Superconductivity - Part 24: Critical current measurement - Retained critical current after double bending at room temperature of Ag-sheathed Bi-2223 superconducting wires

IEC 61788-24:2018 describes a test method for determining the retained critical current after double bending at room temperature of short and straight Ag- and/or Ag alloy-sheathed Bi-2223 superconducting wires that have the shape of a flat or square tape containing mono- or multicores of oxides. The wires can be laminated with copper alloy, stainless steel or Ni alloy tapes. The test method is intended for use with superconductors that have a critical current less than 300 A and an n-value larger than 5.

Supraleitfähigkeit - Teil 24: Messung des kritischen Stroms - Verbleibender kritischer Strom nach Doppelbiegung bei Raumtemperatur in Ag-ummantelten Bi-2223 supraleitenden Drähten

Supraconductivité - Partie 24: Mesurage du courant critique - Courant critique retenu après double flexion à température ambiante des fils supraconducteurs Bi-2223 avec gaine Ag

IEC 61788-24:2018 décrit une méthode d’essai permettant de déterminer le courant critique retenu après double flexion à température ambiante de fils supraconducteurs rectilignes courts Bi-2223 avec gaine Ag et/ou en alliage d’Ag, ayant la forme d’une bande plate ou carrée et contenant des noyaux simples ou plusieurs noyaux d’oxydes. Les fils peuvent être stratifiés avec des bandes en alliage de cuivre, en acier inoxydable ou en alliage de Ni. La méthode d’essai est destinée à être utilisée avec des supraconducteurs ayant un courant critique inférieur à 300 A et une valeur n supérieure à 5.

Superprevodnost - 24. del: Meritve kritičnega toka - Obdržani kritični tok po dvojnem upogibu posrebrenih Bi-2223 superprevodnih žic pri sobni temperaturi (IEC 61788-24:2018)

Ta del standarda IEC 61788 opisuje preskusno metodo za določanje obdržanega kritičnega toka
po dvojnem upogibu (pri sobni temperaturi) posrebrenih ali s srebrovo zlitino prevlečenih
Bi-2223 superprevodnih žic z obliko ravnega ali kvadratnega traku, ki vsebuje eno- ali
večjedrne okside. Žice so lahko laminirane s trakovi iz bakrene zlitine, nerjavnega jekla ali
nikljeve zlitine.
Preskusna metoda je namenjena za uporabo s superprevodniki, katerih kritični tok je manjši
od 300 A in n-vrednost večja od 5. Preskus za določanje obdržanega kritičnega toka
se izvede brez magnetnega polja, pri čemer je preskusni vzorec potopljen v odprto kopel
s tekočim dušikom.

General Information

Status
Published
Publication Date
23-Aug-2018
Withdrawal Date
22-Jul-2021
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
24-Aug-2018
Completion Date
24-Aug-2018

Buy Standard

Standard
EN IEC 61788-24:2018 - BARVE
English language
32 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN IEC 61788-24:2018
01-november-2018
6XSHUSUHYRGQRVWGHO0HULWYHNULWLþQHJDWRND2EGUåDQLNULWLþQLWRNSR
GYRMQHPXSRJLEXSRVUHEUHQLK%LVXSHUSUHYRGQLKåLFSULVREQLWHPSHUDWXUL
,(&
Superconductivity - Part 24: Critical current measurement - Retained critical current after
double bending at room temperature of Ag-sheathed Bi-2223 superconducting wires
(IEC 61788-24:2018)
Supraleitfähigkeit - Teil 24: Messung des kritischen Stroms - Verbleibender kritischer
Strom nach Doppelbiegung bei Raumtemperatur in Ag-ummantelten Bi-2223
supraleitenden Drähten
Supraconductivité - Partie 24: Mesurage du courant critique - Courant critique retenu
après double flexion à température ambiante des fils supraconducteurs Bi-2223 avec
gaine Ag
Ta slovenski standard je istoveten z: EN IEC 61788-24:2018
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
29.050 Superprevodnost in prevodni Superconductivity and
materiali conducting materials
29.060.10 Žice Wires
SIST EN IEC 61788-24:2018 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN IEC 61788-24:2018

---------------------- Page: 2 ----------------------

SIST EN IEC 61788-24:2018


EUROPEAN STANDARD EN IEC 61788-24

NORME EUROPÉENNE

EUROPÄISCHE NORM
August 2018
ICS 29.050; 77.040.10; 17.220

English Version
Superconductivity - Part 24: Critical current measurement -
Retained critical current after double bending at room
temperature of Ag-sheathed Bi-2223 superconducting wires
(IEC 61788-24:2018)
Supraconductivité - Partie 24: Mesurage du courant critique Supraleitfähigkeit - Teil 24: Messung des kritischen Stroms
- Courant critique retenu après double flexion à température - Verbleibender kritischer Strom nach Doppelbiegung bei
ambiante des fils supraconducteurs Bi-2223 avec gaine Ag Raumtemperatur in Ag-ummantelten Bi-2223
(IEC 61788-24:2018) supraleitenden Drähten
(IEC 61788-24:2018)
This European Standard was approved by CENELEC on 2018-07-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN IEC 61788-24:2018 E

---------------------- Page: 3 ----------------------

SIST EN IEC 61788-24:2018
EN IEC 61788-24:2018 (E)
European foreword
The text of document 90/402/FDIS, future edition 1 of IEC 61788-24, prepared by IEC/TC 90
"Superconductivity" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN IEC 61788-24:2018.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2019-04-23
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2021-07-23
document have to be withdrawn


Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 61788-24:2018 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61788-3 NOTE Harmonized as EN 61788-3


2

---------------------- Page: 4 ----------------------

SIST EN IEC 61788-24:2018
EN IEC 61788-24:2018 (E)
Annex ZA
(normative)

...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.