General Information

Abstract

IEC 61169-38:2008 which is a sectional specification, provides information and rules for the preparation of detail specifications for series TMA r.f. connectors together with the pro forma blank detail specification. Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power. The connectors are usable up to a frequency of at least 6 GHz.

Status
Published
Publication Date
12-Nov-2008
Current Stage
PPUB - Publication issued
Start Date
13-Nov-2008
Completion Date
31-Dec-2008

Buy Documents

Standard

IEC 61169-38:2008 - Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 ? (type TMA) - 50 ? applications Released:11/13/2008

ISBN:978-2-88910-430-7
English language (27 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-38:2008 - Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 ? (type TMA) - 50 ? applications Released:11/13/2008

ISBN:978-2-8322-1351-3
English and French language (53 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 61169-38:2008 is a sectional specification in the IEC 61169 series covering radio-frequency coaxial connectors, model TMA (slide‑in, rack and panel applications). It establishes requirements and a pro forma detail specification for 50 Ω TMA connectors used with RF cables or microstrip in microwave systems. The standard addresses mechanical dimensions, gauging, performance recommendations and test/inspection procedures for connectors usable up to at least 6 GHz.

Key Topics

  • Connector definition and scope: Series TMA slide‑in connectors for blind‑entry, mid‑power applications in rack and panel assemblies.
  • Mating face dimensions: Prescribed dimensional tolerances for pin‑centre and socket‑centre mating faces (general connectors Grade 2 and standard test connectors Grade 0).
  • Gauging and measurement: Gauge designs and sizing procedures for outer and inner contacts, including specified gauge pins and retention tests.
  • Mechanical mounting: Guidance on connector mounting in modules and panels, including radial and axial misalignment allowances for rigid and float mounts.
  • Quality assessment & tests: Test schedules, inspection requirements and selected tests from QC 220000 (IEC 61169‑1) with acceptance and periodic test tables; assessment levels M and H are covered.
  • Detail specification pro forma: Instructions and a blank detail specification template to prepare product‑specific documents (identification, performance, marking, test selections, severities).
  • Reference materials: Figures and tables for dimensions, gauges and test connector constructions; normative references to IEC 61169‑1 and IEC QC registers.

Applications

IEC 61169-38 is intended for practical use where reliable RF interconnection is critical:

  • Telecommunications base stations and rack‑mounted RF equipment
  • Microwave test and measurement instrumentation
  • Broadcast and studio rack systems
  • Aerospace, defense and industrial RF modules employing mid‑power, blind‑entry coaxial connections
  • PCB/microstrip interfaces where a 50 Ω slide‑in connector is required (up to ~6 GHz)

Who should use this standard

  • RF connector manufacturers preparing detail specifications and product drawings
  • Design engineers specifying mechanical and electrical mating interfaces
  • Quality and test engineers implementing acceptance and periodic test regimes
  • Procurement and compliance teams requiring standardized product requirements
  • Test laboratories performing dimensional gauging and conformance testing

Related Standards (if applicable)

  • IEC 61169‑1: Generic specification - general requirements and measuring methods
  • Other parts of the IEC 61169 series for different connector types and impedances
  • IEC QC 220000 register and quality/conformance procedures

Keywords: IEC 61169-38, TMA connector, radio-frequency connectors, coaxial connectors, 50 Ω, slide‑in, rack and panel, 6 GHz, mating face dimensions, gauging, quality assessment.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61169-38:2008 - Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 ? (type TMA) - 50 ? applications Released:11/13/2008

ISBN:978-2-88910-430-7
English language (27 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-38:2008 - Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 ? (type TMA) - 50 ? applications Released:11/13/2008

ISBN:978-2-8322-1351-3
English and French language (53 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 61169-38:2008 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 Ω (type TMA) - 50 Ω applications". This standard covers: IEC 61169-38:2008 which is a sectional specification, provides information and rules for the preparation of detail specifications for series TMA r.f. connectors together with the pro forma blank detail specification. Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power. The connectors are usable up to a frequency of at least 6 GHz.

IEC 61169-38:2008 which is a sectional specification, provides information and rules for the preparation of detail specifications for series TMA r.f. connectors together with the pro forma blank detail specification. Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power. The connectors are usable up to a frequency of at least 6 GHz.

IEC 61169-38:2008 is classified under the following ICS (International Classification for Standards) categories: 33.120.20 - Wires and symmetrical cables. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61169-38:2008 has the following relationships with other standards: It is inter standard links to IEC PAS 61169-38:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61169-38:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61169-38
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,
slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type
TMA) – 50 Ω applications
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61169-38
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,
slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type
TMA) – 50 Ω applications
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.20 ISBN 978-2-88910-430-7
– 2 – 61169-38 © IEC:2008(E)
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Mating face and gauge information.7
3.1 Dimensions – General connectors – Grade 2.7
3.1.1 Connector with pin centre contact (see Figure 1) .7
3.1.2 Connectors with socket-centre contact (see Figure 2).8
3.2 Gauges .9
3.2.1 Connectors with pin-centre contact.9
3.2.2 Connectors with socket-centre contact .10
3.3 Dimensions – standard test connectors – Grade 0.11
3.3.1 Connector with pin-centre contact (see Figure 5).11
3.3.2 Connector with socket-centre contact (see Figure 6) .12
3.4 General requirements for connector mounting in modules and on panels.14
3.4.1 Radial misalignment .14
3.4.2 Axial misalignment .14
4 Quality assessment procedure.15
4.1 General .15
4.2 Rating and characteristics ( see Clause 6 of IEC 61169-1/QC220000) .15
4.3 Test schedule and inspection requirements .18
4.3.1 Acceptance tests (see Table 8).18
4.3.2 Periodic tests (see Table 9) .19
4.4 Procedures.20
4.4.1 Quality conformance inspection .20
4.4.2 Qualification approval and its maintenance.20
5 Instructions for preparation of detail specifications .20
5.1 General .20
5.2 Identification of the detail specification .21
5.3 Identification of the component.21
5.4 Performance.21
5.5 Marking, ordering information and related matters .21
5.6 Selection of tests, test conditions and severities.22
5.7 Blank detail specification pro-forma for type TMA connector.23

