IEC 61000-5-7:2001
(Main)Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code)
Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection provided by enclosures against electromagnetic disturbances (EM code)
Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.
Compatibilité électromagnétique (CEM) - Partie 5-7: Guide d'installation et d'atténuation - Degrés de protection procurés par les enveloppes contre les perturbations électromagnétiques (Code EM)
Spécifie les prescriptions, les méthodes d'essai et de classification applicables aux degrés de protection contre les perturbations électromagnétiques offerts par des enveloppes vides, pour les fréquences comprises entre 10 kHz et 40 GHz. La protection par blindage est mesurée pour montrer que l'enveloppe fournit un blindage adéquat à l'épreuve de l'énergie électromagnétique pour assurer des caractéristiques de fonctionnement acceptables des unités assemblées complètes lorsqu'elles sont soumises aux essais selon les normes CEI applicables. La présente norme a pour objet de fournir un moyen reproductible pour l'évaluation des performances de blindage électromagnétique des enveloppes mécaniques vides y compris les coffrets et les bâtis et de spécifier un code de marquage pour permettre à un fabricant de choisir une enveloppe avec une capacité d'atténuer des champs électromagnétiques connue. Les prescriptions d'immunité pour différents types de perturbations électromagnétiques y compris les impulsions de foudre et électromagnétiques nucléaires à haute altitude (IEM-HA) seront examinées par les constructeurs lorsqu'ils détermineront le besoin d'application de la présente norme pour des équipements et des applications spécifiques et pour les prescriptions des enveloppes de blindage spécifiques nécessaires en fonction de la fréquence.
General Information
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
61000-5-7
INTERNATIONAL
Première édition
STANDARD
First edition
2001-01
PUBLICATION FONDAMENTALE EN CEM
BASIC EMC PUBLICATION
Compatibilité électromagnétique (CEM) –
Partie 5-7:
Guide d'installation et d'atténuation –
Degrés de protection procurés par les enveloppes
contre les perturbations électromagnétiques
(Code EM)
Electromagnetic compatibility (EMC) –
Part 5-7:
Installation and mitigation guidelines –
Degrees of protection provided by enclosures
against electromagnetic disturbances (EM code)
Numéro de référence
Reference number
CEI/IEC 61000-5-7:2001
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61000-5-7
INTERNATIONAL
Première édition
STANDARD
First edition
2001-01
PUBLICATION FONDAMENTALE EN CEM
BASIC EMC PUBLICATION
Compatibilité électromagnétique (CEM) –
Partie 5-7:
Guide d'installation et d'atténuation –
Degrés de protection procurés par les enveloppes
contre les perturbations électromagnétiques
(Code EM)
Electromagnetic compatibility (EMC) –
Part 5-7:
Installation and mitigation guidelines –
Degrees of protection provided by enclosures
against electromagnetic disturbances (EM code)
IEC 2001 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
U
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61000-5-7 CEI:2001
SOMMAIRE
Pages
AVANT-PROPOS .4
INTRODUCTION.6
Articles
1 Domaine d'application.8
2 Références normatives .10
3 Généralités.10
4 Définitions .12
5 Désignations des performances du blindage .18
6 Approche générale d'essai.20
7 Prescriptions d'essai.22
7.1 Conditions climatiques.22
7.2 Echantillons.24
7.3 Prescriptions d'analyse .24
7.4 Choix de la fréquence d'essai .24
7.5 Définition de la matrice d'essai .26
7.6 Prescriptions pour l'équipement d'essai .26
7.7 Prescriptions de sécurité .26
7.8 Prescriptions pour le plan d'essai.28
7.9 Caractéristiques des essais .28
7.10 Conclusions des essais .40
7.11 Documentation d'essai.40
8 Classification .40
Annexe A (informative) Points à observer pour le choix des prescriptions de protection
électromagnétique des enveloppes.42
Annexe B (informative) Résumé des responsabilités des Comités d’Etudes de Produit
final compétents.44
Annexe C (informative) Autres méthodes d'essai – cellules TEM et lignes à ruban .46
Annexe D (informative) Antennes .48
Bibliographie .50
Figure 1 – Montage d'essai de l'efficacité de blindage pour la gamme des basses
fréquences – fibres optiques .32
Figure 2 – Montage d'essai de l'efficacité de blindage pour la gamme des basses
fréquences – câblé (les polarisations multiples doivent être utilisées comme à la figure 1) .34
Figure 3 – Exemple de montage d'essai d'étalonnage pour les essais dans la gamme
des basses fréquences .36
Figure 4 – Exemple de configuration de mesure d’étalonnage pour les essais à basse
fréquence.38
Tableau 1 – Désignations de code de blindage EM .18
Tableau 2 – Prescriptions pour un équipement type pour les essais destinés à évaluer
l'efficacité de blindage d'une enveloppe.26
61000-5-7 IEC:2001 – 3 –
CONTENTS
Page
FOREWORD.5
INTRODUCTION.7
Clause
1 Scope.9
2 Normative references.11
3 General .11
4 Definitions .13
5 Shielding performance designations.19
6 General test approach .21
7 Testing requirements .23
7.1 Climatic conditions.23
7.2 Test samples.25
7.3 Analysis requirements.25
7.4 Test frequency selection .25
7.5 Test matrix definition .27
7.6 Test equipment requirements.27
7.7 Safety requirements.27
7.8 Test plan requirements .29
7.9 Test performance .29
7.10 Test conclusions.41
7.11 Test documentation .41
8 Classification .41
Annex A (informative) Some issues for selection of enclosure electromagnetic
protection requirements.43
Annex B (informative) Summary of responsibilities of relevant end-product technical
committees .45
Annex C (informative) Other test methods – TEM cells and striplines.47
Annex D (informative) Antennas .49
Bibliography .51
Figure 1 – Shielding effectiveness test set-up for low-frequency range – fibre optic.33
Figure 2 – Shielding effectiveness test set-up for low-frequency range – hardwired
(multiple polarisations are to be used as in figure 1) .35
Figure 3 – Example noise measurement configuration for low-frequency range testing.37
Figure 4 – Example calibration test set-up for low-frequency range testing.39
Table 1 – EM shielding code designators.19
Table 2 – Enclosure shielding effectiveness typical test equipment requirements .27
– 4 – 61000-5-7 CEI:2001
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
–––––––––––
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –
Partie 5-7: Guide d'installation et d'atténuation –
Degrés de protection procurés par les enveloppes
contre les perturbations électromagnétiques (Code EM)
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes Internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques, représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités
nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n'a fixé aucune procédure concernant le marquage comme indication d'approbation et sa responsabilité
n'est pas engagée quand un matériel est déclaré conforme à l'une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61000-5-7 a été établie par le sous-comité 77C: Phénomènes
transitoires de forte intensité, du comité d’études 77 de la CEI: Compatibilité électro-
magnétique. Elle a le statut de publication fondamentale en CEM conformément au Guide 107
de la CEI.
La texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
77C/96/FDIS 77C/102/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 3.
Les annexes A, B, C et D sont données uniquement à titre d’information.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2007. A cette
date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
61000-5-7 IEC:2001 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 5-7: Installation and mitigation guidelines –
Degrees of protection provided by enclosures against
electromagnetic disturbances (EM code)
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organisation for standardisation comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardisation in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organisations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organisation
for Standardisation (ISO) in accordance with conditions determined by agreement between the two
organisations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-5-7 has been prepared by subcommittee 77C, High power
transient phenomena, of IEC technical committee 77: Electromagnetic compatibility (EMC). It
has the status of a basic EMC publication in accordance with IEC Guide 107.
The text of this standard is based on the following documents:
FDIS Report on voting
77C/96/FDIS 77C/102/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annexes A, B, C and D are given for information only.
