Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - site validation methods for other sites covered in CISPR 16-1-6 are added; - smaller step sizes are specified for swept frequency measurements; - the minimum ground plane size is increased; - and other miscellaneous technical and editorial refinements are included.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-5: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messplätze für die Antennenkalibrierung und Referenz-Messplätze für den Frequenzbereich von 5 MHz bis 18 GHz

Spécification des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Emplacements d'étalonnage d'antenne et emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 1-5. del: Merilne naprave za merjenje radijskih motenj in odpornosti - Preskuševališča za kalibriranje anten in referenčna preskuševališča za 5 Mhz do 18 Mhz

Ta del standarda CISPR 16 določa zahteve za območja za umerjanje v frekvenčnem območju od 5 MHz do 18 GHz za umerjanje antene v skladu s standardom CISPR 16-1-6. Določa tudi zahteve za referenčna preskusna mesta (REFTS), ki se uporabljajo za preverjanje skladnosti preskusnih mest (COMTS) v frekvenčnem območju od 30 MHz do 1000 MHz v skladu s standardom CISPR 16-1-4.
Ima status osnovnega standarda o elektromagnetni združljivosti (EMC) v skladu z vodilom IEC Guide 107 Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications (Elektromagnetna združljivost – Vodilo za pripravo osnutkov publikacij o elektromagnetni združljivosti). Specifikacije za merilne instrumente so podane v standardih CISPR 16-1-1 [1]1 in CISPR 16-1- 4. Dodatne informacije o splošnih negotovostih so podane v standardu CISPR 16-4 [3], kar je lahko koristno pri ugotavljanju ocen negotovosti pri postopkih umerjanja anten in meritvah preverjanja mest.

General Information

Status
Published
Publication Date
05-Feb-2015
Withdrawal Date
20-Jan-2018
Current Stage
6060 - Document made available - Publishing
Start Date
06-Feb-2015
Completion Date
06-Feb-2015

Relations

Overview

EN 55016-1-5:2015 (CISPR 16-1-5:2014) is the European/CISPR specification for antenna calibration sites and reference test sites covering 5 MHz to 18 GHz. It defines technical requirements and validation procedures for calibration test sites (CALTS) and reference test sites (REFTS) used to support antenna calibration (per CISPR 16-1-6) and validation of compliance test sites (per CISPR 16-1-4). EN 55016-1-5:2015 is a basic EMC standard (IEC Guide 107) and supersedes the earlier edition (2004) and its amendment.

Key topics and technical requirements

  • Scope and frequency range: Requirements apply to calibration sites from 5 MHz to 18 GHz and to REFTS used for validation of compliance sites in 30 MHz–1 000 MHz.
  • Site specifications: Normative specifications for CALTS (metal ground plane sites, SACs, FARs) including updated minimum ground-plane size and ancillary equipment considerations.
  • Validation procedures: Detailed validation methods, including swept-frequency measurements, SIL measurements, antenna-height scans and power-transfer methods for FARs (1 GHz–18 GHz).
  • Antenna and test-antenna requirements: Characteristics and acceptance criteria for test antennas used in site validation and calibration.
  • Uncertainty and measurement instrumentation: Guidance on measurement uncertainty and links to instrumentation specs in CISPR 16-1-1 and CISPR 16-1-4; CISPR 16-4 is referenced for background on uncertainty estimates.
  • Technical updates in edition 2: Adds site validation methods for additional site types, specifies smaller frequency step sizes for swept measurements, increases minimum ground-plane size, and includes editorial refinements.

Practical applications

  • Establishing and validating antenna calibration sites used by calibration laboratories and EMC test houses.
  • Verifying reference test sites (REFTS) that are used to validate radiated disturbance test sites for product EMC compliance.
  • Performing acceptance testing and periodic re-validation of FARs, semi-anechoic chambers (SACs), and ground-plane calibration sites.
  • Supporting uncertainty budgets and traceable antenna-factor determinations for EMC measurements across 5 MHz–18 GHz.

Who should use this standard

  • EMC laboratories and antenna calibration labs
  • Test-house managers and site validators
  • Metrology and accreditation bodies
  • RF/EMC engineers in industries (telecom, automotive, aerospace, consumer electronics)
  • Manufacturers requiring validated measurement sites for compliance testing

Related standards

  • CISPR 16-1-1 / EN 55016-1-1 (measurement instrumentation)
  • CISPR 16-1-4 / EN 55016-1-4 (antennas and test sites for radiated disturbance)
  • CISPR 16-1-6 / EN 55016-1-6 (EMC antenna calibration)
  • CISPR 16-4 (guidance on measurement uncertainty)

Keywords: EN 55016-1-5:2015, antenna calibration sites, reference test sites, site validation, EMC, CISPR 16-1-5, 5 MHz to 18 GHz, FAR, SAC, antenna calibration, measurement uncertainty.

