EN 50288-3-2:2003
(Main)Multi-element metallic cables used in analogue and digital communication and control - Part 3-2: Sectional specification for unscreened cables characterised up to 100 MHz - Work area and patch cord cables
Multi-element metallic cables used in analogue and digital communication and control - Part 3-2: Sectional specification for unscreened cables characterised up to 100 MHz - Work area and patch cord cables
Mehradrige metallische Daten- und Kontrollkabel für analoge und digitale Übertragung - Teil 3-2: Rahmenspezifikation für ungeschirmte Kabel bis 100 MHz - Geräteanschlusskabel und Schaltkabel
Câbles métalliques à éléments multiples utilisés pour les transmissions et les commandes analogiques et numériques - Partie 3-2: Spécification intermédiaire pour les câbles non blindés pour applications jusqu'à 100 MHz - Câbles de zone de travail et de brassage
Multi-element metallic cables used in analogue and digital communication and control - Part 3-2: Sectional specification for unscreened cables characterised up to 100 MHz - Work area and patch cord cables
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 50288-3-2:2004
STANDARD
april 2004
Multi-element metallic cables used in analogue and digital communication and
control - Part 3-2: Sectional specification for unscreened cables characterised up to
100 MHz - Work area and patch cord cables
ICS 33.120.20 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD EN 50288-3-2
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2003
ICS 33.120.20 Supersedes EN 50288-3-2:2001
English version
Multi-element metallic cables used in analogue
and digital communication and control
Part 3-2: Sectional specification for unscreened cables
characterised up to 100 MHz -
Work area and patch cord cables
Câbles métalliques à éléments multiples Mehradrige metallische Daten-
utilisés pour les transmissions und Kontrollkabel für analoge
et les commandes analogiques und digitale Übertragung
et numériques Teil 3-2: Rahmenspezifikation
Partie 3-2: Spécification intermédiaire für ungeschirmte Kabel bis 100 MHz -
pour les câbles non blindés Geräteanschlusskabel und Schaltkabel
pour applications jusqu'à 100 MHz -
Câbles de zone de travail et de brassage
This European Standard was approved by CENELEC on 2003-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50288-3-2:2003 E
Foreword
This European Standard was prepared by SC 46XC, Multicore, Multipair and Quad Data
communication cables, of Technical Committee CENELEC TC 46X, Communication cables.
The text of the draft was submitted to the Unique Acceptance Procedure and was approved
by CENELEC as EN 50288-3-2 on 2003-10-01.
This European Standard supersedes EN 50288-3-2:2001
The following dates were fixed:
- latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2004-10-01
- latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2006-10-01
This Part 3-2 is to be read in conjunction to EN 50288-1.
_________
– 3 – EN 50288-3-2:2003
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Definitions. 4
4 Cable construction. 4
4.1 Conductor. 4
4.2 Insulation. 5
4.3 Cabling elements . 5
4.4 Identification of cabling elements. 5
4.5 Screening of cabling elements. 5
4.6 Cable make-up . 5
4.7 Filling compound. 5
4.8 Interstitial fillers . 5
4.9 Screening of the cable core. 5
4.10 Moisture barriers. 5
4.11 Wrapping layers. 5
4.12 Sheath. 5
5 Tests and requirements for completed cables. 6
5.1 Electrical tests . 6
5.2 Mechanical tests . 8
5.3 Environmental tests . 9
5.4 Fire performance tests . 9
1 Scope
This sectional specification covers unscreened cables, characterised up to 100 MHz, to be
used as work area cables to connect a telecommunications outlet to the terminal equipment
and for patch cord cables to establish connections on a patch panel as defined in EN 50173.
Work area cables may also be used as patch cord cables in any distributor of a generic
building wiring system to interconnect with equipment or to cross-connect between cabling
systems.
The electrical, mechanical, transmission and environmental performance characteristics of
the unscreened cables, related to their reference test methods, are detailed.
This sectional specification is to be read in conjunction with EN 50288-1 which contains the
essential provisions for its application.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and
the cited publications are listed hereafter. For dated references, subsequent amendments to
or revisions of these publications apply to this European Standard only when incorporated in
it by amendment or revision. For undated references, the latest edition of the cited
publication applies, together with any amendments.
EN 50173 Information technology - Generic cabling systems
EN 50288-1 Multi-element metallic cables used in analogue and digital
communication and control - Part 1: Generic specification
EN 50289 Series Communication cables - Specifications for test methods
EN 50290 Ser
...