Passive filter units for electromagnetic interference suppression - Part 2: Sectional specification: Passive filter units for which safety tests are appropriate - Test methods and general requirements

applies to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification EN 60939-1. The scope of this Sectional specification is restricted to passive filter units for which safety tests are appropriate. This implies that filters specified according to this Sectional specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required.

Passive Filter für die Unterdrückung von elektromagnetischen Störungen - Teil 2: Rahmenspezifikation: Filter, für die Sicherheitsprüfungen vorgeschrieben sind - Prüfverfahren und allgemeine Anforderungen

Filtres passifs d'antiparasitage - Partie 2: Spécification intermédiaire: Filtres passifs pour lesquels des essais de sécurité sont appropriés - Méthodes d'essai et règles générales

L'IEC 60939-2:2005 s’applique aux filtres passifs d’antiparasitage qui entrent dans le domaine d’application de la spécification générique IEC 60939-1. Le domaine d’application de la présente spécification intermédiaire est restreint aux filtres passifs pour lesquels des essais de sécurité sont appropriés. Par conséquent, les filtres spécifiés selon la présente spécification intermédiaire sont connectés aux réseaux d’alimentation, lorsque la conformité aux essais obligatoires présentés dans le Tableau 3 est nécessaire, ou sont utilisés dans d’autres endroits du circuit pour lesquels la spécification de l’équipement prescrit que tout ou partie de ces essais de sécurité est exigé. La présente spécification intermédiaire s’applique aux filtres passifs connectés à un réseau d’alimentation en courant alternatif ou à une autre alimentation dont la tension nominale ne dépasse pas 1 000 V en courant alternatif, et dont la fréquence nominale ne dépasse pas 400 Hz ou 1 000 V en courant continu. Les principales modifications effectuées entre la première et la seconde édition comprennent: – Les mesurages de la capacité et de la tangente de l’angle de perte (tan δ), la résistance de ligne continue ou la chute de tension continue au courant assigné, la tension de choc, l’inflammabilité passive, la surcharge de courant, la résistance du marquage au solvant, la résistance des composants au solvant et l’inflammabilité active ont été ajoutés à l’Article 4, procédures d’essai et de mesure. Le contenu du corrigendum de novembre 2005 a été inclus dans la présente copie.

Pasivni filtri za dušenje elektromagnetnega motenja – 2. del: Področna specifikacija: Pasivni filtri, za katere varnostni preskusi ustrezajo – Preskusne metode in splošne zahteve (IEC 60939-2:2005)

Standard se uporablja za pasivne filtre za dušenje elektromagnetnega motenja, ki spadajo v področje uporabe splošnih specifikacij standarda EN 60939-1. Področje uporabe te področne specifikacije je omejeno na pasivne filtre, za katere so ustrezni varnostni preskusi. To pomeni, da se filtri, določeni v skladu s to področno specifikacijo, priključijo na omrežno napajanje, kadar je zahtevana skladnost z obveznimi preskusi iz preglednice 3, ali se uporabijo na drugih mestih v tokokrogu, za katera specifikacija opreme predpisuje, da so zahtevani nekateri ali vsi ti varnostni preskusi.

General Information

Status
Published
Publication Date
07-Apr-2005
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
08-Apr-2020

Relations

Buy Standard

Standard
EN 60939-2:2005
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI SIST EN 60939-2:2005

STANDARD
december 2005
Pasivni filtri za dušenje elektromagnetnega motenja – 2. del: Področna
specifikacija: Pasivni filtri, za katere varnostni preskusi ustrezajo – Preskusne
metode in splošne zahteve (IEC 60939-2:2005)
Passive filter units for electromagnetic interference suppression – Part 2: Sectional
specification: Passive filter units for which safety tests are appropriate – Test
methods and general requirements (IEC 60939-2:2005)
ICS 31.160 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD EN 60939-2
NORME EUROPÉENNE
EUROPÄISCHE NORM April 2005
ICS 31.160 Supersedes EN 133200:1999

English version
Passive filter units for electromagnetic interference suppression
Part 2: Sectional specification:
Passive filter units for which safety tests are appropriate –
Test methods and general requirements
(IEC 60939-2:2005)
Filtres passifs d'antiparasitage Passive Filter für die Unterdrückung von
Partie 2: Spécification intermédiaire: elektromagnetischen Störungen
Filtres passifs pour lesquels des essais Teil 2: Rahmenspezifikation:
de sécurité sont appropriés – Filter, für die Sicherheitsprüfungen
Méthodes d'essai et règles générales vorgeschrieben sind –
(CEI 60939-2:2005) Prüfverfahren und allgemeine
Anforderungen
(IEC 60939-2:2005)
This European Standard was approved by CENELEC on 2005-03-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60939-2:2005 E
Foreword
The text of document 40/1510/FDIS, future edition 2 of IEC 60939-2, prepared by IEC TC 40,
Capacitors and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote
and was approved by CENELEC as EN 60939-2 on 2005-03-01.
This European Standard supersedes EN 133200:1999.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-03-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60939-2:2005 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 60939-2:2005
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE Where an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
1) 2)
IEC 60060-1 - High-voltage test techniques HD 588.1 S1 1991
Part 1: General definitions and test
requirements
1) 2)
IEC 60062 - Marking codes for resistors and EN 60062 2005
capacitors
1) 2)
IEC 60068-1 - Environmental testing EN 60068-1 1994
Part 1: General and guidance
1) 2)
IEC 60068-2-17 - Part 2: Tests - Test Q: Sealing EN 60068-2-17 1994