Standard
EN 55016-1-5:2015 - BARVE
English language
96 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2015
1DGRPHãþD
SIST EN 55016-1-5:2005
SIST EN 55016-1-5:2005/A1:2013
6SHFLILNDFLMD]DPHULOQHQDSUDYHLQPHWRGH]DPHUMHQMHUDGLMVNLKPRWHQMLQ
RGSRUQRVWLGHO0HULOQHQDSUDYH]DPHUMHQMHUDGLMVNLKPRWHQMLQRGSRUQRVWL
3UHVNXãHYDOLãþD]DNDOLEULUDQMHDQWHQLQUHIHUHQþQDSUHVNXãHYDOLãþD]D0K]GR
0K]
Specification for radio disturbance and immunity measuring apparatus and methods -
Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration
sites and reference test sites for 5 MHz to 18 GHz
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
1-5: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung
(Funkstörungen) und Störfestigkeit - Messplätze für die Antennenkalibrierung und
Referenz-Messplätze für den Frequenzbereich von 5 MHz bis 18 GHz
Ta slovenski standard je istoveten z: EN 55016-1-5:2015
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 55016-1-5

NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2015
ICS 33.100.10; 33.100.20 Supersedes EN 55016-1-5:2004
English Version
Specification for radio disturbance and immunity measuring
apparatus and methods -
Part 1-5: Radio disturbance and immunity measuring apparatus -
Antenna calibration sites and reference
test sites for 5 MHz to 18 GHz
(CISPR 16-1-5:2014)
Spécification des méthodes et des appareils de mesure des Anforderungen an Geräte und Einrichtungen sowie
perturbations radioélectriques et de l'immunité aux Festlegung der Verfahren zur Messung der hochfrequenten
perturbations radioélectriques - Störaussendung (Funkstörungen) und Störfestigkeit -
Partie 1-5: Appareils de mesure des perturbations Teil 1-5: Geräte und Einrichtungen zur Messung der
radioélectriques et de l'immunité aux perturbations hochfrequenten Störaussendung (Funkstörungen) und
radioélectriques - Emplacements d'étalonnage d'antenne et Störfestigkeit - Messplätze für die Antennenkalibrierung und
emplacements d'essai de référence pour la plage comprise Referenz-Messplätze für den Frequenzbereich
entre 5 MHz et 18 GHz von 5 MHz bis 18 GHz
(CISPR 16-1-5:2014) (CISPR 16-1-5:2014)
This European Standard was approved by CENELEC on 2015-01-21. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 55016-1-5:2015 E
Foreword
The text of document CISPR/A/1086A/FDIS, future edition 2 of CISPR 16-1-5, prepared by
CISPR SC A “Radio-interference measurements and statistical methods" was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as EN 55016-1-5:2015.

The following dates are fixed:
(dop) 2015-10-21
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2018-01-21
standards conflicting with the
document have to be withdrawn
This document supersedes EN 55016-1-5:2004.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard CISPR 16-1-5:2014 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

CISPR 16-1-1:2010 NOTE Harmonized as EN 55016-1-1:2010 (not modified).
CISPR 16-1-1:2010/A1:2010 NOTE Harmonized as EN 55016-1-1:2010/A1:2010 (not modified).
CISPR 16-2-3:2010 NOTE Harmonized as EN 55016-2-3:2010 (not modified).
CISPR 16-2-3:2010/A1:2010 NOTE Harmonized as EN 55016-2-3:2010/A1:2010 (not modified).
CISPR 16-4 Series NOTE Only Part 4-2 harmonized as EN 55016-4-2.