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1).7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) .8
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3) .9
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4).10
Figure 5 – Standard test connector with pin-centre contact (for dimensions, see Table 5).11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) .12
Figure 7 – The sketch map of connector radial misalignment .14
Figure 8 – The sketch map of rigidly mounted and float-mounted connector.14

Table 1 – Dimensions of connector with pin-centre contact .7

61169-38 © IEC:2008(E) – 3 –
Table 2 – Dimensions of connector with socket-centre contact.8
Table 3 – Dimensions of gauge for outer contact of pin connector .9
Table 4 – Dimensions of gauge pin for socket-center contact.10
Table 5 – Dimensions of standard test connector with pin-centre contact.11
Table 6 – Dimensions of standard test connector with socket-centre contact .13
Table 7 – Rating and characteristics .15
Table 8 – Acceptance tests.18
Table 9 – Periodic tests .19

– 4 – 61169-38 © IEC:2008(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-38 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This standard cancels and replaces IEC/PAS 61169-38 published in 2007.
The text of this standard is based on the following documents:
CDV Report on voting
46F/75/CDV 46F/90/RVC
61169-38 © IEC:2008(E) – 5 –
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

– 6 – 61169-38 © IEC:2008(E)
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
1 Scope
This part of 61169, which is a sectional specification, provides information and rules for the
preparation of detail specifications for series TMA r.f. connectors together with the pro forma
blank detail specification.
Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with
R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power.
The connectors are usable up to a frequency of at least 6 GHz.
This specification also prescribes mating face dimensions for general purpose connectors,
dimensional details of standard test connectors grade 0, gauging information and tests
selected from QC 220000 (IEC 61169-1), applicable to all detail specifications relating to
series TMA connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC QC 001005, Register of firms, products and services approved under the IECQ system,
including ISO 9000
61169-38 © IEC:2008(E) – 7 –
3 Mating face and gauge information
3.0 General
Metric dimensions are original dimensions.
All undimensioned pictorial configurations are for reference purposes only.
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin centre contact (see Figure 1)

g
Note 3
h
i
Note 2
1° ∼ 4°
55° ∼ 65°
Note 1
j
k
l
IEC  1789/08
Note 1
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)

Table 1 – Dimensions of connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,32 1,37 0,052 0,054 Diameter
c 2,06 2,21 0,081 0,087 Diameter
d 4,83 — 0,190 — Diameter
e — — — — 2/ Diameter
f 8,00 8,05 0,315 0,317 Diameter
g 8,60 — 0,339 —
h 0,08 1,02 0,003 0,040
i 0,15 — 0,006 —
j 1,96 3,05 0,078 —
k 5,33 5,84 0,210 0,230
l 5,28 5,79 0,208 0,228
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 MSlotted and flared to meet electrical and mechanical requirements.
NOTE 3 MDesign and location of the sealing feature is optional but ensures the environmental performance
requirements are met.
e
d
f
b
c
– 8 – 61169-38 © IEC:2008(E)
3.1.2 Connectors with socket-centre contact (see Figure 2)

v
w
x
35° ∼ 40°
Note 3
y
Note 2
aa
z
Note 1
IEC  1790/08
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
mm in
Ref. Notes
min. max. min. max.
o — — — — 2/ Diameter
p 2,06 2,21 0,081 0,087 Diameter
q — 4,72 — 0,186 Diameter
r — 6,50 — 0,256 3/ Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 4,78 5,28 0,188 0,208
w 4,72 5,23 0,186 0,206
x 4,95 — 0,195 —
y — 0,15 — 0,006
z 8,31 8,51 0,327 0,335
aa — — — — 4
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Slotted and closed to meet electrical and mechanical requirements.
NOTE 3 Applies only when dielectric extends beyond reference plane.
NOTE 4 Radius
o
p
q
r
s
t
u
61169-38 © IEC:2008(E) – 9 –
3.2 Gauges
3.2.1 Connectors with pin-centre contact
3.2.1.1 Gauge for outer contact of pin connector (see Figure 3)

z
35° ∼ 40°
(aa)
IEC  1791/08
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3)

Table 3 – Dimensions of gauge for outer contact of pin connector
Gauge B
(for measurement of gauge retention
Gauge A
force for outer conductor) Notes
(for sizing purposes)
Mass of gauge(weight): 225 g ± 5 g

mm in mm in
Ref.
min. max. min. max. min. max. min. max.
s 8,08 8,10 0,318 0,319 8,15 8,18 0,321 0,322 Diameter
t 10,00 10,15 0,394 0,400 10,00 10,15 0,394 0,400 Diameter
u 12,4 — 0,488 — 12,4 — 0,488 — Diameter
z 8,41 8,46 0,331 0,333 8,36 8,41 0,329 0,331 Diameter
aa 0,8 0,031 0,8 0,031 2/ Radius
NOTE 1 Material: steel, polished, surface roughness: Ra ≤ 0,4 µm (16 µin).
NOTE 2 Parentheses indicate the reference size for size.

