Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment

IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353. This International Standard is to be used in conjunction with IEC 61557-1:2019. IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1; b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7; c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1; d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1; e) change of 4.2.3 from test sockets to sockets for service purposes; f) addition of a warning in the operating instructions; g) integration of former 6.3 into 6.2; h) update of Table 1; i) alignment of the structure with that of the whole IEC 61557 series.

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen – Teil 16: Geräte zur Prüfung der Sicherheit elektrischer Geräte und medizinischer elektrischer Geräte nach IEC 62638 und IEC 62353

Sécurité électrique dans les réseaux de distribution basse tension au plus égale à 1 000 V en courant alternatif et 1 500 V en courant continu - Dispositifs de contrôle, de mesure ou de surveillance de mesures de protection - Partie 16: Équipement pour les essais de bon fonctionnement des mesures de protection des appareils électriques et/ou des appareils électromédicaux

L'IEC 61557-16:2023 spécifie les exigences de performance applicables pour les dispositifs de contrôle et de mesure afin de déterminer le bon fonctionnement des mesures de protection des appareils électriques et/ou des appareils électromédicaux décrits dans l’IEC 62353. L'IEC 61557-16:2023 annule et remplace la première édition parue en 2014. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l’édition précédente: a) séparation des exigences d’incertitude pour les appareils électromédicaux et électriques non médicaux en 4.2.1; b) ajout d’une définition de plages avec une incertitude définie de 4.2.1 à 4.2.7; c) ajout d’un dispositif de mesure (DM) facultatif pour les appareils non médicaux en 4.2.1; d) ajout d’une limitation de l’incertitude intrinsèque maximale pour les applications médicales au niveau du courant de fuite en 4.2.1; e) changement en 4.2.3 de "prises de courant d’essai" en "prises de courant pour des besoins de service"; f) ajout d’un avertissement dans les instructions de fonctionnement; g) intégration de l’ancien 6.3 en 6.2; h) mise à jour du Tableau 1; i) alignement de la structure sur celle de l’ensemble de la série IEC 61557.

Električna varnost v nizkonapetostnih razdelilnih sistemih za izmenične napetosti do 1 kV in enosmerne napetosti do 1,5 kV - Oprema za preskušanje, merjenje ali nadzorovanje zaščitnih ukrepov - 16. del: Oprema za preskušanje učinkovitosti zaščitnih ukrepov električne opreme oziroma medicinske električne opreme

General Information

Status
Not Published
Publication Date
01-Oct-2023
Current Stage
5060 - Voting results sent to TC, SR - Formal Approval
Start Date
30-Jun-2023
Completion Date
30-Jun-2023

Relations

Buy Standard

Draft
prEN IEC 61557-16:2022
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 61557-16:2022
01-julij-2022
Električna varnost v nizkonapetostnih razdelilnih sistemih za izmenične napetosti
do 1 000 kV in enosmerne napetosti do 1 500 kV - Oprema za preskušanje,
merjenje ali nadzorovanje zaščitnih ukrepov - 16. del: Oprema za preskušanje
učinkovitosti zaščitnih ukrepov električne opreme oziroma medicinske električne
opreme
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c -
Equipment for testing, measuring or monitoring of protective measures - Part 16:
Equipment for testing the effectiveness of the protective measures of electrical
equipment and/or medical electrical equipment
Sécurité électrique dans les réseaux de distribution basse tension de 1 000 V c.a. et 1
500 V c.c. - Dispositifs de contrôle, de mesure ou de surveillance de mesures de
protection - Partie 16: Équipement pour les essais de bon fonctionnement des mesures
de protection de l'équipement électrique et/ou de l'équipement médical électrique
Ta slovenski standard je istoveten z: prEN IEC 61557-16:2022
ICS:
17.220.20 Merjenje električnih in Measurement of electrical
magnetnih veličin and magnetic quantities
29.080.01 Električna izolacija na Electrical insulation in
splošno general
29.240.01 Omrežja za prenos in Power transmission and
distribucijo električne energije distribution networks in
na splošno general
oSIST prEN IEC 61557-16:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 61557-16:2022
oSIST prEN IEC 61557-16:2022
85/831/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61557-16 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2022-06-03 2022-08-26
SUPERSEDES DOCUMENTS:
85/789/CD, 85/804A/CC
IEC TC 85 : MEASURING EQUIPMENT FOR ELECTRICAL AND ELECTROMAGNETIC QUANTITIES
SECRETARIAT: SECRETARY:
China Ms Guiju HAN
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

SC 62A,TC 66
Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.

