EN 61207-7:2013/AC:2015
(Corrigendum)Expression of performance of gas analyzers - Part 7: Tuneable semiconductor laser gas analyzers
- BACK
- 16-Jun-2015
- 19.040
- 71.040.40
- CLC/TC 65X
Expression of performance of gas analyzers - Part 7: Tuneable semiconductor laser gas analyzers
Angabe zum Betriebsverhalten von Gasanalysatoren - Teil 7: Gasanalysatoren mit abstimmbaren Halbleiterlasern
Expression des performances des analyseurs de gaz - Partie 7: Analyseurs de gaz laser à semi-conducteurs accordables
Prikaz lastnosti analizatorjev plina - 7. del: Analizatorji plina z nastavljivim polprevodniškim laserjem
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Prikaz lastnosti analizatorjev plina - 7. del: Analizatorji plina z nastavljivim polprevodniškim laserjemAngabe zum Betriebsverhalten von Gasanalysatoren - Teil 7: Gasanalysatoren mit abstimmbaren HalbleiterlasernExpression des performances des analyseurs de gaz - Partie 7: Analyseurs de gaz laser à semi-conducteurs accordablesExpression of performance of gas analyzers - Part 7: Tunable semiconductor laser gas analyzer71.040.40Kemijska analizaChemical analysisICS:Ta slovenski standard je istoveten z:EN 61207-7:2013/AC:2015SIST EN 61207-7:2014/AC:2015en,fr01-november-2015SIST EN 61207-7:2014/AC:2015SLOVENSKI
STANDARD
SIST EN 61207-7:2014/AC:2015
IEC 61207-7:2013/COR1:2015 – 1 –
IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE ____________
IE
...
This May Also Interest You
IEC 61207-3:2019 is available as IEC 61207-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61207-3:2019 applies to the three main methods for measuring oxygen by its paramagnetic property, which are outlined in the introduction. It considers essential ancillary units and applies to analyzers installed indoors and outdoors. Safety-critical applications can require additional requirements from system and analyzer specifications not covered in this document. This document is intended: - to specify terminology and definitions related to the functional performance of paramagnetic gas analyzers for the measurement of oxygen in a source gas; - to unify methods used in making and verifying statements on the functional performance of such analyzers; - to specify what tests are performed to determine the functional performance and how such tests are carried out; - to provide basic documents to support the application of internationally recognized quality management standards. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) all references (normative and informative) have been updated, deleted or added to as appropriate; b) all the terms, descriptions and definitions relating to the document have been updated where appropriate; c) all references to “errors” have been replaced by “uncertainties” and appropriate updated definitions applied.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Aug-2019
- 30-Jul-2022
- 19.040
- 71.040.40
- CLC/TC 65X
IEC 61207-7:2013 includes the terminology, definitions, statements and tests that are specific to tuneable semiconductor laser gas analyzers, which utilize tuneable semiconductor laser absorption spectroscopy (TSLAS). It applies to all aspects of analyzers utilizing TSLAS for the concentration measurement of one or more gas components in a gaseous mixture or vapour. It applies to analyzers utilizing tuneable semiconductor lasers as sources and utilizing absorption spectroscopy, such as direct absorption, FMS, WMS, multi-pass absorption spectroscopy, CRDS, ICOS, PAS and CEAS techniques, etc.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Jan-2014
- 29-Oct-2016
- 19.040
- 71.040.40
- CLC/TC 65X
IEC 61207-3:2019 is available as IEC 61207-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61207-3:2019 applies to the three main methods for measuring oxygen by its paramagnetic property, which are outlined in the introduction. It considers essential ancillary units and applies to analyzers installed indoors and outdoors. Safety-critical applications can require additional requirements from system and analyzer specifications not covered in this document. This document is intended: - to specify terminology and definitions related to the functional performance of paramagnetic gas analyzers for the measurement of oxygen in a source gas; - to unify methods used in making and verifying statements on the functional performance of such analyzers; - to specify what tests are performed to determine the functional performance and how such tests are carried out; - to provide basic documents to support the application of internationally recognized quality management standards. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) all references (normative and informative) have been updated, deleted or added to as appropriate; b) all the terms, descriptions and definitions relating to the document have been updated where appropriate; c) all references to “errors” have been replaced by “uncertainties” and appropriate updated definitions applied.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Aug-2019
- 30-Jul-2022
- 19.040
- 71.040.40
- CLC/TC 65X
IEC 61207-7:2013 includes the terminology, definitions, statements and tests that are specific to tuneable semiconductor laser gas analyzers, which utilize tuneable semiconductor laser absorption spectroscopy (TSLAS). It applies to all aspects of analyzers utilizing TSLAS for the concentration measurement of one or more gas components in a gaseous mixture or vapour. It applies to analyzers utilizing tuneable semiconductor lasers as sources and utilizing absorption spectroscopy, such as direct absorption, FMS, WMS, multi-pass absorption spectroscopy, CRDS, ICOS, PAS and CEAS techniques, etc.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Jan-2014
- 29-Oct-2016
- 19.040
- 71.040.40
- CLC/TC 65X
This product standard applies to wireless communication devices used at distances up to and including 200 mm from the human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or integrated into garments. The applicable frequency range is from 30 MHz to 6 GHz. The objective of this standard is to demonstrate the compliance of such devices with the basic restrictions and exposure limit values related to human exposure to radio frequency electromagnetic fields. For devices used next to the ear the applicable product standard is EN 50360:2017 [1]. For low power devices the applicable product standard is EN 50663:2017 [2].
