Status
Not Published
Publication Date
06-Apr-2028
Current Stage
4020 - Enquiry circulated - Enquiry
Start Date
30-Oct-2026
Due Date
04-Mar-2027
Completion Date
30-Oct-2026

Buy Documents

Draft

prEN IEC 62433-4:2026 - BARVE

English language (89 pages)
Preview
Preview
e-Library read for
×1 day

prEN IEC 62433-4:2026 is an IEC/CENELEC draft standard for EMC IC modelling. It specifies the integrated circuit immunity model for conducted RF immunity, known as ICIM-CI, so engineers can predict how disturbances applied to IC pins affect immunity at device, board, and system level.

The standard defines both the electrical model and its XML-based Conducted immunity markup language (CIML) representation. It is aimed at people who extract, exchange, simulate, or validate immunity models for integrated circuits.

What does prEN IEC 62433-4:2026 specify?

prEN IEC 62433-4:2026 specifies a flow for deriving a macro-model that simulates the conducted immunity levels of an integrated circuit. The model is used to predict immunity to conducted radio frequency (RF) disturbances applied on IC pins, and it can be used for both analogue and digital ICs.

The document is organized into clauses covering the model philosophy, the ICIM-CI model description, the CIML file format, extraction, validation, and model usage. It also includes informative annexes with examples, conversions, measurement methods, and application-level simulation cases.

AnnexWhat it covers
AExample showing the influence of a disturbance output terminal
BConversions between parameter types and transmitted power calculation
CExample ICIM-CI macro-model in CIML format
DRecommendations for using SPICE subcircuits in CIML
EPDN impedance measurement methods using a VNA
FGuidelines for specifying IB test criteria in CIML
GRFIP measurement method description
HImmunity simulation based on pass/fail test
IImmunity simulation based on non-pass/fail test

What are the key requirements of prEN IEC 62433-4:2026?

prEN IEC 62433-4:2026 is built around two linked sub-models: the passive distribution network (PDN) and the immunity behaviour (IB). In practice, the document tells you how to separate the linear path that carries the disturbance from the behavioural response that represents immunity or susceptibility.

PDN and IB must be treated as separate parts

Clause 5 describes the ICIM-CI model as two sub-models. The PDN represents the passive path of disturbances through package, pins, bondwires, tracks, and related parasitics, while the IB represents the internal response of the IC to those disturbances.

This separation matters because it lets you measure or build the pin network separately from the immunity response. It also means the model can be inserted into circuit simulation tools without merging all effects into one black box.

The PDN is a frequency-domain, mostly linear network

Clause 5.2 states that the PDN is defined in the frequency domain and may be characterized with S-parameters, Z-parameters, Y-parameters, or a SPICE-like netlist. The PDN is treated as linear, and its data must be taken under conditions where internal protection structures are not activated.

In practice, this means the PDN should be extracted in representative operating conditions, steady state, and within the voltage, temperature, load, and frequency range where the model remains valid. If the pin network is measured outside those conditions, the model may not predict immunity correctly.

Internal coupling between blocks can be modelled with IBC

Clause 5.3 introduces inter-block coupling (IBC) as a passive network that links different PDN blocks inside the IC. It is used to describe coupling between digital and analogue blocks, ground domains, substrate losses, mutual inductance, or insulation effects between internal power and ground terminals.

This matters for complex ICs where one block influences another. In practice, the model can include multiple PDN blocks and an IBC network so the simulation reflects internal coupling paths rather than treating all pins as independent.

The IB captures immunity behaviour and susceptibility thresholds

Clause 5.4 explains that the IB describes the response of the IC as a function of the disturbance applied to one or more disturbance input (DI) terminals. The IB can be built from pass/fail tests, where the immunity threshold is the result, or from non-pass/fail tests, where the behavioural response is represented more directly.

This choice matters because it changes how simulation results are interpreted. With pass/fail data, the model can directly indicate failure or pass. With non-pass/fail data, the user must apply the immunity criterion during simulation or later analysis.

CIML is the required exchange format structure

Clause 6 defines the CIML structure used to store ICIM-CI data. The file contains a header, lead definitions, SPICE macro-models, validity information, PDN data, IBC data, and IB data, with the Macromodels and Ibc sections optional.

In practice, this gives a machine-readable way to exchange the model between tools and organizations. The file structure is important because simulators and parsers depend on the exact CIML organization to interpret the model correctly.

