ISO/DIS 24443
(Main)Determination of sunscreen UVA photoprotection in vitro
Determination of sunscreen UVA photoprotection in vitro
Détermination in vitro de la photoprotection des produits de protection solaire aux UVA
General Information
RELATIONS
Buy Standard
Standards Content (sample)
DRAFT INTERNATIONAL STANDARD
ISO/DIS 24443
ISO/TC 217 Secretariat: ISIRI
Voting begins on: Voting terminates on:
2020-04-30 2020-07-23
Determination of sunscreen UVA photoprotection in vitro
Détermination in vitro de la photoprotection UVA
ICS: 71.100.70
THIS DOCUMENT IS A DRAFT CIRCULATED
This document is circulated as received from the committee secretariat.
FOR COMMENT AND APPROVAL. IT IS
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
ISO/CEN PARALLEL PROCESSING
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 24443:2020(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION. ISO 2020
---------------------- Page: 1 ----------------------
ISO/DIS 24443:2020(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2020
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2020 – All rights reserved
---------------------- Page: 2 ----------------------
ISO/DIS 24443:2020(E)
Contents Page
Foreword ........................................................................................................................................................................................................................................iv
Introduction ..................................................................................................................................................................................................................................v
1 Scope ................................................................................................................................................................................................................................. 1
2 Normative references ...................................................................................................................................................................................... 1
3 Terms and definitions ..................................................................................................................................................................................... 1
4 Principle ........................................................................................................................................................................................................................ 3
5 Apparatus ..................................................................................................................................................................................................................... 3
5.1 UV spectrophotometer specifications ................................................................................................................................. 3
5.2 Calibration of the UV spectrophotometer........................................................................................................................ 4
5.3 Calibration of the UV exposure source ............................................................................................................................... 4
5.4 Monitoring of the UV exposure source ............................................................................................................................... 4
5.5 Calibration of the UVA radiometer used to monitor the test sample irradiation .......................... 5
5.6 Substrate/plate ....................................................................................................................................................................................... 5
6 Test method ............................................................................................................................................................................................................... 5
6.1 Outline of the test procedure ...................................................................................................................................................... 5
6.2 Equipment calibration and validation of test plates............................................................................................... 6
6.3 Absorption measurements through the plate .............................................................................................................. 6
6.4 Sample application .............................................................................................................................................................................. 6
6.5 Absorbance measurements of the product-treated plate .................................................................................. 7
6.6 Number of determinations ........................................................................................................................................................... 7
6.7 Determination of initial calculated SPF (SPF ), “C” value, initial UVA-PF (UVA-
in vitroPF ), and UV exposure dose ......................................................................................................................................................... 7
6.7.1 Determination of SPF ......................................................................................................................................
in vitro 76.7.2 Determination of “C” value ...................................................................................................................................... 8
6.7.3 Determination of initial UVA protection factor before UV exposure (UVA-PF ) ....... 8
6.7.4 Determination of the UV exposure dose...................................................................................................... 9
6.8 UV exposure ............................................................................................................................................................................................... 9
6.9 Measurement of final adjusted absorbance spectrum ......................................................................................... 9
6.10 Calculation of UVA-PF of plates after UV exposure of the sample ...........................................................10
6.11 Calculation of critical wavelength of plates after UV exposure of the sample ..............................10
7 Procedure using the spreadsheet in this document .....................................................................................................10
8 Product reference sunscreen ...............................................................................................................................................................11
8.1 Formula S2 ...............................................................................................................................................................................................11
8.2 Standard P8 .............................................................................................................................................................................................11
9 Test report ................................................................................................................................................................................................................12
Annex A (normative) Calibration of UV spectrophotometer and plate transmission test.........................13
Annex B (normative) Radiometer calibration to spectroradiometric irradiance procedure ................17
Annex C (normative) Computation values: PPD and erythema action spectra and UVA and
UV-SSR spectral irradiances ...................................................................................................................................................................19
Annex D (normative) PMMA test plate surface specifications ................................................................................................22
Annex E (normative) UVA Product reference sunscreen S2 ......................................................................................................25
Annex F (informative) Statistical calculations .........................................................................................................................................31
Bibliography .............................................................................................................................................................................................................................34
© ISO 2020 – All rights reserved iii---------------------- Page: 3 ----------------------
ISO/DIS 24443:2020(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.This document was prepared by Technical Committee ISO/TC 217 Cosmetics.