3.2.1.2 Test sequence
Gauge A shall be placed over the outer electrical contact of the connector once. This is a
sizing operation and should only be carried out when the insulator is removed from the
connector.
After this, gauge B shall be placed over the outer contact in a vertical position. The gauge
shall be retained. This test can also be carried out on connectors when the insulator is not
removed.
u
s
t
– 10 – 61169-38 © IEC:2008(E)
3.2.2 Connectors with socket-centre contact
3.2.2.1 Gauge pin for socket-centre contact (see Figure 4)

4 mm max.
(0,157 in max.)
3,17 mm min.
(0,125 in min.)
IEC  1792/08
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4)
Table 4 – Dimensions of gauge pin for socket-center contact
Gauge D
Gauge C
(for measurement of gauge retention
Note
force for inner conductor)
(for sizing purpose)
Mass (weight) of gauge: 57 g ± 1 g

mm in mm in
Ref.
min. max. min. max. min. max. min. max.

b
1,372 1,377 0,054 0 0,0542 1,308 1,321 0,0515 0,052 0 Diameter
Material: steel, polished , surface roughness: Ra ≤ 0,4 µm (16 µin).

3.2.2.2 Test sequence
Test pin gauge C shall be inserted into the centre contact three times with a minimum
distance of 3,17 mm (0,125 in). This is a sizing operation and should only be carried out when
the socket-centre contact is removed from the connector.
After this, gauge D shall be inserted and held in the vertical position. The gauge shall be
retained. This test can also be carried out on connectors when the socket-centre contact is
not removed.
b
61169-38 © IEC:2008(E) – 11 –
3.3 Dimensions – standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact (see Figure 5)

∅0,01 mm
A
∅0,0005 in
∅0,1 mm
∅0,1 mm
A g
A
∅0,004 in
∅0,004 in
i
Note 3
Note 2
j
A
ab
∅0,05 mm
k
A
∅0,002 in
l
Note 4 Note 5
Note 1
B
ac
1° ∼ 3°
55° ∼ 65° ∅0,05 mm
A
∅0,002 in
Note 1
IEC  1793/08
Figure 5 – Standard test connector with pin-centre contact
(for dimensions, see Table 5)
Table 5 – Dimensions of standard test connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,35 1,37 0,053 0 0,054 1 Diameter
c 2,140 nom. 0,084 2 nom. 2/ Diameter
d 4,88 4,93 0,192 0,194 Diameter
f 8,06 8,09 0,317 5 0,318 5 3/ Diameter
g 8,60 — 0,339 —
i 0,15 0,30 0,006 0,012
j 3,66 3,98 0,144 0,157
k 5,31 5,38 0,209 0,212
l 5,38 5,54 0,212 0,218
m 6,99 7,01 0,275 2 0,276 0 2/ Diameter
n1 6,60 6,65 0,260 0,262 Diameter
n2 6,72 6,74 0,264 5 0,265 5 Diameter
ab 0,1 0,3 0,004 0,012 Radius
ac — 0,13      —     0,005 Radius
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polytetrafluorethylene (PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters m and c is 50 Ω ± 0,2 Ω.
NOTE 3 Before slotting. Six slots 60 º ± 1º apart, 0,36 mm to 0,41 mm( 0,014 in to 0,016 in) wide, 5,84 mm to
6,10 mm (0,230 in to 0,240 in) deep. After slotting and flaring, the inner diameter of outer contact should be
6,718 mm to 6,744 mm (0,264 5 in to 0,265 5 in) when inserted into ring gauge with inner diameter 8,125 mm to
8,131 mm ( 0,3199 in to 0,320,1 in).
NOTE 4 If concentric, 0,05 mm (0,002 in) nominal radial air gap when inserted into ring gauge with inner diameter
8,125 mm to 8,131 mm (0,319 9 in to 0,320 1 in).
NOTE 5 Zero air gap.
f
n2
n1
d
a
b c
c
m
– 12 – 61169-38 © IEC:2008(E)
3.3.2 Connector with socket-centre contact (see Figure 6)

∅0,01 mm
C
v
∅0,0005 in
w
Note 2
bd
35° ∼ 40°
Note 4
C
∅0,1 mm
C
∅0,004 in
∅0,08 mm
y C
∅0,003 in
Note 4
Note 5 be ∅0,08 mm
Note 6 C
∅0,003 in
z
(aa)
Note 1
bj
Note 3
bk
D
60° ± 30′
Note 3
bm
∅0,05 mm
D
bn
∅0,002 in
x
IEC  1794/08
Figure 6 – Standard test connector with socket-centre contact
(for dimensions, see Table 6)
bc
bb
p
p
o
bf q
bh
r
s
t
u
61169-38 © IEC:2008(E) – 13 –
Table 6 – Dimensions of standard test connector with socket-centre contact

mm in
Ref. Notes
min max min max
o 1,52 1,63 0,060 0,064 Diameter
p 2,140 nom 0,084 2 nom 2/ Diameter
q 4,67 4,72 0,184 0,186 Diameter
r 6,58 6,68 0,259 0,263 Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 5,08 5,23 0,200 0,206
w 5,21 5,28 0,205 0,208
x 5,21 — 0,205 —
y 0,0 0,15 0,00 0,006 6
z 8,36 8,46 0,329 0,333
aa 0,8 0,031 7/ Diameter
bb 6,71 6,76 0,264 0,266 Diameter
bc 6,99 7,01 0,275 2 0,276 0 2/ Diameter
bd — 0,1 — 0,004 Radius
be 0,79 0,84 0,031 0,033
bf 1,356 1,361 0,053 4 0,053 6 3/ Diameter
bh 2,16 2,18 0,084 9 0,085 9 3/ Diameter
bj 6,05 6,10 0,238 0,240
bk 4,62 4,88 0,182 0,192
bm 0,05 0,2 0,002 0,008
bn 0,38 0,89 0,015 0,035
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polyterafluorethylene(PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters p and bc is 50 Ω ± 0,2 Ω
...


