General Information

Abstract

This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 and EN 50173 4:2018. This also includes the transmission of BCT signals provided by a CATV, MATV or SMATV cable network.
The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

Status
Not Published
Public Enquiry End Date
31-Jan-2021
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
22-Sep-2026
Due Date
27-Nov-2026

Buy Documents

Draft

oSIST prEN 50117-9-1:2021

English language (16 pages)
Preview
Preview
e-Library read for
1 day

Overview

SIST EN 50117-9-1:2026 is a European standard that specifies requirements for coaxial indoor drop cables designed for analogue and digital signal transmission within the frequency range of 5 MHz to 1 000 MHz. Developed by the Slovenian Institute for Standardization (SIST), this standard is part of the EN 50117 series and targets cables used in cable television, sound distribution, and interactive service networks. These cables are essential for reliable signal transmission in CATV, MATV, SMATV, and Broadband Communication Technology (BCT) systems, supporting both one-way and two-way communications.

The standard outlines the applicable test methods and essential requirements concerning the electrical, mechanical, environmental, and fire performance characteristics of indoor drop coaxial cables. It supports compliance with European directives, such as the Low Voltage Directive (2014/35/EU), by ensuring cable safety and performance in relevant applications.

Key Topics

  • Scope of Application

    • Covers coaxial indoor drop cables operating at 5 MHz to 1 000 MHz
    • Used for both analogue and digital transmission in home and commercial environments
    • Supports CATV, MATV, SMATV, and BCT signals
  • Cable Construction and Design

    • Specifies requirements for inner and outer conductors, dielectric materials (such as polyolefins), and PVC or halogen-free flame retardant sheaths
    • Insists on reliable sheath marking and labeling for traceability, including attenuation values, screening class, Euro-class, and supplier name
  • Performance and Safety

    • Defines electrical performance parameters (attenuation, characteristic impedance, return loss, screening)
    • Specifies mechanical robustness (crush, bend, flexure tests)
    • Addresses environmental endurance (temperature cycles, cold performance)
    • Requires fire performance testing according to relevant EN standards
  • Testing and Quality Assurance

    • Mandates compliance with test methods from the EN 50117 and EN 50289 series
    • Describes procedures for electrical, mechanical, and environmental tests to ensure ongoing cable integrity
  • Regulatory Compliance

    • Ensures alignment with the Low Voltage Directive (2014/35/EU)
    • Describes material requirements under REACH and RoHS directives
    • Relates essential cable characteristics to Construction Products Regulation (CPR) for fixed installations

Applications

The cables specified by SIST EN 50117-9-1:2026 are widely used in:

  • Television Signal Distribution
    • Connecting subscriber equipment within residential or commercial buildings to cable television provider networks
  • Sound and Data Networks
    • Suitable for sound signal and broadband data transmission, supporting various interactive and digital services
  • Interactive Home Services
    • Enable reliable and high-quality signal paths for smart devices and home automation where two-way communication is required
  • Integrated Cable Systems
    • Used as indoor drop cables in complex RF and broadband communication systems, including full service television and multimedia setups

Typical users include cable network providers, property managers, system integrators, installers, and manufacturers of communication infrastructure.

Related Standards

For ensuring full systems compatibility and optimal performance, the following standards are closely related to SIST EN 50117-9-1:2026:

  • EN 50117-1:2019: Generic specification for coaxial cables
  • EN 60728-1:2014: System performance of forward paths for TV and interactive services
  • EN 60728-1-1:2014: RF cabling for two-way home networks
  • EN 60728-101:2017: System performance of forward paths with digital channels
  • EN 60728-10:2014: Return path system performance
  • EN 50173 series: Generic cabling systems for homes and commercial premises
  • EN 50289 & EN 50290 series: Test methods and common design rules for communication cables

Using SIST EN 50117-9-1:2026 in cable selection and installation helps ensure compliant, safe, and reliable signal distribution in a range of modern media and data networks.

Keywords: Coaxial cables, indoor drop cables, analogue and digital signal transmission, cable television, signal distribution, EN 50117-9-1, cable fire performance, cable testing, European cable standards.

Relations

Effective Date
01-Nov-2026

Buy Documents

Draft

oSIST prEN 50117-9-1:2021

English language (16 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 50117-9-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000 MHz". This standard covers: This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 and EN 50173 4:2018. This also includes the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for analogue and digital one and two way signal transmission, e.g. for cable networks for television signals, sound signals and interactive services in accordance with EN 60728 1:2014, EN 60728 1 1:2014, EN 60728 101:2017, EN 60728 10:2014, EN 50173 1:2018 and EN 50173 4:2018. This also includes the transmission of BCT signals provided by a CATV, MATV or SMATV cable network. The purpose of this document is to specify the applicable test methods and requirements for the electrical, mechanical and environmental characteristics and for fire performance of the cables.