This second edition cancels and replaces the first edition (ISO 24443:2012), which has been technically
revised.Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.iv © ISO 2020 – All rights reserved
---------------------- Page: 4 ----------------------
ISO/DIS 24443:2020(E)
Introduction
This International Standard specifies the procedure to determine the Ultraviolet A Protection Factor
(UVAPF) of a sunscreen product using the in vitro UVAPF according to the principles recommended
by COLIPA in 2011. The outcome of this test method can be used to determine the UVA classification of
topical sunscreen products according to local regulatory requirements.Topical sunscreen products are primarily rated and labelled according to their ability to protect against
sunburn, using a test method to determine the in vivo Sun Protection Factor (see ISO 24444). This
rating evaluates filtration of sunburn generating radiation across the electromagnetic UV spectrum
(290 nm to 400 nm). However, knowledge of the Sun Protection Factor (SPF) rating does not provide
explicit information on the magnitude of the protection provided specifically in the UVA range of
the spectrum (320 nm to 400 nm), as it is possible to have high SPF products with very modest UVA
protection (e.g. SPF 50 with a UVAPF of only 3 to 4). There is demand among medical professionals,
as well as knowledgeable consumers, to have fuller information on the UVA protection provided by
their sunscreen product, in addition to the SPF, in order to make a more informed choice of product,
providing a more balanced and broader-spectrum protection. Moreover, there also a demand to prevent
UVA-induced darkening of the skin from a cultural point of view even without sunburn. The UVAPF
value of a product provides information on the magnitude of the protection provided explicitly in the
UVA portion of the spectrum, independent of the SPF values.The test method outlined in this International Standard is derived primarily from the in vitro UVAPF
test method as developed by COLIPA.© ISO 2020 – All rights reserved v
---------------------- Page: 5 ----------------------
DRAFT INTERNATIONAL STANDARD ISO/DIS 24443:2020(E)
Determination of sunscreen UVA photoprotection in vitro
1 Scope
This document specifies an in vitro procedure to characterize the UVA protection of sunscreen products.
Specifications are proposed to enable determination of the spectral absorbance characteristics of UVA
protection in a reproducible manner.In order to determine relevant UVA protection parameters, the method has been created to provide an
UV spectral absorbance curve from which a number of calculations and evaluations can be undertaken.
Results from this measurement procedure can be used for other computations, as required by local
regulatory authorities. These include calculation of the Ultraviolet-A protection factor (UVA-PF)
[correlating with in vivo UVA-PF from the persistent pigment darkening (PPD) testing procedure],
critical wavelength and UVA absorbance proportionality. These computations are optional and relate
to local sunscreen product labelling requirements. This method relies on the use of static in vivo SPF
results for scaling the UV absorbance curve.This document is not applicable to powder products such as pressed powder and loose powder products.
2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 24444, Cosmetics — Sun protection test methods — In vivo determination of the sun protection
factor (SPF)3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp— IEC Electropedia: available at http:// www .electropedia .org/
3.1
in vitro UVA protection factor
UVA-PF
in vitro UVA protection factor of a sun protection product against UVA radiation, which can be derived
mathematically with in vitro spectral modelling3.2
in vitro protection factor
SPF , protection factor of a sun protection product against erythema-inducing radiation calculated
in vitrowith spectral modelling
3.3
critical wavelength, calculated from spectral data. It corresponds to the wavelength at which the area
under the absorbance curve represents 90 % of the total area under the curve in the UV region
© ISO 2020 – All rights reserved 1---------------------- Page: 6 ----------------------
ISO/DIS 24443:2020(E)
3.4
[1]
action spectrum for erythema [2].
E(λ)
relative effects of individual spectral bands of an exposure source for an erythema response
3.5[3]
action spectrum for PPD [4].
P(λ)
relative effects of individual spectral bands of an exposure source for a persistent pigment response
3.6monochromatic absorbance
sunscreen absorbance at wavelength, λ, related to the sunscreen transmittance, T , by
ATλ =−logwhere transmittance, T , is the fraction of incident irradiance transmitted by the sunscreen film
3.7irradiance
fluence rate per unit area, expressed in W/m , for a defined range of wavelengths
EXAMPLE From 290 nm to 400 nm for UVA + UV-B irradiance; from 320 nm to 400 nm for UVA irradiance.
3.8spectral irradiance for SPF testing or PPD testing
I(λ)
irradiance per unit wavelength, I(λ), expressed in W/m /nm
3.9
spectrophotometer
equipment for measuring the reflection or transmission properties of a material as a function of
wavelength limited to ultraviolet, visible and short infrared ranges in this document
3.10spectroradiometer
device designed to measure the spectral density of illuminants
3.11
radiometer
device for measuring the radiant flux (power) of electromagnetic radiation
3.12
reference product
reference sunscreen product used to validate the testing procedure
3.13
solar simulator
Equipment used to simulate the solar irradiance and spectrum.
3.14
substrate plate
Material to which the test product is to be applied.
2 © ISO 2020 – All rights reserved
---------------------- Page: 7 ----------------------
ISO/DIS 24443:2020(E)
4 Principle
The test is based on the assessment of UV-transmittance through a thin film of sunscreen sample spread
on a roughened substrate, before and after exposure to a controlled dose of radiation from a defined UV
exposure source.Because of the several variables that cannot be controlled with typical thin film spectroscopic
techniques, each set of sunscreen transmission data is mathematically adjusted so that the in vitro
SPF data yield the same measured in vivo SPF value that was determined by in vivo testing. As in vivo
method could raise ethical consideration, any alternative SPF method, published as an ISO method, may
be used.Samples are then exposed to a specific measured dose of UV radiation to account for the photostability
characteristics of the test product.The resulting spectral absorbance data have been shown to be a useful representation of both the
width and height of the UVA protection characteristics of the sunscreen product being tested. The
mathematical modelling procedure has been empirically derived to correlate with human in vivo
(persistent pigment darkening) test results.5 Apparatus
5.1 UV spectrophotometer specifications
The UV spectrophotometer wavelength range shall span the primary waveband of 290 nm to 400 nm.