1) 2)
IEC 60085 - Electrical insulation - Thermal EN 60085 2004
classification
1) 2)
IEC 60335-1 - Household and similar electrical EN 60335-1 2002
2)
(mod) appliances - Safety + A11 2004
Part 1: General requirements
1)
IEC 60384-9 - Fixed capacitors for use in electronic - -
equipment. Part 9: Sectional
specification: Fixed capacitors of ceramic
dielectric, Class 2.
1)
IEC 60384-14 - Part 14: Sectional specification: Fixed - -
capacitors for electromagnetic
interference suppression and connection
to the supply mains
IEC 60664 Series Insulation coordination for equipment EN 60664 Series
within low-voltage systems
1) 2)
IEC 60938-1 - Fixed inductors for electromagnetic EN 60938-1 1999
interference suppression
Part 1: Generic specification
1) 2)
IEC 60939-1 - Passive filter units for electromagnetic EN 60939-1 2005
interference suppression
Part 1: Generic specification
1)
Undated reference.
2)
Valid edition at date of issue.

Publication Year Title EN/HD Year
1)
IEC 60940 - Guidance information on the application - -
of capacitors, resistors, inductors and
complete filter units for radio interference
suppression
1) 2)
IEC 61140 - Protection against electric shock - EN 61140 2002
Common aspects for installation and
equipment
INTERNATIONAL IEC
STANDARD 60939-2
Second edition
2005-02
Passive filter units for electromagnetic
interference suppression –
Part 2:
Sectional specification –
Passive filter units for which safety
tests are appropriate –
Test methods and general requirements
© IEC 2005 ⎯ Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale
X
International Electrotechnical Commission
Международная Электротехническая Комиссия
For price, see current catalogue

– 2 – 60939-2  IEC:2005(E)
CONTENTS
FOREWORD.4

1 General .6
1.1 Scope.6
1.2 Normative references .6
1.3 Information to be given in a detail specification .7
1.4 Definitions .8
1.5 Marking .9
2 Preferred ratings and characteristics.10
2.1 Preferred characteristics.10
2.2 Preferred values of ratings.10
3 Quality assessment procedures .11
3.1 Primary stage of manufacture .11
3.2 Structurally similar filters .11
3.3 Certified records of released lots.11
3.4 Approval testing.11
3.5 Quality conformance inspection .13
4 Test and measurement procedures .18
4.1 Earth inductors incorporated in filters .18
4.2 Capacitance and tan δ measurements.18
4.3 Visual examination and check of dimensions .18
4.4 Voltage proof.19
4.5 Insulation resistance.20
4.6 DC line resistance or voltage drop at rated current .20
4.7 Insertion loss.21
4.8 Discharge resistance .21
4.9 Robustness of terminations.22
4.10 Resistance to soldering heat.22
4.11 Solderability .22
4.12 Rapid change of temperature .22
4.13 Vibration.23
4.14 Bump .23
4.15 Shock.24
4.16 Container sealing .24
4.17 Climatic sequence .25
4.18 Damp heat, steady state .26
4.19 Temperature rise .26
4.20 Impulse voltage .28
4.21 Endurance.29
4.22 Charge and discharge.31
4.23 Passive flammability .32
4.24 Current overload.32
4.25 Solvent resistance of the marking .32
4.26 Component solvent resistance .33
4.27 Active flammability.33

60939-2 © IEC:2005(E) – 3 –
Annex A (normative) Test schedule for qualification approval – Assessment level D / DZ .34
Annex B (normative) Test schedule for safety requirements only.38
Annex C (normative) Circuit for the impulse voltage test .40
Annex D (normative) Circuit for the endurance test.42
Annex E (normative) Declaration of design .43

Figure 1 – Impulse wave form .29
Figure C.1 – Impulse voltage test circuit.40

Table 1 – Classification of class X capacitors .8
Table 2 – Classification of class Y capacitors .9
Table 3 – Tests concerning safety requirements only.14
Table 4 – Sampling plan – Safety and performance tests qualification approval –
Assessment level D / DZ .15
Table 5 – Lot-by-lot-tests – Assessment level D / DZ .16
Table 6 – Lot-by-lot test – Safety tests only approval.16
Table 7 – Periodic tests – Assessment level D / DZ .17
Table 8 – Creepage distances and clearances.18
Table 9 – Voltage proof.19
Table 10 – Insulation resistance.20
Table 11 – Preferred severities .
...

Questions, Comments and Discussion