ISO 4259-2:2026
(Main)Petroleum and related products — Precision of measurement methods and results — Part 2: Interpretation and application of precision data in relation to methods of test
- Abstract
This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures. The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products. This document is not applicable to non-homogenous products.
- Status
- Published
- Publication Date
- 08-Jun-2026
- Current Stage
- 6060 - International Standard published - 60 Publication
- Start Date
- 09-Jun-2026
- Due Date
- 14-Feb-2027
- Completion Date
- 14-Feb-2027
Buy Documents
ISO 4259-2:2026 - Petroleum and related products — Precision of measurement methods and results — Part 2: Interpretation and application of precision data in relation to methods of test
ISO 4259-2:2026 - Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 2: Interprétation et application des valeurs de fidélité relatives aux méthodes d'essai
ISO 4259-2:2026 is an International Standard from ISO for petroleum and related products. It explains how to apply precision data from a test method to set specification limits, judge whether results agree, and decide conformance when supplier and recipient results conflict.
It is aimed at people who write specifications, run test laboratories, or make release and acceptance decisions for products tested by a specific method.
What does ISO 4259-2:2026 specify?
ISO 4259-2:2026 specifies how to use precision estimates derived from ISO 4259-1 when a property is measured by a defined test method. The standard focuses on two practical tasks: setting specification limits so they fit the test method precision, and deciding whether a product conforms when supplier and recipient results disagree.
The procedures are written for petroleum and petroleum-related products, which are normally homogeneous, and they can also be applied to other homogeneous products. The document is organized into clauses on repeatability and reproducibility, specification setting, conformance assessment, and dispute handling, followed by two annexes.
| Annex | What it covers |
|---|---|
| Annex A | Explanation of the formulae used in Clause 4 |
| Annex B | Normative dispute resolution procedure for specifications based on a specified degree of criticality |
What are the key requirements of ISO 4259-2:2026?
ISO 4259-2:2026 makes test-method precision part of the decision process. In practice, that means the laboratory result is not used alone - it is checked against repeatability or reproducibility limits, and the specification itself must be consistent with the precision of the method.
Applying repeatability and reproducibility
Clause 4 states that repeatability, r, and reproducibility, R, are estimated from an inter-laboratory programme and published with the test method. For routine work, a set of repeated results from one laboratory is checked against repeatability first, and results that are too far apart are investigated and, if needed, rejected before averaging. This matters because it gives the operator a structured way to decide whether a set of repeat results is usable.
Clause 4 also uses reproducibility to compare results from different laboratories. If the difference between laboratories stays within the reproducibility limit, the results are treated as acceptable and averaged. If they do not agree, more results are taken and the comparison is repeated, which helps prevent a single outlying result from driving a release or rejection decision.
Using confidence limits
Clause 4 gives confidence-limit calculations for results obtained under repeatability conditions and under reproducibility conditions. In practice, these limits tell the user how much uncertainty remains around the measured value when only a small number of results is available. The standard also explains how a single result can be treated when only an upper or lower limit is fixed.
Clause 4.4 extends the use of reproducibility to compare two different test methods that claim to measure the same property. The method is intended to show whether a constant bias correction would improve agreement for a given material. That is useful when a company wants to understand whether two approved test methods are effectively aligned for the same product.
Setting specification limits
Clause 5 requires specification limits to stay within the scope limits of the test method defined in ISO 4259-1. It also requires the range between lower and upper specification limits to be compatible with the method precision. The practical point is that a specification should not demand more certainty than the test method can support.
Clause 5 distinguishes between double limits and single limits. It also warns that if the specification band is too narrow compared with the method precision, the test result may have doubtful value for deciding pass or fail. In that case, the user should either widen the specification or look for a more precise test method.
Assessing conformance
Clause 6 explains how supplier and recipient judge conformance to specification. Before results are used, the laboratory must show that the test method is in statistical control, that its site precision is within the published method performance, and that the laboratory has demonstrated proficiency, for example through PTS participation or a CRM result.
For a supplier, a single result can support release only when it lies far enough inside the specification limit to give 95% confidence. With multiple repeatability results, the supplier uses the average of acceptable results and the repeatability checks from Clause 4. For a recipient, the same logic is used in reverse: a single result can justify a non-conformance decision only when it lies far enough beyond the limit to support 95% confidence.
Clause 6.3 also addresses repeated results over multiple batches. Persistent results just beyond the specification limit can indicate that the supplier’s confidence level is weaker than intended. For a buyer, that is a signal to discuss release practice and sampling history with the supplier before treating the product as off-specification.
Handling disputes
Clause 7 sets out the dispute procedure when supplier and recipient do not agree. The first step is negotiation, and the standard expects a common adjudication sample to be available. If the dispute continues, each laboratory discards its original results, retests under repeatability conditions, and compares the averages using the reproducibility-based decision process.
If the disagreement still remains, the laboratories compare their operating procedures and apparatus, and a neutral third-party laboratory may be added. The final decision is then based on the agreed adjudication samples and the comparison rules in Clause 7. Annex B provides an alternative dispute route when the parties have agreed a degree of criticality in advance.
What terms does ISO 4259-2:2026 define?
- proficiency testing scheme (PTS) - A programme used to check laboratory testing capability for a standard test method by analysing results from aliquots of a single homogeneous batch.
- recipient - The individual or organization that receives or accepts the product from the supplier.