Lead definitions must identify pin role and type

Clause 6.5 requires each lead to have an Id and a Name, and allows Mode and Type to be specified. The Mode can indicate DI, DO, OO, or GND, while internal leads are marked differently and used for coupling between blocks.

This matters because the model depends on knowing which pins are disturbed, which pins are observed, and which ones belong to internal interconnections. If the lead roles are wrong, the extracted PDN or IB will be attached to the wrong terminals.

Extraction and validation must be done under controlled conditions

Clause 7 gives the extraction conditions and the main measurement approaches. It notes environmental constraints such as normal room temperature, and it identifies PDN extraction by S-, Z-, or Y-parameter measurement or RFIP methods, and IB extraction by direct RF power injection or RFIP methods.

Clause 8 then validates two hypotheses: first, that the PDN can be represented with linear network parameters; second, that transmitted power is a useful immunity criterion. In practice, this means the model is not just measured once - its assumptions must be checked against measurement and simulation.

Model usage depends on the type of IB data

Clause 9 explains that ICIM-CI models can be used in SPICE-like simulators together with external components such as decoupling capacitors, filters, and PCB parasitics. If the IB came from a pass/fail test, failure prediction can be direct. If it came from a non-pass/fail test, the user must compare simulated transmitted power with the IB criterion to decide whether failure occurs.

This distinction matters in design work because it determines whether the model gives a binary pass/fail answer or a behavioural comparison that still needs interpretation.

What terms does prEN IEC 62433-4:2026 define?

  • Conducted immunity markup language (CIML) - The XML-based data exchange format used to store and share ICIM-CI model data.
  • Passive distribution network (PDN) - The passive part of the IC model that represents the propagation path of RF disturbances through the device.
  • Immunity behaviour (IB) - The block that describes how the IC responds to disturbances, including susceptibility behaviour.
  • Inter-block coupling (IBC) - A passive network used to model coupling between internal blocks of an IC.
  • Disturbance input (DI) - A pin where RF disturbance is injected.
  • Disturbance output (DO) - A terminal whose load affects the DI impedance and can receive part of the disturbance.
  • Observable output (OO) - The pin where the immunity criterion is monitored during testing.

Who uses prEN IEC 62433-4:2026?

prEN IEC 62433-4:2026 is used by EMC engineers, IC designers, model developers, and simulation specialists who work on RF immunity prediction. It is also relevant to test engineers who measure PDN and IB data using VNA, DPI, or RFIP methods.

Typical uses include extracting pin impedance, building SPICE-compatible macro-models, defining CIML files, validating immunity hypotheses, and simulating how an IC behaves in a board-level environment. It is relevant across integrated circuits, microelectronics, and immunity-related electromagnetic compatibility work.

What changed in prEN IEC 62433-4:2026 from the previous edition?

prEN IEC 62433-4:2026 replaces the first edition published in 2016. The foreword states that this second edition is a technical revision.

The significant changes listed are:

  • removal of annexes on preliminary definitions for XML representation and XML encoding rules
  • simplification of XML parts in the main body
  • addition of informative Annex D and Annex F with examples

Which standards are used with prEN IEC 62433-4:2026?

  • IEC 60050-131 - Provides circuit theory vocabulary used for the technical definitions in the document.
  • IEC 60050-161 - Provides electromagnetic compatibility vocabulary.
  • IEC 62132-1 - Gives the general conditions and definitions used for IC electromagnetic immunity measurement, including frequency stepping and measurement context.
  • IEC 62132-4 - Defines the direct RF power injection method used in PDN and IB extraction examples.
  • IEC 62433-1 - Provides the general modelling framework and the XML encoding rules used for CIML.
  • IEC 62433-2 - Provides the companion model for conducted emissions, which sits alongside this conducted immunity part in the IEC 62433 series.
  • CISPR 17 - Provides measurement methods for suppression characteristics and supports the VNA-based impedance measurement procedures.

What does the prEN IEC 62433-4:2026 document contain?

prEN IEC 62433-4:2026 contains detailed CIML keyword definitions and attribute tables for the Lead, PDN, and IB sections. It also includes the rules for validity information, file structure, and the use of SPICE macro-models and external library files.

The annexes add practical material rather than new core requirements. Annex B gives parameter conversion rules and power-calculation methods for single-ended and differential cases. Annex E and Annex G explain measurement setups for PDN extraction and RFIP-based immunity extraction. Annex C shows a complete CIML example for a LIN transceiver, while Annex H and Annex I show how to use ICIM-CI models in simulation to predict failure from pass/fail and non-pass/fail tests.

