IEC 80601-2-60:2019/FDAmd 1 - Medical electrical equipment — Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment — Amendment 1

Release Date:12-Nov-2026
English language (11 pages)
sale 15% off
sale 15% off

IEC 80601-2-60:2019/FDAM 1 is an IEC amendment, prepared with ISO/TC 106/SC 6, for medical electrical equipment used as dental equipment. It updates the particular requirements for basic safety and essential performance in the dental setting, with changes that affect definitions, insulation, temperature testing, marking, and selected references used by manufacturers, test laboratories, and certification bodies.

What does IEC 80601-2-60:2019/FDAM 1 specify?

IEC 80601-2-60:2019/FDAM 1 revises selected requirements in the dental equipment part of IEC 80601. The amendment concentrates on Clause 201 and Annex AA, which gives the rationale behind the technical choices.

AnnexWhat it covers
AAInformative guidance and rationale for essential performance, marking, applied parts, insulation coordination, and temperature measurement

In practice, the amendment is about how dental equipment is defined, how it is insulated and tested, how hot parts are checked, and how some accessories are treated during safety evaluation.

What are the key requirements of IEC 80601-2-60:2019/FDAM 1?

IEC 80601-2-60:2019/FDAM 1 changes the technical rules that matter most for design review, testing, and risk management. The main effect is to align the dental-specific requirements with updated insulation, temperature and reference standards.

Definitions and performance

  • 201.3 updates the definitions of DENTAL ELECTRICAL MOTOR, DENTAL EQUIPMENT, DENTAL HANDPIECE, and PATIENT SIDE OF DENTAL HANDPIECE. This matters because the safety rules apply differently depending on whether a device is treated as a handpiece, motor, or broader dental system.
  • 201.4.3 states that DENTAL EQUIPMENT has no ESSENTIAL PERFORMANCE unless the MANUFACTURER specifies it. In practice, manufacturers need to justify any clinical function they treat as essential.

Marking and applied parts

  • 201.7.2.11 and 201.7.2.12 remove marking requirements for DENTAL HANDPIECES, DENTAL ELECTRICAL MOTORS, and their power switches. This reduces labeling burden where the parts are too small or not visible in use.
  • 201.8.5.2.101 allows several APPLIED PARTS to be treated as one only when no HAZARDOUS SITUATION is created by separate or combined use. The general standard still applies for patient leakage current and insulation, so the combined design must still be safe under realistic use.

Insulation and separation

  • 201.8.9.1.2, 201.8.9.1.8, 201.8.9.1.11, 201.8.9.1.12, 201.8.9.2 and 201.8.9.4 update creepage and air-clearance rules using IEC 60664-1:2020, IEC 60664-4:2005 and, where relevant, IEC 62368-1. Designers need to check mains separation, secondary circuits, pollution degree, frequency range, and separation devices against the updated rules, not only against the general standard.
  • These provisions also emphasize selecting the more demanding insulation value where two references apply. In practice, that affects enclosure layout, PCB spacing, relay choice and verification testing.

Temperature and liquid ingress

  • 201.11.1.1, 201.11.1.2.2.101 and 201.11.1.3 update temperature checks for dental handpieces and electrically powered scalers under normal use and reasonably foreseeable misuse. This means manufacturers must test the hottest parts under the operating conditions defined in the clause and compare them with the applicable temperature limits.
  • 201.15.4.7.3 adds a note on liquids in dental practices. It links floor-level liquid exposure to the RISK MANAGEMENT FILE, so the environment assessment must be documented.

Other safety changes

  • 201.10 removes the general standard's radiation hazard clause from this particular standard. That means the dental-specific document no longer applies that clause as part of this particular standard.

What terms does IEC 80601-2-60:2019/FDAM 1 define?

  • DENTAL EQUIPMENT - medical electrical equipment alone or combined with dental handpieces, units, chairs, operating lights, or intraoral sensors, so the scope includes complete treatment systems and some related devices.
  • DENTAL HANDPIECE - a hand-held instrument used in dentistry for patient treatment and connected to a dental unit or internal power source, which places it directly under the patient-contact safety rules.
  • DENTAL ELECTRICAL MOTOR - the hand-held powered part of a dental handpiece, which matters because motor and handpiece marking and insulation are treated separately.
  • PATIENT SIDE OF DENTAL HANDPIECE - the part intended for insertion into the oral cavity, which is important for reprocessing and applied-part classification.
  • ESSENTIAL PERFORMANCE - the performance of a clinical function whose loss or degradation would create unacceptable risk; Annex AA explains that physical hazards are excluded from this concept.
  • APPLIED PART - the part of equipment that is intended to contact the patient, which is central to leakage-current and insulation checks.
  • MOPP (Means Of Protection of Patient) - the insulation and separation concept used to protect the patient from mains-related hazards.