- 3 - EN 55016-1-5:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year

CISPR 16-1-4 2010 Specification for radio disturbance EN 55016-1-4 2010
and immunity measuring apparatus
+A1 2012 +A1 2012
and methods -
Part 1-4: Radio disturbance and immunity
measuring apparatus - Antennas and test
sites for radiated disturbance
measurements
CISPR 16-1-6 2014 Specification for radio disturbance EN 55016-1-6 2015
and immunity measuring apparatus
and methods -
Part 1-6: Radio disturbance
and immunity measuring apparatus -
EMC-antenna calibration
IEC 60050 Series International Electrotechnical Vocabulary - -

CISPR 16-1-5 ®
Edition 2.0 2014-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES

BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM

Specification for radio disturbance and immunity measuring apparatus and methods –

Part 1-5: Radio disturbance and immunity measuring apparatus – Antenna calibration

sites and reference test sites for 5 MHz to 18 GHz

Spécification des méthodes et des appareils de mesure des perturbations

radioélectriques et de l'immunité aux perturbations radioélectriques –

Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux

perturbations radioélectriques – Emplacements d'étalonnage d'antenne et

emplacements d'essai de référence pour la plage comprise entre 5 MHz et 18 GHz

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XD
ICS 33.100.10; 33.100.20 ISBN 978-2-8322-1932-4

– 2 – CISPR 16-1-5:2014  IEC 2014
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 10
2 Normative references . 10
3 Terms, definitions and abbreviations . 10
3.1 Terms and definitions . 10
3.1.1 Antenna terms . 11
3.1.2 Measurement site terms . 13
3.1.3 Other terms . 14
3.2 Abbreviations . 15
4 Specifications and validation procedures for CALTS and REFTS from 5 MHz to
1 000 MHz . 16
4.1 General . 16
4.2 Antenna calibration test site (CALTS) specification . 16
4.2.1 General . 16
4.2.2 Normative specification . 17
4.3 Test antenna specification . 17
4.3.1 General . 17
4.3.2 Details of the required characteristics of the test antenna . 18
4.4 Antenna calibration test site validation procedure . 20
4.4.1 General . 20
4.4.2 Test set-up . 20
4.4.3 Test frequencies and receive antenna heights . 22
4.4.4 SIL measurements . 22
4.4.5 Swept frequency SIL measurements . 25
4.4.6 Identifying and reducing reflections from antenna supports . 28
4.5 Antenna calibration test site acceptance criteria . 28
4.5.1 General . 28
4.5.2 Measurement uncertainties . 28
4.5.3 Acceptance criteria . 29
4.6 Calibration site with a metal ground plane for biconical antennas and tuned
dipole antennas over the frequency range 30 MHz to 300 MHz . 30
4.7 Validation of a REFTS . 31
4.7.1 General . 31
4.7.2 Validation for horizontal polarization . 31
4.7.3 Validation for vertical polarization . 31
4.8 Validation report for CALTS and REFTS . 33
4.8.1 General . 33
4.8.2 Validation report requirements . 33
4.9 Site validation for the calibration of biconical and dipole antennas, and the
biconical part of hybrid antennas in vertical polarization . 34
4.10 Validation of a CALTS using vertical polarization from 5 MHz to 30 MHz for
the calibration of monopole antennas . 35
4.10.1 General . 35
4.10.2 Uncertainty evaluation . 36
5 Validation methods for a FAR from 30 MHz to 18 GHz . 36
5.1 General . 36

CISPR 16-1-5:2014  IEC 2014 – 3 –
5.2 Validation procedure 1 GHz to 18 GHz . 37
5.2.1 Power transfer between two antennas . 37
5.2.2 Measurement procedure for validation from 1 GHz to 18 GHz . 37
5.2.3 Analysis of results . 39
5.2.4 Acceptance criterion . 40
5.2.5 Chamber performance versus polarization . 41
5.2.6 Uncertainty . 41
5.3 Validation of a FAR for the calibration of antennas by alternative methods. 42
5.3.1 General . 42
5.3.2 Validation of a FAR from 30 MHz to 1 GHz . 42
5.3.3 Alternative validation of a FAR for the calibration of LPDA antennas
above 1 GHz. 42
5.3.4 Alternative validation of a FAR applying time-domain measurements
above 500 MHz. 43
6 Validation methods for sites used for the calibration of directive antennas . 43
6.1 Validation of the calibration site minimizing ground reflection by a height
≥ 4 m . 43
6.1.1 Measurement procedure . 43
6.1.2 Uncertainties . 45
6.2 Validation of the calibration site minimizing ground reflection by use of
absorber . 46
7 Site validation by comparison of antenna factors, and application of RSM to
evaluate the uncertainty contribution of a SAC site . 47
7.1 Use of SAM for site validation by comparison of antenna factors . 47
7.2 Application of RSM to evaluate the measurement uncertainty contribution of
a calibration site comprising a SAC . 48
Annex A (informative) CALTS characteristics and validation . 50
A.1 General . 50
A.2 The reflecting plane . 50
A.2.1 Reflecting plane construction . 50
A.2.2 Plane-edge effects and plane surroundings . 51
A.3 Ancillary equipment . 51
A.4 Additional stringent CALTS validation testing . 52
A.4.1 General . 52
A.4.2 Antenna-height scan measurements . 52
A.4.3 Frequency scan measurements . 53
Annex B (informative)  Test antenna considerations. 56
B.1 General . 56
B.2 Example and verification of a test antenna . 56
B.3 Determination of balun properties . 58
B.3.1 The ideal lossless balun . 58
B.3.2 Relations between balun properties and S-parameters . 59
B.3.3 Insertion loss measurements . 60
Annex C (informative)  Antenna and SIL theory . 63
C.1 Analytical relations . 63
C.1.1 General . 63
C.1.2 Total length of the test antenna . 64
C.1.3 Theoretical SIL . 65
C.1.4 Calculation example . 69

