Primary batteries - Part 3: Watch batteries

IEC 60086-3:2011(E) specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard.

Primärbatterien - Teil 3: Uhrenbatterien

Piles électriques - Partie 3: Piles pour montres

L'IEC 60086-3:2011 spécifie les dimensions, la désignation, les méthodes d'essais et les exigences pour les piles électriques pour montres. Dans plusieurs cas, il est proposé des options pour les méthodes d'essai. Lorsque le fabricant présente les caractéristiques électriques et/ou les performances de la pile, il précise la méthode d'essai utilisée. Cette troisième édition annule et remplace la deuxième édition (2004) et constitue une révision technique. Les principales modifications techniques par rapport à l'édition précédente sont les dessins, une révision du tableau des systèmes électrochimiques et une harmonisation de l'article relatif au marquage avec les autres normes de la série CEI 60086. De plus, le tableau concernant les niveaux de fuite a été enrichi par l'ajout de dessins avec une meilleure visualisation. La présente publication est une norme double logo. Le contenu du corrigendum de Septembre 2011 ont été inclus dans cette copie. La présente version bilingue (2014-01) correspond à la version anglaise monolingue publiée en 2011-01. Mots clés: d'essais et les exigences pour les piles électriques pour montres

Primarne baterije - 3. del: Baterije za zapestne ure (IEC 60086-3:2011)

Ta del IEC 60086 določa mere, označevanje, metode preskušanja in zahteve za primarne baterije za zapestne ure. V več primerih je naveden cel meni preskusnih metod. Proizvajalec mora pri predstavljanju električnih značilnosti baterij in/ali podatkov o delovanju navesti uporabljeno preskusno metodo.

General Information

Status
Withdrawn
Publication Date
24-Mar-2011
Withdrawal Date
01-Mar-2014
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
29-Jun-2019
Completion Date
29-Jun-2019

Relations

Buy Standard

Standard
EN 60086-3:2011
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2011
1DGRPHãþD
SIST EN 60086-3:2005
Primarne baterije - 3. del: Baterije za zapestne ure (IEC 60086-3:2011)
Primary batteries - Part 3: Watch batteries (IEC 60086-3:2011)
Primärbatterien - Teil 3: Uhrenbatterien (IEC 60086-3:2011)
Piles primaires - Partie 3: Piles pour montres (CEI 60086-3:2011)
Ta slovenski standard je istoveten z: EN 60086-3:2011
ICS:
29.220.10 3ULPDUQLþOHQLLQEDWHULMH Primary cells and batteries
39.040.10 Zapestne, žepne ure Watches
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 60086-3
NORME EUROPÉENNE
March 2011
EUROPÄISCHE NORM
ICS 29.220.10; 39.040.10 Supersedes EN 60086-3:2005

English version
Primary batteries -
Part 3: Watch batteries
(IEC 60086-3:2011)
Piles primaires -  Primärbatterien -
Partie 3: Piles pour montres Teil 3: Uhrenbatterien
(CEI 60086-3:2011) (IEC 60086-3:2011)

This European Standard was approved by CENELEC on 2011-03-02. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60086-3:2011 E
Foreword
The text of document 35/1286/FDIS, future edition 3 of IEC 60086-3, prepared by IEC TC 35, Primary
cells and batteries, and ISO TC 114, Horology, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 60086-3 on 2011-03-02.
This European Standard supersedes EN 60086-3:2005.
The major technical changes with respect to EN 60086-3:2005 are the drawings, a review of the table of
electrochemical systems and a harmonization of the marking clause with the other standards of the
EN 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better
visualization.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-12-02
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-03-02
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60086-3:2011 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 60068-2-78:2001 NOTE  Harmonized as EN 60068-2-78:2001 (not modified).
__________
- 3 - EN 60086-3:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

1)
IEC 60086-1 2011 Primary batteries - EN 60086-1 201X
Part 1: General
1)
IEC 60086-2 2011 Primary batteries - EN 60086-2 201X
Part 2: Physical and electrical specifications