The committee has decided that the contents of this publication will remain unchanged until
2007. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 6 – 61000-5-7 CEI:2001
INTRODUCTION
La CEI 61000 est publiée sous forme de plusieurs parties conformément à la structure suivante:
Partie 1: Généralités
Considérations générales (introduction, principes fondamentaux)
Définitions, terminologie
Partie 2: Environnement
Description de l’environnement
Classification de l’environnement
Niveaux de compatibilité
Partie 3: Limites
Limites d’émission
Limites d’immunité (dans la mesure où elles ne relèvent pas de la responsabilité des
comités de produits)
Partie 4: Techniques d’essai et de mesure
Techniques de mesure
Techniques d’essai
Partie 5: Guides pour l’installation et l’atténuation
Guides pour l’installation
Méthodes et dispositifs d’atténuation
Partie 6: Normes génériques
Partie 9: Divers
Chaque partie est à son tour subdivisée en plusieurs parties, publiées soit comme Normes
internationales, soit comme spécifications techniques ou rapports techniques, dont certaines
ont déjà été publiées en tant que sections. D’autres seront publiées sous le numéro de la
partie, suivi d’un tiret et complété d’un second chiffre identifiant la subdivision (exemple:
61000-6-1).
La présente partie de la CEI 61000 définit un code de marquage des caractéristiques de
blindage électromagnétique ainsi que les exigences et procédures applicables aux essais
destinés à vérifier les caractéristiques de blindage des enveloppes vides pour matériels
électriques et électroniques.
61000-5-7 IEC:2001 – 7 –
INTRODUCTION
IEC 61000 is published in separate parts according to the following structure:
Part 1: General
General consideration (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (in so far as they do not fall under responsibility of the product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 6: Generic standards
Part 9: Miscellaneous
Each part is further subdivided into several parts, published either as International Standards,
technical specifications or technical reports, some of which have already been published as
sections. Others will be published with the part number followed by a dash and completed by a
second number identifying the subdivision (example: 61000-6-1).
This part of IEC 61000 gives electromagnetic shielding performance markings, and test
requirements and procedures related to the electromagnetic shielding performance of empty
electrical and electronics equipment enclosures.
– 8 – 61000-5-7 CEI:2001
COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –
Partie 5-7: Guide d'installation et d'atténuation –
Degrés de protection procurés par les enveloppes
contre les perturbations électromagnétiques (Code EM)
1 Domaine d'application
La présente partie de la CEI 61000 spécifie les prescriptions, les méthodes d'essai et de
classification applicables aux degrés de protection contre les perturbations électromagnétiques
offerts par des enveloppes vides, pour les fréquences comprises entre 10 kHz et 40 GHz. Les
performances du blindage sont à mesurer avant l'installation des équipements et composants
électriques et/ou électroniques internes. Cette protection par blindage est mesurée pour
montrer que l'enveloppe fournit un blindage adéquat à l'épreuve de l'énergie électromagnétique
pour assurer des caractéristiques de fonctionnement acceptables des unités assemblées
complètes lorsqu'elles sont soumises aux essais selon les normes CEI applicables. A noter
cependant que des caractéristiques satisfaisantes pour une enveloppe vide ne donnent pas
nécessairement l'assurance que les unités complètes subiront avec succès toutes les normes
d'essais de performances CEM pour un équipement en fonctionnement (voir les remarques de
l'annexe A).
La présente norme a pour objet de fournir un moyen reproductible pour l'évaluation des
performances de blindage électromagnétique des enveloppes mécaniques vides y compris les
coffrets et les bâtis et de spécifier un code de marquage pour permettre à un fabricant de
choisir une enveloppe avec une capacité d’atténuer des champs électromagnétiques connue.
Les prescriptions d'immunité pour différents types de perturbations électromagnétiques y
compris les impulsions de foudre et électromagnétiques nucléaires à haute altitude (IEM-HA)
seront examinées par les constructeurs lorsqu'ils détermineront le besoin d'application de la
présente norme pour des équipements et des applications spécifiques et pour les prescriptions
des enveloppes de blindage spécifiques nécessaires en fonction de la fréquence.