The wavelength increment step shall be 1 nm.A UV spectrophotometer that does not have a monochromator after the test sample should employ a
fluorescence rejection filter.The UV spectrophotometer input optics should be designed for diffuse illumination and/or diffuse
collection of the transmitted irradiance through the roughened polymethylmethacrylate (PMMA)
substrate, with and without the sunscreen layer spread on its surface.The size of the diameter of the entrance port of the UV spectrophotometer probe shall be smaller than
the size of the light spot to be measured at the sample level (in order to account for stray light).
The area of each reading site should be at least 0,5 cm in order to reduce the variability between
readings and to compensate for the lack of uniformity in the product layer.The wavelength should be accurate to within 1 nm, as checked using a holmium-doped filter (see Annex
A). The ability of an instrument to accurately measure absorbance is limited by the sensitivity of the
instrument. The minimum required dynamic range for this methodology is 2,2 absorbance units as
determined according to Annex A.The maximum measured absorbance should be within the dynamic range of the device used. If
the test measurements yield absorbance curves that exceed the determined upper limit of the UV
spectrophotometer, the product should be re-tested using an instrument with increased sensitivity and
dynamic range.The lamp in the UV spectrophotometer that is used to measure the transmittance shall emit continuous
radiation over the range of 290 nm to 400 nm, and the level of irradiance should be sufficiently low, so
that the photostability of the product is not unduly challenged (a xenon lamp is a convenient solution).
Therefore, the UV dose during one measurement cycle should not exceed 0,2 J/cm .NOTE A UV spectrophotometer is used to measure the absorbance properties of the sunscreen on the test
plates. A spectroradiometer is used to measure the spectral energy distribution and intensity of the UV exposure
source or the UV spectrophotometer during the absorbance measurement of the sunscreen on the test plate.
Coupled with an UV source, the radiometer can give similar results to a spectrophotometer.
© ISO 2020 – All rights reserved 3---------------------- Page: 8 ----------------------
ISO/DIS 24443:2020(E)
5.2 Calibration of the UV spectrophotometer
The UV spectrophotometer shall be validated every month by measurements of reference materials.
A three-fold test is required, as described in Annex A:— dynamic range of the UV spectrophotometer;
— linearity test of the UV spectrophotometer;
— wavelength accuracy test.
5.3 Calibration of the UV exposure source
The spectral irradiance at the exposure plane of the UV exposure source that is used for irradiation
(to take into account any photoinstability) shall be as similar as possible to the irradiance at ground
[1] [2]level under a standard zenith sun. As defined by COLIPA, the reference standard sun has a total
irradiance of 51.4 to 63.7 W/m2 and a UVA to UVB irradiance ratio of 16.9 to 17.5.
Therefore, the UV irradiance shall be within the following acceptance limits (measured at sample
distance).Table 1 — UV exposure source specifications
UV exposure source specifications as measured with a spectroradiometer
2 2
Total UV irradiance (290 nm to 400 nm) 40 W/m to 200 W/m
a b
Irradiance ratio of UVA to UVB 11-22
320 nm to 400 nm.
290 nm to 320 nm.
In broad-beam UV-sources, spectra from different locations under the beam shall be recorded over at
least 5 different locations (a location is defined for each plate) in order to account for uniformity.
The uniformity shall be ≥ 90% as calculated by the equation:(1-(max-min)/(average))% ≥ 90% *
*If the uniformity is less than 90%, then optical components should be adjusted or appropriate
compensation for different irradiance shall be made in the exposure time on each plate.
The UV exposure source device should have the ability to maintain samples within the range of 27 °C
to 32 °C, with intra laboratory temperature ± 2 °C. It is important that the temperature of the sample
itself on the plate shall be measured and not just the surrounding air temperature. Therefore, the
measurement of the temperature shall be on plate level.To maintain samples at required temperature, a filter system that particularly reduces Infrared
radiation shall be used to achieve the specified temperature range. Cooling trays for the sample plates
or ventilators shall be used to maintain a temperature lower than 32 °C and warming devices to
maintain samples at or above 27 °C.Measurement to be made using a sensor that is traceable to a national or an international calibration
standard, within the range of use.5.4 Monitoring of the UV exposure source
The emission of the UV exposure source used for exposure shall be checked for compliance with the
given acceptance limits by a suitably qualified expert (at least) every 12 months, or 2500 hours of lamp
running time. The inspection should be conducted with a spectroradiometer that has been calibrated
against a standard lamp that is traceable to a national or an international calibration standard provided
4 © ISO 2020 – All rights reserved---------------------- Page: 9 ----------------------
ISO/DIS 24443:2020(E)
by an accredited ISO17025 laboratory. In addition to the spectroradiometric inspection, the intensity of
the UV exposure source used for exposure shall be checked prior to each use.This can be done using either a spectroradiometer or a radiometer with sensitivity in the UVA,
calibrated for the same UV exposure source spectrum used for the exposure step of the procedure,
applying the coefficient of calibration to adjust for variance between the UVA radiometer and the
reference spectroradiometer.5.5 Calibration of the UVA radiometer used to monitor the test sample irradiation
If a UVA radiometer is used, this device shall have been suitably calibrated. This requires that it be
calibrated to the spectroradiometer used to measure the exposure source (as during annual solar
simulator calibration).Calibration shall be conducted in terms of UVA irradiance (320 nm to 400 nm) and shall be at the
same level at which the test plates are exposed. Once calibrated with the spectroradiometer, the UVA
radiometer may be used to determine the UV doses to be used during the exposure procedure on a day-
to-day basis. Annex B provides the step-by-step calibration procedure.5.6 Substrate/plate
The substrate/plate is the material to which the test product is to be applied. For this method, PMMA
plates with one rough side of the substrate are to be used and are commercially available. The size of
the substrate should be chosen such that the application area is not less than 16 cm .