– 4 – CISPR 16-1-5:2014  IEC 2014
C.2 Computations by the MoM. 72
C.2.1 General . 72
C.2.2 Antenna input impedance . 73
C.2.3 Total length of the test antenna . 73
C.2.4 SIL computations . 73
C.2.5 Antenna factor (AF) computations . 80
Annex D (informative) Pascal Program used in C.1.4 . 84
Annex E (informative) Validation procedure checklist . 88
Annex F (informative) Evidence that field taper of VP site validation method has
negligible effect on measured antenna factor . 90
F.1 Investigation of vertical field taper . 90
F.2 Calibration of biconical antennas using vertical polarization . 90
Bibliography . 92

Figure 1 – Schematic diagram of the test antenna . 18
Figure 2 – Adjustment of a telescopic wire element to the length L . 19
we
Figure 3 – Determination of V (f) or V (f) . 23
r1 r2
Figure 4 – Determination of V (f) with the wire antennas in their specified positions . 23
s
Figure 5 – Example NSIL: horizontal polarization, antenna height 2 m, separation
10 m . 26
Figure 6 – NSIL of the four pairs of calculable dipoles at 10 m separation and using

the alternative heights for the 600 MHz to 1 000 MHz pair according to Table 5 . 27
Figure 7 – Relation between the quantities used in the SIL acceptance criterion . 29
Figure 8 – Set-up of site validation for EMC antenna calibrations above 1 GHz in a
FAR, also showing distance between antenna phase centres . 38
Figure 9 – Example plots of [A (d) − A (d )] in dB against distance in m at 1 GHz
i m i m 3 m
to 18 GHz in 1 GHz steps, corrected for LPDA and horn phase centres . 40
Figure 10 – Example of antenna set-up for an LPDA antenna calibration in the
frequency range above 200 MHz . 44
Figure 11 – Example of SIL versus antenna height measured at 200 MHz with two
LPDA antennas in vertical polarization at 2,5 m distance between their midpoints
above the reflecting ground plane of an OATS . 45
Figure 12 – Illustration of distances of transmit horn to omni-directional receive
antenna and reflective building, and transmitted signal paths A and B . 45
Figure B.1 – Example of a test antenna . 58
Figure B.2 – Diagram of the measurement of S and S , and of S and S , when
11 12 22 21
generator and load are interchanged . 59
Figure B.3 – Schematic diagram for determination of the insertion loss A (f) . 61
Figure B.4 – Schematic diagram for determination of the insertion loss A (f) . 61
Figure C.1 – Network model for A calculations . 66
i c
Figure C.2 – Equivalent circuit to the network in Figure C.1 . 66
Figure C.3 – Definition of the mutual couplings, feed-terminal voltages and antenna
currents of the antennas above the reflecting plane and their images . 67
Figure C.4 – Cascade combination of the baluns and the site two-port network . 74
Figure C.5 – Flow chart showing how SIL is obtained by combining the measured balun
S-parameters and the NEC calculated S-parameters of the site two-port network . 75
Figure F.1 – Field uniformity with height step 1 m to 2,6 m, normalized to field at 1,8 m
height; monocone at 15 m range . 90

CISPR 16-1-5:2014  IEC 2014 – 5 –
Figure F.2 – Averaging of height steps, SAM, B.4.2 in CISPR 16-1-6:2014 . 91