IEC 61169-38 ®
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,
slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type
TMA) – 50 Ω applications
Connecteurs pour fréquences radioélectriques –
Partie 38: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences
radioélectriques, de type glissant (applications en panneau et fond de panier) –
Impédance caractéristique 50 Ω (type TMA) – Applications à 50 Ω

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,

77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
14 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
Plus de 55 000 entrées terminologiques électrotechniques, en
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des

CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 61169-38 ®
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,

slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type

TMA) – 50 Ω applications
Connecteurs pour fréquences radioélectriques –

Partie 38: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences

radioélectriques, de type glissant (applications en panneau et fond de panier) –

Impédance caractéristique 50 Ω (type TMA) – Applications à 50 Ω

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.20 ISBN 978-2-8322-1351-3

– 2 – 61169-38  IEC:2008
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 7
3.1 Dimensions – General connectors – Grade 2 . 7
3.1.1 Connector with pin centre contact (see Figure 1) . 7
3.1.2 Connectors with socket-centre contact (see Figure 2) . 8
3.2 Gauges . 9
3.2.1 Connectors with pin-centre contact . 9
3.2.2 Connectors with socket-centre contact . 10
3.3 Dimensions – standard test connectors – Grade 0 . 11
3.3.1 Connector with pin-centre contact (see Figure 5) . 11
3.3.2 Connector with socket-centre contact (see Figure 6) . 12
3.4 General requirements for connector mounting in modules and on panels. 14
3.4.1 Radial misalignment . 14
3.4.2 Axial misalignment . 14
4 Quality assessment procedure . 15
4.1 General . 15
4.2 Rating and characteristics ( see Clause 6 of IEC 61169-1/QC220000) . 15
4.3 Test schedule and inspection requirements . 18
4.3.1 Acceptance tests (see Table 8). 18
4.3.2 Periodic tests (see Table 9) . 19
4.4 Procedures . 20
4.4.1 Quality conformance inspection . 20
4.4.2 Qualification approval and its maintenance . 20
5 Instructions for preparation of detail specifications . 20
5.1 General . 20
5.2 Identification of the detail specification . 21
5.3 Identification of the component . 21
5.4 Performance . 21
5.5 Marking, ordering information and related matters . 21
5.6 Selection of tests, test conditions and severities . 22
5.7 Blank detail specification pro-forma for type TMA connector . 23

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) . 8
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3) . 9
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4). 10
Figure 5 – Standard test connector with pin-centre contact (for dimensions, see Table 5) . 11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) . 12
Figure 7 – The sketch map of connector radial misalignment . 14
Figure 8 – The sketch map of rigidly mounted and float-mounted connector . 14

Table 1 – Dimensions of connector with pin-centre contact . 7

61169-38  IEC:2008 – 3 –
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge for outer contact of pin connector . 9
Table 4 – Dimensions of gauge pin for socket-center contact . 10
Table 5 – Dimensions of standard test connector with pin-centre contact . 11
Table 6 – Dimensions of standard test connector with socket-centre contact . 13
Table 7 – Rating and characteristics . 15
Table 8 – Acceptance tests . 18
Table 9 – Periodic tests . 19

– 4 – 61169-38  IEC:2008
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-38 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This bilingual version (2014-01) corresponds to the monolingual English version, published in
2008-11.
This standard cancels and replaces IEC/PAS 61169-38 published in 2007.

61169-38  IEC:2008 – 5 –
The text of this standard is based on the following documents:
CDV Report on voting
46F/75/CDV 46F/90/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
The French version of this standard has not been voted upon.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – 61169-38  IEC:2008
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
1 Scope
This part of 61169, which is a sectional specification, provides information and rules for the
preparation of detail specifications for series TMA r.f. connectors together with the pro forma
blank detail specification.
Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with
R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power.
The connectors are usable up to a frequency of at least 6 GHz.
This specification also prescribes mating face dimensions for general purpose connectors,
dimensional details of standard test connectors grade 0, gauging information and tests
selected from QC 220000 (IEC 61169-1), applicable to all detail specifications relating to
series TMA connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC QC 001005, Register of firms, products and services approved under the IECQ system,
including ISO 9000
61169-38  IEC:2008 – 7 –
3 Mating face and gauge information
3.0 General
Metric dimensions are original dimensions.
All undimensioned pictorial configurations are for reference purposes only.
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin centre contact (see Figure 1)

g
Note 3
h
i
Note 2
1° ∼ 4°
55° ∼ 65°
Note 1
j
k
l
IEC  1789/08
Note 1
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)