[9]The specifications and preparation of this type of plate are described in Annex D.
6 Test method6.1 Outline of the test procedure
6.1.1 Conduct the calibration and validation of the test equipment, including the UV spectrophotometer
used for transmission/absorbance measurements and the UVA radiometer (or spectroradiometer) used
to measure the UV exposure source, and verify the transmission properties of the test plates as described
in Annex D.6.1.2 Conduct blank measurements of a glycerin-treated or Vaseline-treated plate for the reference
“blank”, which will be used in the subsequent absorbance measurements.6.1.3 Conduct in vitro absorbance measurements of the sunscreen product spread on a PMMA plate,
prior to any UV irradiation. Acquire the initial mAf spectrum with A (λ) data.6.1.4 Conduct the mathematical adjustment of the initial UV absorbance spectrum using coefficient
“C” (see the calculation in 6.7.2) to achieve an in vitro SPF (no UV dose) equal to the measured static in
vivo SPF. Initial UVA-PF is calculated using A (λ) and C. A single UV exposure dose, D, is calculated, equal
0 0to 1,2 × UVA-PF in J/cm , for each plate
6.1.5 Conduct UV exposure of the same sample as in 6.1.3, according to the calculated UV exposure
dose D.6.1.6 Measure the in vitro absorbance of the sunscreen product after UV exposure. Acquire the second
UV spectrum with A(λ) data.© ISO 2020 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO/DIS 24443:2020(E)
6.1.7 Conduct the mathematical adjustment of the second mAf spectrum (following UV exposure) by
multiplying with the same “C” coefficient, previously determined in 6.1.4. The resulting absorbance curve
is the final adjusted absorbance values.6.2 Equipment calibration and validation of test plates
Test procedures as described in Annex A are to be completed to validate the wavelength accuracy,
linearity and absorbance limits of the UV spectrophotometer/spectroradiometer to be used for the test
procedure. Validation of the UV properties of the test PMMA plates shall also be conducted as described
in Annex D.6.3 Absorption measurements through the plate
It is necessary to first determine the absorbance of UV radiation through a “blank” PMMA plate.
Prepare a “blank” plate by spreading a few microlitres of glycerin/vaseline on the roughened side of the
plate. Choose the amount of glycerine/vaseline such that the entire surface is just completely covered
(approximately 15 μl for a 50 mm × 50 mm plate).Any excess of glycerine/vaseline should be avoided. Measure the absorbance through this “blank” plate
and use this as the baseline measurement for subsequent absorbance measurements.NOTE Many spectrophotometers have “baseline” functions to automatically incorporate this baseline
measurement into the calculations of subsequent absorbance measurements.6.4 Sample application
The sunscreen product is applied to a new untreated roughened PMMA plate (with the roughened side
uppermost) by mass, at an application rate of 1,3 mg/cm .To ensure dose accuracy and repeatability, the application area should be not less than 16 cm .
The application dose may be determined by measuring the mass loss of the pipette before and after
application of the product; alternatively, it may be applied based on volumetric measurements with
consideration of the specific gravity of the test sample. Where possible, a positive-displacement
automatic pipette should be used for this purpose.Plates should be weighed after application phase for any non-volatile product.
The sunscreen is applied as at least twelve small droplets of approximate equal volume, distributed
...PROJET DE NORME INTERNATIONALE
ISO/DIS 24443
ISO/TC 217 Secrétariat: ISIRI
Début de vote: Vote clos le:
2020-04-30 2020-07-23
Détermination in vitro de la photoprotection des produits
de protection solaire aux UVA
Determination of sunscreen UVA photoprotection in vitro
ICS: 71.100.70
CE DOCUMENT EST UN PROJET DIFFUSÉ POUR
OBSERVATIONS ET APPROBATION. IL EST DONC
SUSCEPTIBLE DE MODIFICATION ET NE PEUT
Le présent document est distribué tel qu’il est parvenu du secrétariat du comité.
