IEC 60836:1988
(Main)Specifications for silicone liquids for electrical purposes
Specifications for silicone liquids for electrical purposes
Covers silicone liquids to be used as insulating liquids in transformers and other electrical equipment.
Spécifications pour liquides silicones pour usages électriques
Traite des liquides silicones destinés à être utilisés comme isolants liquides dans les transformateurs et autres matériels électriques.
General Information
Relations
Standards Content (Sample)
IEC Publication 836
Publication 836 de la CEI
(First edition - 1988)
(Première édition - 1988)
Spécifications pour liquides silicones Specifications for silicon liquids
for electrical purposes
pour usages électriques
C O R R I G E N D U M 1
Page 5, preface:
Page 4, préface:
In the list of publications quoted, instead of
Dans la liste des publications citées, au lieu
de
474 (1974) Test method for oxydation
stability of inhibited mineral
474 (1974) Méthode d’essai pour la
insulating oils.
stabilité à l’oxydation des
huiles minérales isolantes
...
This May Also Interest You
IEC 60422:2024 provides monitoring guidance and procedures that are required for the use and maintenance of mineral insulating oils and other hydrocarbon-based liquids in transformers and other electrical equipment, including strategic spares and tanks for holding spare parts and components.
This document is applicable to mineral insulating oils, originally supplied conforming to IEC 60296, in transformers, switchgear and other electrical apparatus where oil sampling is reasonably practicable, and where the normal operating conditions specified in the equipment specifications apply.
This document is also intended to assist the power equipment operator to evaluate the condition of the oil and maintain it in a serviceable condition. It also provides a common basis for the preparation of more specific and complete local codes of practice.
The document includes recommendations on tests and evaluation procedures, and outlines methods for reconditioning and reclaiming oil, and the decontamination of oil contaminated with PCBs.
NOTE The condition monitoring of electrical equipment, for example by analysis of dissolved gases, furanic compounds or other means, is outside the scope of this document.
- Standard140 pagesEnglish and French languagesale 15% off
IEC 60567:2023 deals with the techniques for sampling free gases from gas-collecting relays from power transformers. Three methods of sampling free gases are described. The techniques for sampling oil from oil-filled equipment such as power and instrument transformers, reactors, bushings, oil-filled cables and oil-filled tank-type capacitors are no longer covered by this document, but are instead described in IEC 60475:2022, 4.2. Before analysing the gases dissolved in oil, they are first extracted from the oil. Three basic methods are described, one using extraction by vacuum (Toepler and partial degassing), another by displacement of the dissolved gases by bubbling the carrier gas through the oil sample (stripping) and the last one by partition of gases between the oil sample and a small volume of the carrier gas (headspace). The gases are analysed quantitatively after extraction by gas chromatography; a method of analysis is described. Free gases from gas-collecting relays are analysed without preliminary treatment.
- Standard128 pagesEnglish languagesale 15% off
- Standard128 pagesEnglish and French languagesale 15% off
IEC 60867:2022 covers specifications and test methods for unused synthetic aromatic hydrocarbons intended for use as insulating liquid in cables and capacitors.
- Standard41 pagesEnglish and French languagesale 15% off
IEC 60599:2022 describes how the concentrations of dissolved gases or free gases can be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This document is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. This document can be applied, but only with caution, to other liquid-solid insulating systems. In any case, the indications obtained are given only as guidance with resulting action undertaken only with proper engineering judgment.
- Standard122 pagesEnglish languagesale 15% off
- Standard80 pagesEnglish and French languagesale 15% off
IEC 60475:2022 is applicable to the sampling procedure used for insulating liquids in delivery containers and in electrical equipment such as power and instrument transformers, reactors, bushings, oil-filled cables, oil-filled tank-type capacitors, switchgear and load tap changers (LTCs). This document applies to liquids the viscosity of which at the sampling temperature is less than 1 500 mm2/s (or cSt). It applies to mineral oils and non-mineral oils (such as synthetic esters, natural esters, vegetable oils or silicones).
