Measurement of radioactivity in the environment — Air: radon-222 — Part 5: Continuous measurement method of the activity concentration

ISO 11665-5:2012 describes continuous measurement methods for radon-222. It gives indications for continuous measuring of the temporal variations of radon activity concentration in open or confined atmospheres. ISO 11665-5:2012 is intended for assessing temporal changes in radon activity concentration in the environment, in public buildings, in homes and in work places, as a function of influence quantities such as ventilation and/or meteorological conditions.

Mesurage de la radioactivité dans l'environnement — Air: radon 222 — Partie 5: Méthode de mesure en continu de l'activité volumique

L'ISO 11665-5:2012 décrit uniquement les méthodes de mesure en continu du radon 222. Elle donne des indications pour le mesurage en continu des variations temporelles de l'activité volumique du radon dans des atmosphères libres ou confinées. L'ISO 11665-5:2012 est destinée à évaluer les variations temporelles de l'activité volumique du radon dans l'environnement, les bâtiments publics, les habitations et les lieux de travail en fonction de grandeurs d'influence telles que les conditions de ventilation et/ou météorologiques.

General Information

Status
Withdrawn
Publication Date
12-Jul-2012
Withdrawal Date
12-Jul-2012
Current Stage
9599 - Withdrawal of International Standard
Start Date
13-Jan-2020
Completion Date
08-Nov-2025
Ref Project
Standard
ISO 11665-5:2012 - Measurement of radioactivity in the environment -- Air: radon-222
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11665-5:2012 - Mesurage de la radioactivité dans l'environnement -- Air: radon 222
French language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 11665-5
First edition
2012-07-15
Measurement of radioactivity in the
environment — Air: radon-222 —
Part 5:
Continuous measurement method of the
activity concentration
Mesurage de la radioactivité dans l’environnement — Air: radon 222 —
Partie 5: Méthode de mesure en continu de l’activité volumique
Reference number
©
ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved

Contents Page
Foreword .iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 1
4 Principle . 2
5 Equipment . 3
6 Sampling . 3
6.1 Sampling objective . 3
6.2 Sampling characteristics . 3
6.3 Sampling conditions . 3
7 Detection . 4
8 Measurement . 4
8.1 Procedure . 4
8.2 Influence quantities . 4
8.3 Calibration . 4
9 Expression of results . 5
9.1 Radon activity concentration . 5
9.2 Standard uncertainty . 5
9.3 Decision threshold and detection limit . 5
9.4 Limits of the confidence interval . 5
10 Test report . 5
Annex A (informative) Measurement method using a vented ionization chamber and a current
ionization chamber . 7
Bibliography .13
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11665-5 was prepared by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies, and
radiological protection, Subcommittee SC 2, Radiological protection.
ISO 11665 consists of the following parts, under the general title Measurement of radioactivity in the
environment — Air: radon-222:
— Part 1: Origins of radon and its short-lived decay products and associated measurement methods
— Part 2: Integrated measurement method for determining average potential alpha energy concentration of
its short-lived decay products
— Part 3: Spot measurement method of the potential alpha energy concentration of its short-lived decay products
— Part 4: Integrated measurement method for determining average activity concentration using passive
sampling and delayed analysis
— Part 5: Continuous measurement method of the activity concentration
— Part 6: Spot measurement method of the activity concentration
— Part 7: Accumulation method for estimating surface exhalation rate
— Part 8: Methodologies for initial and additional investigations in buildings
The following parts are under preparation:
— Part 9: Method for determining exhalation rate of dense building materials
— Part 10: Determination of diffusion coefficient in waterproof materials using activity concentration measurement
iv © ISO 2012 – All rights reserved