ÊTRE CITÉ COMME NORME INTERNATIONALEAVANT SA PUBLICATION EN TANT QUE TELLE.
OUTRE LE FAIT D’ÊTRE EXAMINÉS POUR
ÉTABLIR S’ILS SONT ACCEPTABLES À DES
FINS INDUSTRIELLES, TECHNOLOGIQUES ET
COMMERCIALES, AINSI QUE DU POINT DE VUE TRAITEMENT PARALLÈLE ISO/CEN
DES UTILISATEURS, LES PROJETS DE NORMES
INTERNATIONALES DOIVENT PARFOIS ÊTRE
CONSIDÉRÉS DU POINT DE VUE DE LEUR
POSSIBILITÉ DE DEVENIR DES NORMES
POUVANT SERVIR DE RÉFÉRENCE DANS LA
RÉGLEMENTATION NATIONALE.
Numéro de référence
LES DESTINATAIRES DU PRÉSENT PROJET
ISO/DIS 24443:2020(F)
SONT INVITÉS À PRÉSENTER, AVEC LEURS
OBSERVATIONS, NOTIFICATION DES DROITS
DE PROPRIÉTÉ DONT ILS AURAIENT
ÉVENTUELLEMENT CONNAISSANCE ET À
FOURNIR UNE DOCUMENTATION EXPLICATIVE. ISO 2020
---------------------- Page: 1 ----------------------
ISO/DIS 24443:2020(F) ISO/DIS 24443:2020(F)
Sommaire Page
Avant-propos ................................................................................................................................................................... v
Introduction.................................................................................................................................................................... vi
1 Domaine d’application .................................................................................................................................. 1
2 Références normatives .................................................................................................................................. 1
3 Termes et définitions ..................................................................................................................................... 1
4 Principe ............................................................................................................................................................... 3
5 Appareillage ...................................................................................................................................................... 3
5.1 Spécifications relatives au spectrophotomètre UV ............................................................................. 3
5.2 Étalonnage du spectrophotomètre UV ..................................................................................................... 4
5.3 Étalonnage de la source d’exposition aux UV ........................................................................................ 5
5.4 Surveillance de la source d’exposition aux UV ..................................................................................... 6
5.5 Étalonnage du radiomètre UVA utilisé pour contrôler l’irradiation de l’échantillon
d’essai .................................................................................................................................................................. 6
5.6 Substrat/plaque ............................................................................................................................................... 6
6 Méthode d’essai ................................................................................................................................................ 6
6.1 Présentation du mode opératoire d’essai .............................................................................................. 6
6.2 Étalonnage de l’équipement et validation des plaques d’essai ...................................................... 7
6.3 Mesurages de l’absorption à travers la plaque ..................................................................................... 7
6.4 Application de l’échantillon ......................................................................................................................... 7
6.5 Mesurages de l’absorbance de la plaque traitée .................................................................................. 8
6.6 Nombre de déterminations .......................................................................................................................... 9
6.7 Détermination du FPS calculé initial (FPS ), de la valeur « C », du FPUVA initial
in vitro(FPUVA ) et de la dose d’exposition aux UV ........................................................................................... 9
6.7.1 Détermination du FPS ........................................................................................................................... 9
in vitro6.7.2 Détermination de la valeur « C » ................................................................................................................ 9
6.7.3 Détermination du facteur de protection UVA initial avant exposition aux UV(FPUVA ) .......................................................................................................................................................... 10
6.7.4 Détermination de la dose d’exposition aux UV .................................................................................. 11
6.8 Exposition aux UV ......................................................................................................................................... 11
6.9 Mesurage du spectre d’absorbance ajusté final ................................................................................ 12
6.10 Calcul du FPUVA des plaques après exposition de l’échantillon aux UV .................................. 12
6.11 Calcul de la longueur d’onde critique des plaques après exposition de l’échantillon
aux UV ............................................................................................................................................................... 13
7 Mode opératoire utilisant la feuille de calcul du présent document ......................................... 13
8 Produit de protection solaire de référence ........................................................................................ 14
DOCUMENT PROTÉGÉ PAR COPYRIGHT8.1 Formule S2 ...................................................................................................................................................... 14
© ISO 20208.2 Étalon P8 .......................................................................................................................................................... 14
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en oeuvre, aucune partie de cette
9 Rapport d’essai .............................................................................................................................................. 15
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
Annexe A (normative) Étalonnage du spectrophotomètre UV et contrôle de transmission de
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
la plaque .......................................................................................................................................................... 16
ISO copyright officeCase postale 401 • Ch. de Blandonnet 8
Annexe B (normative) Mode opératoire d’étalonnage du radiomètre/spectroradiomètre
CH-1214 Vernier, Genevapour le mesurage du flux ........................................................................................................................... 20
Tél.: +41 22 749 01 11Fax: +41 22 749 09 47
E-mail: copyright@iso.org
Website: www.iso.org
Publié en Suisse
iii
© ISO 2020 – Tous droits réservés
ii © ISO 2020 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/DIS 24443:2020(F)
Sommaire Page
Avant-propos ................................................................................................................................................................... v
Introduction.................................................................................................................................................................... vi
1 Domaine d’application .................................................................................................................................. 1
2 Références normatives .................................................................................................................................. 1
3 Termes et définitions ..................................................................................................................................... 1
4 Principe ............................................................................................................................................................... 3