Table 1 – Summary of site validation methods by subclause number . 9
Table 2 – Maximum tolerances for d = 10 m . 18
Table 3 – Frequency and fixed receive antenna height data for SIL measurements at
24 frequencies, with h = 2 m and d = 10 m [specified in 4.4.2.3 and 4.4.2.4] . 22
t
Table 4 – RSM frequency steps . 25
Table 5 (informative) – Antenna heights for SIL measurements . 26
Table 6 – Antenna set-up for the SIL measurement of the calibration site using
horizontally polarized resonant dipole antennas (see also 4.4.4 for SIL at 250 MHz and
300 MHz) . 31
Table 7 – Antenna heights . 32
Table 8 – Example measurement uncertainty budget for SIL between two monopole
antennas . 36
Table 9 – Example measurement uncertainty budget for FAR validation method at and

above 1 GHz . 41
Table 10 – Example measurement uncertainty budget for the site validation method in
6.1.1 . 46
Table 11 – Maximum tolerances for validation set-up at d = 10 m . 49
Table A.1 – Example of fixed-length calculable dipole antennas and their subdivision of
the frequency range 30 MHz to 1 000 MHz . 51
Table A.2 – Receive antenna heights and centre frequencies . 54
Table C.1 – Example numerical (analytical) calculation of L , A (see C.1.4.2) . 69
a i c
Table C.2 – Example numerical (analytical) calculation of ∆A (see C.1.4.3) . 71
t
Table C.3 – Example numerical (analytical) calculation of h and ∆h . 72
rc rt
Table C.4 – Example numerical (analytical) calculation of f and ∆f . 72
c t
Table C.5 – MoM example calculation of A for vertical polarization, h = 2 m, except
i c t
h = 2,75 m at 30 MHz, 35 MHz and 40 MHz . 78
t
– 6 – CISPR 16-1-5:2014  IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
____________
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –

Part 1-5: Radio disturbance and immunity measuring apparatus –
Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard CISPR 16-1-5 has been prepared by CISPR subcommittee A: Radio-
interference measurements and statistical methods.
This second edition cancels and replaces the first edition published in 2003, and its
Amendment 1 (2012). It constitutes a technical revision.
It has the status of a basic EMC publication in accordance with IEC Guide 107,
Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility
publications.
This edition includes the following significant technical changes with respect to the previous
edition:
CISPR 16-1-5:2014  IEC 2014 – 7 –
– site validation methods for other sites covered in CISPR 16-1-6 are added;
– smaller step sizes are specified for swept-frequency measurements;
– the minimum ground plane size is increased;
– other miscellaneous technical and editorial refinements are included.
The text of this standard is based on the following documents:
FDIS Report on voting
CISPR/A/1086A/FDIS CISPR/A/1097/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
A list of all parts of the CISPR 16 series can be found, under the general title Specification for
radio disturbance and immunity measuring apparatus and methods, on the IEC website.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 8 – CISPR 16-1-5:2014  IEC 2014
INTRODUCTION
This standard describes validation procedures for Calibration Test Sites (CALTS) that are
used to calibrate antennas in the frequency range 5 MHz to 18 GHz. The associated antenna
calibration procedures are described in CISPR 16-1-6.
Due to problems with suppressing ground reflections in the frequency range 30 MHz to
200 MHz, the main function of a reflecting ground plane is for the calibration of dipole,
biconical, and hybrid antennas over the frequency range for which their H-plane patterns are
uniform. The free-space antenna factor, F , for dipole antennas may be measured in a free-
a
space environment above 200 MHz. Because of the difficulty of reducing reflections from
objects that surround an antenna, and in particular the ground surface, a flat metal ground
plane is used to ensure reproducibility of results and to enable the ground reflected signal to
be precisely removed mathematically.
Requirements for the construction of a CALTS are given in Annex A. The specifications and
validation procedures for a CALTS are given in Clause 4. The most precise way of validating
a CALTS is to use calculable dipole antennas, which are the basis of the validation procedure
in this standard. The design principles of calculable antennas are given in Annex B, and the
theory and methods for calculating site insertion loss (SIL) are given in Annex C and Annex D.
Validation procedures for other antenna calibration sites are given in Clause 5 through
Clause 7. Where an antenna calibration method utilizes the ground reflection, a CALTS is
required. The validation methods are summarized in Table 1 with reference to the associated
antenna calibration methods in CISPR 16-1-6.
All site validation methods involve the measurement of SIL between two antennas. It is critical
that the validation of the site itself not be unduly compromised by reflections from antenna
supports; see A.3 for associated guidance.