Table 1 – Dimensions of connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,32 1,37 0,052 0,054 Diameter
c 2,06 2,21 0,081 0,087 Diameter
d 4,83 — 0,190 — Diameter
e — — — — 2/ Diameter
f 8,00 8,05 0,315 0,317 Diameter
g 8,60 — 0,339 —
h 0,08 1,02 0,003 0,040
i 0,15 — 0,006 —
j 1,96 3,05 0,078 —
k 5,33 5,84 0,210 0,230
l 5,28 5,79 0,208 0,228
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Slotted and flared to meet electrical and mechanical requirements.
NOTE 3 Design and location of the sealing feature is optional but ensures the environmental performance
requirements are met.
e
d
f
b
c
– 8 – 61169-38  IEC:2008
3.1.2 Connectors with socket-centre contact (see Figure 2)

v
w
x
35° ∼ 40°
Note 3
y
Note 2
aa
z
Note 1
IEC  1790/08
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
mm in
Ref. Notes
min. max. min. max.
o — — — — 2/ Diameter
p 2,06 2,21 0,081 0,087 Diameter
q — 4,72 — 0,186 Diameter
r — 6,50 — 0,256 3/ Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 4,78 5,28 0,188 0,208
w 4,72 5,23 0,186 0,206
x 4,95 — 0,195 —
y — 0,15 — 0,006
z 8,31 8,51 0,327 0,335
aa — — — — 4
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Slotted and closed to meet electrical and mechanical requirements.
NOTE 3 Applies only when dielectric extends beyond reference plane.
NOTE 4 Radius
o
p
q
r
s
t
u
61169-38  IEC:2008 – 9 –
3.2 Gauges
3.2.1 Connectors with pin-centre contact
3.2.1.1 Gauge for outer contact of pin connector (see Figure 3)

z
35° ∼ 40°
(aa)
IEC  1791/08
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3)

Table 3 – Dimensions of gauge for outer contact of pin connector
Gauge B
(for measurement of gauge retention
Gauge A
force for outer conductor) Notes
(for sizing purposes)
Mass of gauge(weight): 225 g ± 5 g

mm in mm in
Ref.
min. max. min. max. min. max. min. max.
s 8,08 8,10 0,318 0,319 8,15 8,18 0,321 0,322 Diameter
t 10,00 10,15 0,394 0,400 10,00 10,15 0,394 0,400 Diameter
u 12,4 — 0,488 — 12,4 — 0,488 — Diameter
z 8,41 8,46 0,331 0,333 8,36 8,41 0,329 0,331 Diameter
aa 0,8 0,031 0,8 0,031 2/ Radius
NOTE 1 Material: steel, polished, surface roughness: Ra ≤ 0,4 µm (16 µin).
NOTE 2 Parentheses indicate the reference size for size.

3.2.1.2 Test sequence
Gauge A shall be placed over the outer electrical contact of the connector once. This is a
sizing operation and should only be carried out when the insulator is removed from the
connector.
After this, gauge B shall be placed over the outer contact in a vertical position. The gauge
shall be retained. This test can also be carried out on connectors when the insulator is not
removed.
u
s
t
– 10 – 61169-38  IEC:2008
3.2.2 Connectors with socket-centre contact
3.2.2.1 Gauge pin for socket-centre contact (see Figure 4)

4 mm max.
(0,157 in max.)
3,17 mm min.
(0,125 in min.)
IEC  1792/08
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4)
Table 4 – Dimensions of gauge pin for socket-center contact
Gauge D
Gauge C
(for measurement of gauge retention
Note
force for inner conductor)
(for sizing purpose)
Mass (weight) of gauge: 57 g ± 1 g

mm in mm in
Ref.
min. max. min. max. min. max. min. max.

b
1,372 1,377 0,054 0 0,0542 1,308 1,321 0,0515 0,052 0 Diameter
Material: steel, polished , surface roughness: Ra ≤ 0,4 µm (16 µin).

3.2.2.2 Test sequence
Test pin gauge C shall be inserted into the centre contact three times with a minimum
distance of 3,17 mm (0,125 in). This is a sizing operation and should only be carried out when
the socket-centre contact is removed from the connector.
After this, gauge D shall be inserted and held in the vertical position. The gauge shall be
retained. This test can also be carried out on connectors when the socket-centre contact is
not removed.
b
61169-38  IEC:2008 – 11 –
3.3 Dimensions – standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact (see Figure 5)

∅0,01 mm
A
∅0,0005 in
∅0,1 mm
∅0,1 mm
A g
A
∅0,004 in
∅0,004 in
i
Note 3
Note 2
j
A
ab
∅0,05 mm
k
A
∅0,002 in
l
Note 4 Note 5
Note 1
B
ac
1° ∼ 3°
55° ∼ 65° ∅0,05 mm
A
∅0,002 in
Note 1
IEC  1793/08
Figure 5 – Standard test connector with pin-centre contact
(for dimensions, see Table 5)
Table 5 – Dimensions of standard test connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,35 1,37 0,053 0 0,054 1 Diameter
c 2,140 nom. 0,084 2 nom. 2/ Diameter
d 4,88 4,93 0,192 0,194 Diameter
f 8,06 8,09 0,317 5 0,318 5 3/ Diameter
g 8,60 — 0,339 —
i 0,15 0,30 0,006 0,012
j 3,66 3,98 0,144 0,157
k 5,31 5,38 0,209 0,212
l 5,38 5,54 0,212 0,218
m 6,99 7,01 0,275 2 0,276 0 2/ Diameter
n1 6,60 6,65 0,260 0,262 Diameter
n2 6,72 6,74 0,264 5 0,265 5 Diameter
ab 0,1 0,3 0,004 0,012 Radius
ac — 0,13      —     0,005 Radius
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polytetrafluorethylene (PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters m and c is 50 Ω ± 0,2 Ω.
NOTE 3 Before slotting. Six slots 60 º ± 1º apart, 0,36 mm to 0,41 mm (,0140 in to 0,016 in ),84wid me,m 5 to
6,10 mm (0,230 in to 0,240 in) deep. After slotting and flaring, the inner diameter of outer contact should be
6,718 mm to 6,744 mm (0,264 5 in to 0,265 5 in) when inserted into ring gauge with inner diameter 8,125 mm to
8,131 mm ( 0,3199 in to 0,320,1 in).
NOTE 4 If concentric, 0,05 mm (0,002 in) nominal radial air gap when inserted into ring gauge with inner diameter
8,125 mm to 8,131 mm (0,319 9 in to 0,320 1 in).
NOTE 5 Zero air gap.
f
n2
n1
d
a
b c
c
m
– 12 – 61169-38  IEC:2008
3.3.2 Connector with socket-centre contact (see Figure 6)