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Aug-2023
- 11-Jan-2022
- 17.240
- 33.070.01
- 2014/53/EU
- M/536
- CLC/TC 106X
This product standard applies to wireless communication devices used in close proximity to the human ear (e.g. mobile phones, wireless headsets). The applicable frequency range is from 300 MHz to 6 GHz. The objective of this standard is to demonstrate the compliance of such devices with the basic restrictions and exposure limit values related to human exposure to radio frequency electromagnetic fields. For devices used next to the body or in front of the face the applicable product standard is EN 50566:2017. For low power devices the applicable product standard is EN 50663:2017.
- Draft3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Aug-2023
- 33.070.01
- 2014/53/EU
- M/536
- CLC/TC 106X
IEC 60728-101-1:2023 provides the requirements and describes the implementation guidelines of RF cabling for two-way home networks; it is applicable to any home network that distributes signals provided by CATV/MATV/SMATV cable networks (including individual receiving systems) having a coaxial cable output. It is also applicable to home networks where some part of the distribution network uses wireless links, for example in place of the receiver cord. This part of IEC 60728 is therefore applicable to RF cabling for two-way home networks with wired cords or wireless links inside a room and primarily intended for television and sound signals operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz band. In a building divided into apartment blocks, the distribution of the signals inside the home starts from the home network interface (HNI) up to the system outlet or terminal input. The requirements at the system outlet are given in IEC 60728-101:2016, Clause 5 and the requirements at the HNI are given in IEC 60728-101:2016, Clause 7. In Clause 5 of this document, additional requirements are given. This document deals with various possibilities to distribute signals in a home network, using coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This document gives references to basic methods of measurement of the operational characteristics of the home cable network in order to assess its performance. All requirements refer to the performance limits, which are obtained between the input(s) at the home network interface (HNI) and the output at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies to the terminal input. The present document also provides limits for the accumulation of degradations if the home network is subdivided into a number of parts, using different transmission media (e.g. coaxial cabling, balanced cabling, optical cabling, wireless links). Clause 5 defines the performance limits measured at system outlet or terminal input for an unimpaired (ideal) test signal applied at the HNI. Under normal operating conditions for any digital channel and meeting these limits, the cumulative effect of the impairment of any single parameter at the HNI and that due to the home network produces signals not worse than the requirements given in IEC 60728-101-2. For digitally modulated signals, the quality requirement is a QEF (quasi error-free) reception. This document describes the physical layer connection for home networks. Description of protocols required for layer 2 and higher layers is out of the scope of this document. Logical connections between devices within the home network are therefore not always guaranteed. This International Standard is to be used in conjunction with IEC 60728-101:2016.
- Draft68 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft2 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60728-101-2:2023 provides the minimum performance requirements to be fulfilled in operation at the system outlet or terminal input and describes the summation criteria for the impairments present in the received signals and those produced by the CATV/MATV/SMATV cable network, including individual receiving systems. In a building divided into apartment blocks, the signals received by the antennas are distributed by the MATV/SMATV cable network up to the home network interface (HNI); the television signals are then distributed (inside the home) by home networks (HN) of various types up to the system outlet or terminal input. The cable network can support two-way operation, from the system outlet (or terminal input) towards the headend. The home network can use coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This part of IEC 60728 is limited to downstream TV broadcast signals received from antennas and is applicable to cable networks intended for television signals, sound signals and interactive services operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for home distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz frequency band. The main sections of a general CATV/MATV/SMATV system, indicating the parts of the IEC 60728-101 series documents where the relevant performance requirements are indicated. - The requirements for the signals received at the headend are given in IEC 60728-101:2016, Clause 6. - The requirements for the CATV/MATV/SMATV cable network, assuming an unimpaired input signal at the input of the headend, up to the system outlet are given in IEC 60728‑101:2016, Clause 5. - The requirements for the CATV/MATV/SMATV cable network up to the home network interface (HNI) are given in IEC 60728-101:2016, Clause 7, assuming an unimpaired input signal at the input of the headend. - The specific requirements from HNI to the system outlet or terminal input are given in IEC 60728-101-1:2023, Clause 5, assuming an unimpaired input signal at the HNI. - The requirements at the system outlet in operation are given in Clause 6 of this document. The expression "in operation" means that the received signals, with their impairments, are applied to the headend input of the CATV/MATV/SMATV cable network. The requirements at the system outlet "in operation" are derived, therefore, by summing the impairments of the various cascaded parts of the system and of the input signal. When a change of signal format from digital to digital (e.g. from QPSK to QAM) (e.g. as in ETSI EN 300 473) or from digital to analogue (e.g. from DVB-S/S2 to AM-VSB or DVB-T/T2 to AM-VSB) is made at the headend, the summation of the impairments that produce a relaxation of requirements at system outlet does not apply. Such a case will be the equivalence of unimpaired signals applied at the headend input. Therefore, the requirements at system outlet given in IEC 60728‑1 apply. This document also provides references for the basic methods of measurement of the operational characteristics of the downstream cable network in order to assess its performance. All requirements refer to the performance limits to be achieved in operation at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not
- Draft29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.