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the Interpretation sheet of August 2021 have been included in this copy. Apply to the English version only.
- Amendment21 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. It gives compatibility levels for public low voltage a.c. distribution systems having a nominal voltage up to 420 V, single-phase or 690 V, three-phase and a nominal frequency of 50 Hz or 60 Hz.
- Amendment17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-4-11:2020 is available as IEC 61000-4-11:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-4-11:2020 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This document applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz AC networks. It does not apply to electrical and electronic equipment for connection to 400 Hz AC networks. Tests for these networks will be covered by future IEC documents. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. NOTE 1 Voltage fluctuation immunity tests are covered by IEC 61000-4-14. The test method documented in this document describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. NOTE 2 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and, if applied, they are responsible for defining the appropriate test levels. Technical committee 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. This third edition cancels and replaces the second edition published in 2004 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - rise time and fall time of transients are now defined terms in Clause 3; - the origin of voltage dips and short interruptions is now stated in Clause 4. Keywords: immunity test methods, low-voltage power supply networks
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
NEW!IEC 61000-3-2:2018 is available as IEC 61000-3-2:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low‑voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and can be subject to installation restrictions as indicated in IEC 61000-3-12. The tests according to this document are type tests. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) an update of the emission limits for lighting equipment with a rated power ≤ 25 W to take into account new types of lighting equipment; b) the addition of a threshold of 5 W under which no emission limits apply to all lighting equipment; c) the modification of the requirements applying to the dimmers when operating non‑incandescent lamps; d) the addition of test conditions for digital load side transmission control devices; e) the removal of the use of reference lamps and reference ballasts for the tests of lighting equipment; f) the simplification and clarification of the terminology used for lighting equipment; g) the classification of professional luminaires for stage lighting and studios under Class A; h) a clarification about the classification of emergency lighting equipment; i) a clarification for lighting equipment including one control module with an active input power ≤ 2 W; j) an update of the test conditions for television receivers; k) an update of the test conditions for induction hobs, taking also into account the other types of cooking appliances; l) for consistency with IEC 61000-3-12, a change of the scope of IEC 61000-3-2 from equipment with an input current ≤ 16 A to equipment with a rated input current ≤ 16 A. Keywords: harmonic currents
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation39 pagesSlovenian languagesale 10% offe-Library read for1 day
This part of IEC 61000 defines the immunity test methods and range of recommended basic
test levels for electrical and electronic equipment with rated current up to 16 A per phase at
disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz
mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz
a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional
immunity of electrical and electronic equipment when subjected to harmonics and interharmonics
and mains signalling frequencies. The test method documented in this part of IEC
61000 describes a consistent method to assess the immunity of an equipment or system
against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication
for use by product committees of the IEC. As also stated in Guide 107, the IEC product
committees are responsible for determining whether this immunity test standard should be
applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with
product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.)
is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are
not considered in this standard.
The levels proposed are more adapted for residential, commercial and light industry
environments. For heavy industrial environments the product committees are responsible for
the definition of a class X with the necessary levels. They have also the possibility of defining
more complex waveforms for their own need. Nevertheless, the simple waveforms proposed
have been mainly observed on several networks (flat curve more often for single phase
system) and also on industrial networks (overswing curve more for three phase systems).
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-4-16:2015 is available as IEC 61000-4-16:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-16:2015 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply, control, signal and communication ports. It has the status of a basic EMC publication in accordance with IEC Guide 107. This second edition cancels and replaces the first edition published in 1998, Amendment 1:2001 and Amendment 2:2009. This edition constitutes a technical revision.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
NEW! IEC 61000-4-30:2015 is available as IEC Standards+ 61000-4-30:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-30:201 5 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method's implementation. This standard addresses measurement methods for in-situ measurements. Measurement of parameters covered by this standard is limited to conducted phenomena in power systems. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, mains signalling on the supply voltage, rapid voltage changes, and current measurements. Emissions in the 2 kHz to 150 kHz range are considered in Annex C (informative), and over- and underdeviations are considered in Annex D (informative). Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the measurement method for current, previously informative, is now normative with some changes; - the measurement method for RVC (rapid voltage change) has been added; - the measurement method for conducted emissions in the 2 kHz to 150 kHz range has been added in informative Annex C; - underdeviation and overdeviation parameters are moved to informative Annex D; - Class A and Class S measurement methods are defined and clarified, while Class B is moved to informative Annex E and considered for future removal; - measurement methods continue in this standard, but responsibility for influence quantities, performance, and test procedures are transferred to IEC 62586-2.
