Abstract

This European standard deals with the safety of electrically heated gullies for de-icing the inlet of the drainage system of flat roofs, balconies, and similar structures, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances.

Status
Not Published
Publication Date
21-Sep-2027
Current Stage
4020 - Enquiry circulated - Enquiry
Start Date
25-Sep-2026
Due Date
20-Apr-2026
Completion Date
25-Sep-2026

Buy Documents

Draft

prEN IEC 60335-2-83:2026

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

prEN IEC 60335-2-83:2026 is a CLC draft European standard in the IEC 60335 series for the safety of electrically heated gullies for roof drainage. It specifies particular safety requirements for appliances used to de-ice the inlet of drainage systems on flat roofs, balconies, and similar structures, for rated voltages up to 250 V, including DC supplied and battery-operated appliances.

What does prEN IEC 60335-2-83:2026 specify?

prEN IEC 60335-2-83:2026 gives particular safety requirements that supplement IEC 60335-1 for heated gullies for roof drainage. In practice, that means the reader applies the general household-appliance safety rules first, then the extra requirements in this part for the roof-drainage use case.

The document is organized into clauses 1 to 32, followed by Annex B and a bibliography. The annexes of Part 1 are applicable except where this part changes them.

AnnexWhat it covers
Annex BBattery-operated appliances, separable batteries, and detachable batteries for battery-operated appliances

What are the key requirements of prEN IEC 60335-2-83:2026?

The main requirements focus on electrical protection, water exposure, temperature rise, installation, and corrosion resistance. These points matter because heated gullies are installed outdoors and must remain safe when exposed to drainage water, low temperatures, and long service conditions.

Electrical safety and protection level

Clause 6 requires appliances to be class I, class II, or class III, and at least IPX7. For a designer or buyer, this means the product must be selected and verified against a defined protection class and a high level of water ingress protection.

Clause 27.1 adds that all conductive parts of class I appliances that can come into contact with drainage water shall be reliably connected to the earthing terminal. This is a direct safety measure for installations where water and metal parts may meet.

Test conditions that shape the design

Clause 5.6 requires thermostats to be short-circuited for the tests, and Clause 5.7 requires Clauses 10, 11, 13, and 19 to be tested at 40 °C ± 2 °C. In practice, the appliance must remain safe under more severe test conditions than normal room temperature.

Clause 3.1.9 modifies normal operation so that the appliance operates with a thermal insulation layer covering the top surface. This affects how temperature rise is assessed and reflects the way the appliance is installed in service.

Temperature rise and overheating control

Clause 11.7 requires the appliance to be operated until steady conditions are established, and Clause 11.8 reduces the temperature rises from Table 3 by 15 K. The surface of the enclosure, including any part inaccessible after installation, shall not exceed 60 K rise.

This matters because installers and purchasers need a product that does not create excessive surface temperatures after mounting in the roof drainage system.

Installation, access, and marking

Clause 7.12.1 requires the instructions to say that the appliance shall be installed in an area unlikely to be accessed. Clauses 8.1.1 and 20.2 specify that test probe 18 is not applied. Together, these clauses show that the design and instructions must reduce user access to live or hazardous parts after installation.

Construction, wiring, and durability

Clause 22.101 requires heating elements not to be detachable parts. Clause 24.101 requires thermal cut-outs used for compliance with 19.4 to be non-self-resetting thermal cut-outs. Clause 25.1 forbids an appliance inlet or pins for insertion into socket-outlets, and Clause 25.7 requires polychloroprene-sheathed supply cords.

Clause 21.1 also requires a mechanical strength test at -25 °C. For manufacturers, this means the appliance must stay sound both mechanically and electrically in cold outdoor conditions.

Moisture and corrosion resistance

Clause 15.1.2 requires parts not intended to be exposed to drainage water to be sealed before the test. Clause 31 adds a salt mist test using IEC 60068-2-52, test method 2, with a specified scratch procedure for coated enclosures. This is important for products exposed to weather and road or roof contaminants.

What terms does prEN IEC 60335-2-83:2026 define?

  • Normal operation - Clause 3.1.9 defines it for this standard as operation with a thermal insulation layer covering the top surface.
  • DC - The scope uses direct current (DC) to include appliances supplied from direct current sources.
  • Class I - One of the appliance classes allowed by Clause 6 for these heated gullies.
  • Class II - One of the appliance classes allowed by Clause 6 for these heated gullies.
  • Class III - One of the appliance classes allowed by Clause 6 for these heated gullies.
  • IPX7 - The minimum ingress-protection rating required by Clause 6.
  • Type Z attachment - A supply arrangement permitted by Clause 25.5.
  • Test probe 18 - The access probe that is not applied in Clauses 8.1.1 and 20.2, and in Annex B.

Who uses prEN IEC 60335-2-83:2026?

Manufacturers of electrically heated gullies use prEN IEC 60335-2-83:2026 to design products for flat roofs, balconies, and similar structures. Test laboratories and certification bodies use it for safety testing, including water ingress, temperature rise, mechanical strength, and corrosion checks.

It is also used by installers, specifiers, quality managers, and buyers who need to confirm that a roof-drainage heating appliance matches the required safety class, installation guidance, and outdoor-duty construction.

What changed in prEN IEC 60335-2-83:2026 from the previous edition?

This second edition cancels and replaces the first edition published in 2001 and Amendment 1:2008. The document states that it is a technical revision.