5 Appareillage ...................................................................................................................................................... 3
5.1 Spécifications relatives au spectrophotomètre UV ............................................................................. 3
5.2 Étalonnage du spectrophotomètre UV ..................................................................................................... 4
5.3 Étalonnage de la source d’exposition aux UV ........................................................................................ 5
5.4 Surveillance de la source d’exposition aux UV ..................................................................................... 6
5.5 Étalonnage du radiomètre UVA utilisé pour contrôler l’irradiation de l’échantillon
d’essai .................................................................................................................................................................. 6
5.6 Substrat/plaque ............................................................................................................................................... 6
6 Méthode d’essai ................................................................................................................................................ 6
6.1 Présentation du mode opératoire d’essai .............................................................................................. 6
6.2 Étalonnage de l’équipement et validation des plaques d’essai ...................................................... 7
6.3 Mesurages de l’absorption à travers la plaque ..................................................................................... 7
6.4 Application de l’échantillon ......................................................................................................................... 7
6.5 Mesurages de l’absorbance de la plaque traitée .................................................................................. 8
6.6 Nombre de déterminations .......................................................................................................................... 9
6.7 Détermination du FPS calculé initial (FPS ), de la valeur « C », du FPUVA initial
in vitro(FPUVA ) et de la dose d’exposition aux UV ........................................................................................... 9
6.7.1 Détermination du FPS ........................................................................................................................... 9
in vitro6.7.2 Détermination de la valeur « C » ................................................................................................................ 9
6.7.3 Détermination du facteur de protection UVA initial avant exposition aux UV(FPUVA ) .......................................................................................................................................................... 10
6.7.4 Détermination de la dose d’exposition aux UV .................................................................................. 11
6.8 Exposition aux UV ......................................................................................................................................... 11
6.9 Mesurage du spectre d’absorbance ajusté final ................................................................................ 12
6.10 Calcul du FPUVA des plaques après exposition de l’échantillon aux UV .................................. 12
6.11 Calcul de la longueur d’onde critique des plaques après exposition de l’échantillon
aux UV ............................................................................................................................................................... 13
7 Mode opératoire utilisant la feuille de calcul du présent document ......................................... 13
8 Produit de protection solaire de référence ........................................................................................ 14
8.1 Formule S2 ...................................................................................................................................................... 14
8.2 Étalon P8 .......................................................................................................................................................... 14
9 Rapport d’essai .............................................................................................................................................. 15
Annexe A (normative) Étalonnage du spectrophotomètre UV et contrôle de transmission de
la plaque .......................................................................................................................................................... 16
Annexe B (normative) Mode opératoire d’étalonnage du radiomètre/spectroradiomètre
pour le mesurage du flux ........................................................................................................................... 20
iii© ISO 2020 – Tous droits réservés
---------------------- Page: 3 ----------------------
ISO/DIS 24443:2020(F)
Annexe C (normative) Valeurs de calcul : Spectres d’action de la PPD et de l’érythème et
intensité de l’irradiance spectrale des sources UVA et UV-SSR ................................................... 22
Annexe D (normative) Spécifications de la surface des plaques d’essai de PMMA ............................. 26
Annexe E (normative) Produit de protection solaire de référence UVA S2 ........................................... 29
Annexe F (informative) Calculs statistiques ...................................................................................................... 36
Bibliographie ................................................................................................................................................................ 39
© ISO 2020 – Tous droits réservés---------------------- Page: 4 ----------------------
ISO/DIS 24443:2020(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le
droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2
(voir www.iso.org/directives).L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant les
références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant : www.iso.org/iso/fr/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 217, Cosmétiques.
Cette deuxième édition annule et remplace la première édition (ISO 24443:2012), qui a fait l’objet d’une
révision technique.Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html.© ISO 2020 – Tous droits réservés
---------------------- Page: 5 ----------------------
ISO/DIS 24443:2020(F)
Introduction
La présente Norme internationale spécifie le mode opératoire permettant de déterminer le facteur de
protection contre les ultraviolets A (FPUVA) d’un produit de protection solaire à l’aide du FPUVA
in vitro conformément aux principes recommandés par la COLIPA en 2011. Le résultat de cette méthode
d’essai peut être utilisé pour déterminer la classification UVA de produits de protection solaire topiques
conformément aux exigences réglementaires locales.Les produits de protection solaire sont principalement évalués et étiquetés par rapport à leur capacité à
protéger contre les coups de soleil, à l’aide d’une méthode d’essai permettant de déterminer le facteur
de protection solaire in vivo (voir ISO 24444). Cette classification permet d’évaluer la filtration des
rayonnements provoquant des coups de soleil sur l’ensemble du spectre UV électromagnétique
(290 nm à 400 nm). Cependant, connaître le facteur de protection solaire (FPS) ne fournit pas
d’informations explicites sur l’ampleur de la protection fournie, en particulier dans la plage UVA du
spectre (320 nm à 400 nm), étant donné que certains produits ont un indice FPS élevé, mais protègent
très peu contre les UVA (par exemple un FPS 50 avec un FPUVA de seulement 3 à 4). Les professionnels
de la santé ainsi que les consommateurs bien informés demandent à disposer d’informations plus
détaillées sur la protection UVA fournie par leur produit de protection solaire, en plus du FPS, afin de
pouvoir choisir de façon plus éclairée un produit fournissant un spectre de protection plus vaste et plus
équilibré. De plus, une demande existe également en matière de prévention de la pigmentation de la
peau liée aux UVA d’un point de vue culturel, même sans prendre en considération les coups de soleil.