- Standard73 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation71 pagesSlovenian languagesale 10% offe-Library read for1 day
IEC 61000-4-19:2014 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports. The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines: - test waveforms; - range of test levels; - test equipment; - test setup; - test procedures; - and verification procedures. These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems. The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000-4-13. Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000-4-16. Key words: electromagnetic compatibility, EMC
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
NEW! IEC 61000-3-3:2013 is available as IEC Standards+ 61000-3-3:2013 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-3-3:2013 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. It is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection. IEC 61000-3-3 has the status of a product family standard within the IEC 61000 series. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision which takes account of the changes made in IEC 61000-4-15:2010.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation37 pagesSlovenian languagesale 10% offe-Library read for1 day
IEC 61000-3-12:2011 deals with the limitation of harmonic currents injected into the public supply system. The limits given in this International Standard are applicable to electrical and electronic equipment with a rated input current exceeding 16 A and up to and including 75 A per phase, intended to be connected to public low-voltage a.c. distribution systems of the following types: - nominal voltage up to 240 V, single-phase, two or three wires; - nominal voltage up to 690 V, three-phase, three or four wires; - nominal frequency 50 Hz or 60 Hz. Other distribution systems are excluded. The limits given in this edition apply to equipment when connected to 230/400 V, 50 Hz systems. This standard applies to equipment intended to be connected to low-voltage systems interfacing with the public supply at the low-voltage level. It does not apply to equipment intended to be connected only to private low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. This standard defines: a) requirements and emission limits for equipment; b) methods for type tests and simulations. Tests according to this International Standard are type tests of complete pieces of equipment. Conformity with this standard can also be determined by validated simulations. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The significant technical changes with respect to the previous edition are: - the replacement of the reference fundamental current I1 by the reference current Iref for the calculation of emission limits;
- a new added table of current emission limits (Table 5); - a new added annex (Annex A) to define test conditions for some types of equipment; - Deletion of the former Annexes B (Approximate interpolation formulas) and D (Information on the PWHD factor).
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation29 pagesSlovenian languagesale 10% offe-Library read for1 day
IEC 61000-4-15:2010 gives a functional and design specification for flicker measuring apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be constructed. A method is given for the evaluation of flicker severity on the basis of the output of flickermeters complying with this standard. The flickermeter specifications in this part of IEC 61000 relate only to measurements of 120 V and 230 V, 50 Hz and 60 Hz inputs. Characteristics of some incandescent lamps for other voltages are sufficiently similar to the values in Table 1 and Table 2, that the use of a correction factor can be applied for those other voltages. Some of these correction factors are provided in the Annex B. Detailed specifications for voltages and frequencies other than those given above, remain under consideration. The object of this part of IEC 61000 is to provide basic information for the design and the instrumentation of an analogue or digital flicker measuring apparatus. It does not give tolerance limit values of flicker severity. This second edition cancels and replaces the first edition published in 1997 and its Amendment 1 (2003) and constitutes a technical revision. This new edition, in particular, adds or clarifies the definition of several directly measured parameters, so that diverging interpretations are avoided. It has the status of a basic EMC publication in accordance with IEC Guide 107. NEW! IEC 61000-4-15:2010 is also available as IEC Standards+ 61000-4-15:2010 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-4-8:2009 relates to the immunity requirements of equipment, only under operational conditions, to magnetic disturbances at power frequencies 50 Hz and 60 Hz related to: - residential and commercial locations; - industrial installations and power plants; - medium voltage and high voltage sub-stations. The applicability of IEC 61000-4-8:2009 to equipment installed in different locations is determined by the presence of the phenomenon, as specified in Clause 4. This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. Other IEC standards dealing with conducted disturbances cover these aspects. The object of IEC 61000-4-8:2009 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment for household, commercial and industrial applications when subjected to magnetic fields at power frequency (continuous and short duration field). IEC 61000-4-8:2009 defines: - recommended test levels; - test equipment; - test set-up; - test procedure. This second edition cancels and replaces the first edition published in 1993 and its Amendment 1 (2000). It forms a technical revision. This edition includes the following significant technical changes with respect to the previous edition: the scope is extended in order to cover 60 Hz. Characteristics, performance and verification of the test generator and related inductive coils are revised. Modifications are also introduced in the test set-up (GRP) and test procedure. IEC 61000-4-8:2009 has the status of a basic EMC publication in accordance with IEC Guide 107. NEW! IEC 61000-4-8:2009 is also available as IEC Standards+ 61000-4-8:2009 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the corrigendum of October 2009 have been included in this copy.