The figures and tables are especially useful for implementation work. They show model structure, PDN schematics, differential-input representations, extraction setups, validation examples, and the data organization needed for parser-friendly CIML files.

Relations

Effective Date
27-Jan-2026

Buy Documents

Draft

prEN IEC 62433-4:2026 - BARVE

English language (89 pages)
Preview
Preview
e-Library read for
×1 day

Frequently Asked Questions

prEN IEC 62433-4:2026 is a draft published by CLC. Its full title is "EMC IC modelling - Part 4: Models of integrated circuits for RF immunity behavioural simulation - Conducted immunity modelling (ICIM-CI)". This standard covers: EMC IC modelling - Part 4: Models of integrated circuits for RF immunity behavioural simulation - Conducted immunity modelling (ICIM-CI)

EMC IC modelling - Part 4: Models of integrated circuits for RF immunity behavioural simulation - Conducted immunity modelling (ICIM-CI)

prEN IEC 62433-4:2026 is classified under the following ICS (International Classification for Standards) categories: 31.200 - Integrated circuits. Microelectronics. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN IEC 62433-4:2026 has the following relationships with other standards: It is inter standard links to EN 62433-4:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN IEC 62433-4:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2026
Modeliranje integriranih vezij (IC) za elektromagnetno združljivost (EMC) - 4. del:
Modeli integriranih vezij za vedenjsko simulacijo RF odpornosti - Modeliranje
odpornosti integriranih vezij proti prevajanim motnjam (ICIM-CI)
EMC IC modelling - Part 4: Models of integrated circuits for RF immunity behavioural
simulation - Conducted immunity modelling (ICIM-CI)
EMV-IC-Modellierung - Teil 4: Modelle integrierter Schaltungen für die Simulation des
Verhaltens der HF-Störfestigkeit - Modellierung der Störfestigkeit gegen leitungsgeführte
Störungen (ICIM-CI)
Modèles de circuits intégrés pour la CEM - Partie 4: Modèles de circuits intégrés pour la
simulation du comportement d'immunité aux radiofréquences - Modélisation de
l'immunité conduite (ICIM-CI)
Ta slovenski standard je istoveten z: prEN IEC 62433-4:2026
ICS:
31.200 Integrirana vezja, Integrated circuits.
mikroelektronika Microelectronics
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

47A/1231/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 62433-4 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-10-30 2027-01-22
SUPERSEDES DOCUMENTS:
47A/1213/CD, 47A/1221/CC
IEC SC 47A : INTEGRATED CIRCUITS
SECRETARIAT: SECRETARY:
Japan Mr Yoshinori FUKUBA
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
Electromagnetic Compatibility
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
EMC IC modelling - Part 4: Models of integrated circuits for RF immunity behavioural
simulation - Conducted immunity modelling (ICIM-CI)

PROPOSED STABILITY DATE: 2032
NOTE FROM TC/SC OFFICERS:
All comments on 47A/1213/CD have been reviewed and resolved in 47A/1221/CC. SC47A has decided
to proceed to the CDV stage.
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, o r any part of it,
for any other purpose without permission in writing from IEC.

Link to Committee Draft for Vote (CDV) online document:
Click here
How to access
This link leads you to the Online Standards Development (OSD) platform for National Mirror
Committee’s (NMC) comments. The project draft may be found further down this document.

Resource materials
We recommend NCs to review the available materials to better understand the member commenting
on the OSD platform. This includes the:
• OSD NC roles overview
• How to add and submit comments to the IEC

Contact
Should you require any assistance, please contact the IEC IT Helpdesk.

IEC CDV 62433-4 ED2 © IEC 2026

CONTENTS
CONTENTS . 1
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms, definitions, abbreviated terms and conventions . 8
3.1 Terms and definitions. 8
3.2 Abbreviated terms . 10
3.3 Conventions . 10
4 Philosophy . 10
5 ICIM-CI model description . 11
5.1 General . 11
5.2 PDN description . 13
5.3 IBC description . 15
5.4 IB description . 16
6 CIML format . 17
6.1 General . 17
6.2 CIML structure . 18
6.3 Global keywords . 18
6.4 Header section. 18
6.5 Lead definitions . 19
6.6 SPICE macro-models . 20
6.7 Validity section . 21
6.7.1 General . 21
6.7.2 Attribute definitions . 21
6.8 PDN . 23
6.8.1 General . 23
6.8.2 Attribute definitions . 24
6.8.3 PDN for a single-ended input or output . 26
6.8.4 PDN for a differential input . 33
6.8.5 PDN multi-port description . 37
6.9 IBC . 38
6.9.1 General . 38
6.9.2 Attribute definitions . 38
6.10 IB . 39
6.10.1 General . 39
6.10.2 Attribute definitions . 40
6.10.3 Description . 45
7 Extraction . 47
7.1 General . 47
7.2 Environmental extraction constraints . 47
7.3 PDN extraction. 47
7.3.1 General . 47
7.3.2 S-/Z-/Y-parameter measurement . 47
7.3.3 RFIP test method . 48
7.4 IB extraction . 48
IEC CDV 62433-4 ED2 © IEC 2026

