EN 61300-3-35:2010
(Main)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Fibre optic connector endface visual and automated inspection
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Fibre optic connector endface visual and automated inspection
IEC 61300-3-35:2009(E) describes methods for quantitatively assessing the endface quality of a polished fibre optic connector. The information is intended for use with other standards which set requirements for allowable surface defects such as scratches, pits and debris which may affect optical performance. In general, the methods described in this standard apply to 125 m cladding fibres contained within a ferrule and intended for use with sources of 2 W of input power. This standard replaces IEC/PAS 61300-3-35 which was published in 2002.
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und Messverfahren - Teil 3-35: Untersuchungen und Messungen - Visuelle und automatisierte Inspektion der Endflächen von zylindrischen Lichtwellenleiter-Steckverbindern
Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes fondamentales d'essais et de mesure - Partie 3-35 : Examens et mesures - Inspection automatique et visuelle de la face terminale des connecteurs à fibres optiques
La CEI 61300-3-35:2009 décrit les méthodes prévues pour évaluer quantitativement la qualité de l'extrémité d'un connecteur à fibres optiques polies. Les informations sont destinées à être utilisées avec d'autres normes qui établissent les exigences pour les défauts en surface admissibles, tels que les éraflures, les piqûres et les débris qui peuvent affecter la performance optique. En général, les méthodes décrites dans la présente norme s'appliquent aux fibres à gaine de 125 ohmm contenues dans une férule et destinées à être utilisées avec des sources ≤2 W de puissance d'entrée. Toutefois, des parties sont applicables aux connecteurs exempts de férules et autres types de fibres. Ces parties sont identifiées s'il y lieu.
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni postopki - 3-35. del: Preiskave in meritve - Vizualno in avtomatično pregledovanje čela optičnega cilindričnega konektorja (IEC 61300-3-35:2009)
Ta del IEC 61300 opisuje metode za kvantitativno ocenjevanje kvalitete čela poliranega optičnega konektorja. Podatki so namenjeni za uporabo z drugimi standardi, ki postavljajo zahteve za dopustne površinske pomanjkljivosti kot so praske, jamice in smeti, ki lahko vplivajo na optično delovanje. V splošnem, metode opisane v tem standardu veljajo za 125 μm obložena vlakna, zaprta v ferulo in namenjena za uporabo z viri ≤2 W vhodne moči. Vendar deli veljajo za ne-ferule konektorje in druge vrste vlaken. Ti deli so opredeljeni po potrebi.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2010
2SWLþQLVSRMQLHOHPHQWLLQSDVLYQHNRPSRQHQWH2VQRYQLSUHVNXVQLLQPHULOQL
SRVWRSNLGHO3UHLVNDYHLQPHULWYH9L]XDOQRLQDYWRPDWLþQRSUHJOHGRYDQMH
þHODRSWLþQHJDFLOLQGULþQHJDNRQHNWRUMD,(&
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 3-35: Examinations and measurements - Fibre optic
cylindrical connector endface visual and automated inspection (IEC 61300-3-35:2009)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und
Messverfahren - Teil 3-35: Untersuchungen und Messungen - Visuelle und
automatisierte Inspektion der Endflächen von zylindrischen Lichtwellenleiter-
Steckverbindern (IEC 61300-3-35:2009)
Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes
fondamentales d'essais et de mesure - Partie 3-35 : Examens et mesures - Inspection
automatique et visuelle de la face terminale des connecteurs à fibres optiques (CEI
61300-3-35:2009)
Ta slovenski standard je istoveten z: EN 61300-3-35:2010
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61300-3-35
NORME EUROPÉENNE
January 2010
EUROPÄISCHE NORM
ICS 33.180.20
English version
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures -
Part 3-35: Examinations and measurements -
Fibre optic connector endface visual and automated inspection
(IEC 61300-3-35:2009)
Dispositifs d'interconnexion et composants Lichtwellenleiter -
passifs à fibres optiques - Verbindungselemente
Méthodes fondamentales d'essais und passive Bauteile -
et de mesure - Grundlegende Prüf- und Messverfahren -
Partie 3-35 : Examens et mesures - Teil 3-35: Untersuchungen
Inspection automatique et visuelle und Messungen -
de la face terminale des connecteurs Visuelle und automatisierte Inspektion
à fibres optiques der Endflächen von zylindrischen
(CEI 61300-3-35:2009) Lichtwellenleiter-Steckverbindern
(IEC 61300-3-35:2009)
This European Standard was approved by CENELEC on 2009-12-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61300-3-35:2010 E
Foreword
The text of document 86B/2909/FDIS, future edition 1 of IEC 61300-3-35, prepared by SC 86B, Fibre
optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-3-35 on 2009-12-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-12-01
__________
Endorsement notice
The text of the International Standard IEC 61300-3-35:2009 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
ISO 14577-2 NOTE Harmonized as EN ISO 14577-2 (not modified).
__________
IEC 61300-3-35 ®
Edition 1.0 2009-11
INTERNATIONAL
STANDARD
colour
inside
Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures –
Part 3-35: Examinations and measurements – Fibre optic connector endface
visual and automated inspection
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
S
ICS 33.180.20 ISBN 2-8318-1070-8
– 2 – 61300-3-35 © IEC:2009(E)
CONTENTS
FOREWORD.3
1 Scope.5
2 Normative references.5
3 Measurement.5
3.1 General .5
3.2 Measurement conditions .6
3.3 Pre-conditioning .6
3.4 Recovery .6
4 Apparatus.6
4.1 Method A: direct view optical microscopy .6
4.2 Method B: video microscopy .6
4.3 Method C: automated analysis microscopy.7
4.4 Calibration requirements for low and high resolution systems .7
5 Procedure.8
5.1 Measurement regions .8
5.2 Calibration procedure .8
5.3 Inspection procedure .9
5.4 Visual requirements .10
Annex A (informative) Examples of inspected end-faces with defects.12
Annex B (normative) Diagram of calibration artefact and method of manufacture .18
Bibliography .21
Figure 1 – Inspection procedure flow .9
Table 1 – Measurement regions for single fibre connectors.8
Table 2 – Measurement regions for multiple fibre rectangular ferruled connectors.8
Table 3 – Visual requirements for PC polished connectors, single mode fibre, RL 45 dB .10
Table 4 – Visual requirements for angle polished connectors (APC), single mode fibre .10
Table 5 – Visual requirements for PC polished connectors, single mode fibre, RL ≥ 26 dB .11
Table 6 – Visual requirements for PC polished connectors, multimode fibres .11
61300-3-35 © IEC:2009(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –
Part 3-35: Examinations and measurements –
Fibre optic connector endface visual and automated inspection
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61300-3-35 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This standard replaces IEC/PAS 61300-3-35 which was published in 2002.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/2909/FDIS 86B/2947/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
– 4 – 61300-3-35 © IEC:2009(E)
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of IEC 61300 series, published under the general title, Fibre optic
interconnecting devices and passive components – Basic test and measurement procedures
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under “http://webstore.iec.ch” in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this standard may be issued at a later date.
IMPORTANT – The “colour inside” logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this publication using a colour printer.
61300-3-35 © IEC:2009(E) – 5 –
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –
Part 3-35: Examinations and measurements –
Fibre optic connector endface visual and automated inspection
1 Scope
This part of IEC 61300 describes methods for quantitatively assessing the endface quality of a
polished fibre optic connector. The information is intended for use with other standards which
set requirements for allowable surface defects such as scratches, pits and debris which may
affect optical performance. In general, the methods described in this standard apply to 125 μm
cladding fibres contained within a ferrul
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.