Introduction
Radon isotopes 222, 220 and 219 are radioactive gases produced by the disintegration of radium isotopes 226,
224 and 223, which are decay products of uranium-238, thorium-232 and uranium-235 respectively, and are
all found in the earth’s crust. Solid elements, also radioactive, followed by stable lead are produced by radon
[1]
disintegration .
When disintegrating, radon emits alpha particles and generates solid decay products, which are also radioactive
(polonium, bismuth, lead, etc.). The potential effects on human health of radon lie in its solid decay products
rather than the gas itself. Whether or not they are attached to atmospheric aerosols, radon decay products can
be inhaled and deposited in the bronchopulmonary tree to varying depths according to their size.
Radon is today considered to be the main source of human exposure to natural radiation. The UNSCEAR (2006)
[2]
report suggests that, at the worldwide level, radon accounts for around 52 % of global average exposure to
natural radiation. The radiological impact of isotope 222 (48 %) is far more significant than isotope 220 (4 %),
while isotope 219 is considered negligible. For this reason, references to radon in this part of of ISO 11665 refer
only to radon-222.
Radon activity concentration can vary by one to multiple orders of magnitude over time and space. Exposure
to radon and its decay products varies tremendously from one area to another, as it depends firstly on the
amount of radon emitted by the soil and the building materials in each area and, secondly, on the degree of
containment and weather conditions in the area where individuals are exposed.
The values commonly found in the continental environment are usually between a few becquerels per cubic
metre and several thousand becquerels per cubic metre. Activity concentrations of one becquerel per cubic
metre or less can be observed in the oceanic environment. Radon activity concentrations inside houses can
[3]
vary from several tens of becquerels per cubic metre to several hundreds of becquerels per cubic metre .
Activity concentrations can reach several thousands of becquerels per cubic metre in very confined spaces.
The activity concentration of radon-222 in the atmosphere can be measured by spot, continuous and integrated
measurement methods with active or passive air sampling (see ISO 11665-1). This part of ISO 11665 deals with
continuous measurement methods for radon-222.
NOTE The origin of radon-222 and its short-lived decay products in the atmospheric environment and other
measurement methods are described generally in ISO 11665-1.
INTERNATIONAL STANDARD ISO 11665-5:2012(E)
Measurement of radioactivity in the environment — Air:
radon-222 —
Part 5:
Continuous measurement method of the activity concentration
1 Scope
This part of ISO 11665 describes continuous measurement methods for radon-222. It gives indications for
continuous measuring of the temporal variations of radon activity concentration in open or confined atmospheres.
This part of ISO 11665 is intended for assessing temporal changes in radon activity concentration in the
environment, in public buildings, in homes and in work places, as a function of influence quantities such as
ventilation and/or meteorological conditions.
The measurement method described is applicable to air samples with radon activity concentration greater
than 5 Bq/m .
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 11665-1, Measurement of radioactivity in the environment — Air: radon-222 — Part 1: Origins of radon and
its short-lived decay products and associated measurement methods
ISO 11929, Determination of the characteristic limits (decision threshold, detection limit and limits of the
confidence interval) for measurements of ionizing radiation — Fundamentals and application
ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
IEC 61577-1, Radiation protection instrumentation — Radon and radon decay product measuring instruments —
Part 1: General principles
IEC 61577-2, Radiation protection instrumentation — Radon and radon decay product measuring instruments —
Part 2: Specific requirements for radon measuring instruments
3 Terms, definitions and symbols
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11665-1 apply.
3.2 Symbols
For the purposes of this document, the symbols given in ISO 11665-1 and the following apply.
C activity concentration, in becquerels per cubic metre

C decision threshold of the activity concentration, in becquerels per cubic metre
#
C detection limit of the activity concentration, in becquerels per cubic metre

lower limit of the confidence interval of the activity concentration, in becquerels per cubic metre
C

upper limit of the confidence interval of the activity concentration, in becquerels per cubic metre
C
U
expanded uncertainty calculated by Uk=⋅u with k = 2
()
u()
standard uncertainty associated with the measurement result
u
()
relative standard uncertainty
rel
µ quantity to be measured
µ background level
ω correction factor linked to the calibration factor and climatic correction factors
4 Principle
Continuous measurement of the radon activity concentration is based on the following elements:
a) continuous in situ sampling of a volume of air previously filtered and representative of the atmosphere
under investigation;
b) continuous detection of radiations emitted by radon and its decay products accumulated in the
detection chamber.
Several measurement methods meet the requirements of this part of ISO 11665. They are basically distinguished
by the type of physical quantity and how it is detected. The physical quantity and its related detection may be
as follows, for example:
— ionization current produced by several tens of thousands of ion pairs created by each alpha particle
emitted by the radon that is present in the detection chamber and its decay products formed therein
(see Annex A);
— charges produced in a solid [semi-conductor medium (silicon)] by ionization from alpha particles of rad
...


