EN 60534-2-1:1993
(Main)Industrial-process control valves - Part 2: Flow capacity - Section 1: Sizing equations for incompressible fluid flow under installed conditions
- BACK
- 15-Mar-1993
- 30-Nov-1993
- CLC/SR 65B
Industrial-process control valves - Part 2: Flow capacity - Section 1: Sizing equations for incompressible fluid flow under installed conditions
Superseded by EN 60534-2-1:1998
Stellventile für die Prozeßregelung - Teil 2: Durchflußkapazität - Hauptabschnitt 1: Bemessungsgleichungen für inkompressible Fluide unter Einbaubedingungen
Vannes de régulation des processus industriels - Partie 2: Capacité d'écoulement - Section 1: Equations de dimensionnement des vannes de régulation pour l'écoulement des fluides incompressibles dans les conditions d'installation
Industrial-process control valves - Part 2: Flow capacity - Section 1: Sizing equations for incompressible fluid flow under installed conditions (IEC 60534-2:1978)
General Information
Relations
This May Also Interest You
IEC 62974-1:2024 specifies product and performance requirements for devices that fall under the heading of "monitoring and measuring systems used for data collection, aggregation and analysis", for industrial, commercial, and similar use rated below or equal to 1 kV AC and 1,5 kV DC. These devices are fixed and are intended to be used indoors as panel-mounted devices, or as modular devices fixed on a DIN rail, or as housing devices fixed on a DIN rail, or as devices fixed by other means inside a cabinet. These devices are used to upload or download information (energy measured on loads, power metering and monitoring data, temperature information, etc.), mainly for energy efficiency purposes. These devices are known as energy servers (ESE), energy data loggers (EDL), data gateways (DGW) and I/O data concentrators (IODC) and are grouped together under the family name of Data Management Devices (DMD). This document does not cover: • devices used only in the consumer market (living quarters) or household; • devices used in the smart metering infrastructure (e.g. smart meters); • devices used in the smart grid infrastructure; • devices used as IT servers in the information technology business; • power metering and monitoring devices (PMD); • I/O data concentrators already covered by a specific product standard; • communication protocols and interoperability; • power quality instruments (PQI); • software used for the data collection and analysis of the power quality for the supply side. IEC 62974-1:2024 cancels and replaces the first edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the performance criteria have been reviewed; b) EMC and safety requirements have been improved; c) mechanical requirements have been clarified and amended.
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft6 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.120.50
- 2014/35/EU
- M/511
- CLC/SR 32B
These supplementary requirements apply to fuse-links for the protection of batteries and battery systems, including, but not limited to terminology, for electricity storage in equipment for circuits of nominal voltages up to 1 500 V d.c. Their rated voltage may be higher than 1 500 V d.c. The object of these supplementary requirements is to establish the characteristics of Battery fuse-links in such a way that they can be replaced by other fuse-links having the same characteristics, provided that their dimensions are identical.
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.120.50
- 2014/35/EU
- M/511
- CLC/SR 32B
IEC 60688:2024 applies to transducers (TRD) with electrical inputs and outputs for making measurements of AC or DC electrical quantities. The output signal can be in the form of an analogue or digital signal. This document applies to measuring transducers used for converting electrical quantities such as: – current, – voltage, – active power, – reactive power, – power factor, – phase angle, – frequency, – harmonics or total harmonic distortion, – apparent power, and – DC power to an output signal. This document applies a) if the fundamental frequency of the input(s) lies between 0 Hz and 1 500 Hz, b) to the electrical measuring transducer if it is part of a system for the measurement of an electrical or non-electrical quantity, c) to transducers for use in a variety of applications such as telemetry and process control and in one of a number of defined environments. This document is not applicable for: – instrument transformers that comply with IEC 61869 (all parts), – transmitters for use in an industrial process application that comply with IEC 60770 (all parts), – power metering and monitoring devices (PMD) that comply with IEC 61557-12, – meters that comply with the IEC 62053 series, – handheld sensors, – residual current monitoring devices (RCMs) that comply with IEC 62020-1, – residual current detecting devices (RDC-DD) that comply with IEC 62955, – in-cable control and protection devices (IC-CPDs) that comply with IEC 62752, – modular residual current devices (MRCDs) that comply with IEC 60947 2:2016/AMD1:2019, Annex M. Within the measuring range, the output signal is a function of the measurand. An auxiliary supply can be required. This document is intended: – to specify the terminology and definitions relating to transducers whose main application is in industry, – to unify the test methods used in evaluating transducer performance, – to specify accuracy limits and output values for transducers. IEC 60688:2024 cancels and replaces the fourth edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating normative references; b) updating definitions; c) updating structure; d) adding DC power measurement.
- Draft124 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 63261:2024 provides requirements for the E&I objects of a digital 3D plant model, used in the engineering phase to design and construct a process plant and its instrumentation. It provides guidance how to model plants and their electrical and instrumentation equipment. This document also specifies the content and the possible output of the 3D plant model at project milestones. This document can be used by the contractual partners to agree upon the content of the 3D plant model to be delivered at specified milestones. This document does not specify the transfer and format of digital 3D plant models. This document does not specify definitions or instructions to equipment representations and details of elements in the 3D plant model not belonging to electrical and instrumentation domains.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 25.040.40
- CLC/TC 65X
IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
2022-01-12: This prAA includes common mods to prEN IEC (PR=71577)
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.140.40
- 2014/35/EU
- M/511
- CLC/TC 34
IEC 60601-2-34:2024 applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT as defined in 201.3.63, hereinafter also referred to as ME EQUIPMENT. This document applies to INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT intended for use in professional healthcare facilities and in the EMERGENCY MEDICAL SERVICE ENVIRONMENT. This document does not apply to catheter tubing, catheter needles, Luer locks, taps and tap tables that connect to the DOME. This document does not apply to non-invasive blood pressure monitoring equipment. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as follows: The clause or subclause applies to ME EQUIPMENT, as default and, only if the corresponding safety measure or function is not completely integrated into the ME EQUIPMENT but implemented as part of an ME SYSTEM, the clause or subclause applies to the ME SYSTEM. IEC 60601-2-34:2024 cancels and replaces the third edition of IEC 60601-2-34 published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision to align with IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, as well as new versions of collateral standards and amendments thereto; b) expansion of the scope to the emergency medical service environment; c) changed essential performance in Table 201.101; d) changed requirement for ingress protection; e) added primary operating functions; f) deleted Annex BB Alarm diagrams.
- Draft59 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus. Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion