IEC 61097-5:1997
(Main)Global maritime distress and safety system (GMDSS) - Part 5: Inmarsat-E - Emergency position indicating radio beacon (EPIRB) operating through the Inmarsat system - Operational and performance requirements, methods of testing and required test results
Global maritime distress and safety system (GMDSS) - Part 5: Inmarsat-E - Emergency position indicating radio beacon (EPIRB) operating through the Inmarsat system - Operational and performance requirements, methods of testing and required test results
Specifies the minimum operational and performance requirements, technical characteristics, methods of testing and required test results of the satellite emergency position indicating radio beacon used in the Inmarsat-E satellite system.
General Information
Buy Standard
Standards Content (Sample)
INTERNATIONAL
IEC
STANDARD 61097-5
First edition
1997-12
Global maritime distress and safety
system (GMDSS) –
Part 5:
Inmarsat-E – Emergency position indicating
radio beacon (EPIRB) operating through the
Inmarsat system – Operational and performance
requirements, methods of testing and required
test results
Système mondial de détresse et de sécurité
en mer (SMDSM) –
Partie 5:
Inmarsat-E – Balises radioélectriques de position de détresse
du système Inmarsat – Exigences d’exploitation et de
fonctionnement, méthodes d’essai et résultats d’essai exigés
Reference number
IEC 61097-5: 1997(E)
Numéros des publications Numbering
Depuis le 1er janvier 1997, les publications de la CEI As from the 1st January 1997 all IEC publications are
sont numérotées à partir de 60000. issued with a designation in the 60000 series.
Publications consolidées Consolidated publications
Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant les amendements sont disponibles. including amendments are available. For example,
Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to
indiquent respectivement la publication de base, la the base publication, the base publication
publication de base incorporant l’amendement 1, et la incorporating amendment 1 and the base publication
publication de base incorporant les amendements 1 incorporating amendments 1 and 2.
et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept under
constamment revu par la CEI afin qu'il reflète l'état constant review by the IEC, thus ensuring that the
actuel de la technique. content reflects current technology.
Des renseignements relatifs à la date de Information relating to the date of the reconfirmation of
reconfirmation de la publication sont disponibles dans the publication is available in the IEC catalogue.
le Catalogue de la CEI.
Les renseignements relatifs à ces révisions, à l'établis- Information on the revision work, the issue of revised
sement des éditions révisées et aux amendements editions and amendments may be obtained from
peuvent être obtenus auprès des Comités nationaux de IEC National Committees and from the following
la CEI et dans les documents ci-dessous: IEC sources:
• Bulletin de la CEI • IEC Bulletin
• Annuaire de la CEI • IEC Yearbook
Accès en ligne* On-line access*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
(Accès en ligne)* (On-line access)*
Terminologie, symboles graphiques Terminology, graphical and letter
et littéraux symbols
En ce qui concerne la terminologie générale, le lecteur For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire Electro- IEC 60050: International Electrotechnical Vocabulary
technique International (VEI). (IEV).
For graphical symbols, and letter symbols and signs
Pour les symboles graphiques, les symboles littéraux
et les signes d'usage général approuvés par la CEI, le approved by the IEC for general use, readers are
lecteur consultera la CEI 60027: Symboles littéraux à referred to publications IEC 60027: Letter symbols to
utiliser en électrotechnique, ymboles be used in electrical technology, IEC 60417: Graphical
la CEI 60417: S
graphiques utilisables sur le matériel. Index, relevé et symbols for use on equipment. Index, survey and
compilation des feuilles individuelles, et la CEI 60617: compilation of the single sheets and IEC 60617:
Graphical symbols for diagrams.
Symboles graphiques pour schémas.
Publications de la CEI établies par IEC publications prepared by the same
le même comité d'études technical committee
The attention of readers is drawn to the end pages of
L'attention du lecteur est attirée sur les listes figurant
à la fin de cette publication, qui énumèrent les this publication which list the IEC publications issued
publications de la CEI préparées par le comité by the technical committee which has prepared the
d'études qui a établi la présente publication. present publication.
