ISO/FDIS 4302
(Main)Cranes — Wind load assessment
- Abstract
ISO 4302:2016 specifies the assessment of wind loads on cranes. It establishes general methods for calculating wind loads (for in-service and out-of-service conditions), which are included in the load combinations stated in ISO 8686-1 and used for proofs of competence such as those given in ISO 20332 for the structural components of cranes. It provides a simplified method of calculation and assumes that - the wind may blow horizontally from any direction, - the wind blows at a constant speed, - there is a static reaction to the wind load applied to the crane structure. It includes built-in allowances for the effects of gusting (fluctuation in wind speed) and for dynamic response. It gives guidance on when to secure the crane for out-of-service conditions.
- Status
- Not Published
- Technical Committee
- ISO/TC 96/SC 10 - Design principles and requirements
- Drafting Committee
- ISO/TC 96/SC 10/WG 1 - Panel of technical experts
- Current Stage
- 5020 - FDIS ballot initiated: 2 months. Proof sent to secretariat
- Start Date
- 15-Oct-2026
- Completion Date
- 15-Oct-2026
Buy Documents
ISO/FDIS 4302 - Cranes — Wind load assessment
REDLINE ISO/FDIS 4302 - Cranes — Wind load assessment
ISO/FDIS 4302 is an ISO draft International Standard on wind load assessment for cranes. It specifies simplified methods for calculating wind actions in service and out of service, and those results are used in crane load combinations and proofs of competence. It is written for crane designers, structural engineers, verifiers, and people who need to decide how a crane should be secured in wind.
What does ISO/FDIS 4302 specify?
ISO/FDIS 4302 specifies the method for determining wind loads on cranes. It organizes the subject into general terms and symbols, wind pressure, in-service wind, out-of-service wind, and an informative annex with reference storm wind speeds.
| Annex | What it covers |
|---|---|
| Annex A | Informative reference storm wind speeds and storm wind maps for selected countries and regions |
The document uses a simplified calculation method. It assumes horizontal wind from any direction, constant wind speed, and a static reaction of the crane structure, while still allowing for gusts and dynamic response.
What are the key requirements of ISO/FDIS 4302?
ISO/FDIS 4302 requires wind actions to be assessed separately for in-service and out-of-service conditions, using the crane configuration and operating condition that matter for the case under review. In practice, the reader has to choose the right crane state first, because the wind load depends on whether the crane is operating, parked, or secured.
Wind pressure and the calculation basis
Clause 4 defines wind pressure from air density and wind speed, with a simplified SI expression for design use. This is the basic step for turning a wind speed into a load that can be combined with other crane actions.
In-service wind
Clause 5.1 says the in-service wind load shall be determined for the specific crane configuration and operating condition, taking the other actions in the load combination into account. It also points to typical in-service design wind speeds for different crane types and uses, so the designer can select a practical basis for operation in light winds, normal outdoor use, or process work in higher winds.
Clause 5.2 requires the wind action on the hoist load to be included and clearly described. The load on the suspended load is calculated from its shape coefficient, reference wind area, and wind pressure, and when the load details are not known the clause gives default assumptions based on mass. That matters because the lifted load can govern the design wind action, not just the crane structure.
Clause 5.3 applies the same general calculation to crane structures and individual members. The total wind load is taken as the sum of the loads on the members, so the reader has to break the crane into the elements that face the wind and assign each one a suitable area and coefficient.
Clause 5.4 gives shape coefficients for individual members, single lattice frames, and machinery houses. These coefficients depend on aerodynamic slenderness and, for box sections, on section ratio. In practice, this is where the geometry of tubes, latticework, plates, and cladded housings changes the wind load.
Clause 5.5 covers shielding for parallel frames or members. Sheltered parts use a shielding factor from the clause’s table, based on solidity and spacing ratios, and for several identical frames the shielding effect increases up to the ninth frame. This matters for cranes with repeated trusses or grouped members, where the rear elements do not see full wind.
Clause 5.6 covers members inclined to the wind direction. The wind load is based on the wind-speed component perpendicular to the member or surface, and the same idea is adapted for out-of-service conditions by using height-dependent wind speed. This lets the method handle booms, luffs, and other parts that are not square to the wind.
Out-of-service wind
Clause 6.1 requires the out-of-service wind load to be selected for the specific crane configuration, the site location, the exposure to local winds, and the risk preference typical for the crane type. The practical result is that the parked or secured condition is not generic - it must fit the installation site.
