Sodium hydroxide for industrial use — Determination of silica content — Gravimetric method by precipitation of quinoline molybdosilicate

Hydroxyde de sodium à usage industriel — Dosage de la silice — Méthode gravimétrique par précipitation du molybdosilicate de quinoléine

General Information

Status
Withdrawn
Publication Date
31-Jan-1976
Withdrawal Date
31-Jan-1976
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Aug-1990
Ref Project

Buy Standard

Standard
ISO 985:1976 - Sodium hydroxide for industrial use -- Determination of silica content -- Gravimetric method by precipitation of quinoline molybdosilicate
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 985:1976 - Sodium hydroxide for industrial use — Determination of silica content — Gravimetric method by precipitation of quinoline molybdosilicate Released:2/1/1976
French language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD 985
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION *MEXLlYHAPOlIHAR OPrAHM3AUMII il0 CTAHLiAPTM3AUWB .ORGANISATION INTERNATIONALE DE NORMALISATION
*L-,
Sodium hydroxide for industrial use - Determination of
silica content - Gravimetric method by precipitation of
quinoline molybdosilicate
Hydroxyde de sodium à usage industriel - Dosage de la silice - Méthode gravimétrique par précipitation
du molybdosilicate de quinoléine
First edition - 1976-02-01
~~
Ref. No. IS0 985-1976 (E)
UDC 661.322.1 : 546.284 : 543.21
Descriptors : sodium hydroxide, chemical analysis, determination of content, silicon dioxide, gravimetric analysis.
Price based on 3 pages

---------------------- Page: 1 ----------------------
FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
(IS0 Member Bodies). The work of developing
of national standards institutes
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
Prior to 1972, the results of the work of the Technical Committees were published
as IS0 Recommendations; these documents are now in the process of being
transformed into International Standards. As part of this process, Technical
Committee ISO/TC 47 has reviewed IS0 Recommendation R 985 and found it
technically suitable for transformation. International Standard IS0 985 therefore
replaces IS0 Recommendation R 985-1969 to which it is technically identical.
IS0 Recommendation R 985 was approved by the Member Bodies of the following
countries :
Austria I ran South Africa, Rep. of
Belgium Ireland Spain
Switzerland
Chile Israel
Thailand
Cuba Italy
Czechoslovakia Japan Turkey
Egypt, Arab Rep. of Netherlands United Kingdom
France New Zealand U.S.A.
Germany Poland U.S.S. R.
Hungary Portugal Yugoslavia
India Romania
No Member Body expressed disapproval of the Recommendation.
The Member Body of the following country disapproved the transformation of
ISO/R 985 into an International Standard :
United Kingdom
International Organisation for Standardization, 1976
O
Printed in Switzerland

---------------------- Page: 2 ----------------------
~
IS0 985-1976 (E)
INTERNATIONAL STANDARD
Sodium hydroxide for industrial use - Determination of
silica content - Gravimetric method by precipitation of
quinoline molybdosilicate
1 SCOPE AND FIELD OF APPLICATION 5.4 Quinoline, 20 g/I hydrochloric solution.
This International Standard specifies a gravimetric method Dissolve 20 g of quinoline, p approximately 1,093 to
for the determination of the silica content of sodium 1,096g/ml, in 25ml of the hydrochloricacid solution (5.1).
hydroxide for industrial use, by precipitation of quinoline
Stir and dilute to 1 O00 ml.
molybdosilicate.
L 5.5 Washing solution.
The method is applicable to products having a silica (Sioz)
content. calculated on NaOH, equal to Or greater than
Dilute 25 ml of the quinoline hydrochloric solution (5.4)
0,001 % (m/m).
to 1 O00 ml.
5.6 Methyl orange, 0,5 g/I solution.
2 REFERENCE
I SO 3 1 95, Sodium hydroxide for industrial use - Sampling -
6 APPARATUS
Test sample - Preparation of the main solution for carrying
out certain determinations.
Ordinary laboratory apparatus and
3 PRINCIPLE 6.1 Filter crucible, with sintered disk of porosity grade
P 16 (pore diameter between 1 O and 16 pm).
Dissolution of a test portion and acidification by
hydrochloric acid solution, formation of the molybdosilicate
6.2 Electric oven, capable of being controlled at 150 * 2 OC.
and precipitation of a high molecular weight compound by
qui no1 ine.
7 PROCEDURE
Filtration, washing, drying at 150 f 2 "C and weighing of
the compound.
7.1 Test portion
L
4 REACTION
In a weighing bottle of capacity approximately 100 ml,
fitted with a ground glass stopper, weigh, to the nearest
The basic reaction (precipitation by quinoline introduced in
0.1 g, a mass of the solid or liquid test sample corresponding
the form of hydrochloride) is as follows :
to 20 * 0.1 g of NaOH (see IS0 3195).
12MoO3.SiO2.2H2O + 4C9H7N.HCI -C
NOTE - If the Si02 content of the test portion is higher than
0,010 g, it will be advisable to repeat the determination using a
( Cg H, N), .I 2Mo0, .SiO2 .2H20 + 4HCI
smaller test portion.
5 REAGENTS 7.2 Blank test
During the analysi
...