- Standard90 pagesEnglish languagesale 15% off
- Standard60 pagesEnglish and French languagesale 15% off
IEC TR 63025:2021(E) specifies two test methods for methanol and ethanol determination in insulating liquids.
Methanol (MeOH) and ethanol (EtOH) are two light alcohols generated during the degradation process of cellulosic materials. They are soluble in insulating liquids so they can be regarded as ageing tracers whose concentrations in oil reflect the degradation of insulating cellulosic materials in liquid-impregnated transformers.
- Technical report26 pagesEnglish languagesale 15% off
IEC 62975:2021 provides procedures and guidelines that are intended for the use and maintenance of natural ester liquid in sealed transformers and other electrical equipment.
This document is applicable to natural esters, originally supplied conforming to IEC 62770 and other applicable standards (e.g. ASTM D6871) in transformers, switchgear and electrical apparatus where liquid sampling is practical and where the normal operating conditions specified in the equipment specifications apply.
At present, there is a limited amount of information available for electrical equipment other than transformers.
This document is also intended to assist the power equipment operator to evaluate the condition of the natural ester and maintain it in a serviceable condition. It also provides a common basis for the preparation of more specific and complete local codes of practice.
The document includes recommendations on tests and evaluation procedures and outlines methods for reconditioning and reclaiming the liquid, when necessary.
- Standard73 pagesEnglish and French languagesale 15% off
IEC 60296:2020 provides specifications and test methods for unused and recycled mineral insulating oils. It applies to mineral oil delivered according to the contractual agreement, intended for use in transformers, switchgear and similar electrical equipment in which oil is required for insulation and heat transfer. Both unused oil and recycled oil under the scope of this document have not been used in, nor been in contact with electrical equipment or other equipment not required for manufacture, storage or transport.
Unused oils are obtained by refining, modifying and/or blending of petroleum products and other hydrocarbons from virgin feedstock.
Recycled oils are produced from oils previously used as mineral insulating oils in electrical equipment that have been subjected to re-refining or reclaiming (regeneration) by processes employed offsite. Such oils will have originally been supplied in compliance with a recognized unused mineral insulating oil specification. This document does not differentiate between the methods used to recycle mineral insulating oil. Oils treated on-site (see IEC 60422) are not within the scope of this document.
Oils with and without additives are both within the scope of this document.
This document does not apply to mineral insulating oils used as impregnating medium in cables or capacitors.
This fifth edition cancels and replaces the fourth edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– This International Standard is applicable to specifications and test methods for unused and recycled mineral insulating oils in the delivered state.
– Within the transformer insulating oils, two groups, Type A and Type B, are defined, based on their performance.
– A new method for stray gassing under thermo-oxidative stress of mineral insulating oils, which has been tested in a joint round robin test (RRT) between CIGRE D1 and IEC technical committee 10, has been included.
- Standard82 pagesEnglish and French languagesale 15% off
IEC 63012:2019 defines requirements for the characterization of unused modified esters or blends of unused esters used as insulating liquids for electrotechnical applications. It does not cover liquids that contain any proportion of used liquids. The liquids covered by this document are intended mainly for transformer applications.
Unused modified/synthetized esters are derived from a natural or synthetic base, or are blends of both. This document covers a variety of ester liquids not covered by other standards specific to natural esters (IEC 62770) or synthetic esters (IEC 61099). As it addresses various categories of liquids, this document also covers a wide range of values for certain performance characteristics. An important property is viscosity, which can affect the design and cooling performance of electrical equipment. A categorization is defined based on the kinematic viscosity of the different liquids. The category of low viscosity ester liquids is established.
- Standard41 pagesEnglish and French languagesale 15% off
IEC 62961:2018 establishes the measurement of the interfacial tension between insulating liquid and water by means of the Du Noüy ring method close to equilibrium conditions. In order to obtain a value that provides a realistic expression of the real interfacial tension, a measurement after a surface age of approximately 180 s is recorded.
- Standard41 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.