Clause 6.2 states that out-of-service wind acts horizontally and increases with height above ground. The clause applies to both crane members and any suspended load that remains attached, which means the securing strategy must consider not only the structure but also what may still hang from it.
Clause 6.3 defines the equivalent static out-of-service wind pressure and wind speed using recurrence interval, reference storm wind speed, gust response factor, and terrain-roughness coefficient. It also gives simplified and conservative calculation routes and points to Annex A for guidance where local wind maps or standards are not available.
What terms does ISO/FDIS 4302 define?
- In-service wind - the maximum wind that the crane is designed to withstand while operating.
- Out-of-service wind - the maximum storm wind from the least favourable direction that the crane is designed to withstand when parked or secured.
- Terrain-roughness coefficient - a factor that reflects how ground roughness and height above ground change wind speed at the site.
- Shape coefficient - a factor that translates the geometry of a member, frame, or load into wind action.
- Shielding factor - a factor that reduces wind load on sheltered parts of parallel frames or members.
- Gust response factor - a factor that accounts for gust effects in the equivalent static out-of-service wind speed.
- Reference storm wind speed - the site-based storm wind speed used as the starting point for out-of-service wind assessment.
Who uses ISO/FDIS 4302?
ISO/FDIS 4302 is used by crane manufacturers, structural designers, and verification engineers who need wind loads for design checks. It also supports operators and site planners who need to decide when a crane should be secured, lowered, or otherwise protected against wind. Buyers and quality managers can use it to compare how different crane configurations are intended to perform in wind-sensitive service.
What changed in ISO/FDIS 4302 from the previous edition?
ISO/FDIS 4302 is the third edition and replaces ISO 4302:2016.
The foreword states these main changes:
- Table 1 adds the symbols applicable to the document.
- The former Clause 6.4 on wind loads on individual members inclined to the wind direction is replaced by material added to Clause 5.6.
- The former Clause 6.5 on storm wind maps is replaced by a generalized statement added to Clause 6.3.
- Annex A has updated wind maps.
- Editorial changes appear throughout the text.
Which standards are used with ISO/FDIS 4302?
ISO/FDIS 4302 cites ISO 4306-1 as the normative vocabulary reference for crane terms. The scope also names the ISO 8686 series for load combinations and ISO 20332 for proofs of competence of steel crane structures, so the wind loads calculated here feed into broader design verification.
The bibliography also lists EN 1991-1-4:2026, ASCE/SEI 7-22, AS/NZS 1170.2:2021, GB 50009:2012, and FEM 1.001 as wind-action and crane-design references that can support local design practice.
What does the ISO/FDIS 4302 document contain?
ISO/FDIS 4302 contains calculation formulas for wind pressure, in-service wind loads, and out-of-service wind loads, together with the symbols needed to use them. It includes tables for usual in-service design wind speeds, shape coefficients, and shielding factors, plus figures that define aerodynamic slenderness and solidity or spacing ratios. Annex A gives informative storm wind maps and reference storm wind speeds for selected countries and regions, which is useful when local wind data or national maps are unavailable. The document is aimed at design calculations, verification of crane structures, and decisions about securing cranes against wind.
Relations
- Effective Date
- 20-Apr-2024
Buy Documents
ISO/FDIS 4302 - Cranes — Wind load assessment
REDLINE ISO/FDIS 4302 - Cranes — Wind load assessment
Frequently Asked Questions
ISO/FDIS 4302 is a draft published by the International Organization for Standardization (ISO). Its full title is "Cranes — Wind load assessment". This standard covers: ISO 4302:2016 specifies the assessment of wind loads on cranes. It establishes general methods for calculating wind loads (for in-service and out-of-service conditions), which are included in the load combinations stated in ISO 8686-1 and used for proofs of competence such as those given in ISO 20332 for the structural components of cranes. It provides a simplified method of calculation and assumes that - the wind may blow horizontally from any direction, - the wind blows at a constant speed, - there is a static reaction to the wind load applied to the crane structure. It includes built-in allowances for the effects of gusting (fluctuation in wind speed) and for dynamic response. It gives guidance on when to secure the crane for out-of-service conditions.