Who uses IEC 80601-2-60:2019/FDAM 1?

IEC 80601-2-60:2019/FDAM 1 is used by manufacturers of dental equipment, especially makers of handpieces, motors, dental units, chairs, operating lights, scalers and intraoral sensors. It is also used by electrical safety engineers, EMC and test laboratories, quality managers, certification bodies and risk-management teams.

They use it to decide how to classify parts, how to design insulation and separation, how to set up temperature tests, and how to document risk-based decisions for dental products.

What changed in IEC 80601-2-60:2019/FDAM 1 from the previous edition?

IEC 80601-2-60:2019/FDAM 1 changes the base dental standard by:

  • updating the definitions for dental equipment, handpieces, motors and the patient side of the handpiece
  • stating that dental equipment has no essential performance unless the manufacturer specifies it
  • removing marking requirements for dental handpieces, dental electrical motors and their power switches
  • tightening the rule for combining applied parts into one applied part
  • updating creepage, air-clearance and separation-device rules to newer insulation references
  • revising temperature testing for handpieces and electrically powered scalers
  • removing Clause 10 on radiation hazards from the general standard
  • adding a note on liquids in dental practices
  • expanding Annex AA rationale and updating the bibliography

Which standards are used with IEC 80601-2-60:2019/FDAM 1?

StandardWhat it contributes
IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012, IEC 60601-1:2005/AMD2:2020General medical electrical safety and essential performance baseline
IEC 60601-2-2:2017, IEC 60601-2-2:2017/AMD1:2023Related particular requirements used in the references
IEC 60664-1:2020Creepage distances, air clearances, pollution degree and overvoltage coordination
IEC 60664-4:2005Insulation coordination for higher frequencies
IEC 61810-1:2015, IEC 61810-1:2015/AMD1:2019Relays and encapsulated separation devices
IEC 62368-1:2018Alternative safety reference used in the insulation discussion
ISO 1942Dentistry vocabulary
ISO 14971:2019Risk management basis in Annex AA
ISO 18397:2025Context for powered scaler temperature discussion in Annex AA

What does the IEC 80601-2-60:2019/FDAM 1 document contain?

IEC 80601-2-60:2019/FDAM 1 contains revised clause text, updated references, and an informative annex that explains the rationale behind the changes. The technical content focuses on insulation coordination, applied-part grouping, temperature testing, and the treatment of dental handpieces and motors.

Annex AA adds guidance on how to interpret essential performance, why some markings are waived, and how to think about hazard scenarios during use. It also includes explanatory material for scaler temperature behavior and insulation examples, which helps laboratories and manufacturers apply the clause text consistently.

Relations

Effective Date
24-Feb-2024

Buy Documents

Draft

IEC 80601-2-60:2019/FDAmd 1 - Medical electrical equipment — Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment — Amendment 1

Release Date:12-Nov-2026
English language (11 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

IEC 80601-2-60:2019/FDAmd 1 is a draft published by the International Organization for Standardization (ISO). Its full title is "Medical electrical equipment — Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment — Amendment 1". This standard covers: Medical electrical equipment — Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment — Amendment 1

Medical electrical equipment — Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment — Amendment 1

IEC 80601-2-60:2019/FDAmd 1 is classified under the following ICS (International Classification for Standards) categories: 11.060.20 - Dental equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 80601-2-60:2019/FDAmd 1 has the following relationships with other standards: It is inter standard links to IEC 80601-2-60:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 80601-2-60:2019/FDAmd 1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • FOREWORD
  • Annex AA (informative) Particular guidance and rationale
  • Bibliography

FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies.

6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a) patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which may be required to implement this document. However, implementers are cautioned that this may not represent the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC shall not be held responsible for identifying any or all such patent rights. Amendment 1 to IEC 80601-2-60:2019 has been prepared by subcommittee 62D: Particular medical equipment, software, and systems, of IEC technical committee 62: Medical equipment, software, and systems, and subcommittee 6: Dental equipment, of ISO technical committee 106:

Dentistry.

The text of this Amendment is based on the following documents:

Draft Report on voting 62D/XX/FDIS 62D/XX/RVD Full information on the voting for its approval can be found in the report on voting indicated in the above table.

The language used for the development of this Amendment is English. This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are described in greater detail at www.iec.ch/publications/.

