Information technology - Generic cabling for customer premises - Part 2: Office premises

ISO/IEC 11801-2:2017(E) This document specifies generic cabling within and between the buildings of office premises, or office spaces within other types of building. Additionally those premises can include industrial spaces (for which generic cabling is specified in ISO/IEC 11801-3) or data centre spaces (for which generic cabling is specified in ISO/IEC 11801-5).
The contents of the corrigendum of April 2018 have been included in this copy.

General Information

Status
Published
Publication Date
12-Nov-2017
Current Stage
PPUB - Publication issued
Start Date
14-Dec-2017
Completion Date
13-Nov-2017
Ref Project

Relations

Buy Standard

Standard
ISO/IEC 11801-2:2017 - Information technology - Generic cabling for customer premises - Part 2: Office premises
English language
24 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


ISO/IEC 11801-2
Edition 1.0 2017-11
INTERNATIONAL
STANDARD
Information technology – Generic cabling for customer premises –
Part 2: Office premises
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about
ISO/IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address
below or your local IEC member National Committee for further information.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the

latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in
Technical Specifications, Technical Reports and other English and French, with equivalent terms in 16 additional
documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical
iPad. Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and
variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of
committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been
and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and

CISPR.
IEC Just Published - webstore.iec.ch/justpublished

Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
ISO/IEC 11801-2
Edition 1.0 2017-11
INTERNATIONAL
STANDARD
Information technology – Generic cabling for customer premises –

Part 2: Office premises
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 35.200 ISBN 978-2-8322-5034-1

– 2 – ISO/IEC 11801-2:2017 © ISO/IEC 2017
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 8
2 Normative references . 8
3 Terms, definitions and abbreviated terms . 8
3.1 Terms and definitions . 8
3.2 Abbreviated terms . 9
4 Conformance . 9
5 Structure of the generic cabling system . 10
5.1 General . 10
5.2 Functional elements . 10
5.3 General structure and hierarchy . 11
5.3.1 General . 11
5.3.2 Campus and building backbone cabling subsystem . 11
5.3.3 Horizontal cabling subsystem . 11
5.3.4 Design objectives . 11
5.4 Interconnection of subsystems . 12
5.4.1 General . 12
5.4.2 Centralized cabling architecture . 12
5.5 Accommodation of functional elements . 12
5.6 Dimensioning and configuring . 13
5.6.1 Distributors . 13
5.6.2 Connecting hardware . 15
5.6.3 Work area cords and equipment cords . 15
5.6.4 Patch cords and jumpers . 15
5.6.5 Telecommunications outlet . 15
5.6.6 Consolidation point . 16
5.6.7 Telecommunications rooms and equipment rooms . 17
5.6.8 External services cabling . 17
6 Channel performance requirements . 17
6.1 General . 17
6.2 Environmental performance . 18
6.3 Transmission performance . 18
6.3.1 General . 18
6.3.2 Balanced cabling . 19
6.3.3 Optical fibre cabling . 19
7 Link performance requirements . 19
7.1 General . 19
7.2 Balanced cabling . 19
7.3 Optical fibre cabling . 19
8 Reference implementations . 20
8.1 General . 20
8.2 Balanced cabling . 20
8.2.1 General . 20
8.2.2 Horizontal cabling . 20
8.2.3 Campus and building backbone cabling system . 23

8.3 Optical fibre cabling . 23
8.3.1 General . 23
8.3.2 Component selection . 23
8.3.3 Dimensions . 23
9 Cable requirements . 25
9.1 General . 25
9.2 Balanced cables . 26
9.3 Optical fibre cables . 26
10 Connecting hardware requirements . 26
10.1 General requirements . 26
10.2 Connecting hardware for balanced cabling . 26
10.2.1 General requirements . 26
10.2.2 Electrical, mechanical and environmental performance . 26
10.3 Connecting hardware for optical fibre cabling . 27
10.3.1 General requirements . 27
10.3.2 Optical, mechanical and environmental performance . 27
11 Cord requirements . 27
11.1 Jumpers . 27
11.2 Balanced cords . 27
11.2.1 General . 27
11.2.2 Additional requirements for work area cords . 27
11.3 Optical fibre cords . 27
Bibliography . 28

Figure 1 – Relationships between the generic cabling documents produced by
ISO/IEC JTC 1/SC 25 . 6
Figure 2 – Structure of generic cabling . 11
Figure 3 – Hierarchical structure of generic cabling . 12
Figure 4 – Structures for centralized generic cabling . 12
Figure 5 – Accommodation of functional elements . 13
Figure 6 – Example of a generic cabling system with combined BD and FD . 14
Figure 7 – Inter-relationship of functional elements in an installation with redundancy . 15
Figure 8 –Channel, permanent link and CP link . 18
Figure 9 – Example of a system showing the location of cabling interfaces and extent
of associated channels . 18
Figure 10 – Horizontal cabling models . 21
Figure 11 – Combined backbone/horizontal channels. 25

Table 1 – Maximum channel lengths . 14
Table 2 – Length assumptions used in the mathematical modelling of balanced
horizontal cabling . 22
Table 3 – Horizontal link length equations . 22

– 4 – ISO/IEC 11801-2:2017 © ISO/IEC 2017
INFORMATION TECHNOLOGY –
GENERIC CABLING FOR CUSTOMER PREMISES –

Part 2: Office premises
FOREWORD
1) ISO (the International Organization for Standardization) and IEC (the International Electrotechnical
Commission) form the specialized system for worldwide standardization. National bodies that are members of
ISO or IEC participate in the development of International Standards through technical committees established
by the respective organization to deal with particular fields of technical activity. ISO and IEC technical
committees collaborate in fields of mutual interest. Other international organizations, governmental and non-
governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology,
ISO and IEC have established a joint technical committee, ISO/IEC JTC 1.
2) The formal decisions or agreements of IEC and ISO on technical matters express, as nearly
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.