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61000 defines the immunity test methods and range of recommended basic
test levels for electrical and electronic equipment with rated current up to 16 A per phase at
disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz
mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz
a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional
immunity of electrical and electronic equipment when subjected to harmonics and interharmonics
and mains signalling frequencies. The test method documented in this part of IEC
61000 describes a consistent method to assess the immunity of an equipment or system
against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication
for use by product committees of the IEC. As also stated in Guide 107, the IEC product
committees are responsible for determining whether this immunity test standard should be
applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with
product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.)
is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are
not considered in this standard.
The levels proposed are more adapted for residential, commercial and light industry
environments. For heavy industrial environments the product committees are responsible for
the definition of a class X with the necessary levels. They have also the possibility of defining
more complex waveforms for their own need. Nevertheless, the simple waveforms proposed
have been mainly observed on several networks (flat curve more often for single phase
system) and also on industrial networks (overswing curve more for three phase systems).
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
Title changed by this A1
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Title changed by this A2
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment26 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This standard applies to electrical and electronic equipment having a rated input current exceeding 16 A per phase. It covers equipment installed in residential areas as well as industrial machinery, specifically voltage dips and short interruptions for equipment connected to either 50 Hz or 60 Hz a.c. networks, including 1-phase and 3-phase mains. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. The test method documented in this part of EN 61000 describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. It has the status of a Basic EMC Publication in accordance with IEC Guide 107.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation33 pagesSlovenian languagesale 10% offe-Library read for1 day
Subclause 8.1 (Climatic conditions) and clause 9 (Evaluation of test results) have been amended. Contains a new clause 10 (Test report).
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Subclause 8.1 (Climatic conditions) and clause 9 (Evaluation of test results) have been amended. Contains a new clause 10 (Test report).
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Subclause 8.1.1 (Climatic conditions) and clause 9 (Evaluation of test results) have been amended. Contains a new clause 10 (Test report).
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 61000 is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected in public medium voltage power supply systems, for guidance in: a) the limits to be set for disturbance emission into public power supply systems (including the planning levels defined in 3.1.5); b) the immunity limits to be set by product committees and others for the equipment exposed to the conducted disturbances present in public power supply systems. The disturbance phenomena considered are: voltage fluctuations and flicker, harmonics up to and including order 50, inter-harmonics up to the 50th harmonic, voltage distortions at higher frequencies (above 50th harmonic), voltage dips and short supply interruptions, voltage unbalance, transient overvoltages, power frequency variation, d.c. components, mains signalling. The medium-voltage systems covered by this standard are public distribution systems supplying either: a) private installations in which equipment is connected directly or through transformers, or b) substations feeding public low-voltage distribution systems.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to instrumentation intended for measuring spectral components in the frequency range up to 9 kHz which are superimposed on the fundamental of the power supply systems at 50 Hz and 60 Hz. For practical considerations, this standard distinguishes between harmonics, interharmonics and other components above the harmonic frequency range, up to 9 kHz. Defines the measurement instrumentation intended for testing individual items of equipment in accordance with emission limits given in certain standards (for example, harmonic current limits as given in EN 61000-3-2) as well as for the measurement of harmonic currents and voltages in actual supply systems.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 61000 is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz. It gives numerical compatibility levels for industrial and non-public power distribution systems at nominal voltages up to 35 kV and a nominal frequency of 50 Hz or 60 Hz. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected at any in-plant point of coupling within industrial plants or other non-public networks, for guidance in a) limits to be set for disturbance emission into industrial power supply systems; b) the choice of immunity levels for the equipment within these systems.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation37 pagesSlovenian languagesale 10% offe-Library read for1 day
Gives compatibility levels to be considered in public low-voltage supply systems with regard to the above-mentioned phenomena. Compatibility levels are intended to serve as reference values for trouble-free operation for equipment installed in public power supply systems.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Defines the immunity test methods and range of recommended basic test levels for electrical and electronic equipment with rated current up to 16 A per phase at disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz mains) for harmonics and interharmonics on low voltage power networks. Establishes a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to harmonics and inter-harmonics and mains signalling frequencies. The test method documented in this part of EN 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
Establishes a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on d.c. power ports. This standard defines: - the range of test levels; - the test generator; - the test set-up; - the test procedure.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