The significant technical changes listed are:

  • alignment with IEC 60335-1:2020
  • removal of test probe 18 from 8.1.1, 20.2, B.22.3, and B.22.4

Which standards are used with prEN IEC 60335-2-83:2026?

  • IEC 60335-1 - the general household-appliance safety standard that this part 2 is used with and that supplies the common requirements.
  • IEC 60068-2-52 - the salt mist test method used in Clause 31 for corrosion resistance.

What does the prEN IEC 60335-2-83:2026 document contain?

prEN IEC 60335-2-83:2026 contains clause-by-clause additions and modifications to the general safety standard, plus a normative Annex B for battery-operated appliances. It also includes a modified temperature-rise approach, special test conditions for hot and cold exposure, and a corrosion test based on IEC 60068-2-52.

For practical work, the document is used for design checks, type testing, certification, and conformity assessment of heated gullies for roof drainage. Its content is focused on the safety questions that matter most outdoors: live parts, water exposure, overheating, mechanical strength, earthing, and long-term resistance to rusting.

Relations

Effective Date
29-Sep-2026
Effective Date
14-Apr-2025
Effective Date
14-Apr-2025

Buy Documents

Draft

prEN IEC 60335-2-83:2026

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

prEN IEC 60335-2-83:2026 is a draft published by CLC. Its full title is "Household and similar electrical appliances - Safety - Part 2-83: Particular requirements for heated gullies for roof drainage". This standard covers: This European standard deals with the safety of electrically heated gullies for de-icing the inlet of the drainage system of flat roofs, balconies, and similar structures, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances.

This European standard deals with the safety of electrically heated gullies for de-icing the inlet of the drainage system of flat roofs, balconies, and similar structures, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances.

prEN IEC 60335-2-83:2026 is classified under the following ICS (International Classification for Standards) categories: 91.060.20 - Roofs. The ICS classification helps identify the subject area and facilitates finding related standards.

prEN IEC 60335-2-83:2026 has the following relationships with other standards: It is inter standard links to EN IEC 60068-2-52:2018, EN 60335-2-83:2002, EN 60335-2-83:2002/A1:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

prEN IEC 60335-2-83:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511, M/536. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

prEN IEC 60335-2-83:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2026
Gospodinjski in podobni električni aparati - Varnost - 2-83. del: Posebne zahteve
za ogrevanje strešnih žlebov
Household and similar electrical appliances - Safety - Part 2-83: Particular requirements
for heated gullies for roof drainage
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-83:
Besondere Anforderungen für beheizbare Dachabläufe
Appareils électrodomestiques et analogues - Sécurité - Partie 2-83: Exigences
particulières pour les dispositifs électriques pour le chauffage des gouttières
Ta slovenski standard je istoveten z: prEN IEC 60335-2-83:2026
ICS:
13.120 Varnost na domu Domestic safety
91.060.20 Strehe Roofs
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

IEC 60335-2-83 ®
Edition 2.0 2024-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –

Part 2-83: Particular requirements for heated gullies for roof drainage

Appareils électrodomestiques et analogues – Sécurité –

Partie 2-83: Exigences particulières pour les dispositifs électriques pour le

chauffage des gouttières
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 91.060.20  ISBN 978-2-8322-9690-5

– 2 – IEC 60335-2-83:2024 © IEC 2024
CONTENTS
FOREWORD . 3
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 General requirement . 8
5 General conditions for the tests . 8
6 Classification . 8
7 Marking and instructions . 8
8 Protection against access to live parts . 8
9 Starting of motor-operated appliances . 8
10 Power input and current . 9
11 Heating . 9
12 Charging of metal-ion batteries . 9
13 Leakage current and electric strength at operating temperature . 9
14 Transient overvoltages . 9
15 Moisture resistance . 9
16 Leakage current and electric strength . 9
17 Overload protection of transformers and associated circuits . 9
18 Endurance . 10
19 Abnormal operation . 10
20 Stability and mechanical hazards . 10
21 Mechanical strength . 10
22 Construction . 10
23 Internal wiring . 10
24 Components . 10
25 Supply connection and external flexible cords . 11
26 Terminals for external conductors . 11
27 Provision for earthing . 11
28 Screws and connections . 11
29 Clearances, creepage distances and solid insulation . 11
30 Resistance to heat and fire . 11
31 Resistance to rusting . 11
32 Radiation, toxicity and similar hazards . 12
Annexes . 13
Annex B (normative) Battery-operated appliances, separable batteries and detachable
batteries for battery-operated appliances . 14
Bibliography . 15

IEC 60335-2-83:2024 © IEC 2024 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-83: Particular requirements for heated gullies for roof drainage

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 60335-2-83 has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances. It is an International Standard.
This second edition cancels and replaces the first edition published in 2001 and
Amendment 1:2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) alignment with IEC 60335-1:2020;
b) removal of test probe 18 (8.1.1, 20.2, B.22.3, B.22.4).

– 4 – IEC 60335-2-83:2024 © IEC 2024
The text of this International Standard is based on the following documents:
Draft Report on voting
61/7274/FDIS 61/7300/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all parts of the IEC 60335 series, under the general title: Household and similar
electrical appliances – Safety, can be found on the IEC website.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments unless that edition precludes it; in that case, the latest edition that does not
preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
NOTE 1 When "part 1" is mentioned in this standard, it refers to IEC 60335-1.
This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to convert
that publication into the IEC standard: Particular requirements for heated gullies for roof
drainage.
When a particular subclause of part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. When this standard states "addition", "modification", or "replacement",
the relevant text in part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in part 1, they are numbered start
...