NORME INTERNATIONALE @ 985
~
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION aMEXLIYHAPOnHAI OPrAHM3AUMI no CTAHDAPTM3AUMM .ORGANISATION INTERNATIONALE DE NORMALISATION
Hydroxyde de sodium à usage industriel - Dosage de la
silice - Méthode gravimétrique par précipitation du
molybdosilicate de quinoléine
Sodium hydroxide for industrial use - Determination of silica content - Gravimetric method by
precipitation of quinoline molybdosilicate
Premiere edition - 1976-02-01
LL
CDU 661.322.1 : 546.284 : 543.21 Réf. no : IS0 985-1976 (F)
-
Descripteurs : hydroxyde de sodium, analyse chimique, dosage, silice, méthode gravimétrique.
3 pages
Prix base sur
w -- %I

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L'ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (Comités Membres ISO). L'élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I'ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I'ISO.
Avant 1972, les résultats des travaux des Comités Techniques étaient publiés
comme Recommandations ISO; maintenant, ces documents sont en cours de
transformation en Normes Internationales. Compte tenu de cette procédure, le
Comité Technique ISO/TC 47 a examiné la Recommandation ISO/R 985 et est
d'avis qu'elle peut, du point de vue technique, être transformée en Norme
Internationale. La présente Norme Internationale remplace donc la
Recommandation ISO/R 985-1969 à laquelle elle est techniquement identique.
La Recommandation ISO/R 985 avait été approuvée par les Comités Membres des
pays suivants :
Afrique du Sud, Rép. d' Inde Roumanie
I ran Royaume-Uni
Allemagne
Irlande Suisse
Autriche
Israël Tchécoslovaquie
Belgique
Italie Th aï I a nde
Chili
Turquie
Cuba Japon
U.R.S.S.
Egypte, Rép. arabe d' Nouvelle-Zélande
U.S.A.
Espagne Pays-Bas
Yougoslavie
France Po I ogn e
Hongrie Portugal
Aucun Comité Membre n'avait désapprouvé la Recommandation.
Le Comité Membre du pays suivant a désapprouvé la transformation de la
Recommandation ISO/R 985 en Norme Internationale :
Royaume-Uni
O Organisation Internationale de Normalisation, 1976
Imprimé en Suisse

---------------------- Page: 2 ----------------------
IS0 985-1976 (FI
NORM E I NT ER NAT I ON A LE
Hydroxyde de sodium à usage industriel - Dosage de la
silice - Méthode gravimétrique par précipitation du
molybdosilicate de quinoléine
1 OBJET ET DOMAINE D'APPLICATION 5.3 Acide oxalique, solution à 1 O0 g/I.
La présente Norme Internationale spécifie une méthode
5.4 Quinoléine, solution chlorhydrique à 20 dl
gravimétrique de dosage de la silice dans l'hydroxyde de
sodium à usage industriel, par précipitation du molybdo- Dissoudre 20 g de quinoléine, p 1,093 à 1,096 g/ml environ,
silicate de quinoléine. dans 25 ml de la solution d'acide chlorhydrique (5.1).
L
Agiter et compléter le volume à 1 O00 ml.
La méthode est applicable aux produits dont la teneur en
silice (Sioz), rapportée à NaOH, est égale ou supérieure à
5.5 Solution de lavage.
0,001 % (mlm).
Diluer 25 ml de la solution chlorhydrique de quinoléine
(5.4) à 1 O00 ml.
2 RÉFÉRENCE
IS0 31 95, Hydroxyde de sodium a usage industriel - Préiè-
5.6 Méthylorange, solution à 0,5 g/l.
vement - Echantillon pour essai - Préparation de la
solution principale pour l'exécution de certains dosages.
6 APPAREILLAGE
Matériel courant de laboratoire, et
3 PRINCIPE
Dissolution et acidification d'une prise d'essai en milieu
6.1 Creuset filtrant, à plaque frittée de porosité P 16
chlorhydrique, formation du molybdosilicate et précipi-
(diamètre des pores entre 10 et 16 pm).
tation par la quinoléine d'un composé de masse moléculaire
élevée.
6.2 Étuve électrique, réglable à 150 f 2 OC.
Filtration, lavage, séchage à 150 f 2 "C et pesée de ce
composé. 7 MODE OPÉRATOIRE
)U
7.1 Prise d'essai
4 RÉACTION
Peser, 2 0,1 9 Près. dans un VaSe à Peser 2 bouchon rodé.
L~ réaction de base, précipitation par la quinoléine intra-
de 100 ml environ, une masse de l'échantillon pour essai,
duite à l'état de chlorhydrate, est la suivante :
solide ou liquide, correspondant à 20 f 0.1 g de NaOH (voir
12MoO,.SiO2.2HZO + 4CgH7N.HCI - IS0 3195).
(C, H7N)4.12M003.SiOz .2Hz0 + 4HCI NOTE - Si la prise d'essai contient plus de 0,010 g de Sioz, il
convient de recommencer le dosage en diminuant la prise d'essai.
5 RÉACTIFS
7.2 Essai à blanc
Au cours de l'analyse, n'utiliser que des réactifs de qualité
Effectuer, parallèlement au dosage et en
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.