(Main)Alcohol interlocks - Test methods and performance requirements - Part 2: Instruments having a mouthpiece and measuring breath alcohol for general preventive use
Alcohol interlocks - Test methods and performance requirements - Part 2: Instruments having a mouthpiece and measuring breath alcohol for general preventive use
This European Standard specifies test methods and performance requirements for breath alcohol controlled alcohol interlocks having a mouthpiece. It covers alcohol interlocks intended for general preventive use. This European Standard is directed at test laboratories and manufacturers of alcohol interlocks. It defines requirements and test procedures for type approval. Several parameters (for example alcohol concentration or breath volume) are specified in this European Standard for the purpose of type testing according to this standard only. However, it may be necessary due to national regulations or depending on user requests to set the values of the prescribed parameters differently when the alcohol interlocks are in use. This European Standard also applies to alcohol interlocks integrated into other systems of the vehicle. This European Standard does not apply to – alcohol interlocks intended for use in traffic safety programmes for drink driving offenders (see EN 50436-1), – instruments measuring the alcohol concentration in the ambient air in the vehicle, – alcohol interlocks not having a mouthpiece, – methods of installation and connections to the vehicle.
Alkohol-Interlocks - Prüfverfahren und Anforderungen an das Betriebsverhalten - Teil 2: Geräte mit Mundstück zur Messung des Atemalkohols für den allgemein-präventiven Einsatz
Diese Europäische Norm legt Prüfverfahren und Anforderungen an das Betriebsverhalten für atem-alkohol¬gesteuerte Alkohol-Interlocks fest, die ein Mundstück haben. Sie behandelt Alkohol-Interlocks, die für den allgemein-präventiven Einsatz vorgesehen sind. Diese Europäische Norm richtet sich an Prüflaboratorien und Hersteller von Alkohol-Interlocks. Sie legt Anforderungen und Prüfverfahren für die Typprüfung fest. Einzelne Parameter (wie zum Beispiel Alkoholkonzentration oder Atemvolumen) sind in dieser Europäischen Norm nur für den Zweck der Typprüfung nach dieser Norm festgelegt. Möglicherweise ist es jedoch notwendig, auf Grund von nationalen Vorschriften oder abhängig von Benutzerwünschen die Werte dieser Parameter für den Einsatz der Alkohol-Interlocks abweichend festzulegen. Diese Europäische Norm gilt auch für Alkohol-Interlocks, die in andere Steuersysteme des Fahrzeugs integriert sind, als auch für mit dem Alkohol-Interlock verbundene Zusatzgeräte. Diese Europäische Norm gilt nicht für – Alkohol-Interlocks, die für den Einsatz in Verkehrssicherheitsprogrammen für Trunkenheitsfahrer vorgesehen sind (siehe EN 50436-1), – Geräte, die die Alkoholkonzentration in der Innenraumluft des Fahrzeugs messen, – Alkohol-Interlocks, die kein Mundstück besitzen, – Installationsverfahren und Verbindungen zum Fahrzeug.
Ethylotests anti-démarrage - Méthodes d’essais et exigences de performance - Partie 2: Appareils équipés d’un embout et mesurant le taux d’alcoolémie de l’air expiré, à usage préventif général
Alkoholne zapore - Preskusne metode in zahtevane lastnosti - 2. del: Instrumenti z ustnikom, ki merijo alkohol v sapi, za splošno preventivno uporabo
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2014
1DGRPHãþD
SIST EN 50436-2:2008
Alkoholne zapore - Preskusne metode in zahtevane lastnosti - 2. del: Instrumenti z
ustnikom, ki merijo alkohol v sapi, za splošno preventivno uporabo
Alcohol interlocks - Test methods and performance requirements - Part 2: Instruments
having a mouthpiece and measuring breath alcohol for general preventive use
Alkohol-Interlocks - Prüfverfahren und Anforderungen an das Betriebsverhalten - Teil 2:
Geräte mit Mundstück zur Messung des Atemalkohols für den allgemein-präventiven
Einsatz
Ethylotests anti-démarrage - Méthodes d’essais et exigences de performance - Partie 2:
Appareils équipés d’un embout et mesurant le taux d’alcoolémie de l’air expiré, à usage
préventif général
Ta slovenski standard je istoveten z: EN 50436-2:2014
ICS:
13.200 3UHSUHþHYDQMHQHVUHþLQ Accident and disaster control
NDWDVWURI
43.040.80 Varnostne naprave in sistemi Safety installations and
za zadrževanje restraint systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50436-2
NORME EUROPÉENNE
January 2014
EUROPÄISCHE NORM
ICS 43.040.10; 71.040.40 Supersedes EN 50436-2:2007
English version
Alcohol interlocks -
Test methods and performance requirements -
Part 2: Instruments having a mouthpiece and measuring breath alcohol
for general preventive use
Ethylotests anti-démarrage - Alkohol-Interlocks -