La valeur FPUVA d’un produit apporte des informations sur le niveau de protection fourni explicitement
dans la partie UVA du spectre, et ce indépendamment des valeurs de FPS.La méthode d’essai décrite dans la présente Norme internationale découle principalement de la
méthode d’essai FPUVA in vitro qui a été conçue par la COLIPA.© ISO 2020 – Tous droits réservés
---------------------- Page: 6 ----------------------
PROJET DE NORME INTERNATIONALE ISO/DIS 24443:2020(F)
Détermination in vitro de la photoprotection des produits de
protection solaire aux UVA
1 Domaine d’application
Le présent document spécifie un mode opératoire in vitro pour caractériser la protection UVA apportée
par les produits de protection solaire. Des spécifications sont proposées pour permettre de déterminer
les caractéristiques d’absorbance spectrale de la protection UVA de façon reproductible.
Afin de déterminer les paramètres de protection UVA pertinents, la méthode a été mise au point de
sorte à fournir une courbe d’absorbance spectrale UV à partir de laquelle des calculs et des évaluations
peuvent être effectués. Les résultats de ce mode opératoire de mesure peuvent être utilisés pour
d’autres calculs exigés par les autorités réglementaires locales. Ces calculs comprennent le calcul du
facteur de protection contre les ultraviolets A (FPUVA) [corrélé au FPUVA in vivo du mode opératoire
d’essai de pigmentation persistante (PPD)], de la longueur d’onde critique et de la proportionnalité de
l’absorbance des UVA. Ces calculs sont facultatifs et sont liés aux exigences d’étiquetage locales des
produits de protection solaire. Cette méthode repose sur les résultats du FPS in vivo statique pour
élaborer la courbe d’absorbance des UV.Le présent document n’est pas applicable aux produits sous forme de poudre tels que les produits en
poudre compacte ou en poudre libre.2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur
contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s’applique (y compris les
éventuels amendements).ISO 24444, Cosmétiques — Méthodes d’essai de protection solaire — Détermination in vivo du facteur de
protection solaire (FPS).3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes :— ISO Online browsing platform : disponible à l’adresse https://www.iso.org/obp ;
— IEC Electropedia : disponible à l’adresse http://www.electropedia.org/.© ISO 2020 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO/DIS 24443:2020(F)
3.1
facteur de protection UVA in vitro
FPUVA
facteur de protection UVA in vitro d’un produit de protection solaire contre le rayonnement UVA
pouvant être calculé mathématiquement par modélisation spectrale in vitro3.2
facteur de protection in vitro
FPS , facteur de protection d’un produit solaire contre l’érythème induit par un rayonnement,
in vitrocalculé par modélisation spectrale
3.3
longueur d’onde critique, calculée à partir des données spectrales, qui correspond à la longueur d’onde
à laquelle la zone située sous la courbe d’absorbance représente 90 % de la zone totale sous la courbe
dans la région UV3.4
[1]
spectre d’action de l’érythème [2]
E(λ)
effets relatifs des bandes spectrales individuelles d’une source d’exposition pour une réponse
érythémale3.5
[3]
spectre d’action de PPD [4].
P(λ)
effets relatifs des bandes spectrales individuelles d’une source d’exposition pour une réponse de
pigmentation persistante3.6
absorbance monochromatique
absorbance du produit de protection solaire à la longueur d’onde, λ, corrélée à la transmittance du
produit de protection solaire, T , parAT log
où la transmittance, T , est la fraction de l’irradiance incidente transmise par le film de protection
solaire3.7
irradiance
puissance par unité de surface, exprimée en W/m , pour une plage définie de longueurs d’onde
EXEMPLE : De 290 nm à 400 nm pour l’irradiance UVA + UVB ou de 320 nm à 400 nm pour l’irradiance UVA.