L'adoption du système de classification de la présente norme permettra, lorsque cela sera
possible, de promouvoir l'uniformité des méthodes de description de la protection contre les
contraintes électromagnétiques fournie par l'enveloppe. Ceci inclut la protection de
l'équipement, à l'intérieur de l'enveloppe, contre les contraintes électromagnétiques externes
ainsi que la protection de l'équipement extérieur contre les contraintes électromagnétiques
produites à l'intérieur.
Les comités techniques responsables des enveloppes peuvent décider individuellement dans
quelle mesure et de quelle manière la classification définie dans la présente norme sera
utilisée dans leurs normes et de définir le terme «enveloppe» et la manière dont il s'applique à
leur équipement. Cependant, les essais et les catégories de performance ne peuvent pas être
différents de ceux qui sont spécifiés dans cette norme. L'annexe B donne un guide informatif
pour les précisions à spécifier dans les normes de produit relatives aux enveloppes qui
s’appliquent.
61000-5-7 IEC:2001 – 9 –
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 5-7: Installation and mitigation guidelines –
Degrees of protection provided by enclosures against
electromagnetic disturbances (EM code)
1 Scope
This part of IEC 61000 describes performance requirements, test methods and classification
procedures for degrees of protection provided by empty enclosures against electromagnetic
disturbances for frequencies between 10 kHz and 40 GHz. The shielding performance is to be
measured prior to the installation of internal electrical and/or electronic equipment and
components. This shielding protection is measured for the purpose of demonstrating that the
enclosure provides adequate shielding of electromagnetic energy to support acceptable
performance of the complete assembled units when tested to applicable IEC standards.
However, it should be noted that satisfactory performance of an empty enclosure does not
necessarily ensure that the completed units will pass all EMC performance test standards for
the operating equipment (see discussion in annex A).
The purpose of this standard is to provide a repeatable means for evaluating the
electromagnetic shielding performance of empty mechanical enclosures, including cabinets and
subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a
known capability for attenuating electromagnetic fields. The requirements for immunity to
various types of electromagnetic disturbances, including lightning and high-altitude electro-
magnetic pulse (HEMP) will need to be considered by manufacturers when determining the
need for application of this standard for specific equipment and applications, and for the
specific enclosure shielding requirements which are necessary as a function of frequency.
The adoption of the classification system in this standard will, whenever possible, promote
uniformity in methods of describing the protection against electromagnetic stresses provided by
the enclosure. This includes protection of equipment inside the enclosure from external
electromagnetic stresses, as well as protection of external equipment from internally generated
electromagnetic stresses.
Technical Committees responsible for enclosures may decide on the extent and manner in
which the classification defined in this standard is used in their standards and to define
“enclosure” as it applies to their equipment. However, the tests and performance categories
must not differ from those specified in this standard. An informative guide for the details to be
specified in relevant enclosure product standards is given in annex B.
– 10 – 61000-5-7 CEI:2001
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente partie de la CEI 61000.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications ne
s’appliquent pas. Toutefois, les parties prenantes aux accords fondés sur la présente partie de
la CEI 61000 sont invitées à rechercher la possibilité d’appliquer les éditions les plus récentes
des normes indiquées ci-après. Pour les références non datées, la dernière édition
du document normatif en référence s’applique. Les membres de la CEI et de l’ISO possèdent
le registre des Normes internationales en vigueur.