TITLE:
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c -
Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment
for testing the effectiveness of the protective measures of electrical equipment and/or medical
electrical equipment
PROPOSED STABILITY DATE: 2028
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 61557-16:2022
IEC CDV 61557-16 © IEC 2022 2 85/831/CDV
1 CONTENTS
2 CONTENTS . 1
3 FOREWORD . 4
4 INTRODUCTION . 6
5 1 Scope . 7
6 2 Normative references . 7
7 3 Terms and definitions . 8
8 4 Requirements . 9
9 4.1 General requirements . 9
10 4.2 Measuring functions . 10
11 4.2.1 Minimum measuring function requirements . 10
12 4.2.2 Measurement of the resistance of the protective bonding or the
13 protective earth resistance . 10
14 4.2.3 Measurement of insulation resistance . 11
15 4.2.4 Measurement of protective conductor current and/or equipment leakage
16 current with the alternative method . 11
17 4.2.5 Measurement of touch current, patient leakage current and applied part
18 leakage current with the alternative method . 12
19 4.2.6 Measurement of protective conductor current and equipment leakage
20 current with the direct or differential (residual) method . 12
21 4.2.7 Measurement of touch current, patient leakage current and applied part
22 leakage current with the direct or differential (residual) method . 13
23 4.3 Construction requirements . 14
24 4.3.1 Overload capability . 14
25 4.3.2 Terminals . 14
26 4.3.3 Sockets for service purpose . 14
27 4.3.4 Degree of protection . 14
28 4.3.5 Class of protection . 14
29 4.3.6 Overvoltage and measurement categories . 14
30 4.3.7 Accessories . 15
31 5 Markings and operating instructions . 15
32 5.1 Markings . 15
33 5.2 Operating instructions . 15
34 6 Tests . 15
35 6.1 General . 15
36 6.2 Operating uncertainty . 16
37 6.3 Tests of measuring circuits according to measuring functions . 18
38 6.4 Test of construction requirements of test and measurement equipment . 19
39 Annex A (normative) Measuring circuit MD . 20
40 A.1 Current measuring circuit MD . 20
41 A.2 Frequency characteristic of current measuring circuit MD . 20
42 Bibliography . 22
44 Figure A.1 – The current measuring circuit MD . 20
45 Figure A.2 – The frequency characteristic of the current measuring circuit MD . 21
47 Table 1 – Calculation of operating uncertainty for leakage measurements with direct or
48 differential method . 17

oSIST prEN IEC 61557-16:2022
IEC CDV 61557-16 © IEC 2022 3 85/831/CDV
49 Table 2 – Compliance tests of measuring circuits according to measuring function . 18
50 Table 3 – Compliance test of construction requirements of test and measuring
51 equipment . 19
oSIST prEN IEC 61557-16:2022
IEC CDV 61557-16 © IEC 2022 4 85/831/CDV
54 INTERNATIONAL ELECTROTECHNICAL COMMISSION
55 ____________
57 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP
58 TO 1 000 V AC AND 1 500 V DC – EQUIPMENT FOR TESTING,
59 MEASURING OR MONITORING OF PROTECTIVE MEASURES –
61 Part 16: Equipment for testing the effectiveness of the protective
62 measures of electrical equipment and/or medical electrical equipment
64 FOREWORD
65 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
66 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
67 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
68 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
69 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
70 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
71 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
72 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
73 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
74 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
75 consensus of opinion on the relevant subjects since each technical committee has representation from all
76 interested IEC National Committees.
77 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
78 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
79 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
80 misinterpretation by any end user.
81 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
82 transparently to the maximum extent possible in their national and regional publications. Any divergence between
83 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
84 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
85 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
86 services carried out by independent certification bodies.
87 6) All users should ensure that they have the latest edition of this publication.
88 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
89 members of its technical committees and IEC National Committees for any personal injury, property damage or
90 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
91 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
92 Publications.
93 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
94 indispensable for the correct application of this publication.
95 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
96 rights. IEC shall not be held responsible for identifying any or all such patent rights.
97 International Standard IEC 61557-16 has been prepared by IEC technical committee 85:
98 Measuring equipment for electrical and electromagnetic quantities.
99 This second edition cancels and replaces the first edition published in 2014. This edition
100 constitutes a technical revision.
101 This edition includes the following significant technical changes with respect to the previous
102 edition:
103 a) splitting of uncertainty requirements for medical and non-medical electrical equipment in
104 4.2.1
105 b) addition of a definition of ranges with defined uncertainty in 4.1.2 up to 4.1.7
106 c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1.
107 d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at
108 leakage current in 4.2.1
oSIST prEN IEC 61557-16:2022
IEC CDV 61557-16 © IEC 2022 5 85/831/CDV
109 e) change of 4.2.3 from test sockets to sockets for service purposes;
110 f) addition of a warning in the operating instructions;
111 g) integration of former 6.3 into 6.2;
112 h) update of Table 1;
113 i) alignment of the structure with that of the whole IEC 61557 series.
115 The text of this standard is based on the following documents:
FDIS Report on voting
117 Full information on the voting for the approval of this standard can be found in the report on
118 voting indicated in the above table.
119 This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
120 This
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.