(Main)Connectors for use in d.c., low-frequency analogue and digital high speed data applications - Part 3-100: Rectangular connectors with assessed quality - Detail specification for a range of shielded connectors with trapezoidal-shaped shells and non-removable ribbon contacts on a 1,27 mm double row
Connectors for use in d.c., low-frequency analogue and digital high speed data applications - Part 3-100: Rectangular connectors with assessed quality - Detail specification for a range of shielded connectors with trapezoidal-shaped shells and non-removable ribbon contacts on a 1,27 mm double row
IEC 61076-3-100:1999 applies to a range of shielded two-part connectors with trapezoidal-shaped shells and non-removable ribbon contacts on 1,27 mm double rows. The fixed connectors are provided with a post either for dip solder (type A, B, C, D) or non-accessible insulation displacement terminations (type E). The free connectors are provided with non-accessible insulation displacement terminations.
Steckverbinder für Gleichspannungs- und Niederfrequenzanwendungen sowie digitale Anwendungen mit hoher Übertragungsrate - Teil 3-100: Rechteckige Steckverbinder mit bewerteter Qualität - Bauartspezifikation für eine Reihe von geschirmten Steckverbindern mit trapezförmigen Kragen und nicht auswechselbaren Streifenkontakten in einem Raster von 1,27 mm, doppelreihig
Connecteurs pour applications analogiques en courant continu et à basse fréquence et pour applications numériques utilisant des débits élevés pour le transfert des données - Partie 3-100: Connecteurs rectangulaires sous assurance de la qualité - Spécification particulière pour une famille de connecteurs blindés à boîtiers trapézoïdaux, deux rangées au pas de 1,27 mm et contacts à lame, non démontables
IEC 61076-3-100:1999 s'applique à une famille de connecteurs blindés en deux parties avec boîtiers trapézoïdaux et contacts méplats fixes sur double rangée au pas de 1,27 mm. Les embases sont fournies avec une borne soit pour soudage à la vague (type A, B, C, D) soit pour des sorties autodénudantes non accessibles (type E). Les fiches sont fournies avec des sorties autodénudantes non accessibles.
Connectors with assessed quality, for use in d.c., low frequency analogue and digital high-speed data applications - Part 3-100: Rectangular connectors with assessed quality - Detail specification for a range of shielded connectors with trapezoidal-shaped shells and non-removable ribbon contacts on a 1.27 mm double row (IEC 61076-3-100:1999)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2002
Connectors with assessed quality, for use in d.c., low frequency analogue and
digital high-speed data applications - Part 3-100: Rectangular connectors with
assessed quality - Detail specification for a range of shielded connectors with
trapezoidal-shaped shells and non-removable ribbon contacts on a 1.27 mm
double row (IEC 61076-3-100:1999)
Connectors for use in d.c., low-frequency analogue and digital high speed data
applications -- Part 3-100: Rectangular connectors with assessed quality - Detail
specification for a range of shielded connectors with trapezoidal-shaped shells and non-
removable ribbon contacts on a 1,27 mm double row
Steckverbinder für Gleichspannungs- und Niederfrequenzanwendungen sowie digitale
Anwendungen mit hoher Übertragungsrate -- Teil 3-100: Rechteckige Steckverbinder mit
bewerteter Qualität - Bauartspezifikation für eine Reihe von geschirmten Steckverbindern
mit trapezförmigen Kragen und nicht auswechselbaren Streifenkontakten in einem
Raster von 1,27 mm, doppelreihig
Connecteurs pour applications analogiques en courant continu et à basse fréquence et
pour applications numériques utilisant des débits élevés pour le transfert des données --
Partie 3-100: Connecteurs rectangulaires sous assurance de la qualité - Spécification
particulière pour une famille de connecteurs blindés à boîtiers trapézoïdaux, deux
rangées au pas de 1,27 mm et contacts à lame, non démontables
Ta slovenski standard je istoveten z: EN 61076-3-100:2000
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME CEI
INTERNATIONALE IEC
61076-3-100
INTERNATIONAL
QC 480201XX0001
STANDARD
Première édition
First edition
1999-11
Connecteurs pour applications analogiques
en courant continu et à basse fréquence et pour
