Double-capped fluorescent lamps - Performance specifications

2016-01-19: If the vote is accepted update directive information in mother standard.
Common modifications intended for merge with PR=60123 & then transformed to homegrown AMD, as mother EN published as IEC identical
2021: CLC legacy converted by DCLab NISOSTS

Zweiseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise

Lampes à fluorescence à deux culots - Prescriptions de performance

Fluorescenčne sijalke z dvema vznožkoma - Zahteve glede tehničnih lastnosti - Dopolnilo A11

General Information

Status
Published
Publication Date
10-May-2018
Withdrawal Date
25-Feb-2021
Current Stage
6060 - Document made available - Publishing
Start Date
11-May-2018
Completion Date
11-May-2018

Relations

Buy Standard

Amendment
EN 60081:1999/A11:2018
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2018
)OXRUHVFHQþQHVLMDONH]GYHPDY]QRåNRPD=DKWHYHJOHGHWHKQLþQLKODVWQRVWL
'RSROQLOR$
Double-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à deux culots - Spécifications de performance
Ta slovenski standard je istoveten z: EN 60081:1998/A11:2018
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60081:1998/A11

NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2018
ICS 29.140.30
English Version
Double-capped fluorescent lamps - Performance specifications
Lampes à fluorescence à deux culots - Prescriptions de Zweiseitig gesockelte Leuchtstofflampen - Anforderungen
performance an die Arbeitsweise
This amendment A11 modifies the European Standard EN 60081:1998; it was approved by CENELEC on 2018-02-26. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60081:1998/A11:2018 E

European foreword
This document (EN 60081:1998/A11:2018) has been prepared by CLC/TC 34 "Lamps and related
equipment".
The following dates are fixed:
– latest date by which this document has to be (dop) 2019-02-26
implemented at national level
by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting (dow) 2021-02-26
with this document have to be withdrawn
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 60081:1997 and its amendments are prefixed “Z”.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Regulation(s).
For the relationship with EU Regulations see informative Annex ZZA and Annexe ZZB, which are
integral part of this document.
This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
and EU Regulation 874/2012 while conformity assessment (sampling, conformity procedures as well
as limits) for market surveillance are specified in the text of the above Regulations.
CONTENTS Replacement of Annex ZA of EN 60081:1998:

Annex ZA (normative) Normative references to international publications with
their corresponding European publications
Add the following annexes:
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 245/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 874/2012

1.Z1 Add the following clause before Subclause 1.3
1.Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
1.4.Z1 After 1.4.11 add new definitions 1.4.Z1 up to 1.4.Z3:
1.4.Z1
efficacy
‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’ (η )
source
quotient of the luminous flux emitted (Ф) by the power consumed by the source
(Psource). ηsource = Ф / Psource. Unit: lm/W
Note 1 to entry: The power dissipated by auxiliary equipment such as ballasts is not included in the
power consumed by the source.
[SOURCE: Regulation 245/2009 Annex II, 1.a)]
1.4.Z2
lamp lumen maintenance factor (LLMF)
ratio of the luminous flux emitted by the lamp at a given time in its life to the initial
luminous flux
[SOURCE: Regulation 245/2009 Annex II, 1.b)]
1.4.Z3
lamp survival factor (LSF)
fraction of the total number of lamps which continue to operate at a given time under
defined conditions and switching frequency
[SOURCE: Regulation 245/2009 Annex II, 1.c)]
1.5.6 Before the text in 1.5.6, add a new Subclause 1.5.6.Z1
1.5.6.Z1 General
After 1.5.6.Z1 add new Subclauses 1.5.6.Z2 and 1.5.6.Z3 as follows:
1.5.6.Z2 Chromaticity, correlated colour temperature and colour rendering
index
The chromaticity coordinates and correlated colour temperature of an individual lamp
shall be calculated according to CIE 15 from a measurement made under the
conditions of Annex B.
The colour rendering index of an individual lamp shall be calculated according to
CIE 13.3 from a measurement made under the conditions of Annex B.
1.5.6.Z3 Efficacy
The efficacy of an individual lamp shall be calculated from a measurement of luminous
flux and power according to the conditions of Annex B.
1.5.7 Replace text of 1.5.7 with new Subclauses 1.5.7.Z1 and 1.5.7.Z2 as follows:
1.5.7.Z1 Lamp lumen maintenance factor
The lamp lumen maintenance factor of an individual lamp shall be calculated from
measurements of its luminous flux made at appropriate times according to the
conditions of Annex B. Lamp operation between these measurements shall be as
prescribed in Annex C.
1.5.7.Z2 Lamp survival
The survival of an individual lamp shall be determined by operating lamps under the
conditions prescribed in Annex C until the lamp fails to remain alight or delivers low
light output (in case of doubt, low light output refers to noticeably less than 50 % of
rated light output).
1.5.Z1 After 1.5.8 add new Subclause 1.5.Z1
1.5.Z1 Mercury content
The average mercury content shall be measured in accordance with the CV AAS
method as described in EN 62321-4. Lamp sample preparation shall be in accordance
with EN 62554.
B.1.3.Z.1 Before the text in B.1.3, add a new Subclause B.1.3.Z1
B.1.3.Z1 General
After B.1.3.Z1 add new Subclause B.1.3.Z.2
B.1.3.Z.2 Measurement ballast
For lamps that are specified for operation on both a.c. mains frequencies and high
frequency, the information given on the data sheet for “HF measurement ballast
characteristics” defines the reference ballast for HF operation.
Bibliography After 1.7 Add:
Bibliography
COMMISSION REGULATION (EC) No 245/2009 of 18 March 2009 implementing
Directive 2005/32/EC of the European Parliament and of the Council with regard to
ecodesign requirements for fluorescent lamps without integrated ballast, for high
intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,
and repealing Directive 2000/55/EC of the European Parliament and of the Council
COMMISSION REGULATION (EU) No 874/2012 of 12 July 2012 supplementing
Directive 2010/30/EU of the European Parliament and of the Council with regard to
energy la
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.