CISPR 16-1-5:2014  IEC 2014 – 9 –
Table 1 – Summary of site validation methods by subclause number
CISPR 16-1-
CISPR 16-1-5
6:2014 Frequency
validation
Calibration Antenna
calibration range
Polarization Notes
method(s)
site(s) type(s)
method(s)
MHz
Subclause
Subclause
With
CALTS for
1 4.10 G.1 5 to 30 Monopole VP tolerance of
monopoles
± 1 dB
CALTS or Biconical,
2 4, 7.2 8.4 30 to 1 000 HP SSM
a
SAC LPDA, hybrid
At large
CALTS or Biconical, height or with
3 4 9.2.2 30 to 300 HP or VP
SAC hybrid, dipole absorber on
ground
Biconical,
30 to 300
hybrid, dipole
4 FAR 5.3.2 9.2.2 HP
Biconical,
60 to 1 000
dipole
5 REFTS 4.7
Biconical,
9.3 30 to 300 VP
hybrid
CALTS 4.9
9.4.2
LPDA, HP with
6 Free space 6.1 200 to 18 000 VP
hybrid, horn greater height
9.4.3
LPDA, With absorber
7 Free space 6.2 9.4.4 200 to 18 000 VP (or HP)
hybrid, horn on ground
8 FAR 5.3.3 9.5 1 000 to 18 000 Horn, LPDA HP or VP
9 FAR 5.3.2 9.2 and 9.4 140 to 1 000 LPDA, hybrid HP or VP
Biconical,
10 CALTS 4.6 B.4, B.5 30 to 300 HP
dipole
Transfer of
properties
Use primarily
of a
for SAM and
validated
FAR, for
7.1
site to a Any, but not
particular
11 site not A.9.4 30 and above monopole or HP or VP
(excluding
antenna types
validated loop
5.3 FAR)
and
by
frequencies,
methods in
except 5.3
other
clauses
a
A CALTS is well specified as being free of reflecting obstacles, and if the antenna supports have negligible
reflections the ground plane itself is likely to provide results that agree with the theoretical performance to better
than 0,5 dB. However for a Semi Anechoic Chamber (SAC), it is important that the entire allowed acceptance
criterion of 1 dB is not taken up by wall reflections, leaving no latitude for other uncertainty components such as
reducing reflections from masts and cables.

– 10 – CISPR 16-1-5:2014  IEC 2014
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –

Part 1-5: Radio disturbance and immunity measuring apparatus –
Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

1 Scope
This part of CISPR 16 specifies the requirements for calibration sites in the frequency range
5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also
specifies the requirements for reference test sites (REFTS) that are used for the validation of
compliance test sites (COMTS) in the frequency range 30 MHz to 1 000 MHz according to
CISPR 16-1-4.
It has the status of a basic EMC standard in accordance with IEC Guide 107, Electromagnetic
compatibility – Guide to the drafting of electromagnetic compatibility publications.
Measurement instrumentation specifications are given in CISPR 16-1-1 [1] and CISPR 16-1-
4. Further information and background on uncertainties in general is given in CISPR 16-4 [3],
which can also be helpful in establishing uncertainty estimates for the calibration processes of
antennas and site validation measurements.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
CISPR 16-1-4:2010, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Antennas
and test sites for radiated disturbance measurements
CISPR 16-1-4:2010/AMD 1:2012
CISPR 16-1-6:2014, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-6: Radio disturbance and immunity measuring apparatus – EMC
antenna calibration
IEC 60050 (all parts), International Electrotechnical Vocabulary (available at
)
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050, as well as
the following apply.
NOTE Full terms for abbreviations not already given in 3.1 are listed in 3.2.
____________
Numbers in square brackets refer to the bibliography.