7.4.1 General . 48
7.4.2 Direct RF power injection test method . 48
7.4.3 RFIP test method . 52
7.4.4 IB data table . 53
7.5 IBC . 54
8 Validation of ICIM-CI hypotheses . 54
8.1 General . 54
8.2 Linearity . 55
8.3 Transmitted power as immunity criteria . 56
9 Model usage . 57
Annex A (informative) Example of an ICIM‑CI macro-model to illustrate the influence
of a disturbance output terminal . 59
Annex B (informative) Conversions between parameter types and calculation of
transmitted power . 60
B.1 General . 60
B.2 Single-ended input or output . 60
B.3 Differential input or output . 61
Annex C (informative) Example of ICIM-CI macro-model in CIML format . 65
Annex D (informative) Recommendations for using SPICE subcircuits for the PDN
component in CIML . 70
Annex E (informative) PDN impedance measurement methods using a VNA . 73
E.1 General . 73
E.2 Conventional one-port method . 73
E.3 Two-port method for low impedance measurement . 73
E.4 Two-port method for high impedance measurement . 74
Annex F (informative) Guidelines for specifying the IB test criteria in CIML . 75
Annex G (informative) RFIP measurement method description . 78
G.1 General . 78
G.2 Obtaining immunity parameters . 78
Annex H (informative) Immunity simulation with ICIM-CI model based on pass/fail test . 81
H.1 ICIM-CI macro-model of a voltage regulator IC . 81
H.1.1 General . 81
H.1.2 PDN extraction . 82
H.1.3 IB extraction . 82
H.1.4 SPICE-compatible macro-model . 82
H.2 Application level simulation and failure prediction . 83
Annex I (informative) Immunity simulation with ICIM-CI model based on non-pass/fail
test . 85
Bibliography . 87

Figure 1 – Example of the ICIM-CI model structure . 12
Figure 2 – Example of an ICIM-CI model of an electronic board . 13
Figure 3 – Example of an IBC network . 15
Figure 4 – ICIM-CI model representation with different blocks. 16
Figure 5 – CIML inheritance hierarchy . 17
Figure 6 – PDN electrical schematics . 27
Figure 7 – PDN represented as a one-port black-box . 27
IEC CDV 62433-4 ED2 © IEC 2026

