Fluorescent induction lamps - Safety specifications

IEC 62532:2011 specifies the safety requirements for fluorescent induction lamps for general lighting purposes. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure, which can be used to make limited assessment of batches, are also given in this standard.

Leuchtstoff-Induktionslampen - Sicherheitsanforderungen

Lampes à fluorescence à induction - Spécifications de sécurité

La CEI 62532:2011 spécifie les exigences de sécurité pour les lampes à fluorescence à induction pour l'éclairage général. Elle spécifie aussi la méthode qu'il convient que le fabricant utilise pour démontrer la conformité de ses produits aux exigences de la présente norme, méthode basée sur l'évaluation de la qualité de la production globale, associée aux résultats d'essais enregistrés sur les produits finis. Cette méthode peut aussi être appliquée à des fins de certification. Des précisions sont également données dans la présente norme sur la procédure de contrôle par lots, qui peut être utilisée pour l'appréciation limitée de la qualité des lots.

Fluorescenčne indukcijske sijalke - Varnostne specifikacije

Ta mednarodni standard opredeljuje varnostne zahteve za fluorescenčne indukcijske sijalke za splošno razsvetljavo. Prav tako določa metodo, ki jo mora uporabiti proizvajalec, da izkaže skladnost z zahtevami tega standarda na podlagi presoje celotne proizvodnje, v povezavi s svojimi zapisi o preskusih končnih izdelkov. Ta metoda se lahko uporablja tudi za certifikacije. Podrobnosti o šaržnem preskusnem postopku, ki se lahko uporablja za omejeno oceno serij, so prav tako podane v tem standardu. Shematske risbe sistemov so prikazane v dodatku A.

General Information

Status
Published
Publication Date
12-May-2011
Withdrawal Date
06-Mar-2014
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
13-May-2011
Completion Date
13-May-2011

Relations

Buy Standard

Standard
EN 62532:2011
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2011
)OXRUHVFHQþQHLQGXNFLMVNHVLMDONH9DUQRVWQHVSHFLILNDFLMH
Fluorescent induction lamps - Safety specifications
Lampes à fluorescence à induction - Spécifications de sécurité
Ta slovenski standard je istoveten z: EN 62532:2011
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 62532
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.140.30
English version
Fluorescent induction lamps -
Safety specifications
(IEC 62532:2011)
Lampes à fluorescence à induction -  Leuchtstoff-Induktionslampen -
Spécifications de sécurité Sicherheitsanforderungen
(CEI 62532:2011) (IEC 62532:2011)

This European Standard was approved by CENELEC on 2011-03-07. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62532:2011 E
Foreword
The text of document 34A/1422/FDIS, future edition 1 of IEC 62532, prepared by SC 34A, Lamps, of
IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as EN 62532 on 2011-03-07.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2011-12-07
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2014-03-07
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62532:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60112:2003 NOTE  Harmonized as EN 60112:2003 (not modified).
IEC 60529:1989 NOTE  Harmonized as EN 60529:1991 (not modified).
IEC 60664-1:2007 NOTE  Harmonized as EN 60664-1:2007 (not modified).
IEC 61199:1999 NOTE  Harmonized as EN 61199:1999 (not modified).
IEC 62471:2006 NOTE  Harmonized as EN 62471:2008 (not modified).
__________
- 3 - EN 62532:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 60061 - Lamp caps and holders together - -
with gauges for the control of
interchangeability and safety
IEC 60360 1998 Standard method of measurement of lamp EN 60360 1998
cap temperature rise
IEC 60598-1 (mod) 2008 Luminaires - EN 60598-1 2008
Part 1: General requirements and tests + A11 2009

IEC 60695-2-10 - Fire hazard testing - EN 60695-2-10 -
Part 2-10: Glowing/hot-wire based test
methods - Glow-wire apparatus and common
test procedure
IEC 60695-2-11 - Fire hazard testing - EN 60695-2-11 -
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for end-products
IEC 60901 - Single-capped fluorescent lamps - EN 60901 -
Performance specifications
IEC 61347-1 (mod) - Lamp controlgear - EN 61347-1 -
Part 1: General and safety requirements

IEC 62532 ®
Edition 1.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Fluorescent induction lamps – Safety specifications

Lampes à fluorescence à induction – Spécifications de sécurité

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX T
ICS 29.140.30 ISBN 978-2-88912-352-0

– 2 – 62532  IEC:2011
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Safety requirements . 8
4.1 General . 8
4.2 Marking . 8
4.2.1 Marking of the lamps . 8
4.2.2 Requirements . 9
4.3 Requirements for mechanical and electrical connections . 9
4.3.1 Construction and assembly of the lamp . 9
4.3.2 Requirements for electrical connections . 9
4.3.3 Caps and holders . 9
4.4 Insulation resistance . 9
4.4.1 Test method to determine insulation resistance after humidity
treatment . 9
4.4.2 Requirement for the insulation resistance . 10
4.5 Electric strength . 10
4.5.1 Test method to determine the electric strength . 10
4.5.2 Requirement for the electric strength . 10
4.5.3 Compliance . 10
4.6 Parts which can become accidentally live . 10
4.6.1 Metal parts intended to be insulated . 10
4.6.2 Live parts that project from the lamp . 10
4.6.3 Methods to show compliance . 11
4.7 Resistance to heat and fire . 11
4.8 Creepage distances and clearances for lamps . 11
4.9 Temperature rise of the measuring points . 11
4.10 Endurance . 11
4.11 UV radiation . 11
4.12 Information for luminaire design . 11
4.13 Information for ballast design . 11
5 Assessment . 11
Annex A (informative) Schematic drawings of induction lamps . 12
Annex B (informative) Information for luminaire design . 15
Annex C (normative) Schematic drawings for insulation resistance test . 16
Annex D (informative) Information for ballast design . 17
Annex E (normative) Information for thermal test . 19
Annex F (normative) Values and method of measurement of the maximum
temperature rise of the measurement points . 21
Bibliography . 25

62532  IEC:2011 – 3 –
Figure A.1 – Schematic drawing of an internal coupled induction lamp (operating
frequency 2 500 kHz to 3 000 kHz) . 12
Figure A.2 – Schematic drawing of an internal coupled induction lamp (operating
frequency 120 kHz to 145 kHz) . 13
Figure A.3 – Schematic drawing of an external coupled induction lamp (operating
frequency 225 kHz to 275 kHz) . 14
Figure C.1 – Test set up for measurement insulation resistance of internal coupled
induction lamp . 16
Figure C.2 – Test set up for measurement of insulation resistance external coupled
induction lamp . 16
Figure F.1 – Temperature test point of internal coupled induction lamp (operating
frequency 2 500 kHz to 3 000 kHz) . 22
Figure F.2 – Temperature test point of internal coupled induction lamp (operating
frequency 120 kHz to 145 kHz) . 23
Figure F.3 – Temperature test points of external coupled induction lamp (operating
frequency 225 kHz to 275 kHz) . 24

Table 1 – Requirements for the electric strength . 10
Table B.1 – Maximum temperature at measurement point(s) under operating condition . 15
Table D.1 – Maximum operating voltage of induction lamps between lamp terminals
and between lamp terminals and ground . 17
Table D.2 – Maximum voltage between lamp terminals . 18
Table E.1 – Heating test temperature levels . 19
Table F.1 – Maximum temperature rise of the lamp temperature test points . 21
Table F.2 – Dimensions of the heat sink of internally coupled induction lamps . 23

– 4 – 62532  IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FLUORESCENT INDUCTION LAMPS –
SAFETY SPECIFICATIONS
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement betwee
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.