ISO 4302:2016 specifies the assessment of wind loads on cranes. It establishes general methods for calculating wind loads (for in-service and out-of-service conditions), which are included in the load combinations stated in ISO 8686-1 and used for proofs of competence such as those given in ISO 20332 for the structural components of cranes. It provides a simplified method of calculation and assumes that - the wind may blow horizontally from any direction, - the wind blows at a constant speed, - there is a static reaction to the wind load applied to the crane structure. It includes built-in allowances for the effects of gusting (fluctuation in wind speed) and for dynamic response. It gives guidance on when to secure the crane for out-of-service conditions.
ISO/FDIS 4302 is classified under the following ICS (International Classification for Standards) categories: 53.020.20 - Cranes. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/FDIS 4302 has the following relationships with other standards: It is inter standard links to ISO 4302:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO/FDIS 4302 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
FINAL DRAFT
International
Standard
ISO/TC 96/SC 10
Cranes — Wind load assessment
Secretariat: DIN
Appareils de levage à charge suspendue — Évaluation des
Voting begins on:
charges dues au vent
2026-10-15
Voting terminates on:
2026-12-10
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
MADE IN NATIONAL REGULATIONS.
Reference number
FINAL DRAFT
International
Standard
ISO/TC 96/SC 10
Cranes — Wind load assessment
Secretariat: DIN
Appareils de levage à charge suspendue — Évaluation des
Voting begins on:
charges dues au vent
Voting terminates on:
© ISO 2026
All rights reserved.
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
an ISO member body, or an authorized third-party distributor.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
photocopying, scanning, recording, or posting on internal or external digital platforms. TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
MADE IN NATIONAL REGULATIONS.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
Reference number
ii
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions .1
3.2 Symbols .2
4 Wind pressure . 3
5 In-service wind . 3
5.1 General .3
5.2 Action of in-service wind on hoist load .4
5.3 Wind load calculations .4
5.4 Shape coefficients for individual members, frames, etc. .4
5.5 Shielding factors — Multiple frames or members .5
5.6 Wind loads on individual members (inclined to the wind direction).7
6 Out-of-service wind . 8
6.1 General .8
6.2 Loads due to out-of-service wind .8
6.3 Equivalent static out-of-service wind pressure .8
Annex A (informative) Reference storm wind speeds . 10
Bibliography .20
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 96, Cranes, Subcommittee SC 10, Design
principles and requirements.
This third edition cancels and replaces the second edition (ISO 4302:2016), which has been technically
revised.
The main changes are as follows:
— In Table 1, all symbols applicable to this document have been added;
— The original Clause 6.4, “Wind loads on individual members (inclined to the wind direction)” has been
replaced by a requirement added at the end of Clause 5.6;
— The original Clause 6.5, “Storm wind maps” has been replaced by a generalized statement added at the
end of Clause 6.3;
— In Annex A, the wind maps have been updated;
— Editorial changes have been made throughout the text.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
FINAL DRAFT International Standard ISO/FDIS 4302:2026(en)
Cranes — Wind load assessment
1 Scope
This document specifies the method for determining the wind loads on cranes.
It establishes general methods for calculating wind load actions (for in-service and out-of-service conditions),
which are included in the load combinations specified in ISO 8686 series and used for proofs of competence
such as those given e.g. in ISO 20332 for the verification of structural components of cranes.
This document provides a simplified method of calculation and assumes that:
— the wind can blow horizontally from any direction;
— the wind blows at a constant speed;
— there is a static reaction to the wind load applied to the crane structure.
The method takes into account the effects of gusts (fluctuations in wind speed) as well as the dynamic
behaviour (response) of the crane.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 4306-1, Cranes — Vocabulary — Part 1: General
3 Terms, definitions and symbols
For the purposes of this document, the terms and definitions given in ISO 4306-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1 Terms and definitions
3.1.1
in-service wind
maximum wind that the crane is designed to withstand under operating conditions
3.1.2
out-of-service wind
maximum (storm) wind blowing from the least favourable direction that a crane is designed to withstand
when in an out-of-service condition
3.1.3
terrain-roughness coefficient
variability of the wind speed at the site of the crane due to the height above ground level and the ground
roughness of the terrain upwind of the crane structure in the wind direction considered
3.2 Symbols
Table 1 lists the symbols applicable to this document.