Considers immunity tests for electric and/or electronic equipment (apparatus and system) in its electromagnetic environment. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks. Establishes a reference for evaluating the immunity of electrical and electronic equipment when subjected to unbalanced power supply voltage. Applies to 50 Hz/60 Hz three-phase powered electrical and/or electronic equipment with rated line current up to 16 A per phase.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the general requirements for central power supply systems for an independent energy supply to essential safety equipment. This standard covers systems permanently connected to AC. supply voltages not exceeding 1 000 V and that use batteries as the alternative power source. The central power supplies are intended to energise emergency escape lighting in the case of failure of the normal supply, and maybe suitable for energising other essential safety equipment for example: - electrical circuits of automatic fire extinguishing installations; - paging systems and signalling safety installations; - smoke extraction equipment; - carbon monoxide warning systems; - specific safety installations related to specific buildings e.g. high-risk areas. Schematic representations of typical central power supply equipment are depicted in clause 4. When a UPS system is used to feed these essential safety systems, it must comply with EN 50091-1 and its relevant parts, and the additional requirements of this standard. The power supply system for fire alarms covered by EN 54 are excluded.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
Establishes a reference for evaluating the immunity of electric and electronic equipment when subjected to variations of the power frequency. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
Defines test methods for immunity to ripple at the d.c. input power port of electrical or electronic equipment. Applies to low-voltage d.c. power ports of equipment supplied by external rectifier systems, or batteries which are being charged. This standard defines - test voltage waveform; - range of test levels; - test generator; - test set-up; - test procedure.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to electrical and/or electronic equipment that have a rated input current up to 16 A per phase. Aims to establish a reference for evaluating the immunity of electric and/or electronic equipment when subjected to positive and negative low amplitude voltage fluctuations. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial power supply networks. Has the status of a Basic EMC publication.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-3-2:2014 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having an input current up to and including 16 A per phase, and intended to be connected to public low voltage distribution systems. Arc welding equipment which is not professional equipment, with input current up to and including 16 A per phase, is included in this standard. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this standard and may be subject to installation restrictions as indicated in IEC/TR 61000-3-4 or IEC 61000-3-12. The tests according to this standard are type tests. Test conditions for particular equipment are given in Annex C. For systems with nominal voltages less than 220 V (line-to-neutral), the limits have not yet been considered. This fourth edition cancels and replaces the third edition published in 2005, Amendment 1:2008, Amendment 2:2009 and Corrigendum of August 2009. This edition includes the following significant technical changes with respect to the previous edition: - a clarification of the repeatability and reproducibility of measurements; - a more accurate specification of the general test conditions for information technology equipment; - the addition of optional test conditions for information technology equipment with external power supplies or battery chargers; - the addition of a simplified test method for equipment that undergoes minor changes or updates; - an update of the test conditions for washing machines; - a clarification of the requirements for Class C equipment with active input power ≤ 25 W; - an update of the test conditions for audio amplifiers; - a clarification of the test conditions for lamps; - an update of the test conditions for vacuum cleaners; - the addition of test conditions for high pressure cleaners; - an update of the test conditions for arc welding equipment; - the reclassification of refrigerators and freezers with variable-speed drives into Class D; - and the addition of test conditions for refrigerators and freezers.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
Amandma A2:2011 je dodatek k standardu SIST EN 61000-4-16:1999.
The document contains the immunity requirements and tests for electrical and electronic equipment which are subjected to conducted disturbances in the range DC to 150 kHz. Herefore the range of test levels, the test equipment, the test set-up and the test procedure are specified.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61000-3-2:2014
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61000-3-2:2014
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-4-30:2008 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method's implementation. This standard addresses measurement methods for in situ measurements. Measurement of parameters covered by this standard is limited to voltage phenomena that can be conducted in a power system. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, mains signalling on the supply voltage and rapid voltage changes. Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. IEC 61000-4-30:2008 gives measurement methods and appropriate performance requirements, but does not set thresholds. The effects of transducers inserted between the power system and the instrument are acknowledged but not addressed in detail in this standard. Precautions on installing monitors on live circuits are addressed. IEC 61000-4-30:2008 has the status of a basic EMC publication in accordance with IEC Guide 107. This second edition cancels and replaces the first edition published in 2003. This edition includes the following significant technical changes with respect to the previous edition: - Adjustments, clarifications, and corrections to class A and class B measurement methods. - A new category, class S, intended for survey instruments, has been added. - A new Annex C gives guidance on instruments.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-3-3:2008 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. This part of IEC 61000 is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection. The tests according to this part are type tests. Particular test conditions are given in annex A and the test circuit is shown in Figure 1. This second edition IEC 61000-3-3 cancels and replaces the first edition published in 1994, amendment 1 (2001) and amendment 2 (2005). This edition constitutes a revised edition. NEW! IEC 61000-3-3:2008 is also available as IEC Standards+ 61000-3-3:2008 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61000-3-2:2014
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day