* Voir adresse «site web» sur la page de titre. * See web site address on title page.
INTERNATIONAL
IEC
STANDARD
61097-5
First edition
1997-12
Global maritime distress and safety
system (GMDSS) –
Part 5:
Inmarsat-E – Emergency position indicating
radio beacon (EPIRB) operating through the
Inmarsat system – Operational and performance
requirements, methods of testing and required
test results
Système mondial de détresse et de sécurité
en mer (SMDSM) –
Partie 5:
Inmarsat-E – Balises radioélectriques de position de détresse
du système Inmarsat – Exigences d’exploitation et de
fonctionnement, méthodes d’essai et résultats d’essai exigés
IEC 1997 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including
photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
Commission Electrotechnique Internationale
PRICE CODE
X
International Electrotechnical Commission
For price, see current catalogue
– 2 – 61097-5 © IEC:1997(E)
CONTENTS
Page
FOREWORD . 5
Clause
1 Scope . 6
2 Normative references. 7
3 Definitions and abbreviations. 8
3.1 Definitions . 8
3.2 Abbreviations . 10
4 General and operational requirements. 10
4.1 Purpose . 10
4.2 General . 11
4.3 Operational . 11
4.4 Float-free release . 12
4.5 Maintenance. 12
4.6 Safety precautions. 12
4.7 Safety from electromagnetic RF radiation. 12
4.8 Equipment handbook . 12
4.9 Labelling . 13
4.10 Installation. 14
5 Technical characteristics. 14
5.1 Purpose . 14
5.2 General . 14
5.3 Operational . 14
5.4 Manual distress alert initiation. 15
5.5 Float-free arrangements . 16
5.6 Transmission delay on activation . 16
5.7 Satellite signal frequency. 17
5.8 Technical characteristics and message format . 17
5.9 Distress message. 18
5.10 Ship station identity . 18
5.11 Test facilities . 18
5.12 Modulation, frequency shift and coding . 19
5.13 Antenna characteristics . 19
5.14 Radiation and output power . 19
5.15 Total transmission duration. 19
5.16 Duty cycle . 19
5.17 Power source . 20
5.18 Environment . 20
5.19 Safety precautions. 21
5.20 Interference EMC . 21
5.21 Compass safe distance . 21
61097-5 © IEC:1997(E) – 3 –
Clause Page
6 Methods of testing and required test results . 21
6.1 General . 21
6.2 Test frequency . 22
6.3 Additional facilities. 22
6.4 Test arrangements . 22
6.5 Test conditions . 23
6.6 Normal test conditions . 23
6.7 Extreme test conditions . 23
6.8 Climatic control systems. . 23
6.9 Test sequence. 23
6.10 Performance check. 24
6.11 Performance test. 24
6.12 Performance criteria . 24
6.13 Measurement uncertainty. 24
7 Environmental tests. 25
7.1 General . 25
7.2 Dry heat . 25
7.3 Damp heat . 25
7.4 Low temperature . 25
7.5 Thermal shock. 25
7.6 Immersion . 25
7.7 Drop test into water . 25
7.8 Vibration. 25
7.9 Ruggedness . 26
7.10 Rain . 26
7.11 Solar radiation . 26
7.12 Oil resistance . 26
7.13 Corrosion . 26
7.14 Safety criteria for batteries. 26
8 Tests of technical characteristics. 27
8.1 General . 27
8.2 Power source capacity test at low temperature test . 30
8.3 Antenna characteristics, radiation and output power. 30
8.4 Output power under extreme test voltage. 31
8.5 Transmitter. 32
8.6 Signal format. 33
8.7 Antenna mismatch. 33
9 Safety . 33
9.1 Electromagnetic RF radiation.
...








Questions, Comments and Discussion