- supplier - The individual or organization responsible for product quality just before the product is taken over by the recipient.
- repeatability, r - The agreement expected among results obtained under repeatability conditions in one laboratory.
- reproducibility, R - The agreement expected among results obtained in different laboratories under reproducibility conditions.
- Statistical Quality Control (SQC) - The in-house charting or equivalent statistical control used to show that a laboratory’s method is in control.
- CRM - A certified reference material used to demonstrate proficiency when a suitable PTS is not available.
Who uses ISO 4259-2:2026?
ISO 4259-2:2026 is used by testing laboratories, quality managers, specification writers, and commercial teams in the petroleum and related products sector. Suppliers use it when deciding whether to release product, and recipients use it when checking delivered product against contract limits.
It is also relevant to technical committees and method developers because it links method precision to specification setting. Proficiency testing providers and laboratories participating in PTS also use it to understand how published precision data affects practical decisions.
What changed in ISO 4259-2:2026 from the previous edition?
ISO 4259-2:2026 is the second edition and replaces ISO 4259-2:2017. It also incorporates ISO 4259-2:2017/Amd. 1:2019.
The main changes stated in the foreword are:
- inclusion of normative references to ISO 4259-3 and ISO 4259-4
- modification of Figures 1, 2 and 3
- deletion of former Annex C because its content is covered by ISO 4259-4
Which standards are used with ISO 4259-2:2026?
| Standard | How it contributes |
|---|---|
| ISO 4259-1:2026 | Provides the determination of precision data, variables, and the scope limits used when setting specifications |
| ISO 4259-3 | Provides monitoring and verification of published precision data and supports checking bias through PTS |
| ISO 4259-4 | Provides the use of statistical control charts to verify that a laboratory is in statistical control |
| ISO 4259-5 | Gives the general approach to agreement between two different test methods that claim to measure the same property |
What does the ISO 4259-2:2026 document contain?
ISO 4259-2:2026 contains the procedures, formulae, and decision logic behind precision-based specification setting and conformance assessment. Clause 4 covers repeatability and reproducibility, Clause 5 covers how specification limits are constructed, Clause 6 covers supplier and recipient conformance decisions, and Clause 7 covers disputes.
The document also includes Figure 1 for specification setting, Figure 2 for recipient conformance, and Figure 3 for dispute handling. Annex A explains the statistical reasoning behind the formulae in Clause 4 and includes a table of normal-distribution critical values. Annex B gives a normative alternate dispute procedure for critical specifications, and the worked examples in Clauses 6 and 7 show how the rules are applied in practice using petroleum test data.
Relations
- Effective Date
- 12-Feb-2026
- Effective Date
- 17-Feb-2024
- Effective Date
- 17-Feb-2024
Buy Documents
ISO 4259-2:2026 - Petroleum and related products — Precision of measurement methods and results — Part 2: Interpretation and application of precision data in relation to methods of test
ISO 4259-2:2026 - Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 2: Interprétation et application des valeurs de fidélité relatives aux méthodes d'essai
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.
ABS Group Brazil
ABS Group certification services in Brazil.

ABS Quality Evaluations Inc.
American Bureau of Shipping quality certification.
Sponsored listings
Frequently Asked Questions
ISO 4259-2:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Petroleum and related products — Precision of measurement methods and results — Part 2: Interpretation and application of precision data in relation to methods of test". This standard covers: This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures. The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products. This document is not applicable to non-homogenous products.
This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures. The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products. This document is not applicable to non-homogenous products.
ISO 4259-2:2026 is classified under the following ICS (International Classification for Standards) categories: 75.080 - Petroleum products in general. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 4259-2:2026 has the following relationships with other standards: It is inter standard links to EN ISO 4259-2:2026, ISO 4259-2:2017/Amd 1:2019, ISO 4259-2:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 4259-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 proficiency testing scheme
- 3.2 recipient
- 3.3 supplier
- 4 Application and significance of repeatability, r, and reproducibility, R
- 4.1 General
- 4.2 Repeatability, r
- 4.3 Reproducibility, R
- 4.4 Use of reproducibility to determine bias between two different test methods that
- 5 Specifications
- 5.1 Aim of specifications
- 5.2 Construction of specifications limits in relation to scope and precision of the specified
- 6 Assessment of quality conformance to specifications
- 6.1 General
- 6.2 Assessment of quality conformance by the supplier
- 6.3 Assessment of quality conformance by the recipient
- 7 Dispute procedure
- 7.1 Resolve dispute by negotiation
- 7.2 Use of the test method or procedure in case of dispute
- 7.3 Dispute resolution procedure
- 7.4 Dispute unresolved
- 7.5 Example of a dispute resolution
- Annex A
- 1 N 2N 1 N
- Annex B
- Bibliography
Introduction
For the purposes of setting product specifications and checking product conformity against these specifications, standard test methods are usually referenced for specific properties of commercial petroleum and related products. Two or more measurements of the same property of a specific sample by a specific test method, or by different test methods that purport to measure the same property, will not usually give exactly the same result. It is therefore necessary to take proper account of this fact when setting product specifications, assessing if the differences between test results are within statistical expectation, and making specification compliance decisions based on limited test results. By using statistically-based estimates of the precision for a test method, the following can be achieved:
- an objective measure of the reliability of specification limits,
- a specification compliance decision,
- the degree of agreement expected between two or more results obtained in specified circumstances. This document describes the applications of the precision of test methods as derived from ISO 4259-1. It is intended to be used in conjunction with the other parts of ISO 4259 series to provide additional guidance on the application of precision estimates. ISO 4259-3 specifies how to use the precision to assess capability via proficiency testing and ISO 4259-4 specifies how to use this precision to assess the “in statistical control” status and precision capability of a specific laboratory in the execution of a test method. Furthermore, ISO 4259-5 specifies the general approach to the agreement between two different test methods that purport to measure the same property.