NORME ISO
INTERNATIONALE 11665-5
Première édition
2012-07-15
Mesurage de la radioactivité dans
l’environnement — Air: radon 222 —
Partie 5:
Méthode de mesure en continu de
l’activité volumique
Measurement of radioactivity in the environment — Air: radon-222 —
Part 5: Continuous measurement method of the activity concentration
Numéro de référence
©
ISO 2012
DOCUMENT PROTÉGÉ PAR COPYRIGHT
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord écrit
de l’ISO à l’adresse ci-après ou du comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2012 – Tous droits réservés

Sommaire Page
Avant-propos .iv
Introduction . v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes, définitions et symboles . 1
3.1 Termes et définitions . 1
3.2 Symboles . 1
4 Principe . 2
5 Équipement . 3
6 Prélèvement . 3
6.1 Objectif du prélèvement . 3
6.2 Caractéristiques du prélèvement . 3
6.3 Conditions de prélèvement . 3
7 Détection . 4
8 Mesurage . 4
8.1 Mode opératoire . 4
8.2 Grandeurs d’influence . 4
8.3 Étalonnage . 4
9 Expression des résultats . 5
9.1 Activité volumique du radon . 5
9.2 Incertitude type . 5
9.3 Seuil de décision et limite de détection . 5
9.4 Limites de l’intervalle de confiance . 5
10 Rapport d’essai . 5
Annexe A (informative) Méthode de mesure utilisant une chambre d’ionisation à courant et
à circulation . 7
Bibliographie .13
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de
normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales,
en liaison avec l’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l’approbation de 75 % au moins des comités membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de droits
de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de ne pas avoir
identifié de tels droits de propriété et averti de leur existence.
L’ISO 11665-5 a été élaborée par le comité technique ISO/TC 85, Énergie nucléaire, technologies nucléaires
et radioprotection, sous-comité SC 2, Radioprotection.
L’ISO 11665 comprend les parties suivantes, présentées sous le titre général Mesurage de la radioactivité dans
l’environnement — Air: radon 222:
— Partie 1: Origine du radon et de ses descendants à vie courte et méthodes de mesure associées
— Partie 2: Méthode de mesure intégrée pour la détermination de l’énergie alpha potentielle volumique
moyenne de ses descendants à vie courte
— Partie 3: Méthode de mesure ponctuelle de l’énergie alpha potentielle volumique de ses descendants à vie
courte
— Partie 4: Méthode de mesure intégrée pour la détermination de l’activité volumique moyenne du radon
avec un prélèvement passif et une analyse en différé
— Partie 5: Méthode de mesure en continu de l’activité volumique
— Partie 6: Méthode de mesure ponctuelle de l’activité volumique
— Partie 7: Méthode d’estimation du flux surfacique d’exhalation par la méthode d’accumulation
— Partie 8: Méthodologies appliquées aux investigations initiales et complémentaires dans les bâtiments
Les parties suivantes sont en cours d’élaboration:
— Partie 9: Méthode de détermination du flux d’exhalation des matériaux de construction
— Partie 10: Détermination du coefficient de diffusion du radon des matériaux imperméables par mesure de
l’activité volumique du radon
iv © ISO 2012 – Tous droits réservés