3.8irradiance spectrale pour les essais du FPS ou de la PPD
I(λ)
irradiance par unité de longueur d’onde, I(λ), exprimée en W/m /nm
© ISO 2020 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO/DIS 24443:2020(F)
3.9
spectrophotomètre
équipement destiné à mesurer les propriétés de réflexion ou de transmission d’un matériau en fonction
de la longueur d’onde limitée aux plages de rayonnements ultraviolets, visibles et infrarouges courts
dans le présent document3.10
spectroradiomètre
dispositif conçu pour mesurer la densité spectrale des sources lumineuses
3.11
radiomètre
dispositif destiné à mesurer le flux énergétique (puissance) du rayonnement électromagnétique
3.12produit de référence
produit de protection solaire de référence utilisé pour valider le mode opératoire d’essai
3.13simulateur solaire
équipement utilisé pour simuler l’irradiance et le spectre solaires
3.14
plaque de substrat
matériau sur lequel le produit d’essai est destiné à être appliqué
4 Principe
L’essai est fondé sur l’évaluation de la transmittance UV à travers un film mince d’échantillon de produit
de protection solaire étalé sur un substrat rugueux, avant et après exposition à une dose contrôlée de
rayonnement à partir d’une source d’exposition aux UV définie.Étant donné que plusieurs variables ne peuvent pas être contrôlées à l’aide des techniques
spectroscopiques sur film mince habituelles, chaque série de données de transmission pour le produit
de protection solaire est mathématiquement ajustée de façon que les données FPS in vitro obtiennent la
valeur FPS in vivo mesurée qui avait été déterminée par des essais in vivo. Étant donné que la méthode
in vivo pourrait soulever des problèmes d’éthique, toute méthode de FPS alternative, publiée en tant
que méthode ISO, peut être utilisée.Les échantillons sont ensuite exposés à une dose mesurée spécifique de rayonnement UV pour tenir
compte des caractéristiques de photostabilité du produit d’essai.Il a été démontré que les données d’absorbance spectrale qui en résultent constituent une
représentation utile de la largeur et de l’intensité des caractéristiques de protection UVA du produit de
protection solaire soumis à essai. Le mode opératoire de modélisation mathématique a été obtenu de
façon empirique pour être corrélé aux résultats d’essai in vivo (pigmentation persistante) chez l’homme.
5 Appareillage5.1 Spécifications relatives au spectrophotomètre UV
La plage de longueur d’onde du spectrophotomètre UV doit couvrir la bande spectrale de 290 nm à
400 nm. L’incrément de la longueur d’onde doit être de 1 nm.© ISO 2020 – Tous droits réservés
---------------------- Page: 9 ----------------------
ISO/DIS 24443:2020(F)
Il convient qu’un spectrophotomètre UV qui ne comporte pas un monochromateur après l’échantillon
d’essai emploie un filtre de réjection de la fluorescence.Il convient que l’optique d’entrée du spectrophotomètre UV soit conçue pour collecter l’ensemble de
l’irradiance diffuse transmise à travers le substrat de polyméthacrylate de méthyle (PMMA) rugueux,
sans ou avec la couche de produit de protection solaire étalée sur sa surface.La taille du diamètre de l’orifice d’entrée de la sonde du spectrophotomètre UV doit être inférieure à la
taille du spot lumineux à mesurer au niveau de l’échantillon (afin de tenir compte du rayonnement
parasite).Il convient que la surface de chaque site de lecture soit au moins égale à 0,5 cm afin de réduire la
variabilité entre les lectures et de compenser le manque d’uniformité de la couche de produit.
Il convient que l’exactitude de la longueur d’onde se trouve dans la plage 1 nm, telle que vérifiée à l’aide
d’un filtre holmium (voir Annexe A). La capacité d’un instrument à mesurer exactement l’absorbance
est limitée par la sensibilité de l’instrument. La plage dynamique minimale nécessaire pour cette
méthodologie est de 2,2 unités d’absorbance telle que déterminée conformément à l’Annexe A.
Il convient que l’absorbance maximale mesurée soit comprise dans la plage dynamique du dispositif
utilisé. Si les mesurages produisent des courbes d’absorbance qui dépassent la limite supérieure
déterminée du spectrophotomètre UV, il convient de renouveler l’essai en utilisant un instrument ayant
une sensibilité et une plage dynamique plus élevées.La lampe dans le spectrophotomètre UV utilisée lors du mesurage de la transmittance doit émettre un
rayonnement continu sur la plage de 290 nm à 400 nm. Il convient par ailleurs que le niveau
d’irradiance soit suffisamment faible, de sorte que la photostabilité du produit ne soit pas indûment
remise en question (une lampe au xénon est une solution qui convient).Par conséquent, il convient que la dose d’UV pendant un cycle de mesure ne dépasse pas 0,2 J/cm .
NOTE Un spectrophotomètre UV est utilisé pour mesurer les propriétés d’absorbance du produit de protection
solaire sur les plaques d’essai. Un spectroradiomètre est utilisé pour mesurer la répartition d’énergie spectrale et
l’intensité de la source d’exposition UV ou le spectrophotomètre UV pendant le mesurage de l’absorbance du
produit de protection solaire sur la plaque d’essai. Associé à une source d’UV, le radiomètre peut fournir des
résultats semblables à ceux d’un spectrophotomètre.5.2 Étalonnage du spectrophotomètre UV
Le spectrophotomètre UV doit être validé chaque mois en mesurant des matériaux de référence.
Un essai réalisé en trois p...
Questions, Comments and Discussion