Table 1 — Main symbols
Symbol Description
A Area of solid part
A Enclosed area
e
A Reference wind area of the hoist load
HL
A Total solid area of all members across wind front
members
a Distance between facing sides
b Breadth of member across wind front
c , c Shape coefficients
f HL
D Diameter of a circular section
d Depth of section parallel to wind flow
F Wind load
f Recurrence-interval factor
rec
K Terrain-roughness coefficient
F Wind load due to the wind on the hoist load
HL
l Length of member
m Mass of the gross or hoist load in kilograms
HL
q In-service wind pressure
q(z) Equivalent static out-of-service wind pressure at height z
R Recurrence-interval
v 3-s-gust amplitude
g
v Wind speed, used as a basis of the calculation
s
Wind speed component acting perpendicularly to the longitudinal axis or surface of a
v *
s
member
v(z) Equivalent static out-of-service wind speed at the height z
Wind speed component acting perpendicularly to the longitudinal axis of a member at
v(z)*
height z
v (z) 10-min-mean storm wind speed at height z, in metres per second
m
v Reference storm wind speed
ref
z Height above the surrounding ground level, in metres
Φ Gust response factor
θ Angle of the wind direction to the longitudinal axis or face (θ < 90°)
η Shielding factor
η Factor for the remaining hoist load in out-of-service condition
w
ρ Density of the air
4 Wind pressure
The wind pressure q is given by Formula (1):
qv (1)
s
where
ρ is the density of air which, for design purposes, is assumed to be constant ρ = 1,225 kg/m ;
v is the wind speed, used as a basis of the calculation.
s
When using the international system of units (SI), where q is expressed in N/m and v in metres per second
s
(m/s), Formula (2) applies:
qv0,613 (2)
s
5 In-service wind
5.1 General
The in-service wind load shall be determined for the specific crane configuration and operating condition,
taking into account the other load actions of the load combination under consideration.
NOTE 1 The wind load is determined such that the maximum load effect relevant for the proof of competence is
reached. It is noted that the wind direction creating the maximum wind load action usually does not coincide with the
directions of the loads from other load actions.
The in-service design wind speed (resp. design wind pressure) shall be specified based on the type of crane,
crane configuration and operating condition. Table 2 provides a selection of usual in-service design wind
speeds depending on either the type of crane or its intended use.
Table 2 — In-service design wind speeds v and pressures q
s
Design wind pres-
Design wind speed
sure
v
Type of crane or application
s
q
m/s N/m
Cranes that are easily secured against wind action and which are de-
signed for operation in light winds only (e.g. cranes of low chassis height 14,3 125
with booms that can be readily lowered to the ground)
All normal types of cranes installed in the open 20,2 250
Cranes in process applications, where a crane shall continue to work
28,6 500
in high winds
The wind speeds applicable to different crane configurations and for initiating securing measures shall be
specified.
NOTE 2 The in-service design wind speed given in Table 2 is based on the assumption that the crane can be
fully secured in an out-of-service configuration before this wind speed is exceeded. As the means of securing vary
depending on crane type and configuration (e.g. locking devices at specific locations along the crane runway, hand-
operated or automatic rail clamps, etc.), securing is in some cases initiated at a lower wind speed to allow sufficient
time for the securing procedure to be completed.
5.2 Action of in-service wind on hoist load
On all cranes, the action of the wind on the load shall be taken into account and the method by which this is
done shall be clearly described. This can be accomplished by use of wind loads on load parameters of size
and shape. The wind load F on the load shall be calculated as a minimum in accordance with Formula (3):
HL
FcAq (3)
HL HL HL
where
F is the wind load on the hoist load in the direction of the wind; see ISO 4306-1;
HL
c is the shape coefficient of the hoist load;
HL
A is the reference wind area of the hoist load;
HL
q is the wind pressure corresponding to appropriate design condition.
In the absence of detailed information on the composition of the hoist load, it shall be assumed that c = 2,4
HL
and A = 0,000 5 × m , where A is expressed in square metres (m ) and m is the mass of the hoist
HL HL HL HL
load in kilograms (kg).
5.3 Wind load calculations
For crane structures or individual members used in crane structures, the wind load F in the direction of the
wind, is calculated from Formula (4):
FcAq (4)
f
where
F is the wind load acting perpendicularly to the longitudinal axis of the member (see 5.6);
�c is the shape coefficient for the member under consideration, with reference to the wind
f
direction and the characteristic area (see 5.4). Values shall be either those given in Table 3 or
those derived by recognized theoretical or experimental methods (e.g. wind tunnel or full-scale
tests), or other recognized sources;
A is the area of solid part, i.e. the projection of the solid area of the member on to
...