IEC 60086-4 2007 Primary batteries - EN 60086-4 2007
Part 4: Safety of lithium batteries

1)
IEC 60086-5 2011 Primary batteries - EN 60086-5 200X
Part 5: Safety of batteries with aqueous
electrolyte
IEC 60410 - Sampling plans and procedures for inspection - -
by attributes
ISO 2859 series Sampling procedures for inspection by - -
attributes
ISO 3951 series Sampling procedures for inspection by - -
variables
1)
To be published.
IEC 60086-3
Edition 3.0 2011-01
INTERNATIONAL
STANDARD
Primary batteries –
Part 3: Watch batteries
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 29.220.10; 39.040.10 ISBN 978-2-88912-330-8

– 2 – 60086-3  IEC:2011(E)
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 Physical requirements . 8
4.1 Battery dimensions, symbols and size codes . 8
4.2 Terminals . 10
4.3 Projection of the negative terminal (h ) . 10
4.4 Shape of negative terminal . 10
4.5 Mechanical resistance to pressure . 11
4.6 Deformation . 11
4.7 Leakage . 12
4.8 Marking . 12
4.8.1 General . 12
4.8.2 Disposal . 12
5 Electrical requirements . 12
5.1 Electrochemical system, nominal voltage, end-point voltage and open-circuit
voltage . 12
5.2 Closed circuit voltage U (CCV), internal resistance and impedance . 13
cc
5.3 Capacity . 13
5.4 Capacity retention . 13
6 Sampling and quality assurance . 13
6.1 Sampling . 13
6.1.1 Testing by attributes . 13
6.1.2 Testing by variables . 14
6.2 Product quality indices . 14
7 Test methods . 14
7.1 Shape and dimensions . 14
7.1.1 Shape requirement . 14
7.2 Electrical characteristics . 14
7.2.1 Environmental conditions . 14
7.2.2 Equivalent circuit – effective internal resistance – DC method . 14
7.2.3 Equipment . 15
7.2.4 Measurement of open-circuit voltage U (OCV) and closed circuit
oc
voltage U (CCV) . 16
cc
7.2.5 Calculation of the internal resistance R . 17
i
7.2.6 Measurement of the capacity . 17
7.2.7 Calculation of the internal resistance R during discharge in case of
i
method A (optional) . 19
7.3 Test methods for determining the resistance to leakage . 20
7.3.1 Preconditioning and previous examination . 20
7.3.2 High temperature and humidity test . 21
7.3.3 Test by temperature cycles . 21
8 Visual examination and acceptance conditions . 22
8.1 Preconditioning . 22

60086-3  IEC:2011(E) – 3 –
8.2 Magnification . 22
8.3 Lighting . 22
8.4 Leakage levels and classification . 22
8.5 Acceptance conditions . 24
Annex A (normative) Designation . 25
Bibliography . 26

Figure 1 – Dimensional drawing . 8
Figure 2 – Shape of negative terminal . 11
Figure 3 – Shape requirement . 14
Figure 4 – Schematic voltage transient . 15
Figure 5 – Curve: U = f(t) . 16
Figure 6 – Circuitry principle . 16
Figure 7 – Circuitry principle for method A . 18
Figure 8 – Circuitry principle for method B . 19
Figure 9 – Test by temperature cycles . 21

Table 1 – Dimensions and size codes . 9
Table 2 – Dimensions and size codes . 10
Table 3 – Minimum values of l . 11
Table 4 – Applied force F by battery dimensions . 11
Table 5 – Standardised electrochemical systems . 13
Table 6 – Test method for U (CCV) measurement . 17
cc
Table 7 – Test method A for U (CCV) measurement . 18
cc
Table 8 – Discharge resistance (values) . 20
Table 9 – Storage conditions for the recommended test . 21
Table 10 – Storage conditions for optional test . 21
Table 11 – Leakage levels and classification . 23
...

Questions, Comments and Discussion