∅0,01 mm
C
v
∅0,0005 in
w
Note 2
bd
35° ∼ 40°
Note 4
C
∅0,1 mm
C
∅0,004 in
∅0,08 mm
y
C
∅0,003 in
Note 4
be ∅0,08 mm
Note 5
Note 6
C
∅0,003 in
z
(aa)
Note 1
bj
Note 3
D bk
60° ± 30′
Note 3
bm
∅0,05 mm
D
bn
∅0,002 in
x
IEC  1794/08
Figure 6 – Standard test connector with socket-centre contact
(for dimensions, see Table 6)
bc
bb
p
p
o
bf q
bh
r
s
t
u
61169-38  IEC:2008 – 13 –
Table 6 – Dimensions of standard test connector with socket-centre contact

mm in
Ref. Notes
min max min max
o 1,52 1,63 0,060 0,064 Diameter
p 2,140 nom 0,084 2 nom 2/ Diameter
q 4,67 4,72 0,184 0,186 Diameter
r 6,58 6,68 0,259 0,263 Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 5,08 5,23 0,200 0,206
w 5,21 5,28 0,205 0,208
x 5,21 — 0,205 —
y 0,0 0,15 0,00 0,006 6
z 8,36 8,46 0,329 0,333
aa 0,8 0,031 7/ Diameter
bb 6,71 6,76 0,264 0,266 Diameter
bc 6,99 7,01 0,275 2 0,276 0 2/ Diameter
bd — 0,1 — 0,004 Radius
be 0,79 0,84 0,031 0,033
bf 1,356 1,361 0,053 4 0,053 6 3/ Diameter
bh 2,16 2,18 0,084 9 0,085 9 3/ Diameter
bj 6,05 6,10 0,238 0,240
bk 4,62 4,88 0,182 0,192
bm 0,05 0,2 0,002 0,008
bn 0,38 0,89 0,015 0,035
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polyterafluorethylene(PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters p and bc is 50 Ω ± 0,2 Ω.
NOTE 3 Four slots 0,18 mm to 0,23 mm (0,007 in to 0,009 in ) wide ; 90°30' to 89°30' apart. Diameter y with
1,356 mm (0,0534 in) min: 1,361 mm (0,0536 in) max. pin gauge inserted after slotting and closing.
NOTE 4 If concentric 0,02 mm (0,0008 in) radial air gap when mated with 1,359 mm (0,053 5 in) diameter pin.
NOTE 5 Zero air gap.
NOTE 6 Insulator is flush or protruding.
NOTE 7 Parentheses indicate the reference size for size.

– 14 – 61169-38  IEC:2008
3.4 General requirements for connector mounting in modules and on panels
3.4.1 Radial misalignment
The radial misalignment between engaging connectors refers to the coaxiality error A
(see Figure 7) between a connector with socket-centre contact and a connector with pin
centre contact at the beginning and during the engagement.
At the beginning of the engagement, the radial misalignment of rigidly mounted connector and
float-mounted connector shall no more than 0,51 mm.

IEC  1795/08
Figure 7 – The sketch map of connector radial misalignment
3.4.2 Axial misalignment
For rigidly mounted connector and float-mounted connector, the float mounting allows a total
of 1,52 mm (0,060 in) axial travel. The mounting arrangements should, however, ensure a
minimum length of travel of 0,26 mm (0,010 in) [0,76 mm (0,030 in) preferred ] to ensure that
full length of engagement is maintained under operational conditions (see Figure 8).

0,25 mm min.
(1,52 mm axial travel)
Mechanical and electrical reference plane
Spring mechanism
IEC  1796/08
Figure 8 – The sketch map of rigidly mounted and float-mounted connector

A
61169-38  IEC:2008 – 15 –
4 Quality assessment procedure
4.1 General
The following clauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the proforma
blank detail specification (BDS) and instructions for the preparation of a detail specification.
4.2 Rating and characteristics ( see Clause 6 of IEC 61169-1/QC220000)
The values indicated in Table 7 are recommended for series TMA connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.