ISO 4259-1 and this document encompass both the determination of precision estimates and the application [1] of precision data. The principles within the documents attempt to be aligned with ASTM D6300 regarding [2] the determination of the precision estimates and with ASTM D3244 for the utilization of test data. A glossary of the variables used in this document is included in ISO 4259-1:2026, Annex I.
International Standard ISO 4259-2:2026(en) Petroleum and related products — Precision of measurement methods and results — Part 2:
Interpretation and application of precision data in relation to methods of test
1 Scope
This document specifies the methodology for applying precision estimates of a test method derived from the processes specified in ISO 4259-1. In particular, it specifies the procedures for setting the property specification limits based upon test method precision where the property is determined using a specific test method, and determines the specification conformance status when there are conflicting results between supplier and receiver. Other applications of this test method precision are briefly described in principle without the associated procedures.
The procedures in this document have been designed specifically for petroleum and petroleum-related products, which are normally homogeneous. However, the procedures described in this document can also be applied to other types of homogeneous products.
This document is not applicable to non-homogenous products.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 4259-1:2026, Petroleum and related products — Precision of measurement methods and results — Part 1:
Determination of precision data in relation to methods of test ISO 4259-3, Petroleum and related products — Precision of measurement methods and results — Part 3:
Monitoring and verification of published precision data in relation to methods of test ISO 4259-4, Petroleum and related products — Precision of measurement methods and results — Part 4: Use of statistical control charts to validate 'in-statistical-control' status for the execution of a standard test method in a single laboratory
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 4259-1 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
ISO 4259-2:2026(en)
3.1 proficiency testing scheme
PTS programme designed for the periodic evaluation of participating laboratories’ testing capability of a standard test method through the statistical analysis of their test results obtained on aliquots prepared from a single batch of homogeneous material Note 1 to entry: The frequency of such testing varies according to the programme objective. Each execution of testing involves testing of a single batch of material. Materials typically vary from test to test. Note 2 to entry: This is also commonly referred to as the Interlaboratory Cross Check Program (ILCP).
3.2 recipient
individual or organization who receives or accepts a product delivered by the supplier (3.3)
3.3 supplier
individual or organization responsible for the quality of a product just before it is taken over by the recipient (3.2)
4 Application and significance of repeatability, r, and reproducibility, R
4.1 General
The value of these quantities is estimated from analysis of variance (two-factor with replication) performed on the results obtained in a statistically designed inter-laboratory programme in which different laboratories each test a range of samples. Repeatability and reproducibility values estimated in accordance with ISO 4259-1 shall be included in each published test method. NOTE 1 See Annex A for an account of the statistical reasoning underlying the formulae in Clause 4. NOTE 2 Other equivalent statistical techniques can also be used for these estimations. In 4.2 to 4.4, it is assumed that the result(s) are obtained from a test method that is "in statistical control" and “no statistical evidence of systemic bias” vs industry. For determination of "in statistical control", see ISO 4259-4 and for determination of “no statistical evidence of systemic bias” vs industry, see ISO 4259-3.
4.2 Repeatability, r
4.2.1 General
Most laboratories do not carry out more than one test on each sample for routine quality control purposes except in some circumstances, such as in cases of dispute or if the test operator wishes to confirm that the technique used is satisfactory. In such circumstances, when multiple results are obtained, it is useful to check the consistency of repeated results against the repeatability of the method. The appropriate procedure is outlined in 4.2.2. It is also useful to know what degree of confidence can be placed on the average results; see 4.2.3 for the method of determining this.
4.2.2 Acceptability of results
When only two results are obtained under repeatability conditions and their difference is less than or equal to r, the test operator can consider their work as being under control and may take the average of the two results as the estimated value of the property being tested.
If the two results differ by more than r, both shall be considered as suspect and at least three more results obtained. Including the first two, the difference between the most divergent result and the average of the
ISO 4259-2:2026(en) remainder shall then be calculated and this difference compared with a new value, r , instead of r, given in
Formula (1):
k rr�� � (1)
21k
where k is the total number of results obtained.
If the difference is less than or equal to r , all the results shall be accepted. If the difference exceeds r , 1 1 the most divergent result shall be rejected and the procedure specified in this subclause repeated until an acceptable set of results is obtained.
The average of the acceptable results shall be taken as the estimated value of the property. However, if two or more results from a total of not more than 20 have been rejected, the operating procedure and the apparatus shall be checked and a new series of tests made.