CISPR 16-1-5:2014  IEC 2014 – 11 –
3.1.1 Antenna terms
3.1.1.1
antenna
transducer that converts the guided electromagnetic energy of the feed line into a radiated
wave in space and vice versa
Note 1 to entry: In the context of this standard, for antennas for which a balun is intrinsic to the functioning of the
antenna, the term “antenna” includes the balun.
3.1.1.2
biconical antenna
symmetric antenna formed by two conical radiating elements having a common axis, and
adjacent vertices at which they are fed
Note 1 to entry: For use in the VHF band, biconical antennas are usually made of two conical-shaped wire cages.
Often each cage has a cross-bar connecting the centre conductor and one of the peripheral wires to remove a
narrowband resonance. Such shorting cross-bars can affect the characteristics of the antenna above 215 MHz. For
more details, see also A.4.3 of CISPR 16-1-6:2014.
3.1.1.3
broadband antenna
antenna having acceptable characteristics over a wide range of radio frequencies
3.1.1.4
calculable antenna
dipole-like antenna of which the antenna factor of a single antenna, and the site insertion loss
between a pair of antennas, may be calculated using either analytical or numerical (method of
moments) techniques based on the dimensions, load impedance and geometrical parameters,
and that can be verified by measurement
Note 1 to entry: An example of a calculable antenna is that specified in Annex B. Another example is a simple
loop antenna.
Note 2 to entry: Effects of the balun are typically accounted for by S-parameters measurements of the balun
network, or the balun structure can be modelled.
3.1.1.5
horn antenna
antenna consisting of a waveguide section in which the cross-sectional area increases
towards an open end, which is known as the aperture
Note 1 to entry: Rectangular-waveguide pyramidal horn antennas are popular in the microwave frequency range
above about 1 GHz. Double-ridged-waveguide horn antennas (DRH; sometimes also referred to as DRG horn, for
double-ridged-guide) cover a very wide frequency range. The mainlobe of some DRH antennas splits into several
beams at higher frequencies.
3.1.1.6
hybrid antenna
antenna consisting of a wire-element log-periodic dipole array section and a broadband dipole
section
Note 1 to entry: The longest element of the LPDA section (see 3.1.1.7) is typically resonant at approximately
200 MHz, and the boom is lengthened at the open-circuit end to feed the connected broadband dipole (e.g.
biconical or bowtie) section. Over the range 30 MHz to 200 MHz, the broadband dipole exhibits a performance
similar to a biconical antenna, notably in the variation of height-dependent antenna factor.
Note 2 to entry: A common-mode choke is typically used at the open-circuit end (i.e. rear) of the boom to
minimize parasitic (unintended) RF currents on the outer conductor of the coaxial cable flowing into the measuring
receiver.
– 12 – CISPR 16-1-5:2014  IEC 2014
3.1.1.7
log-periodic dipole array antenna
LPDA antenna
antenna comprising an array of linear dipole elements whose dimensions and spacings
increase logarithmically with frequency from the tip to the rear end of the antenna
3.1.1.8
resonant dipole antenna
tuned dipole antenna
antenna consisting of two straight collinear conductors of equal length, placed end to end,
separated by a small gap constituting a balanced feed, with each conductor approximately a
quarter-wavelength long such that at the specified frequency the input impedance of the
antenna measured across the gap has zero reactance when the dipole is located in free
space
Note 1 to entry: A resonant dipole antenna is also a calculable antenna (see 3.1.1.4). In this standard the term
“linear dipole” implies “two straight collinear conductors,” in contrast to the biconical dipole, or array of dipoles as
in the LPDA antenna.
3.1.1.9
standard antenna
STA
antenna for which the AF is calculated or measured precisely
Note 1 to entry: Precision is attainable by a calculable antenna such as specified in 4.3. Alternatively an STA may
be an antenna of a type similar to the AUC that has been calibrated to lower uncertainties than required for the
AUC, e.g. by the three antenna method.
Note 2 to entry: An STA is us
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 55016-1-5:2015 is a standard published by CLC. Its full title is "Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz". This standard covers: CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - site validation methods for other sites covered in CISPR 16-1-6 are added; - smaller step sizes are specified for swept frequency measurements; - the minimum ground plane size is increased; - and other miscellaneous technical and editorial refinements are included.

CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - site validation methods for other sites covered in CISPR 16-1-6 are added; - smaller step sizes are specified for swept frequency measurements; - the minimum ground plane size is increased; - and other miscellaneous technical and editorial refinements are included.

EN 55016-1-5:2015 is classified under the following ICS (International Classification for Standards) categories: 33.100.10 - Emission; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 55016-1-5:2015 has the following relationships with other standards: It is inter standard links to EN 55016-1-5:2004/A1:2012, EN 55016-1-5:2004, EN 55016-1-5:2015/A1:2017, EN 55016-1-5:2015/AC:2020-09. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 55016-1-5:2015 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 55016-1-5:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.