ISO/TC 96/SC 10
Secretariat: DIN
Cranes — Wind load assessment
Appareils de levage à charge suspendue — EvaluationÉvaluation des charges dues au vent
© FDIS stage
All rights reserved.
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued
by ISO, an ISO member body, or an authorized third-party distributor.
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may
be reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical,
including photocopying, scanning, recording, or posting on internal or external digital platforms.
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: + 41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland.
iii
Contents
Foreword . Error! Bookmark not defined.
1 Scope . Error! Bookmark not defined.
2 Normative references . Error! Bookmark not defined.
3 Terms, definitions and symbols . Error! Bookmark not defined.
3.1 Terms and definitions . Error! Bookmark not defined.
3.2 Symbols . Error! Bookmark not defined.
4 Wind pressure . Error! Bookmark not defined.
5 In-service wind . Error! Bookmark not defined.
5.1 General . Error! Bookmark not defined.
5.2 Action of in-service wind on hoist load . Error! Bookmark not defined.
5.3 Wind load calculations . Error! Bookmark not defined.
5.4 Shape coefficients for individual members, frames, etc. . Error! Bookmark not defined.
5.5 Shielding factors — Multiple frames or members . Error! Bookmark not defined.
5.6 Wind loads on individual members (inclined to the wind direction) . Error! Bookmark not
defined.
6 Out-of-service wind . Error! Bookmark not defined.
6.1 General . Error! Bookmark not defined.
6.2 Loads due to out-of-service wind . Error! Bookmark not defined.
6.3 Equivalent static out-of-service wind pressure . Error! Bookmark not defined.
(informative) Reference storm wind speeds . Error! Bookmark not defined.
Bibliography . Error! Bookmark not defined.
iv
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types of
ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent rights
in respect thereof. As of the date of publication of this document, ISO had not received notice of (a) patent(s)
which may be required to implement this document. However, implementers are cautioned that this may not
represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 96, Cranes, Subcommittee SC 10, Design
principles and requirements.
This third edition cancels and replaces the second edition (ISO 4302:2016), which has been technically
revised.
The main changes are as follows:
— In Table 1Table 1,, all symbols applicable to this document have been added;
— The original Clause 6.4, “Wind loads on individual members (inclined to the wind direction)” has been
replaced by a requirement added at the end of Clause 5.6Clause 5.6;;
— The original Clause 6.5, “Storm wind maps” has been replaced by a generalized statement added at the end
of Clause 6.3Clause 6.3; ;
— In Annex AAnnex A,, the wind maps have been updated;
— Editorial changes have been made throughout the text.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
v
Cranes — Wind load assessment
1 Scope
This document specifies the method for determining the wind loads on cranes.
It establishes general methods for calculating wind load actions (for in-service and out-of-service conditions),
which are included in the load combinations specified in ISO 8686 series and used for proofs of competence
such as those given e.g. in ISO 20332 for the verification of structural components of cranes.
This document provides a simplified method of calculation and assumes that:
— — the wind can blow horizontally from any direction;
— — the wind blows at a constant speed;
— — there is a static reaction to the wind load applied to the crane structure.
The method takes into account the effects of gusts (fluctuations in wind speed) as well as the dynamic
behaviour (response) of the crane.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 4306--1, Cranes –— Vocabulary -— Part 1: General
3 Terms, definitions and symbols
For the purposes of this document, the terms and definitions given in ISO 4306--1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— — ISO Online browsing platform: available at https://www.iso.org/obp
— — IEC Electropedia: available at https://www.electropedia.org/
3.1 Terms and definitions
3.1.1 3.1.1
in-service wind
maximum wind that the crane is designed to withstand under operating conditions
3.1.2 3.1.2
out-of-service wind
maximum (storm) wind blowing from the least favourable direction that a crane is designed to withstand
when in an out-of-service condition
3.1.3 3.1.3
terrain-roughness coefficient
variability of the wind speed at the site of the crane due to the height above ground level and the ground
roughness of the terrain upwind of the crane structure in the wind direction considered
3.2 Symbols
Table 1 lists the symbols applicable to this document.