4.2.3 Confidence limits calculations using results collected under repeatability conditions
When a single test operator, who is working within the precision limits of the method, obtains a series of k results under repeatability conditions, giving an average, X , and the results meet the repeatability requirement in 4.2.2, it can be assumed with 95 % confidence that the true value, μ, of the characteristic lies within the following limits, given in Formula (2):
R R
X X (2)
22 Where R is defined in Formula (3):
1
R 1 (3) Rr
k
When k = 1, uses the single test result as the value for the X term in Formula (4):
R R X X (4)
22 where R is the published test method reproducibility as discussed in 4.3. Similarly, for the single limit situation, when only one limit is fixed (upper or lower), it can be assumed with 95 % confidence that the true value, μ, of the characteristic is limited as follows for an upper limit Formula (5):
XR05, 9 (5)
Or lower limit in Formula (6) XR05, 9 (6)
0,84 The factor 0,59 is the ratio , where 0,84 is derived from Annex A.
When r is much smaller than R, little improvement in the precision of the average is obtained by carrying out multiple testing under repeatability conditions.
ISO 4259-2:2026(en)
4.3 Reproducibility, R
4.3.1 Acceptability of results
The procedure specified in this subclause is intended for judging the acceptability, with respect to the reproducibility of the test method, of results obtained by different laboratories in normal, day-to-day operations and transactions. In cases of dispute between a supplier and a recipient, the procedure specified in Clauses 5 to 7 shall be adopted.
When single results are obtained in two laboratories and their difference is less than or equal to R, the two results shall be considered as acceptable, and used to calculate the average X . The average X , rather than either single result separately, shall be used as the estimated value of the tested property. The true value, μ, of the characteristic is contained within the following limits with a 95 % confidence:
RR XX (7)
Similarly, for the single limit situation, when only one limit is fixed (upper or lower), the true value, μ, of the characteristic is contained with the following limits with a 95 % confidence. For an upper limit, see Formula (8):
XR04, 2 (8)
or lower limit, see Formula (9):
XR04, 2 (9)
05, 9 The factor 0,42 is the ratio of as it is an average of two results.
If the two results differ by more than R, both shall be considered as suspect. Each laboratory shall then obtain at least three other acceptable results (see 4.2.2).
In this case, the difference between the averages of all acceptable results of each laboratory shall be judged for conformity using a new value, R , instead of R, as given by Formula (10):
1 1
R 1 (10) Rr
2 2 kk 12 where R is the reproducibility of the method; r is the repeatability of the method; k is the number of results of the first laboratory;
k is the number of results of the second laboratory.
If the difference between the averages is less than or equal to R , then these averages are acceptable and
their overall average shall be considered as the estimated value of the tested property. If the difference between the averages is greater than R , and there is a dispute on the specification conformance of the
tested property, then the procedure specified in Clause 7 shall be adopted. If circumstances arise in which there are more than two laboratories, each supplying one or more acceptable results, the difference between the most divergent laboratory average and the average of the remaining N laboratory averages shall be compared to R :
ISO 4259-2:2026(en) where 2 2 RR 1 4 R (11)
22N
r 11 1
RR N (12)
N kk k
12 N R is given in Formula (3), and corresponds to the most divergent laboratory average.
If this difference is equal to or less than R in absolute value, all results shall be regarded as acceptable and
their average taken as the estimated value of the property.
If the difference is greater than R , the most divergent laboratory average shall be rejected and the
comparison using Formulae (11) and (12) repeated until an acceptable set of laboratory averages is obtained. The average of these laboratory averages shall be taken as the estimated value of the property. However, if two or more laboratory averages from a total of not more than 20 have been rejected, the operating procedure and the apparatus shall be checked and a new series of tests made.
4.3.2 Confidence limits calculations using results collected under reproducibility conditions
When N laboratories obtain one or more results under conditions of repeatability and reproducibility, giving an average of laboratory averages X , the true value μ of the characteristic is contained within the following limits with 95 % confidence:
R R
XX (13) 22N N Similarly, for the single limit situation, when only one limit is fixed (upper or lower), the true value μ of the characteristic is contained with the following limits with 95 % confidence for an upper limit in Formula (14):
R
X 05, 9 (14)
N
Or lower limit in Formula (15) R
X 05, 9 (15)
N
4.4 Use of reproducibility to determine bias between two different test methods that
purport to measure the same property
4.4.1 General
For the situation where two different test methods purport to measure the same property, the reproducibility estimates (R) from the respective test methods shall be used in conjunction with the averages obtained from multiple laboratories for the same material to determine if a bias correction can be applied to improve statistically the agreement between the two methods for that material. For example, results collected through proficiency testing schemes (PTS) for different test methods using the same sample can be analysed in this fashion.
NOTE Discussion on methodology for this type of assessment for the simultaneous analysis of multiple materials/ property levels that span the intersecting scope of two different test methods is beyond the scope of this document. [3] Interested readers are encouraged to consult ISO 4259-5 for further information on the subject.
ISO 4259-2:2026(en)
4.4.2 Process
Assume that test method A and test method B are test methods that purport to measure property C. Calculate the following statistic:
YY AB Z (16)
R R A B
7,,683L 7 683L A B where Y is the average from L results for property C for a material using test method A, where each A A result is a single result obtained under reproducibility conditions; L is the total number of laboratories (results) for test method A and should be > 20; A R is the reproducibility of test method A; A Y is the average from L results for property C for a material using test method B on the same B B material tested by test method A, where each result is a single result obtained under reproducibility conditions; L is the total number of laboratories (results) for test method B, and should be > 20; B R is the reproducibility of test method B.
B If Z > 2, it shall be concluded, with 95 % confidence, that a constant bias correction statistically improves the degree of agreement between test method A and test method B for property C for this material.