The committee has decided that the contents of this document will remain unchanged until the stability date indicated on the IEC website under webstore.iec.ch in the data related to the specific document. At this date, the document will be - reconfirmed, - withdrawn, or - revised.

201.1.4 Particular standards Replace the existing third paragraph with the following:

For brevity, IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020 are referred to in this particular standard as the general standard. Collateral standards are referred to by their document number. 201.2 Normative references Delete the existing references to IEC 60825-1:2014, as well as "Replacement:", and IEC 60601-2-22:2007 and to its amendment.

Add the following normative reference to the list:

IEC 62368-1:2018, Audio/video, information and communication technology equipment - Part 1:

Safety requirements Replace the existing references to IEC 60601-2-2:2017, IEC 60664-1:2007, IEC 61810-1:2015 and ISO 1942 by the following new references:

IEC 60601-2-2:2017, Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories IEC 60601-2-2:2017/AMD1:2023 IEC 60664-1:2020, Insulation coordination for equipment within low-voltage systems - Part 1:

Principles, requirements and tests IEC 61810-1:2015, Electromechanical elementary relays - Part 1: General and safety requirements IEC 61810-1:2015/AMD1:2019 ISO 1942, Dentistry - Vocabulary

This publication was withdrawn and replaced with IEC 62368-1:2023.

201.3.201 DENTAL ELECTRICAL MOTOR Replace the existing definition with the following new definition:

HAND-HELD part of the DENTAL HANDPIECE electrically powered by the DENTAL UNIT or internal power source 201.3.202 DENTAL EQUIPMENT Replace the existing definition with the following new definition and new Note 1 to entry:

ME EQUIPMENT alone or with any combination of DENTAL HANDPIECES, DENTAL UNITS, DENTAL PATIENT CHAIRS, DENTAL OPERATING LIGHTS and intraoral sensors Note 1 to entry: Devices like dental X-ray sensors and apex locators are DENTAL EQUIPMENT. 201.3.203 DENTAL HANDPIECE Replace the existing definition with the following new definition:

HAND-HELD instrument used in dentistry for use in PATIENT treatment, connected to the DENTAL UNIT or internal power source 201.3.208 PATIENT SIDE OF DENTAL HANDPIECE Replace the existing definition with the following new definition and new Note 1 to entry:

part of DENTAL HANDPIECE which is designed to be introduced into the oral cavity where all parts of the DENTAL HANDPIECE within 80 mm of the tip are considered as an APPLIED PART Note 1 to entry: This dimension relates to reprocessing classification. 201.4.3 ESSENTIAL PERFORMANCE Replace the existing title and text with the following new title and text:

201.4.3 * ESSENTIAL PERFORMANCE Addition:

DENTAL EQUIPMENT does not have ESSENTIAL PERFORMANCE, unless specified by the MANUFACTURER.

201.7.2.11 * Mode of operation Replace the existing text with the following new text:

Addition:

For DENTAL HANDPIECES, marking is not required.

For DENTAL ELECTRICAL MOTORS, marking is not required.

Add, after the existing Subclause 201.7.2.11, the following new subclause and new text:

201.7.2.12 * Power switches Addition:

Marking is not required for switches used to activate or control DENTAL HANDPIECES and DENTAL ELECTRICAL MOTORS.

201.8.5.2.101 * APPLIED PARTS that form one single APPLIED PART Replace the existing second paragraph of this subclause with the following new paragraph and new examples:

The combination of several APPLIED PARTS to form one single APPLIED PART is only permitted if no HAZARDOUS SITUATION occurs when individually applying any of the several APPLIED PARTS or when concurrently applying any combination of the several APPLIED PARTS. Requirements for patient leakage current and insulation according to the general standard apply. EXAMPLE 1 For a dual motor controller system with two dental motors or DENTAL HANDPIECES, consideration is given to a potential HAZARDOUS SITUATION in which an OPERATOR is using one handpiece and the assistant is changing the bur in the other handpiece.

EXAMPLE 2 For an apex locator system, consideration is given to a potential HAZARDOUS SITUATION in which the apex lip clip is in contact with a patient and an OPERATOR is changing out the file in the handpiece associated with the apex locator system.

EXAMPLE 3 For two handpieces powered out of the same floating circuit, consideration is given to a potential HAZARDOUS SITUATION in which one handpiece is in use and the other is touched by an OPERATOR, even when it is inactive in a holder. (See Annex AA, 201.8.5.2.101) 201.8.9.1.2 CREEPAGE DISTANCES and AIR CLEARANCES complying with IEC 60950-1 Replace the existing title and text of this subclause with the following new title and text:

...