Figure 8 – PDN represented with S-parameters in Touchstone® format . 30
Figure 9 – Two-port S-parameters file in Touchstone® format . 31
Figure 10 – Example structure for defining the PDN using circuit elements . 32
Figure 11 – Example of a differential input schematic . 34
Figure 12 – Example of a differential input PDN represented as a two-port black-box . 34
Figure 13 – PDN data format for differential input or output . 35
Figure 14 – Example ICIM-CI macro-model of an operational amplifier with differential
inputs . 36
Figure 15 – Example ICIM-CI model of an AND gate . 37
Figure 16 – Example IB file obtained from DPI measurement . 46
Figure 17 – Test setup of the DPI immunity measurement method as specified in IEC
62132-4 . 49
Figure 18 – Principle of DPI on single-pin and multi-pin . 50
Figure 19 – Electrical representation of the DPI test setup . 51
Figure 20 – Test setup of the RFIP measurement method derived from the DPI method . 52
Figure 21 – Example setup used for illustrating the ICIM-CI hypotheses . 55
Figure 22 – Example of linearity assumption validation . 56
Figure 23 – Example of transmitted power criterion validation . 57
Figure 24 – Example of using an ICIM-CI macro-model for simulation . 57
Figure A.1 – ICIM-CI description applied to a crystal oscillator for extracting IB . 59
Figure B.1 – Single-ended DI . 60
Figure B.2 – Differential DI . 61
Figure B.3 – Two-port representation of a differential DI . 61
Figure B.4 – Example simulation schematic of common-mode injection on a differential
DI based on DPI . 62
Figure B.5 – Equivalent common-mode input impedance of a differential DI . 62
Figure B.6 – Example simulation schematic to determine the transmitted power for a
differential DI . 63
Figure C.1 – Configuration of the example LIN transceiver for the ICIM-CI macro-model
extraction . 65
Figure C.2 – PDN data in Touchstone® format (s2p), data is measured using a VNA . 67
Figure C.3 – PDN data of leads 6 (LIN) and 7 (VCC) . 68
Figure C.4 – IB data in ASCII format (.txt), data is measured using the DPI method -
Injection on VCC pin . 68
Figure C.5 – IB data for injection on VCC pin . 69
Figure E.1 – Conventional one-port S-parameter measurement . 73
Figure E.2 – Two-port method for low impedance measurement . 73
Figure E.3 – Two-port method for high impedance measurement . 74
Figure G.1 – Test setup of the RFIP measurement method derived from the DPI
method . 78
Figure G.2 – Principle of the RFIP measurement method and the probe representation . 78
Figure H.1 – Electrical schematic for extracting the voltage regulator’s ICIM-CI . 81
Figure H.2 – ICIM-CI extraction on the voltage regulator example . 82
Figure H.3 – Example of a SPICE-compatible ICIM-CI macro-model of the voltage
regulator . 82
IEC CDV 62433-4 ED2 © IEC 2026

Figure H.4 – Example of a board level simulation on the voltage regulator’s ICIM-CI
with PCB model and other components including parasitic elements . 83
Figure H.5 – Incident power as a function of frequency that is required to create a
malfunction with a 10 nF filter . 84
Figure I.1 – Example of an IB file for a given susceptibility criterion with a non-pass/fail
test 85
Figure I.2 – Comparison of simulated transmitted power (P ) and measured immunity
T
behaviour . 86

Table 1 – Attributes of the Lead keyword in the Lead_definitions section . 19
Table 2 – Compatibility between the Mode and Type fields in CIML . 19
Table 3 – Definition of the Validity section of the CIML . 21
Table 4 – Definition of the Lead keyword in the Pdn section . 23
Table 5 – Valid data formats and their default units in the Pdn section . 26
Table 6 – Valid file extensions in the Pdn section . 26
Table 7 – Valid fields of the Lead keyword for single-ended PDN . 28
Table 8 – Netlist definition . 32
Table 9 – Valid fields of the Lead keyword for differential PDN . 35
Table 10 – Differences between the Pdn and Ibc section fields of the Lead keyword . 38
Table 11 – Valid fields of the Lead keyword for IBC definition . 39
Table 12 – Definition of the Lead keyword in Ib section . 40
Table 13 – Max_power_level definition . 41
Table 14 – Voltage, Current and Power definition . 41
Table 15 – IB data selection criteria with one or more Voltage / Current / Power
sections . 42
Table 16 – Test_criteria definition . 43
Table 17 – Default values of Unit_voltage, Unit_current and Unit_power tags as a
function of data format . 44
Table 18 – Valid file extensions in the Ib section . 45
Table 19 – Example of an IB table obtained using a pass/fail test . 53
Table B.1 – Single-ended parameter conversion . 60
Table B.2 – Differential parameter conversion. 61
Table B.3 – Power calculation . 64

IEC CDV 62433-4 ED2 © IEC 2026

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
EMC IC modelling -
Part 4: Models of integrated circuits for RF immunity behavioural
simulation - Conducted immunity modelling (ICIM-CI)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for
standardization comprising all national electrotechnical committees (IEC National Committees).
The object of IEC is to promote international co-operation on all questions concerning
standardization in the electrical and electronic fields. To this end and in addition to other
activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National
Committee interested in the subject dealt with may participate in this preparatory work.
International, governmental and non-governmental organizations liaising with the IEC also
participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as
possible, an international consensus of opinion on the relevant subjects since each technical
committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted
by IEC National Committees in that sense. While all reasonable efforts are made to ensure that
the technical content of IEC Publications is accurate, IEC cannot be held responsible for the
way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC
Publications transparently to the maximum extent possible in their national and regional
publications. Any divergence between any IEC Publication and the corres ponding national or
regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies
provide conformity assessment services and, in some areas, access to IEC marks of conformity.
IEC is not responsible for any services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including
individual experts and members of its technical committees and IEC National Committees for
any personal injury, property damage or other damage of any nature whatsoever, whether direct
or indirect, or for costs (including legal fees) and expenses arising out of the publication, use
of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced
publications is indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve
the use of (a) patent(s). IEC takes no position concerning the evidence, validity or applicability
of any claimed patent rights in respect thereof. As of the date of publication of this document,
IEC [had/had not] received notice of (a) patent(s), which may be required to implement this
IEC CDV 62433-4 ED2 © IEC 2026