CEI 60050(161): Vocabulaire Electrotechnique International – Chapitre 161: Compatibilité électro-
magnétique
CEI 60050(826): Vocabulaire Electrotechnique International – Chapitre 826: Installations
électriques des bâtiments
CEI 60068-1: Essais d'environnement – Partie 1: Généralités et guide
CEI 60529: Degrés de protection procurés par les enveloppes (Code IP)
CEI 61000-4-3: Compatibilité électromagnétique (CEM) – Partie 4: Techniques d’essai et de
mesure – Section 3: Essai d'immunité aux champs électromagnétiques rayonnés aux
fréquences radioélectriques
CEI 61000-4-23: Compatibilité électromagnétique (CEM) – Partie 4-23: Techniques d’essai et
de mesure – Méthodes d'essai pour les dispositifs de protection pour perturbations IEHM-HA et
autres perturbations rayonnées
3 Généralités
D'autres normes CEI définissent des prescriptions pour la construction et les essais d'immunité
des équipements électriques et électroniques qui doivent résister aux contraintes dues aux
perturbations électromagnétiques, y compris les transitoires électriques rapides et les
décharges électrostatiques. De plus, il existe des prescriptions similaires pour les essais pour
vérifier l'immunité aux impulsions électromagnétiques à haute altitude (IEM-HA). Il existe aussi
d’autres normes pour les enveloppes, concernant d’autres effets, en premier lieu la CEI 60529.
Cependant, les constructeurs de cet équipement électrique et électronique ont besoin soit de
construire soit de se procurer des enveloppes pour cet équipement avant de procéder aux
essais d'immunité aux perturbations électromagnétiques prévus à l’alinéa précédent. Avec
l'expérience, le constructeur sera capable de déterminer les niveaux spécifiques d'efficacité du
blindage électromagnétique qui sont suffisants pour permettre à leur produit fini de subir avec
succès les essais d'immunité et d'émission CEM requis.
L'efficacité de blindage (SE) est un terme large qui décrit la capacité d'un blindage EM à
réduire ou atténuer les champs électromagnétiques externes (ou produits à l'intérieur) et les
courants de surface externes (ou internes) avant qu'ils n'atteignent l'intérieur (l'extérieur) du
blindage. Normalement, le blindage enveloppe des équipements électroniques sensibles qu'il
faut protéger des perturbations électromagnétiques extérieures. Cependant, les blindages sont
également utilisés pour réduire les champs électromagnétiques produits par l'équipement placé
à l’intérieur et les empêcher de se propager à l'extérieur du blindage. La protection EM
est fournie par une topologie complète qui comprend non seulement un boîtier métallique
entourant le volume blindé mais également des traitements appropriés pour les pénétrations
électriques (alimentation électrique, communication, antenne, signal, alarmes, etc.) et
61000-5-7 IEC:2001 – 11 –
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this part of IEC 61000. For dated references, subsequent amendments
to, or revisions of, any of these publications do not apply. However, parties to agreements
based on this part of IEC 61000 are encouraged to investigate the possibility of applying the
most recent editions of the normative documents indicated below. For undated references, the
latest edition of the normative document referred to applies. Members of ISO and IEC maintain
registers of currently valid International Standards.
IEC 60050(161): International Electrotechnical Vocabulary (IEV) – Chapter 161: Electro-
magnetic compatibility
IEC 60050(826): International Electrotechnical Vocabulary (IEV) – Chapter 826: Electrical
installations of buildings
IEC 60068-1: Environmental testing – Part 1: General and guidance
IEC 60529: Degrees of protection provided by enclosures (IP Code)
IEC 61000-4-3: Electromagnetic compatibility (EMC) – Part 4: Testing and measurement
techniques – Section 3: Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-23: Electromagnetic compatibility (EMC) – Part 4-23: Testing and measurement
techniques – Test methods for protective devices for HEMP and other radiated disturbances
3 General
Other standards in the IEC series define requirements for construction and immunity testing of
electrical and electronic equipment which shall withstand the stresses produced by
electromagnetic disturbances, including fast electrical transients and electrostatic discharge
(ESD). In addition, there are similar requirements for testing to verify immunity to high-altitude
electromagnetic pulses (HEMP). There are also existing standards for these enclosures for
other effects, primarily IEC 60529.
However, manufacturers of this electrical and electronic equipment need to either construct or
procure enclosures for this equipment prior to the electromagnetic disturbance immunity testing
noted in the previous paragraph. With experience the manufacturers will be able to determine
the particular levels of electromagnetic shielding effectiveness which are sufficient to permit
their finished product to pass the required EMC immunity and emissions tests.