5 Specifications
5.1 Aim of specifications
The purpose of a specification is to specify an acceptable limit or limits to the true value, μ, of the property as determined by a specified test method. In practice, however, this true value can never be established exactly since the results obtained by applying the specified test method in a single or multiple laboratories can show acceptable scattering as specified by the repeatability and reproducibility. There is, therefore, always some uncertainty as to the true value of the tested property determined from a finite number of test results. Petroleum product compliance with specifications is assessed in accordance with Clauses 6 and 7. By prior agreement, a supplier and recipient may use the alternative procedures described in Annex B. WARNING — It is important that the test method specified for the determination of the property governed by the specification limit(s) is sufficiently precise to reliably determine whether or not the product meets the specifications.
5.2 Construction of specifications limits in relation to scope and precision of the specified
test method The specification limits shall not be outside the method scope limits as determined in ISO 4259-1. The lower specification limit shall not be less than the lower scope limit of the test method, and the upper specification limit shall not be greater than the upper scope limit of the test method (as specified in ISO 4259-1:2026, 6.5).
In addition, the distance between lower and upper specification limit shall also satisfy the following condition: upper specification limit minus lower specification limit shall not be less than the quantity 2R evaluated at lower method scope limit plus 2R evaluated at upper method scope limit. See Figure 1 for an illustration of this concept.
ISO 4259-2:2026(en) Usually, specifications deal with limits for the values of the properties. To avoid uncertainty, such limits are normally expressed as “not less than” or “not greater than”. Limits are of two types:
- a double limit, upper and lower, for example viscosity not less than 5 mm /s and not greater than
...
Contents
- Introduction
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 programme d'essais d'aptitude
- 3.2 destinataire
- 3.3 fournisseur
- 4 Application et signification de la répétabilité, r, et de la reproductibilité, R
- 4.1 Généralités
- 4.2 Répétabilité, r
- 4.3 Reproductibilité, R
- 4.4 Utilisation de la reproductibilité pour déterminer le biais entre deux méthodes d’essai
- 5 Spécifications
- 5.1 But des spécifications
- 5.2 Établissement des limites de spécifications en liaison avec le domaine d’application et
- 6 Évaluation de la conformité de la qualité aux spécifications
- 6.1 Généralités
- 6.2 Évaluation de la conformité de la qualité par le fournisseur
- 6.3 Évaluation de la conformité de la qualité par le destinataire
- 7 Procédure en cas de litige
- 7.1 Résolution des litiges par la négociation
- 7.2 Utilisation de la méthode d'essai ou de la procédure en cas de litige
- 7.3 Procédure de résolution des litiges
- 7.4 Litige non résolu
- 7.5 Exemple de résolution d’un litige
- Annexe A
- 1 N 1 N
- Annexe B
- Bibliographie
Introduction
Pour les besoins de l’établissement de spécifications de produits et pour vérifier la conformité de ces produits à ces spécifications, les méthodes d’essai normalisées sont généralement référencées pour les caractéristiques des produits pétroliers commerciaux et des produits connexes. Deux ou plusieurs déterminations de la même caractéristique d'un échantillon donné, selon une méthode d'essai spécifique ou selon des méthodes d’essai différentes qui visent à mesurer la même caractéristique, ne donneront généralement pas exactement le même résultat. Il est donc nécessaire de correctement tenir compte de ce fait lors de l’établissement des spécifications du produit, en évaluant si les différences entre les résultats d’essais sont conformes aux attentes statistiques et en prenant des décisions quant à la conformité à une spécification sur la base d’un nombre limité de résultats d’essais. En utilisant des estimations basées sur les statistiques de la fidélité d'une méthode, ce qui suit peut être déterminé:
- une mesure objective de la fiabilité des limites de spécification,
- une décision de conformité à une spécification,
- le degré de concordance attendu entre deux ou plusieurs résultats obtenus dans des conditions données. Le présent document décrit les applications de la fidélité de méthodes d'essai déterminée à partir de l’ISO 4259-1. Elle est destinée à être utilisée conjointement avec les autres parties de la série ISO 4259 afin de fournir des indications supplémentaires sur l'application des estimations de fidélité. L'ISO 4259-3 spécifie comment utiliser la fidélité pour évaluer la capacité via des essais d'aptitude et l'ISO 4259-4 spécifie comment utiliser cette fidélité pour évaluer le statut «sous maîtrise statistique» et la fiabilité d'un laboratoire spécifique dans l'exécution d'une méthode d'essai. En outre, l'ISO 4259-5 spécifie l'approche générale pour juger de l'accord entre deux méthodes de mesure différentes qui prétendent mesurer la même propriété. L’ISO 4259-1 et le présent document regroupent tous les deux la détermination d’estimations de fidélité et l’application des données de fidélité. Les principes énoncés dans ces documents s'efforcent de s'aligner [1] [2] sur l’ASTM D6300 concernant la détermination des estimations de fidélité et sur l’ASTM D3244 pour l’utilisation des données d’essai.
Un glossaire des variables utilisées dans le présent document est donné en Annexe I de l’ISO 4259-1:2026.