Table 7 – Rating and characteristics
Test method
Remarks, deviations
IEC 61169-1
Ratings and characteristics Value from standard test
(QC 220000)
method
subclause
Electrical
Nominal impedance  50 Ω
Frequency range
Grade 2 connectors Up to 6 GHz Or upper frequency
limit of cable
a
Reflection factor 9.2.1
Grade 2 connectors
– straight styles ≤0,13
– right-angle styles ≤0,15
– component mounting styles
See detail
specification
– solder bucket and PCB mounting styles
b
Center contact resistance 9.2.3
– initial
≤ 1,5 mΩ
– change due to conditioning ≤ 2 mΩ
b
Outer conductor continuity 9.2.3
– initial
≤ 2 mΩ
– after conditioning
≤ 3 mΩ
– 16 – 61169-38  IEC:2008
Table 7 (continued)
Test method
Remarks, deviations
IEC 61169-1
Ratings and characteristics Value from standard test
(QC 220000)
method
subclause
Mechanical
Center contact captivation 9.3.5
– axial force
15 N Maximum
displacement
0,25 mm in each
direction
– torque
na
Engagement and separation 9.3.6
– engagement force
≤ 20 N
– separation force
≥ 2,25 N
Gauge retention force (resilient contacts) 9.3.4
– center
≥ 0,57 N
– outer
≥ 2,25 N
Technical tests on cable fixing
– cable rotation ( nutation )
9.3.7.2
– cable pulling
See detail
9.3.8
specification
– cable bending
9.3.9
– cable torsion
9.3.10
Tensile strength of coupling mechanism
9.3.11 na
Bending moment
9.3.12 na
Vibration
9.3.3 2 Acceleration: 15 gn
150 m/s
10 Hz – 2 000 Hz
Shock
9.3.14  2 Acceleration: 75 gn
750 m/s 11 ms
saw tooth
b
Insulation resistance 9.2.5
–  initial
≥ 5 GΩ
– after conditioning
≥200 MΩ
cd
proof voltage at sea-level 9.2.6
– cables 96IEC 50-4
1 000 V
– cables 96IEC 50-3
1 000 V
– cables 96IEC 50-2
750 V
cd
proof voltage at 4,4 kPa  4,4 kPa
approximately
– cables 96IEC 50-4
180 V
equivalent to 20 km
– cables 96IEC 50-3 (70 000 ft) altitude
180 V
– cables 96IEC 50-2
150 V
61169-38  IEC:2008 – 17 –
Table 7 (continued)
Ratings and characteristics Test method Value Remarks, deviations
IEC 61169-1 from standard test
(QC 220000) method
subclause
cd
Environmental test voltage at sea-level
– cables 96IEC 50-4
400 V
– cables 96IEC 50-3
400 V
– cables 96IEC 50-2
350 V
cd
Environmental test voltage at 4,4 kPa 4,4 kPa
approximately
equivalent to 20 km
(70 000 ft) altitude
– cables 96IEC 50-4 90 V
– cables 96IEC 50-2 90 V
– cables 96IEC 50-3 85 V
f
60 dB, 3 GHz Z t ≤ 100 mΩ
Screening effectiveness
9.2.8
(straight cable connectors only)

Discharge test at sea-level (corona effect) Extinction voltage
≥500
9.2.9
– cables 96IEC 50-3
Environmental
e
Climatic category 9.4.1 55/155/21
Sealing, non-hermetic 9.4.5.1
1cm /h 100 kPa~
110 kPa differential
Sealing, hermetic 9.4.5.2 5 pa cm /s

100 kPa – 110 kPa
differential
Salt mist 9.4.6 48 h spraying
Endurance
Mechanical 9.5 500 operations
e

High temperature 9.6
1 000 h at 155 C
NOTE na = not applicable.
a These values apply to the basic connector. In practice, these may be influenced by the cable used and reference
always be made to the actual values given in the detail specification.
b Values for a single pair of connectors.
c Voltages are r.m.s. values of a.c. at 40 Hz to 65 Hz , unless otherwise stated.
d Some cables usable with these connectors have ratings lower than the values given here.
e For certain connectors, the upper temperature limit is restricted by the cable characteristics. Reference should be
made to the relevant cable specification. When semi-rigid cables are used, the upper temperature is limited to
115 °C maximum.
f When interfaces are fully mated.

– 18 – 61169-38  IEC:2008
4.3 Test schedule and inspection requirements
4.3.1 Acceptance tests (see Table 8)
Table 8 – Acceptance tests
Test Assessment level M (higher) Assessment level H (lower)
method
Test AQL Test AQL
IEC 61169-1
IL Period IL Period
required % required %
Subclause
Group A1
Visual examination 9.1.2 a II 1,0 a S3 1,5
Group B1
Outline dimensions 9.1.3.1 a S4 0,4 a S3 4,0
Mechanical 9.1.3.3 a II 1,0 a S3 1,5
compatibility
Engagement and 9.3.6 a S4 0,40 Lot a S3 1,5 Lot
separation
Gauge retention 9.3.4 ia II 1,0 ia S3 1,5
(resilient contact)
Sealing, non-hermetic 9.4.5.1 ia II 0,65 by ia S3 1,0 by
Sealing, hermetic 9.4.5.2 ia II 0,015 ia S3 0,025
Voltage proof 9.2.6 a S4 0,40 lot a II 4,0 lot
Solderability piece 9.3.2.1.1 ia S4 0,40 ia S3 4,0
parts
Insulation resistance 9.2.5 a S4 0,40 a S3 4,0
NOTE a = suggested as applicable
ia = test suggested (if technically applicable)
IL = inspection level
AQL = acceptable quality level