Table 1 — Main symbols
Symbol Description
A Area of solid part
A Enclosed area
e
AHL Reference wind area of the hoist load
Amembers Total solid area of all members across wind front
a Distance between facing sides
b Breadth of member across wind front
c , c Shape coefficients
f HL
D Diameter of a circular section
d Depth of section parallel to wind flow
F Wind load
frec Recurrence-interval factor
K Terrain-roughness coefficient
FHL Wind load due to the wind on the hoist load
l Length of member
mHL Mass of the gross or hoist load in kilograms
q In-service wind pressure
q(z) Equivalent static out-of-service wind pressure at height z
R Recurrence-interval
v 3-s-gust amplitude
g
vs Wind speed, used as a basis of the calculation
Wind speed component acting perpendicularly to the longitudinal axis or surface of a
vs*
member
v(z) Equivalent static out-of-service wind speed at the height z
Wind speed component acting perpendicularly to the longitudinal axis of a member at
v(z)*
height z
vm(z) 10-min-mean storm wind speed at height z, in metres per second
vref Reference storm wind speed
z Height above the surrounding ground level, in metres
Φ8 Gust response factor
θ Angle of the wind direction to the longitudinal axis or face (θ < 90°)
ISO/DISFDIS 4302:2026(en)
Symbol Description
η Shielding factor
η Factor for the remaining hoist load in out-of-service condition
w
ρ Density of the air
4 Wind pressure
The wind pressure q is given by Formula (1)Formula ::
𝟏𝟏 𝟏𝟏
𝟐𝟐
𝒒𝒒 = ×𝝆𝝆 ×𝒗𝒗 (1) 𝒒𝒒 = ×𝝆𝝆
𝒔𝒔
𝟐𝟐 𝟐𝟐
𝑞𝑞 = ×𝜌𝜌 ×𝑣𝑣 (1)
𝑠𝑠
where
𝜌𝜌 is the density of air which, for design purposes, is assumed to be constant 𝜌𝜌 = 1,225 kg/m ;
vs is the wind speed, used as a basis of the calculation.
When using the international system of units (SI), where 𝑞𝑞 is expressed in N/m and v in metres per second
s
(m/s), Formula (2)Formula applies:
𝑞𝑞 = 0,613 ×𝑣𝑣 (2)
𝑠𝑠
𝑞𝑞 = 0,613 ×𝑣𝑣 (2)
𝑠𝑠
5 In-service wind
5.1 General
The in-service wind load shall be determined for the specific crane configuration and operating condition,
taking into account the other load actions of the load combination under consideration.
NOTE 1 The wind load is determined such that the maximum load effect relevant for the proof of competence is
reached. It is noted that the wind direction creating the maximum wind load action usually does not coincide with the
directions of the loads from other load actions.
The in-service design wind speed (resp. design wind pressure) shall be specified based on the type of crane,
crane configuration and operating condition. Table 2 provides a selection of usual in-service design wind
speeds depending on either the type of crane or its intended use.
Table 2 — In-service design wind speeds v and pressures q
s
Design wind Design wind
speed pressure
Type of crane or application
v q
s
m/s N/m
Cranes that are easily secured against wind action and which are
designed for operation in light winds only (e.g. cranes of low chassis 14,3 125
height with booms that can be readily lowered to the ground)
All normal types of cranes installed in the open 20,2 250
Cranes in process applications, where a crane shall continue to work
28,6 500
in high winds
The wind speeds applicable to different crane configurations and for initiating securing measures shall be
specified.
NOTE 2 The in-service design wind speed given in Table 2 is based on the assumption that the crane can be fully
secured in an out-of-service configuration before this wind speed is exceeded. As the means of securing vary depending
on crane type and configuration (e.g. locking devices at specific locations along the crane runway, hand‑-operated or
automatic rail clamps, etc.), securing is in some cases initiated at a lower wind speed to allow sufficient time for the
securing procedure to be completed.
5.2 Action of in-service wind on hoist load
On all cranes, the action of the wind on the load shall be taken into account and the method by which this is
done shall be clearly described. This can be accomplished by use of wind loads on load parameters of size and
shape. The wind load 𝐹𝐹 on the load shall be calculated as a minimum in accordance with Formula (3)Formula
𝐻𝐻𝐻𝐻
)::
𝐹𝐹 =𝑐𝑐 ×𝐴𝐴 ×𝑞𝑞 (3)
𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻
𝐹𝐹 =𝑐𝑐 ×𝐴𝐴 ×𝑞𝑞
𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻
(3)
where
𝐹𝐹 is the wind load on the hoist load in the direction of the wind; see ISO 4306-1;
𝐻𝐻𝐻𝐻
𝑐𝑐 is the shape coefficient of the hoist load;
𝐻𝐻𝐻𝐻
𝐴𝐴 is the reference wind area of the hoist load;
𝐻𝐻𝐻𝐻
𝑞𝑞 is the wind pressure corresponding to appropriate design condition.