Norme internationale ISO 4259-2:2026(fr) Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 2:
Interprétation et application des valeurs de fidélité relatives aux méthodes d'essai
1 Domaine d'application
Le présent document spécifie la méthodologie pour l’application des estimations de fidélité d’une méthode d’essai déterminée selon les processus spécifiés dans l’ISO 4259-1. En particulier, il spécifie les procédures à suivre pour fixer les limites de spécification d’une caractéristique sur la base de la fidélité de la méthode d'essai lorsque la caractéristique est déterminée en utilisant une méthode d'essai spécifique, et il détermine la conformité à une spécification quand il y a des résultats contradictoires entre le fournisseur et le destinataire. D'autres applications de cette fidélité des méthodes d'essai sont brièvement décrites en principe sans les procédures associées.
Les procédures du présent document ont été conçues spécifiquement pour les produits pétroliers et leurs produits connexes qui sont normalement homogènes. Cependant, les procédures décrites dans le présent document peuvent aussi s’appliquer à d’autres types de produits homogènes. Le présent document n’est pas applicable aux produits non-homogènes.
2 Références normatives
Le document suivant est mentionné afin que la totalité ou une partie de son contenu constitue des exigences de ce document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements). ISO 4259-1:2026, Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 1: Détermination des valeurs de fidélité relatives aux méthodes d’essai ISO 4259-3, Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 3:
Surveillance et vérification des données de fidélité publiées relatives aux méthodes d'essai ISO 4259-4, Produits pétroliers et connexes — Fidélité des méthodes de mesure et de leurs résultats — Partie 4:
Utilisation de cartes de contrôle statistique pour valider l’état 'sous maîtrise statistique' pour l’exécution d'une méthode d'essai normalisée dans un seul laboratoire
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions de l’ISO 4259-1 ainsi que les suivants s'appliquent.
L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
- IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
ISO 4259-2:2026(fr)
3.1 programme d'essais d'aptitude
PTS programme conçu pour l'évaluation périodique de l’aptitude des laboratoires participants à pratiquer la méthode d’essai normalisée par l'analyse statistique de leurs résultats obtenus sur des aliquotes préparés à partir d’un lot unique de produit homogène Note 1 à l'article: La fréquence de ces essais varie en fonction de l'objectif du programme. Chaque exécution d’essais consiste à tester un lot unique de produit. Les produits varient généralement d’un essai à l’autre. Note 2 à l'article: Ceci est également communément appelé programme de contrôle croisé interlaboratoires (ILCP).
3.2 destinataire
personne physique ou morale qui reçoit ou accepte le produit livré par le fournisseur (3.3)
3.3 fournisseur
personne physique ou morale responsable de la qualité d'un produit juste avant qu'il ne soit pris en charge par le destinataire (3.2)
4 Application et signification de la répétabilité, r, et de la reproductibilité, R
4.1 Généralités
Les valeurs de répétabilité et de reproductibilité sont estimées à partir de l'analyse de variance (plan factoriel à deux facteurs avec répétition) effectuée sur les résultats d'un programme interlaboratoires organisé à des fins statistiques et dans lequel différents laboratoires procèdent chacun à l'essai sur une gamme d'échantillons. Les valeurs de répétabilité et de reproductibilité déterminées selon l’ISO 4259-1 doivent être incluses dans chaque méthode d'essai publiée.
NOTE 1 Voir l'Annexe A pour un aperçu du raisonnement statistique sous-jacent aux formules de l’Article 4. NOTE 2 D’autres techniques statistiques équivalentes peuvent aussi être utilisées pour ces estimations. Dans les paragraphes 4.2 à 4.4, il est supposé que le(s) résultat(s) sont obtenus à partir d'une méthode d'essai qui est «sous maîtrise statistique» et «sans aucune preuve statistique d'un biais systémique» par rapport à l'industrie. Pour la détermination du statut «sous maîtrise statistique», voir l'ISO 4259-4 et pour la détermination du statut «sans aucune preuve statistique d'un biais systémique» par rapport à l'industrie, voir l'ISO 4259-3.
4.2 Répétabilité, r
4.2.1 Généralités
Pour les besoins des contrôles qualité de routine, la plupart des laboratoires n'effectuent qu'un seul essai par échantillon, sauf dans certains cas, par exemple en cas de litige ou lorsque l'opérateur désire vérifier que la technique utilisée est correcte. Dans ces cas, lorsque plusieurs résultats sont obtenus, il est utile de contrôler la cohérence des résultats répétés vis-à-vis de la répétabilité de la méthode. La procédure appropriée est exposée en 4.2.2. Il est également utile de connaître le degré de confiance qui peut être accordé aux résultats moyens, voir 4.2.3 pour la méthode permettant de le déterminer.
4.2.2 Acceptabilité des résultats
Lorsque deux résultats seulement sont obtenus dans les conditions de répétabilité et que leur différence est inférieure ou égale à r, l'opérateur d’essai peut considérer que son travail est sous contrôle et prendre la moyenne des deux résultats comme la valeur estimée de la caractéristique mesurée.
ISO 4259-2:2026(fr) Si les deux résultats diffèrent de plus de r, ils doivent être considérés comme suspects et il est nécessaire d'obtenir au moins trois résultats supplémentaires. La différence entre le résultat le plus divergent et la moyenne des autres doit être ensuite calculée et comparée à une nouvelle valeur, r , au lieu de r, selon la
Formule (1):
k rr�� � (1)
21k
où k est le nombre total de résultats obtenus.