applications numériques utilisant des débits
élevés pour le transfert des données –
Partie 3-100:
Connecteurs rectangulaires sous assurance de la qualité –
Spécification particulière pour une famille de connecteurs
blindés à boîtiers trapézoïdaux, deux rangées au pas
de 1,27 mm et contacts à lame, non démontables
Connectors for use in d.c., low-frequency analogue
and digital high speed data applications –
Part 3-100:
Rectangular connectors with assessed quality –
Detail specification for a range of shielded connectors
with trapezoidal-shaped shells and non-removable ribbon
contacts on a 1,27 mm double row
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photo-copie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
X
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
61076-3-100 IEC:1999 – 3 –
CONTENTS
Page
FOREWORD . 7
Clause
1 General data . 11
1.1 Recommended method of mounting . 11
1.1.1 Minimum and maximum number of contacts . 11
1.2 Rating and characteristics . 11
1.3 Normative references. 13
1.4 Marking. 15
1.5 IEC type designation . 15
1.6 Ordering information . 19
2 Technical data. 19
2.1 General. 19
2.2 Survey of styles and variants. 19
2.3 Information on application . 19
3 Dimensional information . 19
3.1 General. 19
3.2 Isometric view and common features (with locking devices). 21
3.3 Mating information . 21
3.3.1 Contact arrangements . 21
3.3.2 Mating face dimensions. 25
3.3.3 Contact mating dimensions. 29
3.4 Fixed connectors. 29
3.4.1 Dimensions . 31
3.4.2 Terminations . 41
3.5 Free connectors . 43
3.5.1 Dimensions . 43
3.5.2 Termination. 49
3.6 Accessories . 49
3.7 Mounting information. 49
3.7.1 Hole pattern on printed boards . 49
3.7.2 Panel cutout dimensions. 57
4 Characteristics . 59
4.1 Climatic category . 59
4.2 Electrical. 59
4.2.1 Creepage and clearance distance. 59
4.2.2 Voltage proof. 59
4.2.3 Current-carrying capacity. 59
4.2.4 Initial contact resistance . 59
4.2.5 Initial insulation resistance . 61
4.3 Mechanical. 61
4.3.1 Mechanical operation . 61
4.3.2 Insertion and withdrawal forces . 61
61076-3-100 IEC:1999 – 5 –
Clause Page
5 Test schedule . 63
5.1 General. 63
5.2 Test schedules. 65
5.2.1 Basic (minimum) test schedule . 65
5.2.2 Full test schedule . 65
6 Quality assessment procedures. 77
6.1 Qualification approval testing . 77
6.1.1 Method 1. 77
6.1.2 Method 2. 79
6.2 Quality conformance inspection. 79
6.2.1 Lot-by-lot tests . 79
6.2.2 Periodic tests . 79
6.3 Delayed delivery, re-inspection. 81
61076-3-100 IEC:1999 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
CONNECTORS FOR USE IN DC, LOW-FREQUENCY ANALOGUE
AND DIGITAL HIGH SPEED DATA APPLICATIONS –
Part 3-100: Rectangular connectors with assessed quality –
Detail specification for a range of shielded connectors with
trapezoidal-shaped shells and non-removable ribbon contacts
on a 1,27 mm double row
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61076-3-100 has been prepared by subcommittee 48B: Connectors,
of IEC technical committee 48: Electromechanical components and mechanical structures for
electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
48B/787/FDIS 48B/817/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
61076-3-100 IEC:1999 – 9 –
The QC number that appears on the front cover of this publication is the specification number
in the IEC Quality Assessment System for Electronic Components (IECQ).
The committee has decided that this publication remains valid until 2003. At this date, in
accordance with the committee’s decision, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
61076-3-100 IEC:1999 – 11 –
CONNECTORS FOR USE IN DC, LOW-FREQUENCY ANALOGUE
AND DIGITAL HIGH SPEED DATA APPLICATIONS –
Part 3-100: Rectangular connectors with assessed quality –
Detail specification for a range of shielded connectors with
trapezoidal-shaped shells and non-removable ribbon contacts
on a 1,27 mm double row
1 General data
1.1 Recommended method of mounting
A complete connector consists of a fixed connector mounted vertically or at a right angle to the
printed circuit board or panel mounted. The free connector is terminated to a cable consisting
of 14 to 110 conductors.
1.1.1 Minimum and maximum number of contacts
The fixed and free connectors have a range of 14 to 110 contacts. T
...