Méthodes d’essais et exigences de Prüfverfahren und Anforderungen an das
performance - Betriebsverhalten -
Partie 2: Appareils équipés d’un embout Teil 2: Geräte mit Mundstück zur Messung
et mesurant le taux d’alcoolémie de l’air des Atemalkohols für den allgemein-
expiré, à usage préventif général präventiven Einsatz
This European Standard was approved by CENELEC on 2013-10-21. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia,
Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands,
Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50436-2:2014 E
Contents
Page
Foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General requirements . 6
4.1 Blocking and not-blocking . 6
4.2 Influence on the vehicle motor . 6
4.3 Tampering . 6
4.4 Concentration limit . 6
4.5 Mouthpiece . 7
4.6 Readiness . 7
4.7 Data memory, download and evaluation . 7
4.8 Retests . 7
4.9 Recall . 8
4.10 Override function . 8
4.11 Combination with other systems . 8
4.12 Communication integrity . 8
4.13 Wireless communication . 8
4.14 Basic functionality . 8
5 General test methods . 8
6 Electrical tests . 8
7 Calibration curve . 8
8 Durability tests. 8
8.1 Temperature cycles . 8
8.2 Condensed water . 9
8.3 Vibrations . 9
8.4 Drop test . 9
9 Environmental tests . 9
9.1 General . 9
9.2 Temperature . 9
9.3 Temperature and supply voltage . 9
9.4 Temperature and humidity . 9
9.5 Warm-up time . 9
9.6 Pressure . 9
9.7 Protection by enclosure . 10
10 Breath sample . 10
11 Analytical specificity . 10
– 3 – EN 50436-2:2014 (E)
Page
12 Manipulation and circumvention . 10
13 Timer . 10
13.1 Start period . 10
13.2 Restart period . 10
13.3 Service reminder . 10
13.4 Calibration interval . 10
13.4.1 Calibration interval stored in the alcohol interlock . 10
13.4.2 Calibration interval not stored in the alcohol interlock . 10
14 Long term behaviour . 10
15 Instructions . 11
15.1 Instructions for installation (applicable to alcohol interlocks for aftermarket installation
only). 11
15.2 Instructions for use . 11
15.3 Instructions for service . 11
16 Test report . 11
17 Labelling and marking . 11
Annex A Description of events . 11
Annex B Performance testing . 11
Bibliography . 11
Foreword
This document (EN 50436-2:2014) has been prepared by CLC/BTTF 116-2 "Alcohol interlocks".
The following dates are fixed:
(dop) 2014-10-21
• latest date by which this document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2016-10-21
• latest date by which the national
standards conflicting with this
document have to be withdrawn
This document supersedes EN 50436-2:2007.
EN 50436-2:2007:
– EN 50436-1 is now the basic standard and EN 50436-2 describes only the differences in the
requirements compared to EN 50436-1.
– Several of the changes in EN 50436-1 have already been part of EN 50436-2:2007.
– Sub-clause 4.7: statements for download and evaluation of the data memory are revised.
– Sub-clause 9.3: the temperature test is revised.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
– 5 – EN 50436-2:2014 (E)
Introduction
The purpose of alcohol interlocks is to enhance traffic safety by preventing persons with alcohol
concentrations exceeding a set limit value from driving a motor vehicle. EN 50436 series specifies test
methods and essential performance requirements for alcohol interlocks and gives guidance for
decision makers, purchasers and users.
The content and requirements of EN 50436-1 are based on the experience and necessities of drink
driving offender programmes in different countries over several decades. Therefore, alcohol interlocks
used in programmes for drink driving offenders should comply with the above European Standard.
Part 1 is the principal document in EN 50436 series.
Alcohol interlocks for general preventive use are the subject of this part of EN 50436. General
preventive use, which concerns a much larger number of drivers and vehicles, applies to both
professional and private drivers of motor vehicles.
The purpose of EN 50436 series is to specify essential performance requirements and to provide the
respective test methods for available technologies. The technology of alcohol interlocks continues to
evolve, and further innovations can be expected. These could be considered in new parts or revisions
of this European Standard.
1 Scope
This European Standard specifies test methods and performance requirements for breath alcohol
controlled alcohol interlocks having a mouthpiece. It covers alcohol interlocks intended for general
preventive use.
This European Standard is directed at test laboratories and manufacturers of alcohol interlocks. It
defines requirements and test procedures for type testing.
Several parameters (for example alcohol concentration or breath volume) are specified in this