document. However, implementers are cautioned that this may not represent the latest
information, which may be obtained from the patent database available at https://patents.iec.ch.
IEC shall not be held responsible for identifying any or all such patent r ights.
IEC 62433-4 has been prepared by subcommittee 47A: Integrated circuits, of IEC technical
committee 47: Semiconductor devices. It is an International Standard.
This second edition cancels and replaces the first edition published in 2016. This edition
constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) removal of annexes on preliminary definitions for XML representation and XML encoding
rules;
b) simplification of XML parts in the main body;
c) addition of informative Annex D and Annex F with examples.
The text of this International Standard is based on the following documents:
Draft Report on voting
47A/XX/FDIS 47A/XX/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English [change
language if necessary].
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
IEC CDV 62433-4 ED2 © IEC 2026

INTRODUCTION
IEC CDV 62433-4 ED2 © IEC 2026

1 Scope
This part of IEC 62433 specifies a flow for deriving a macro-model to allow the simulation of
the conducted immunity levels of an integrated circuit (IC). This model is commonly called
integrated circuit immunity model - conducted immunity, ICIM-CI. It is intended to be used for
predicting the levels of immunity to conducted radio frequency (RF) disturbances applied on IC
pins.
In order to evaluate the immunity threshold of an electronic device, this macro -model will be
inserted into an electrical circuit simulation tool.
This macro-model can be used to model both analogue and digital ICs (input/output, digital core
and supply). This macro-model does not take into account the non-linear effects of the IC.
The added value of ICIM-CI is that it could also be used for immunity prediction at board and
system level through simulations.
This part of IEC 62433 has two main subparts:
– the electrical description of ICIM-CI macro-model elements;
– the representation of ICIM-CI macro-model elements in XML-based CIML schema,
according to encoding scheme defined in IEC 62433-1, to enable a more generic,
interoperable and simulation-orientated format for immunity analysis.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-131, International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
IEC 60050-161, International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic
compatibility
IEC 62132-1, Integrated circuits - Measurement of electromagnetic immunity - Part 1: General
conditions and definitions
IEC 62132-4, Integrated circuits - Measurement of electromagnetic immunity 150 kHz to 1 GHz
- Part 4: Direct RF power injection method
IEC 62433-1, EMC IC modelling - Part 1: General modelling framework
IEC 62433-2, EMC IC modelling - Part 2: Models of integrated circuits for EMI behavioural
simulation - Conducted emissions modelling (ICEM-CE)
CISPR 17, Methods of measurement of the suppression characteristics of passive EMC filtering
devices
3 Terms, definitions, abbreviated terms and conventions
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-131, IEC
60050-161 and IEC 62433-1, and the following, apply.
IEC CDV 62433-4 ED2 © IEC 2026

3.1.1
section
XML element placed one level below the root element or within another section and that
contains one or more XML elements, but no value
3.1.2
parent
keyword which is one level above another keyword
3.1.3
child
keyword which is one level below another keyword
3.1.4
external terminal
terminal of an integrated circuit macro-model which interfaces the model to the external
environment of the integrated circuit
Note 1 to entry: Power supply pins and input/output pins.
Note 2 to entry: In this part of IEC 62433, a terminal is considered external by default unless otherwise stated.
3.1.5
internal terminal
terminal of an integrated circuit macro-model's component which interfaces the component to
other components of the integrated circuit macro-model
3.1.6
parser
tool for syntactic analysis of data that is encoded in a specified format
3.1.7
CIML
conducted immunity markup language
data exchange format for conducted immunity macro-model
3.1.8
CIMLBase
conducted immunity markup language base
abstract type from which all CIML (3.1.7) model components are directly or indirectly derived in
the conducted immunity macro-model definition
3.1.9
DI
disturbance input
input terminal for the injection of RF disturbances
Note 1 to entry: It could be any pin of IC, an input, supply or an output.
3.1.10
DO
disturbance output
terminal whose load influences the impedance of DI (3.1.9) terminal, and/or the transfer
characteristics of PDN (3.1.13), and that outputs a part of the disturbance received on the DI
(3.1.9) terminals
3.1.11
OO
observable output
output terminal where the immunity criteria are monitored during the test
IEC CDV 62433-4 ED2 © IEC 2026