Shielding Effectiveness (SE) is a broad term describing the ability of an EM shield to reduce or
attenuate external (or internally produced) electromagnetic fields and external (or internal)
surface currents before they reach the interior (exterior) of the shield. Typically, the shield
encloses sensitive electronic equipment that must be protected from exterior electromagnetic
disturbances. However, shields are also used to reduce electromagnetic fields produced by
interior equipment from reaching the exterior of the shield. EM protection is provided by a
complete topology, consisting not only of a metallic shell surrounding the shielded volume, but
also including proper treatments of required electrical (power, communication, antenna, signal,
– 12 – 61000-5-7 CEI:2001
mécaniques (portes, clapets, tuyaux, etc.) requises. Les essais concernant les dispositifs de
protection non linéaires d'extrémité pour les pénétrations électriques ne font pas partie du
domaine d'application de la présente norme et sont traités dans d'autres normes CEI. Il est
recommandé que les constructeurs d'équipement coordonnent la protection procurée par les
blindages électromagnétiques et les dispositifs de protection des pénétrations de ligne tels que
les filtres et les éléments non linéaires, de façon à offrir des niveaux de protection compa-
rables contre les champs électromagnétiques rayonnés et contre les transitoires conduites.
L'efficacité de blindage de l'enveloppe est définie comme le rapport de la puissance reçue avec
et sans système de blindage inséré entre une antenne de réception et une antenne d'émission.
L'efficacité de blindage en un point donné nécessite donc un balayage d'étalonnage (sans
barrière) et un balayage de mesure (avec barrière) et elle est obtenue sous la forme du rapport
de puissance (différence en dB) entre ces deux résultats séparés. En supposant que c’est la
tension de l'antenne capteur qui est détectée,
V
c
SE = (1a)
V
m
V P
c c
SE (dB) = 20 log = 10 log (1b)
10 10
V P
m m
où
V est le signal mesuré, la barrière étant présente;
m
V est le signal d'étalonnage dans les mêmes conditions de puissance, fréquence,
c
polarisation et séparation d'antenne sans la barrière;
P et P sont les puissances qui correspondent à V et V aux entrées 50 Ω de l'analyseur de
c m c m
réseau.
De plus, pour chaque résultat d'efficacité de blindage, il faut donner une plage de mesure (MR)
qui donne la valeur plancher de bruit pour les mesures. La plage de mesure définit l'efficacité
de blindage maximale qui peut être mesurée avec précision. Pour les enveloppes
d'équipements vides, la plage de mesure est obtenue de la même manière que l'efficacité de
blindage à partir du même balayage d'étalonnage et d'un balayage de bruit complémentaire,
qui est une mesure avec l'énergie externe rayonnée par l'équipement de diagnostic de
l'efficacité de blindage mais avec le câble vers l'antenne de réception terminé sur 50 Ω (au
même emplacement que l'antenne), toutes les autres conditions étant les mêmes. Les
résultats de l'efficacité de blindage de la barrière sont obtenus en combinant les données de la
manière décrite à l'article 7.
Il est prouvé que dans beaucoup de cas, une enveloppe présentera une efficacité de blindage
supérieure après l'installation des composants et des modules par rapport à son efficacité à
vide. Dans d'autres cas, une enveloppe présentera une faible efficacité de blindage après
l'installation de pénétrations complémentaires. Il convient que les constructeurs examinent ces
impacts potentiels pour chaque application particulière.
4 Définitions
Pour les besoins de la présente partie de la CEI 61000, les définitions suivantes s'appliquent:
4.1
décibel (dB)
dixième du Bel, le nombre de décibels indique le rapport de deux puissances et il est égal à 10
fois le logarithme décimal de leur rapport. P et P désignant deux puissances et n le nombre
1 2
de décibels correspondant à leur rapport,
61000-5-7 IEC:2001 – 13 –
alarms, etc.) and mechanical penetrations (doors, vents, pipes, etc.). Testing of non-linear
terminal protection devices for electrical penetrations is beyond the scope of this standard and
is addressed in other IEC standards. Equipment manufacturers should coordinate the
protection provided by electromagnetic shields and line penetration protection devices such as
filters and non-linear elements to afford comparable levels of protection against both radiating
electromagnetic fields and conducted transients.