Si la différence est inférieure ou égale à r , tous les résultats doivent être acceptés. Si la différence est
supérieure à r , le résultat le plus divergent doit être rejeté et la procédure spécifiée dans le présent
paragraphe répétée jusqu'à ce qu'un ensemble de résultats acceptables soit obtenu. La moyenne des résultats acceptables doit être prise comme la valeur estimée de la caractéristique. Cependant, si deux résultats ou plus, sur un total ne dépassant pas 20, ont été rejetés, le mode opératoire et l'appareillage doivent être vérifiés et une nouvelle série d'essais effectuée. 4.2.3 Calculs des intervalles de confiance utilisant les résultats obtenus dans les conditions de répétabilité Lorsqu'un opérateur d’essai unique, travaillant dans les limites de fidélité de la méthode, obtient dans les conditions de répétabilité, une série de k résultats fournissant une moyenne, X , et lorsque les résultats sont conformes à l’exigence de répétabilité en 4.2.2, il peut être admis avec un niveau de confiance de 95 %, que la valeur vraie, μ, de la caractéristique se situe dans les limites suivantes, données dans la Formule (2):
R R
X X (2)
Où R est définie dans la Formule (3):
1
RRr 1 (3)
k
Lorsque k = 1, utiliser le résultat d’essai unique comme la valeur pour le terme X dans la Formule (4):
R R
X X (4)
où R est la reproductibilité de la méthode d’essai publiée comme indiqué en 4.3. De même, dans le cas d'une seule limite, lorsqu'une seule limite (supérieure ou inférieure) est fixée, il peut être admis, avec un niveau de confiance de 95 %, que la valeur vraie, μ, de la caractéristique est limitée par une limite supérieure telle que définie par la Formule (5):
XR05, 9 (5)
Ou par une limite inférieure telle que définie par la Formule (6) XR05, 9 (6)
0,84 Le facteur 0,59 est le rapport , où 0,84 est issu de l'Annexe A.
Lorsque r est beaucoup plus petit que R, une répétition des essais, dans les conditions de répétabilité, n'apporte qu'une faible amélioration à l'intervalle de confiance de la moyenne.
ISO 4259-2:2026(fr)
4.3 Reproductibilité, R
4.3.1 Acceptabilité des résultats
La procédure décrite dans le présent paragraphe est destinée à apprécier, en fonction de la reproductibilité de la méthode d'essai, la compatibilité des résultats obtenus par plusieurs laboratoires dans des opérations de routine et lors des transactions. En cas de litige entre un fournisseur et un destinataire, on doit procéder comme indiqué dans les Articles 5 à 7.
Lorsque la différence entre deux résultats individuels obtenus dans deux laboratoires est inférieure ou égale à R, les deux résultats doivent être considérés comme acceptables et utilisés pour calculer la moyenne X . Cette moyenne X , et non pas l'un ou l'autre des résultats individuels séparément, doit être utilisée comme la valeur estimée de la caractéristique mesurée.
La valeur vraie, µ, de la caractéristique est comprise dans l’intervalle défini par les limites suivantes avec un niveau de confiance de 95 %:
R R X X (7)
De même, dans le cas d'une seule limite, lorsqu'une seule limite (supérieure ou inférieure) est fixée, la valeur vraie, µ, de la caractéristique est comprise dans l’intervalle défini par les limites suivantes avec un niveau de confiance de 95 %. Pour une limite supérieure, voir la Formule (8):
XR04, 2 (8)
ou pour une limite inférieure, voir la Formule (9):
XR04, 2 (9)
05, 9 Le facteur 0,42 est le rapport , étant donné qu’il s'agit d’une moyenne de deux résultats.
Si la différence entre les deux résultats est supérieure à R, ils doivent, l'un et l'autre, être considérés comme suspects. Chaque laboratoire doit alors obtenir au moins trois autres résultats acceptables (voir 4.2.2). Dans ce cas, la différence entre les moyennes de tous les résultats acceptables de chaque laboratoire doit être appréciée en utilisant, au lieu de R, une nouvelle valeur, R , telle que donnée par la Formule (10):
1 1
RRr 1 (10)
2kk2
où R est la reproductibilité de la méthode; r est la répétabilité de la méthode; k est le nombre de résultats du premier laboratoire;
k est le nombre de résultats du second laboratoire.
Si la différence entre les moyennes est inférieure ou égale à R , ces moyennes sont alors acceptables et leur
moyenne doit être considérée comme la valeur estimée de la caractéristique mesurée. Si la différence entre les moyennes est supérieure à R et s’il y a un litige sur la conformité à une spécification de la caractéristique
testée, alors la procédure spécifiée à l’Article 7 doit être adoptée. S’il y a plus que 2 laboratoires, chacun fournissant un ou plusieurs résultats acceptables, la différence entre la moyenne de laboratoire la plus divergente et la moyenne des moyennes des N laboratoires restants doit être comparée à R :
ISO 4259-2:2026(fr) où 2 2 RR 1 4 R (11)
22N
r 11 1
RR N (12)
N kk k
12 N R est donné dans la Formule (3) et correspond à la moyenne de laboratoire la plus divergente.
Si cette différence est égale ou inférieure à R , en valeur absolue, tous les résultats doivent être considérés
comme acceptables et leur moyenne prise comme valeur estimée de la caractéristique. Si cette différence est plus grande que R , la moyenne de laboratoire la plus divergente doit être éliminée
et la comparaison basée sur les Formules (11) et (12) répétée jusqu'à ce qu'un ensemble de moyennes de laboratoire acceptables soit obtenu.