3.1.12
GND
ground terminal
terminal that is used as reference for return path
3.1.13
PDN
passive distribution network
component of an IC model that represents the characteristics of propagation path of
electromagnetic noises such as power distribution network
3.1.14
IB
immunity behaviour
block that describes the internal immunity characteristics of the IC
3.1.15
IBC
inter-block coupling
network of passive elements that presents a coupling effect between circuit blocks within an IC
3.1.16
VNA
vector network analyzer
instrument to measure complex network parameters such as S-, Y- or Z- parameters in the
frequency domain
3.1.17
RFIP
radio frequency injection probe
probe for injecting RF disturbances into a pin of an IC, allowing the measurement of voltage
and the determination of IC pin impedance and current
3.2 Abbreviated terms
CIM Conducted immunity model
ESD Electrostatic discharge
SPICE Simulation program with integrated circuit emphasis
XML Extensible markup language
DUT Device under test
DPI Direct RF power injection
3.3 Conventions
For the sake of clarity, but with some exceptions, the writing conventions of XML have been
used in text and tables.
4 Philosophy
Integrated circuits contain more and more gates, the integration density of technologies is
increasing and supply voltages are becoming lower. The reduction of distance between on -chip
signals, die geometry size reduction and the increase of unwanted currents in parasitic
structures, such as isolation capacitances, often leads to increased internal crosstalk.
Consequently, the immunity of integrated circuits is becoming more and more critical.
Due to this increased risk of lower IC immunity, the use of models and simulation tools is
required to optimize the immunity characteristics of both the IC and the application.
IEC CDV 62433-4 ED2 © IEC 2026

This part of IEC 62433 describes such macro-models for simulating immunity characteristics at
the IC level. The model, called ICIM-CI, will be used to predict electromagnetic immunity at the
application level. This model is based on files describing the PDN and the IB containing data
on electromagnetic disturbances leading to a variation of one or more observable signals. The
PDN is considered to be linear, whereas the inherent non-linearity of the IC is taken into account
in the IB. The validity and justification for this assumption are illustrated in 8.2 (see Figure 22).
Users of the model should apply a failure criterion to the observable signal depending on their
requirements.
ICIM-CI model data is arranged in a decipherable nested manner using XML format. The
objective of this exchange format, called CIML, is to enable simple and practical universal
access to the ICIM-CI model. The preliminary definitions for XML representation are given in
IEC 62433-1.
5 ICIM-CI model description
5.1 General
The internal structure of an IC can be broken down into two parts:
a) passive parts (parasitic elements of pins, bondwires and tracks, ESD protection), which
conduct the disturbances from the external environment to the internal IC blocks,
b) active parts (CPU core, clock system, memory, analogue blocks); these internal blocks are
sensitive to the incoming disturbances.
The ICIM-CI model consists of a set of data describing these two sub-models:
– PDN: the passive distribution network is a multi-port circuit. It is composed of four different
terminals:
• DI: terminals to which disturbances are applied;
• DO: terminals that can influence the impedance of the DI terminals and consequently
receive a part of the disturbance applied on the DI terminals;
• GND: one or more ground terminals (such as digital ground, analogue ground);
• internal terminals: terminals that can influence the impedance of the DI terminals and
are internal to the IC (at chip-level).
– IB: the immunity behaviour component that describes the response of the IC to the applied
disturbances (referenced to one ground terminal of the PDN). The immunity criterion is set
on OO terminals. Depending on the configuration of the IC, the OO terminals can be either
associated to the various DI and/or DO terminals or remain unassociated.
NOTE 1 DI, DO, OO and GND terminals are external terminals and are interfaced at pin level. These pins connect
to the external environment of the IC.
NOTE 2 OO terminals connect the PDN to the IB. Although these terminals are external on the IC and are used to
obtain the IB by monitoring the immunity criterion, they are represented internally as virtual nodes within the PDN of
the ICIM-CI macro-model.
Figure 1 represents an example of the ICIM-CI model structure.
IEC CDV 62433-4 ED2 © IEC 2026