In the absence of detailed information on the composition of the hoist load, it shall be assumed that 𝑐𝑐 = 2,4
𝐻𝐻𝐻𝐻
and 𝐴𝐴 = 0,000 5 × 𝑚𝑚 , where 𝐴𝐴 is expressed in square metres (m ) and 𝑚𝑚 is the mass of the hoist load
𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻 𝐻𝐻𝐻𝐻
in kilograms (kg).
5.3 Wind load calculations
For crane structures or individual members used in crane structures, the wind load F in the direction of the
wind, is calculated from Formula (4)Formula ::
𝐹𝐹 =𝑐𝑐 ×𝐴𝐴 ×𝑞𝑞 (4)
𝑓𝑓
𝐹𝐹 =𝑐𝑐 ×𝐴𝐴 ×𝑞𝑞
𝑓𝑓
(4)
where
𝐹𝐹 is the wind load acting perpendicularly to the longitudinal axis of the member (see 5.6);
𝑐𝑐 is the shape coefficient for the member under consideration, with reference to the wind direction and the
𝑓𝑓
characteristic area (see 5.4). Values shall be either those given in Table 3 or those derived by recognized theoretical or
experimental methods (e.g. wind tunnel or full-scale tests), or other recognized sources;
𝐴𝐴 is the area of solid part, i.e. the projection of the solid area of the member on to a plane perpendicular to the wind
direction;
𝑞𝑞 is the wind pressure corresponding to appropriate design condition.
The total wind load on the structure is taken as the sum of the loads on its members.
ISO/DISFDIS 4302:2026(en)
5.4 Shape coefficients for individual members, frames, etc.
Shape coefficients 𝑐𝑐 for individual members, single lattice frames, and machinery houses, etc. vary according
𝑓𝑓
to the aerodynamic slenderness and, in the case of large box sections, with the section ratio. Aerodynamic
slenderness and section ratio are defined in Figure 1.
Field Code Changed
Where a frame is made up of flat-sided and circular sections, or of circular sections in both flow regimes
2 2
(D × v < 6 m /s and D × v ≥ 6 m /s), the appropriate shape coefficients are applied to the corresponding
s s
frontal areas.
Table — Shape coefficients 𝒄𝒄𝒄𝒄 per aerodynamic slenderness
𝒇𝒇 𝒇𝒇
Aerodynamic slenderness l/b or l/D
(see Figure 1Figure 1))
Type Description
5 10 20 30 40 50
Individual Rolled sections, rectangles, hollow sections, flat
1,3 1,35 1,6 1,65 1,7 1,9
members plates
Circular sections where D × vs < 6 m /s 0,75 0,80 0,90 0,95 1,0 1,1
Circular sections where D × vs ≥ 6 m /s 0,60 0,65 0,70 0,70 0,75 0,8
b/d
≥ 2 1,55 1,75 1,95 2,1 2,2
Box sections over 350 mm square and
1 1,40 1,55 1,75 1,85 1,9
250 mm, 450 mm rectangular
0,5 1,0 1,2 1,3 1,35 1,4
0,25 0,8 0,9 0,9 1,0 1,0
Single lattice Flat sided sections 1,7
frames
Circular sections where D × v < 6 m /s 1,2
s
Circular sections where D × vs ≥ 6 m /s 0,8
Machinery Rectangular clad structures on ground or solid base
1,1
houses, etc. (air flow beneath structure prevented)
Key
𝑙𝑙 length of member
b breadth of section across wind front
d depth of section parallel to wind flow
D diameter of a circular section in metres
v design wind speed in metres per second
s
Key
1 wind direction
l length of member
b breadth of section across wind front
d depth of section parallel to wind flow
D diameter of a circular section in metres
Figure 1 — Aerodynamic slenderness and section ratio
5.5 Shielding factors — Multiple frames or members
Where parallel frames or members are positioned so that shielding takes place, the wind load on the windward
frame or member and on the unsheltered parts of those behind it are calculated using the appropriate shape
coefficients. The shape coefficients on the sheltered parts are multiplied by a shielding factor η given in
Table 4. Values of η vary with the solidity and spacing ratios as defined in Figure 2.
Table 4 — Shielding factors (η)
Solidity ratio A/Ae
Spacing ratio
(see Figure 2Figure 2))
a/b
0,
...