Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems

This part of IEC 61000 is concerned with conducted disturbances in the frequency range from 0 kHz to 9 kHz, with an extension up to 148,5 kHz specifically for mains signalling systems. Compatibility levels are specified for electromagnetic disturbances of the types which can be expected in public medium voltage power supply systems, for guidance in: a) the limits to be set for disturbance emission into public power supply systems (including the planning levels defined in 3.1.5); b) the immunity limits to be set by product committees and others for the equipment exposed to the conducted disturbances present in public power supply systems. The disturbance phenomena considered are: voltage fluctuations and flicker, harmonics up to and including order 50, inter-harmonics up to the 50th harmonic, voltage distortions at higher frequencies (above 50th harmonic), voltage dips and short supply interruptions, voltage unbalance, transient overvoltages, power frequency variation, d.c. components, mains signalling. The medium-voltage systems covered by this standard are public distribution systems supplying either: a) private installations in which equipment is connected directly or through transformers, or b) substations feeding public low-voltage distribution systems.

Compatibilité électromagnétique (CEM) - Partie 2-12: Environnement - Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d'alimentation moyenne tension

La présente partie de la CEI 61000 s'applique aux perturbations conduites dans le domaine de fréquence de 0 kHz à 9 kHz, avec une extension jusqu'à 148,5 kHz pour les systèmes de transmission de signaux sur le réseau. Les niveaux de compatibilité sont donnés pour les types de perturbations électromagnétiques auxquelles on peut s'attendre sur les réseaux de distribution publics moyenne tension, dans le but d'aider à définir: a) les limites devant être établies pour les émissions perturbatrices sur les réseaux publics de distribution d'énergie (comprenant également les niveaux de planification tels que définis en 3.1.5); b) les limites d'immunité devant être établies par les comités de produit ou autres concernant les équipements soumis aux perturbations conduites par les réseaux publics de distribution d'énergie. Les phénomènes perturbateurs considérés sont: les fluctuations de tension et le flicker, les harmoniques jusque et y compris le rang 50, les interharmoniques jusqu'au rang 50, les distorsions de tension aux fréquences supérieures (au-dessus du rang 50), les creux de tension et les coupures brèves, le déséquilibre de tension, les surtensions transitoires, les variations de fréquence, les composantes continues, les systèmes de transmission de signaux sur le réseau. Les réseaux moyenne tension couverts par cette norme sont des réseaux de distribution publics alimentant: a) soit des installations privées dans lesquelles le matériel est raccordé directement ou à travers de transformateurs, b) soit des postes de transformation alimentant des réseaux de distribution publics basse tension.

General Information

Status
Published
Publication Date
23-Apr-2003
Current Stage
PPUB - Publication issued
Start Date
15-Sep-2003
Completion Date
24-Apr-2003
Ref Project

Buy Standard

Standard
IEC 61000-2-12:2003 - Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
English and French language
55 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NORME CEI
INTERNATIONALE IEC
61000-2-12
INTERNATIONAL
Première édition
STANDARD
First edition
2003-04
Compatibilité électromagnétique (CEM) –
Partie 2-12:
Environnement – Niveaux de compatibilité
pour les perturbations conduites à basse
fréquence et la transmission des signaux
sur les réseaux publics d'alimentation
moyenne tension
Electromagnetic compatibility (EMC) –
Part 2-12:
Environment – Compatibility levels for
low-frequency conducted disturbances and
signalling in public medium-voltage power
supply systems
Numéro de référence
Reference number
CEI/IEC 61000-2-12:2003

---------------------- Page: 1 ----------------------
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(http://www.iec.ch/searchpub/cur_fut.htm) vous permet (http://www.iec.ch/searchpub/cur_fut.htm) enables
de faire des recherches en utilisant de nombreux you to search by a variety of criteria including text
critères, comprenant des recherches textuelles, par searches, technical committees and date of
comité d’études ou date de publication. Des publication. On-line information is also available
informations en ligne sont également disponibles sur on recently issued publications, withdrawn and
les nouvelles publications, les publications rempla- replaced publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(http://www.iec.ch/online_news/justpub/jp_entry.htm) (http://www.iec.ch/online_news/justpub/jp_entry.htm)
est aussi disponible par courrier électronique. is also available by email. Please contact the
Veuillez prendre contact avec le Service client Customer Service Centre (see below) for further
(voir ci-dessous) pour plus d’informations. information.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.

---------------------- Page: 2 ----------------------
NORME CEI
INTERNATIONALE IEC
61000-2-12
INTERNATIONAL
Première édition
STANDARD
First edition
2003-04
Compatibilité électromagnétique (CEM) –
Partie 2-12:
Environnement – Niveaux de compatibilité
pour les perturbations conduites à basse
fréquence et la transmission des signaux
sur les réseaux publics d
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.