Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies

Amdt to align EN 50131-6:2008 with the requirements in EN 50131-3:2009 * D143/C080: New date for delivery of draft to CCMC approved with transfer to the new audit system*2014-02-11: Publication allocated to svandriessche@cencenelec.eu

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen

Systèmes d'alarme - Systèmes d'alarme contre l’intrusion et les hold-up - Partie 6: Alimentation

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6. del: Napajalniki - Dopolnilo A1

Ta evropski standard določa zahteve, merila uspešnosti in preskusne postopke za napajalnike za uporabo kot del alarmnega sistema za javljanje vloma in ropa. Napajalnik je lahko sestavni del komponente I&HAS ali samostojen. Krmilne funkcije napajalnika je mogoče vključiti kot del napajalne naprave ali pa jih lahko zagotavlja drug sestavni del I&HAS, npr. CIE. Ta evropski standard se ne uporablja, kadar so zahteve napajalnika za sestavne dele I&HAS zajete v ustreznem standardu izdelka. Zahteve ustrezajo vsakemu od štirih varnostnih razredov, ki so navedeni v evropskem standardu EN 50131-1 Alarmni sistemi - Sistemi za javljanje vloma in ropa: sistemske zahteve. Zahteve so podane tudi za štiri okoljske razrede, ki zajemajo uporabo v zaprtih prostorih in na prostem. Ta standard zajema obvezne funkcije, ki jih je treba zagotoviti pri vseh napajalnikih in neobveznih funkcijah, ki so morda na voljo. Lahko so na voljo druge funkcije, povezane z I&HAS, ki niso navedene v tem standardu. Take funkcije ne smejo vplivati na zahteve obveznih ali izbirnih funkcij.

General Information

Status
Withdrawn
Publication Date
12-Jun-2014
Withdrawal Date
16-Mar-2017
Technical Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
18-Sep-2020
Completion Date
18-Sep-2020

Relations

Buy Standard

Amendment
EN 50131-6:2008/A1:2014
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 50131-6:2008/A1:2014
01-september-2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 6. del: Napajalniki - Dopolnilo
A1
Alarm systems - Intrusion and hold-up systems -- Part 6: Power supplies
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 6: Energieversorgungen
Systémes d'alarme - Systémes d'alarme contre l’intrusion et les hold-up - Partie 6:
Alimentation
Ta slovenski standard je istoveten z: EN 50131-6:2008/A1:2014
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
SIST EN 50131-6:2008/A1:2014 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 50131-6:2008/A1:2014

---------------------- Page: 2 ----------------------

SIST EN 50131-6:2008/A1:2014

EUROPEAN STANDARD EN 50131-6:2008/A1

NORME EUROPÉENNE

EUROPÄISCHE NORM
June 2014
ICS 13.310
English Version
Alarm systems - Intrusion and hold-up systems - Part 6: Power
supplies
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 6: Alimentation 6: Energieversorgungen
This amendment A1 modifies the European Standard EN 50131-6:2008; it was approved by CENELEC on 2014-03-17. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 50131-6:2008/A1:2014 E

---------------------- Page: 3 ----------------------

SIST EN 50131-6:2008/A1:2014
EN 50131-6:2008/A1:2014 – 2 –
Foreword
This document (EN 50131-6:2008/A1:2014) has been prepared by CLC/TC 79 "Alarm systems".
The following dates are fixed:
• latest date by which this document has
(dop) 2015-03-17
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national
(dow) 2017-03-17
standards conflicting with this
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
__________

---------------------- Page: 4 ----------------------

SIST EN 50131-6:2008/A1:2014
– 3 – EN 50131-6:2008/A1:2014
1 Modification to the Scope
th
Add the following new 5 paragraph:
"This European Standard does not deal with requirements for compliance with EC regulatory
Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the
equipment operating conditions for EMC susceptibility testing as required by EN 50130-4."
2 Modifications to Clause 2, Normative references
rd
Replace the 3 entry with the following:
"EN 50131-1 2006 Alarm systems – Intrusion and hold-up systems – Part 1: System
+ A1 2009 requirements"
Delete the entry for EN 60065.
Add the following new entries:
"EN 60068-2-14 2009 Environmental testing – Part 2-14: Tests – Test N: Change of
temperature (IEC 60068-2-14:2009)
EN 60068-2-75 1997 Environmental testing – Part 2-75: Tests – Test Eh: Hammer tests
(IEC 60068-2-75:1997)"
Delete the entry for EN 60950 series.
Delete the entry for EN 61000-6-3.
3 Modification to Clause 3, Definitions and abbreviations
3.1.11
open by normal means
rd
Delete the 3 word “by” in the definition.
4 Modification to Clause 4, Functional requirements
4.1 General
Replace Figure 1 with the following:
"