La moyenne de ces moyennes de laboratoire doit être prise comme la valeur estimée de la caractéristique. Toutefois, si deux ou plusieurs moyennes de laboratoire, sur un total ne dépassant pas 20, ont été rejetées, le mode opératoire et l'appareillage doivent être vérifiés et une nouvelle série d'essais effectuée. 4.3.2 Calculs des intervalles de confiance utilisant les résultats obtenus dans les conditions de reproductibilité Lorsque N laboratoires obtiennent, dans les conditions de répétabilité et de reproductibilité, un ou plusieurs résultats donnant une moyenne de moyennes de laboratoire X , la valeur vraie, μ, de la caractéristique est comprise dans les limites suivantes avec un niveau de confiance de 95 %:
R R
XX (13) 22N N De même, dans le cas d'une seule limite, lorsqu'une seule limite (supérieure ou inférieure) est fixée, la valeur vraie, μ, de la caractéristique est comprise dans les limites suivantes avec un niveau de confiance de 95 % par une limite supérieure telle que définie par la Formule (14):
R
X 05, 9 (14)
N Ou par une limite inférieure telle que définie par la Formule (15) R
X 05, 9 (15)
N
4.4 Utilisation de la reproductibilité pour déterminer le biais entre deux méthodes d’essai
différentes qui prétendent mesurer la même propriété
4.4.1 Généralités
Pour le cas où deux méthodes d'essai différentes prétendent mesurer la même propriété, les estimations de la reproductibilité (R) obtenues à partir des méthodes d'essai respectives doivent être utilisées conjointement avec les moyennes obtenues à partir de plusieurs laboratoires pour le même produit afin de déterminer si une correction de biais peut être appliquée pour améliorer statistiquement la concordance entre les deux méthodes pour ce produit. Par exemple, les résultats recueillis par le biais de programmes d'essais d'aptitude
ISO 4259-2:2026(fr) (PTS) pour les différentes méthodes d'essai en utilisant le même échantillon peuvent être analysés de cette façon.
NOTE Une discussion sur la méthodologie pour ce type d'évaluation pour l'analyse simultanée de plusieurs produits/niveaux d’une propriété qui couvrent le champ d'intersection de deux méthodes d'essai différentes n’est pas [3] compris dans le domaine d’application de ce document. Les lecteurs intéressés sont invités à consulter l’ISO 4259-5 pour plus d’information sur le sujet.
4.4.2 Processus
Supposons que la méthode d'essai A et la méthode d'essai B sont des méthodes d'essai qui prétendent mesurer la propriété C.
Calculer la statistique suivante:
YY AB Z (16)
R R A B
7,,683L 7 683L A B où Y est la moyenne des résultats L pour la propriété C pour un produit suivant la méthode d’essai A, A A où chaque résultat est un résultat unique obtenu dans les conditions de reproductibilité; L est le nombre total de laboratoires (résultats) pour la méthode d'essai A et dont il convient qu’il A soit > 20; R est la reproductibilité de la méthode d'essai A; A Y est la moyenne des résultats L pour la propriété C d’un produit suivant la méthode d'essai B B B sur le même produit soumis à essai suivant la méthode d'essai A, où chaque résultat est un résultat unique obtenu dans les conditions de reproductibilité; L est le nombre total de laboratoires (résultats) pour la méthode d'essai B et dont il convient qu’il B soit > 20; R est la reproductibilité de la méthode d'essai B.
B Si Z > 2, il doit être conclu, avec un niveau de confiance de 95 %, qu’une correction de biais constante améliore statistiquement le degré de concordance entre la méthode d'essai A et la méthode d'essai B pour la propriété C de ce produit.
5 Spécifications
5.1 But des spécifications
Une spécification a pour but de spécifier une ou des limites acceptables à la valeur vraie, µ, pour la caractéristique telle que déterminée selon une méthode d’essai spécifique. En pratique, cependant, cette valeur vraie ne peut jamais être obtenue exactement étant donné que les résultats obtenus par un seul ou par plusieurs laboratoires appliquant la méthode d'essai spécifiée peuvent avoir une dispersion acceptable telle que spécifiée par la répétabilité et la reproductibilité. Par conséquent, il existe toujours une certaine incertitude quant à la valeur vraie de chaque caractéristique mesurée déterminée à partir d’un nombre fini de résultats d’essai.
La conformité des produits pétroliers avec les spécifications est évaluée suivant les Articles 6 et 7. Sur la base d'un accord préalable, un fournisseur et un destinataire peuvent utiliser les procédures alternatives décrites dans l'Annexe B.
AVERTISSEMENT — Il est important que la méthode d’essai spécifiée pour la détermination de la caractéristique soumise à la/aux limite(s) d’une spécification soit suffisamment précise pour déterminer de manière fiable si le produit satisfait ou non aux spécifications.
ISO 4259-2:2026(fr)
5.2 Établissement des limites de spécifications en liaison avec le domaine d’application et
la fidélité de la méthode d’essai spécifiée Les limites de spécification ne doivent pas être hors des limites du domaine d’application de la méthode telles que déterminées dans l'ISO 4259-1.
La limite de spécification inférieure ne doit pas être en dessous de la limite inférieure du domaine d’application de la méthode d'essai et la limite de spécification supérieure ne doit pas être au-dessus de la limite supérieure du domaine d’application de la méthode d'essai (tel que spécifié dans l’ISO 4259-1:2026, 6.5).
...