Key
T1, T2 DI terminals (external)
T3, T4, T5, T6 DO terminals (external)
T7, T8 OO terminals (external on the IC, represented internally as virtual nodes within the PDN)
GND1, GND2, GND3 GND terminals (external)
Figure 1 – Example of the ICIM-CI model structure
There is no direct electrical connection between the PDN block and the IB block. The PDN
represents the input impedance of the DI. The power entering the DI is calculated by simulation
based on the PDN and the external environment. The IB links the power entering the DI to an
immunity criterion monitored at the OO. The IB is obtained by an immunity measurement of the
IC, by means of monitoring the OO terminal.
Depending on the IC’s operating conditions and stability, DO terminals can be present. One
such example is illustrated in Annex A.
Different ICIM-CI models can be combined to model and describe a full electronic system such
as an electronic board. That proposed structure can also be used to model individual items of
equipment . The DO terminal of one ICIM-CI model can be used to interface with the different
terminals of neighbouring ICIM-CI blocks.
Figure 2 gives an example of a complete ICIM-CI model of an electronic board. The board is
described by three stand-alone ICIM-CI models: ICIM-CI_1, ICIM-CI_2 and ICIM-CI_3. The DI
terminals, T12 and T21, are connected together, and they receive the same disturbance. The
ICIM-CI_1 propagates a fraction of its disturbance to the ICIM-CI_3 model through its T14 (DO)
terminal, which is connected to the T31 (DI) terminal of the ICIM-CI_3 model.
IEC CDV 62433-4 ED2 © IEC 2026

Key
T11, T12, T21, T31 DI terminals (external)
T13, T14, T32 DO terminals (external)
T16, T17, T18, T26, T27, T36, GND terminals (external)
T37, T38
T15, T22, T33 OO terminals (external on the ICs, represented internally as virtual nodes
within the PDN)
C1, C2 capacitors to couple the disturbance on to the IC pins / terminals
C3 load capacitor
R load resistor
Figure 2 – Example of an ICIM-CI model of an electronic board
The valid frequency range of the ICIM-CI model is the same as that of the data (simulation or
measurement) used for obtaining the PDN and IB parts.
5.2 PDN description
The PDN consists of passive elements for the package, bondwires and on-chip
interconnections. It represents the input network of the power and signal pins of the chip. The
PDN is a complete impedance network, containing the input injection terminals (DI), the
disturbed terminals (DO), the internal terminals and the ground terminals (GND). The DI
terminals may influence the impedance of the DO terminals. The PDN can contain linear and
non-linear components such as resistors, capacitors and ESD protection structures. The PDN
data is defined for conditions under which the non-linear components are not activated.
The PDN characterizes the coupling path for the RF disturbances, which can undergo filtering
and distortion. Its impedance can vary considerably with frequency.
IEC CDV 62433-4 ED2 © IEC 2026

The PDN is defined in the frequency domain and can be characterized by different network
parameters such as:
a) Z(f): impedance, which is the ratio of voltage and current at the disturbance input of the
PDN. It represents the electrical schematic of passive input impedance, often consisting of
parasitic elements and expressed using resistor (R), inductor (L) and capacitor (C)
elements,
b) Y(f): admittance, which is the inverse of Z(f),
c) S(f): S-parameter, which is the ratio of the reverse and forward voltage waves at the
disturbance input of the PDN. This parameter is typically used to measure the characteristics
of RF signal ports.
The conversion between the three types of parameters is described in Annex B. The frequency
validity range of the PDN is defined by the measurement conditions.
The PDN can also be described as a circuit using a SPICE-like netlist [1].
An IC can have many identically designed pins with the same (similar) characteristics. To
reduce the number of DI to be modelled, the pins of an IC can be classified into families, for
simplification purposes, such as:
d) supply pins,
e) digital input/output pins,
f) analogue input/output pins,
g) data/address buses,
h) communication buses.
For complex ICs, it is essential to model the PDN as different blocks for better representation
and easy understanding. These blocks can be internally coupled within the IC. For example, an
IC can contain a digital and an analogue block with different ground terminals (which can be
connected internally), and other terminals that are coupled within the IC. Such coupling
phenomena can be modelled using an IBC network. A detailed description of an IBC network is
presented in 5.3.
The PDN describes the linear behaviour of the device. The non-linear effects are not considered
in the PDN of the ICIM-CI macro-model. Therefore, impedance measurements should be carried
out in the typical operating conditions and in a steady-state mode. The proposed PDN of the
ICIM-CI model is limited such that no defining parameter (voltage, current, or power) exceeds
the activation thresh
...