61169-38  IEC:2008 – 19 –
4.3.2 Periodic tests (see Table 9)
There are no group C tests for levels H and M.
Table 9 – Periodic tests
Assessment level M (higher) Assessment level H (lower)
Test method
Test Number of Permitted Period Test Number of Permitted Period
IEC 61169-1
required specimens failures per required specimens failures per
subclause
group# group#
Group D1 (d)  6 1 3 years 3 1 3 years
Solderability 9.3.2.1.1 ia  ia
connector
assemblies
Resistance to 9.3.2.1.2 ia  ia
soldering heat
Mechanical tests
on cable fixing
- cable rotation 9.3.7.2 ia  ia
(nutation)
- cable pulling 9.3.8 ia  ia
- cable bending 9.3.9 ia  ia
- cable torsion 9.3.10 ia  ia
Group D2 (d)  6 1 3 years 3 1 3 years
Contact 9.2.3 a  a
resistance, outer
conductor and
screen continuity
centre conductor
continuity
Vibration 9.3.3 a
Damp heat, 9.4.3 a  a
steady state
Group D3 (d)  1* 1 3 years 1* 1 3 years
Dimensions 9.1.3.2 a  a
piece-parts and
materials
Group D4 (d)  6 1 3 years 3 1 3 years
Mechanical 9.5 a  a
endurance
High 9.6 a  a
temperature
endurance
Sulphur dioxide 9.4.8 na  na
Group D5 (d)  6 1 3 years 3 1 3 years
Reflection factor 9.2.1 a  a
Screening 9.2.8 a  a
effectiveness
Water immersion 9.2.7 ia  ia
Group D6 (d)  6 1 3 years 3 1 3 years
Contact 9.3.5 a  a
captivation
Rapid change of 9.4.4 na  na
temperature
– 20 – 61169-38  IEC:2008
Table 9 (continued)
Assessment level M (higher) Assessment level H (lower)
Test method
IEC 61169-1 Test Number of Permitted Period Test Number of Permitted Period
subclause required specimens failures per required specimens failures per
group# group#
Climatic 9.4.2 a  a
sequence
Group D7 (d)  1§ 3 years 1§ 3 years
Resistance to 9.7 ia  ia
solvents and
contaminating
fluids
Details of symbols, abbreviations and procedures:
a = suggested as applicable
ia = test suggested (if technically applicable)
na = not applicable
IL = inspection level
AQL = acceptable quality level
* = one set of piece-parts each style and variant, unless using common piece parts
# = for qualification approval (QA), a total of two failures only permitted for level H and 1 failure only for level M from
groups D1 to D7
§ = Group D7 – number of pairs for each solvent
(d) = destructive tests – specimens shall not be returned to stock

4.4 Procedures
4.4.1 Quality conformance inspection
This shall consist of test groups A1 and B1 on a lot-by-lot basis.
4.4.2 Qualification approval and its maintenance
This shall consist of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following
pages comprise the pro-forma BDS dedicated for use with type BNC connectors. As such, it
will already have entered on it information relating to
a) the basic specification number applicable to all the detail specifications covering
connector styles of the type covered by the sectional specification;
b) the connector series designation.
The specification writer should enter the details relating to the connector style/variant(s) to be
covered as indicated. The numbers in brackets on the BDS pro-forma correspond to the
following indications which shall be given.

61169-38  IEC:2008 – 21 –
5.2 Identification of the detail specification
(1) The name of the National Standards Organization (NSO) under whose authority the DS
is published and, if applicable, the organization from whom the DS is available.
(2) The relevant mark of conformity and the number allotted to the DS by the relevant
national or international organization authorizing the DS.
(3) The number and issue number of the IEC/IECQ generic or sectional specification as
relevant; also national reference if different.
(4) If different from the IEC/IECQ number, any national number of the DS, date of issue and
any further information required by the national system, together with any amendment
numbers.
5.3 Identification of the component
(5) Enter the following details:
Style: The style designation of the connector including type of fixing and sealing,
if applicable.
Attachment: By deletion of the inapplicable options of cable/wire: given for centre and
outer conductors.
Special features and markings: as applicable.
(6) Enter details of assessment level and the climatic category.
(7) A reproduction of the outline drawing and details of the panel piercing, if applicable. It
shall provide the maximum envelope dimensions, also the position of the reference
plane and, in the case of a fixed connector, the position of the mounting plane(s)
relative to the front face of the connector.
Any maximum panel thickness limitations for fixed connectors shall be stated.
(8) Particulars of all variants covered by the DS. As appropriate, the information shall
include:
• cable types (or sizes) applicable to each variant;
• alternative plated or protective finishes;
• details of alternative mounting flanges having either tapped or plain mounting
holes;
• details of alternative solder spills or solder buckets including, when applicable,
those for use with microwave integrated circuit (MIC) components.
5.4 Performance
(9) Performance data listing the most important characteristics of the connector taking into
account the recommended values of 4.2 in this specification. Deviations from the
minimum requirements shall be clearly indicated. Non-applicable parameters shall be
marked “na”.
5.5 Marking, ordering information and related matters
(10) Insert marking and ordering information as appropriate, together with details of related
documents and any invoked structural similarity.

– 22 – 61169-38  IEC:2008
5.6 Selection of tests, test conditions and severities
(11) “na” shall be used to indicate non-applicable tests. All tests marked “a” by the detail
specification writer shall be mandatory.
When using the normal procedure with a dedicated BDS, the letter “a” – for applicable –
shall be entered in the “Test required” column against each of the tests indicated as
being mandatory in the test schedule as in 4.3 of this specification. Any additional tests
required at the discretion of the specification writer shall also be indicated by an “a”.
The specification writer shall also indicate, when necessary, details of deviations from
the standard test methods and test conditions, including any relevant deviations given in
the test schedule of the sectional specification.
The qualification approval and conformance inspection shall be such that the national
supervising inspectorate (NSI) shall be satisfied that they are appropriate and in line
with those for other connectors within the system providing a reasonably comparable
service.
61169-38  IEC:2008 – 23 –
5.7 Blank detail specification pro-forma for type TMA connector
The following pages contain the complete BDS pro-forma.
(1)
Page 1 of ….
QC 222XXX
ELECTRONIC COMPONENT OF ASSESSED (4) ISSUE
QUALITY IN ACCORDANCE WITH
GENERIC SPECIFICATION QC 220000 .
SECTIONAL SPECIFICATION QC 222XXX
NATIONAL REFERENCE .
(5) Detail specification for type TMA
Radio frequency coaxial connector of assessed quality
Style:. Special features and markings
Method of cable/wire+ attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level. Characteristic impedance 50 Ω Climatic category./././
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description of variant 60096 IEC
01. . . . . .
..........
...