Introduction
Les isotopes 222, 220 et 219 du radon sont des gaz radioactifs produits par la désintégration des isotopes 226,
224 et 223 du radium, lesquels sont respectivement des descendants de l’uranium 238, du thorium 232 et de
l’uranium 235 et sont tous présents dans l’écorce terrestre. Des éléments solides, eux aussi radioactifs, suivis
[1]
par du plomb stable sont produits par la désintégration du radon .
Lorsqu’il se désintègre, le radon émet des particules alpha et génères des descendants solides qui sont eux
aussi radioactifs (polonium, bismuth, plomb, etc.). Les effets potentiels du radon sur la santé humaine sont liés
aux descendants plutôt qu’au gaz lui-même. Qu’ils soient ou non attachés à des aérosols atmosphériques,
les descendants du radon peuvent être inhalés et déposés dans l’arbre broncho-pulmonaire à différentes
profondeurs, suivant leur taille.
Le radon est aujourd’hui considéré comme la principale source d’exposition de l’homme au rayonnement
[2]
naturel. Le rapport de l’UNSCEAR (2006) suggère qu’au niveau mondial, le radon intervient pour environ
52 % à l’exposition moyenne globale au rayonnement naturel. L’impact radiologique de l’isotope 222 (48 %)
est nettement plus important que celui de l’isotope 220 (4 %), l’isotope 219 est quant à lui considéré comme
négligeable. Pour cette raison, le terme radon dans la présente partie de l’ISO 11665 désignera exclusivement
le radon 222.
L’activité volumique du radon peut varier d’un à plusieurs ordres de grandeur dans le temps et l’espace.
L’exposition au radon et à ses descendants varie considérablement d’un lieu à l’autre, étant donné qu’elle
dépend tout d’abord de la quantité de radon émise par le sol et les matériaux de construction en ces lieux et,
ensuite, du degré de confinement et des conditions météorologiques des lieux où sont exposées les personnes.
Les valeurs communément rencontrées dans un environnement continental sont généralement comprises
entre quelques becquerels par mètre cube et plusieurs milliers de becquerels par mètre cube. Des activités
volumiques d’un becquerel par mètre cube ou moins peuvent être observées dans l’environnement océanique.
À l’intérieur des bâtiments, les activités volumiques du radon peuvent varier entre quelques dizaines de
[3]
becquerels par mètre cube et plusieurs centaines de becquerels par mètre cube . Les activités volumiques
peuvent atteindre plusieurs milliers de becquerels par mètre cube dans des espaces très confinés.
L’activité volumique du radon 222 dans l’atmosphère peut être mesurée par des méthodes de mesure
ponctuelle, en continu et intégrée avec prélèvement d’air actif ou passif (voir ISO 11665-1). la présente partie
de l’ISO 11665 traite des méthodes de mesure en continu du radon 222.
NOTE L’origine du radon 222 et de ses descendants à vie courte dans l’environnement atmosphérique ainsi que
d’autres méthodes de mesure sont décrites de manière générale dans l’ISO 11665-1.
NORME INTERNATIONALE ISO 11665-5:2012(F)
Mesurage de la radioactivité dans l’environnement — Air:
radon 222 —
Partie 5:
Méthode de mesure en continu de l’activité volumique
1 Domaine d’application
La présente partie de l’ISO 11665 décrit uniquement les méthodes de mesure en continu du radon 222. Elle
donne des indications pour le mesurage en continu des variations temporelles de l’activité volumique du radon
dans des atmosphères libres ou confinées.
La présente partie de l’ISO 11665 est destinée à évaluer les variations temporelles de l’activité volumique
du radon dans l’environnement, les bâtiments publics, les habitations et les lieux de travail en fonction de
grandeurs d’influence telles que les conditions de ventilation et/ou météorologiques.
La méthode de mesure décrite s’applique aux échantillons d’air dont l’activité volumique du radon est
supérieure à 5 Bq/m .
2 Références normatives
Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les
références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du
document de référence (y compris les éventuels amendements) s’applique.
ISO 11665-1, Mesurage de la radioactivité dans l’environnement — Air: radon 222 — Partie 1: Origine du radon
et de ses descendants à vie courte et méthodes de mesure associées
ISO 11929, Détermination des limites caractéristiques (seuil de décision, limite de détection et extrémités de
l’intervalle de confiance) pour mesurages de rayonnements ionisants — Principes fondamentaux et applications
ISO/CEI 17025, Exigences générales concernant la compétence des laboratoires d’étalonnages et d’essais
CEI 61577-1, Instrumentation pour la radioprotection — Instruments de mesure du radon et des descendants
du radon — Partie 1: Règles générales
CEI 61577-2, Instrumentation pour la radioprotection — Instrument de mesure du radon et des descendants du
radon — Partie 2: Exigences spécifiques concernant les instruments de mesure du radon
3 Termes, définitions et symboles
3.1 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 11665-1 s’appliquent.
3.2 Symboles
Pour les besoins du présent document, les symboles décrits dans l’ISO 11665-1 ainsi que les suivants
s’appliquent.
C activité volumique, en becquerels par mètre cube

C seuil de décision de l’activité volumique, en becquerels par mètre cube
#
C limite de détection de l’activité volumique, en becquerels par mètre cube

limite basse de l’intervalle de confiance, pour l’activité volumique, en becquerels par mètre cube
C

limite haute de l’intervalle de confiance, pour l’activité volumique, en becquerels par mètre cube
C
U
incertitude étendue calculée par Uk=⋅u avec k = 2
()
u
()
incertitude type associée au résultat du mesurage
u
() incertitude standard relative
rel
m quantité à mesurer
m niveau de bruit de fond
w facteur de correction lié au facteur d’étalonnage et aux facteurs de correction climatique
4 Principe
Le mesurage en continu de l’activité volumique moyenne du radon est fondée sur
a) le prélèvement in situ et continu d’un volu
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.