Enclosure shielding effectiveness is defined as the ratio of received power with and without an
intervening shield system inserted between a receiving and a transmitting antenna. The
shielding effectiveness at a given point thus requires a calibration sweep (no barrier) and a
measurement sweep (with barrier), and is obtained as the power ratio (difference in dB)
between these two separate results. Assuming that sensor antenna voltage is detected, then,
V
c
SE = (1a)
V
m
V P
c c
SE (dB) = 20 log = 10 log (1b)
10 10
V P
m m
where
V is the measured signal with the barrier present;
m
V is the calibration signal at the same power, frequency, antenna polarisation and
c
separation without the barrier;
P and P are the powers corresponding to V and V at the 50 Ω inputs of the network
c m c m
analyser.
In addition, for each shielding effectiveness result, a measurement range (MR) must be given
which quantifies the noise floor for the measurements. The measurement range defines the
maximum shielding effectiveness that can be accurately measured. For empty equipment
enclosures, the measurement range is obtained in the same manner as the shielding
effectiveness from the same calibration sweep and an additional noise sweep, which is a
measurement with the external energy radiated by the shielding effectiveness diagnostic
equipment but with the cable to the receive antenna terminated in 50 Ω (at the same location
as the antenna), and all other conditions remaining constant. Barrier shielding effectiveness
results are obtained by combining the data in a manner described in clause 7.
There is evidence that for many cases an enclosure will exhibit a higher shielding effectiveness
after installation of components and modules than does the empty enclosure. In other cases an
enclosure will exhibit a low shielding effectiveness after installing additional penetrations.
Manufacturers should consider these potential impacts for each particular application.
4 Definitions
For the purpose of this part of IEC 61000, the following definitions apply:
4.1
decibel (dB)
one tenth of a bel, the number of decibels denoting the ratio of two amounts of power being 10
times the logarithm to the base 10 of this ratio. With P and P designating two amounts of
1 2
power and n the number of decibels denoting their ratio,
– 14 – 61000-5-7 CEI:2001
P
n = 10 log (dB) (2)
P
Lorsque les conditions sont telles que les rapports des courants ou les rapports des tensions
(ou des grandeurs analogues dans d'autres domaines) sont les racines carrées des rapports
des puissances correspondantes, le nombre de décibels équivalent à la différence entre les
puissances correspondantes est exprimé par les relations suivantes:
I
n = 20 log (dB) (3)
I
V
n = 20 log (dB) (4)
V
où I /I et V /V représentent respectivement les rapports des courants et des tensions donnés.
1 2 1 2
Par extension, ces relations entre le nombre de décibels et les rapports des courants et des
tensions sont parfois appliquées lorsque ces rapports ne sont pas les racines carrées des
rapports des puissances correspondantes; pour éviter toute confusion, un tel usage doit être
accompagné d'une indication spécifique de cette application.
4.2
degré de protection
importance de la protection procurée par une enveloppe vide contre le passage de l'énergie
électromagnétique de l'extérieur vers l'intérieur ou de l'intérieur vers l'extérieur
4.3
compatibilité électromagnétique (CEM)
aptitude d'un appareil ou d'un système à fonctionner dans son environnement
électromagnétique de façon satisfaisante et sans produire lui-même des perturbations
électromagnétiques intolérables pour tout ce qui se trouve dans cet environnement
[VEI 161-01-07]
4.4
perturbation électromagnétique
tout phénomène électromagnétique susceptible de créer des troubles de fonctionnement d'un
dispositif, d'un appareil ou d'un système
[VEI 161-01-05, modifié]
4.5
brouillage électromagnétique
trouble apporté au fonct
...








Questions, Comments and Discussion