Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage

This clause of Part 1 is applicable, except as follows: Replace the first paragraph by the following: This standard applies to residual current operated circuit-breakers with integral overcurrent protection (RCBO's) functionally independent of line voltage, for household and similar uses incorporating overcurrent protection having rated voltages not exceeding 440 V a.c. rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A, for operation at 50 Hz or 60 Hz.

Fehlerstrom-Schutzschalter mit Überstromauslöser (RCBO's) für Hausinstallationen und für ähnliche Anwendungen - Teil 2-1: Anwendbarkeit der Festlegungen für die Funktion des RCBO's unabhänging von der Netzspannung

Interrupteurs automatiques à courant différentiel résiduel avec protection contre les surintensités incorporée pour installations domestiques et analogues (DD) - Partie 2-1: Applicabilité des règles générales aux DD fonctionnellement indépendants de la tension d'alimentation

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCOB's) - Part 2-1: Applicability of the general rules to RCOB's functionally independent of line voltage (IEC 1009-2-1:1991)

Ta točka 1. dela se uporablja, razen kot sledi: Prvi odstavek je treba nadomestiti z: Ta standard se uporablja za odklopnike na preostali (residualni) tok z vgrajeno nadtokovno zaščito za gospodinjsko in podobno rabo (RCBO's), ki so funkcionalno neodvisni od linijske napetosti in uporabljajo nadtokovno zaščito, pri čemer nazivna izmenična napetost ne presega 440 V, nazivni tok ne presega 125 A, nazivne kratkostične zmogljivosti pa ne presegajo 25.000 A med delovanjem pri 50 Hz ali 60 Hz.

General Information

Status
Published
Publication Date
04-Aug-1994
Withdrawal Date
30-Jun-2000
Current Stage
6060 - Document made available - Publishing
Start Date
05-Aug-1994
Completion Date
05-Aug-1994

Relations

Buy Standard

Standard
EN 61009-2-1:1996
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-1996
Residual current operated circuit-breakers with integral overcurrent protection for
household and similar uses (RCOB's) - Part 2-1: Applicability of the general rules
to RCOB's functionally independent of line voltage (IEC 1009-2-1:1991)
Residual current operated circuit-breakers with integral overcurrent protection for
household and similar uses (RCBO's) -- Part 2-1: Applicability of the general rules to
RCBO's functionally independent of line voltage
Fehlerstrom-Schutzschalter mit Überstromauslöser (RCBO's) für Hausinstallationen und
für ähnliche Anwendungen -- Teil 2-1: Anwendbarkeit der Festlegungen für die Funktion
des RCBO's unabhänging von der Netzspannung
Interrupteurs automatiques à courant différentiel résiduel avec protection contre les
surintensités incorporée pour installations domestiques et analogues (DD) -- Partie 2-1:
Applicabilité des règles générales aux DD fonctionnellement
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.