SIST EN 50117-9-1:2026 is classified under the following ICS (International Classification for Standards) categories: 33.120.10 - Coaxial cables. Waveguides. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50117-9-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 50117-9-1:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50117-9-1:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 50117-9-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN 50117-9-1:2021
01-januar-2021
Koaksialni kabli - 9-1. del: Področna specifikacija za koaksialne kable za analogni
in digitalni prenos signala - Notranji priključni kabli za sisteme, ki delujejo v
območju od 5 MHz do 1000 MHz
Coaxial cables - Part 9-1: Sectional specification for coaxial cables for analogue and
digital signal transmission - Indoor drop cables for systems operating at 5 MHz - 1 000
MHz
Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale Kabel für analoge und
digitale Signalübertragung - Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire pour câbles coaxiaux pour la
transmission de signaux analogiques et numériques - Câbles de raccordement à usage
intérieur pour les systèmes fonctionnant entre 5 MHz et 1 000 MHz
Ta slovenski standard je istoveten z: prEN 50117-9-1
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
oSIST prEN 50117-9-1:2021 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN 50117-9-1:2021
oSIST prEN 50117-9-1:2021
EUROPEAN STANDARD DRAFT
prEN 50117-9-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2020
ICS  Will supersede EN 50117-9-1:2019 and all of its
amendments and corrigenda (if any)
English Version
Coaxial cables - Part 9-1: Sectional specification for coaxial
cables for analogue and digital signal transmission - Indoor drop
cables for systems operating at 5 MHz - 1 000 MHz
Câbles coaxiaux - Partie 9-1: Spécification intermédiaire Koaxiale Kabel - Teil 9-1: Rahmenspezifikation für koaxiale
pour câbles coaxiaux pour la transmission de signaux Kabel für analoge und digitale Signalübertragung -
analogiques et numériques - Câbles de raccordement à Innenkabel für Systeme im Bereich von 5 MHz - 1 000 MHz
usage intérieur pour les systèmes fonctionnant entre 5 MHz
et 1 000 MHz
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2021-02-19.

It has been drawn up by CLC/SC 46XA.

If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 69504 Ref. No. prEN 50117-9-1 E

oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Requirements for cable construction, design and installation . 5
4.1 General . 5
4.2 Inner conductor . 6
4.3 Dielectric. 6
4.4 Outer conductor or screen . 6
4.5 Filling compounds . 6
4.6 Moisture barriers . 6
4.7 Wrapping layers . 6
4.8 Sheath . 6
4.9 Metallic protection . 7
4.10 Cable integral suspension strand (Messenger wire) . 7
4.11 Oversheath . 7
4.12 Fauna proofing . 7
4.13 Chemical and/or environmental proofing . 7
4.14 Cable identification . 7
4.14.1 General . 7
4.14.2 Sheath marking . 7
4.15 Labelling . 7
5 Tests and requirements for completed cables . 8
5.1 General . 8
5.2 Electrical parameters and requirements . 8
5.2.1 Low-frequency and DC electrical parameters and requirements . 8
5.2.2 High-frequency electrical and transmission parameters and requirements . 8
5.3 Mechanical parameters and requirements . 10
5.4 Environmental parameters and requirements . 11
5.5 Fire performance test methods . 12
Annex A (informative) Cable types . 13
Annex ZZ (informative) Relationship between this European standard and the safety objectives
of Directive 2014/35/EU [2014 OJ L96] aimed to be covered . 14
Bibliography . 16

oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
European foreword
This document (prEN 50117-9-1:2020) has been prepared by CLC/SC 46XA “Coaxial cables” of
CLC/TC 46X “Communication cables”.
This document is currently submitted to the Enquiry.
The following dates are proposed:
• latest date by which the existence of (doa) dor + 6 months
this document has to be announced
at national level
• latest date by which this document has to be (dop) dor + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dor + 36 months
conflicting with this document have to (to be confirmed or
be withdrawn modified when voting)
This document will supersede EN 50117-9-1:2019 and all of its amendments and corrigenda (if any).
This document has been prepared under a mandate given to CENELEC by the European Commission and
the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with the EU Directive 2014/35/EU see informative Annex ZZ, which is an integral part of
this document.
This document covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for
Use within Certain Voltage Limits (LVD - 2014/35/EU).
All materials used for cables according to this document are expected to fulfil the requirements of the current
REACH Regulation and ROHS Directives.
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
1 Scope
This part of the EN 50117 series which is a sectional specification applies to coaxial indoor drop cables for
analogue and digital one and two way signal transmission, e.g. for cable networks for television signals,
sound signals and interactive services in accordance with EN 60728-1:2014, EN 60728-1-1:2014,
EN 60728-101:2017, EN 60728-10:2014, EN 50173-1:2018 and EN 50173-4:2018. This includes also the
transmission of BCT signals provided by a CATV, MATV or SMATV cable network.
The purpose of this document is to specify the applicable test methods and requirements for the electrical,
mechanical and environmental characteristics and for fire performance of the cables.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 50117-1:2019, Coaxial cables - Part 1: Generic specification
EN 50289-3-9:2001, Communication cables - Specifications for test methods - Part 3-9: Mechanical test
methods - Bending tests
EN 50290-1-2:2004, Communication cables - Part 1-2: Definitions
EN 50290-2-1:2005, Communication cables - Part 2-1: Common design rules and construction
EN 50290-2-22:2001, Communication cables - Part 2-22: Common design rules and construction - PVC
sheathing compounds
EN 50290-2-27:2002, Communication cables - Part 2-27: Common design rules and construction - Halogen
free flame retardant thermoplastic sheathing compounds
EN 50290-2-37:2016, Communication cables - Part 2-37: Common design rules and construction -
Polyethylene insulation for coaxial cables
EN 50290-2-38:2016, Communication cables - Part 2-38: Common design rules and construction -
Polypropylene insulation for coaxial cables
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects
EN 50290-4-2:2014, Communication cables - Part 4-2: General considerations for the use of cables - Guide
to use
EN 60728-1:2014, Cable networks for television signals, sound signals and interactive services - Part 1:
System performance of forward paths (IEC 60728-1:2014)
EN 62153-1-1:2004, Metallic communication cables test methods - Part 1-1: Electrical - Measurement of the
pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT)
(IEC 62153-1-1:2003)
IEC 61196-1-112:2006, Coaxial communication cables - Part 1-112: Electrical test methods - Test for return
loss (uniformity of impedance)
IEC 61196-1-115:2006, Coaxial communication cables - Part 1-115: Electrical test methods - Test for
regularity of impedance (pulse/step function return loss)
IEC 62153-4-3:2013, Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility
(EMC) - Surface transfer impedance - Triaxial method
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
IEC 62153-4-4:2015, Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility
(EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50290-1-2:2004, EN 50117-1:2019,
EN 60728-1:2014 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at http://www.electropedia.org/
3.1
drop cable
coaxial cable which is used to connect from:
a) subscriber tap or a directional coupler to a system outlet,
b) subscriber tap to a subscriber splitter,
c) subscriber splitter to a system outlet
3.2
indoor drop cable
drop cable for indoor application
4 Requirements for cable construction, design and installation
4.1 General
Cables according to this document are designed for an operating temperature range from −40 °C to
1)
+70 °C and at frequencies between 5 MHz and 1 000 MHz.
When designing the cable, consideration should be given to the maximum admissible current stated in the
detail specification. It is assumed that the raise of temperature of the inner conductor when submitted to the
maximum current under nominal ambient conditions does not affect the mechanical and electrical properties
of the cable.
Cables according to this document may be operated at voltages > 50 V AC or > 75 V DC according to the
detail specification of the manufacturer. However, these cables are not intended for direct connection to the
mains electricity supply or other low impedance sources.
Cables according to this document shall be designed and constructed according to EN 50290-2-1:2005,
Communication cables Part 2-1: Common design rules and construction and according to
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects Compliance with the essential requirements of the LVD is
described in subclause 4.2.2 of EN 50290-4-1 .
The use of cables according to this document including delivery, storage and installation shall be in
accordance with EN 50290-4-2:2014, Communication cables - Part 4-2: General considerations for the use
of cables - Guide to use, unless otherwise specified.

1) This value is valid for applications without ampacity only, see also Table A.1 concerning max. DC current.
2) EN 50290-4-1:2014, 4.2.2 requires the use raw materials according to EN 50290-2-xx series, design
according to EN 50290-2-1 and dielectric tests according to EN 50289-1-3 and to EN 50290-2-1. Voltage
withstanding tests shall be performed between conductors and between the conductors or screen and the
outer surface of the sheath.
oSIST prEN 50117-9-1:2021
prEN 50117-9-1:2020 (E)
When designed and constructed in accordance with EN 50290-2-1:2005 and EN 50117-1:2019 and
submitted to spark testing, (see 5.1.2.5 in Table 1), CATV cables according to this document may be
installed together with Low Voltage cables.
Moreover, the tests according to Clause 5 of this document shall be performed after environmental and
ageing tests. In addition, the raw materials of these cables are defined in the EN 50290 series.
This ensures sufficient stability of the cables related to this characteristic for its life cycle.
Thus these cables are considered safe when:
— they are used for their intended purpose and applications;
— they are used under voltages and currents that do not exceed the limits given in the relevant detail
specification.
All cables covered by this document do not fall under the scope of the RED or the EMC Directive.
Nevertheless, transfer impedance and screening attenuation according to 5.1.3.6 and 5.1.3.7 in Table 2 shall
be specified in the relevant detail specification, if the intended application of the cable is the use in
combination with equipment under the RED or the EMC Directive, see also EN 50290-4-1:2014, 4.2.1.
4.2 Inner conductor
The conductor shall meet the requirements of EN 50117-1:2019, 4.2 and shall be solid and may be plain or
metal coated. Dimensions shall be in accordance with the detail specification.
There shall be no joint made subsequent to the last drawing operation.
In case of metal coated conductor, consideration shall be taken for the compatibility of the connector.
4.3 Dielectric
The dielectric material(s) shall be in accordance with EN 50117-1:2019, 4.3 and shall consist of polyolefin
materials, with EN 50290-2-37:2016 (polyethylene), EN 50290-2-38:2016 (polypropylene). Dimensions shall
be in accordance with the detail specification.
Unless otherwise specified, the nominal diameter over the dielectric should be one of the preferred values,
namely 3,7 mm, 4,8 mm and 7,2 mm.
4.4 Outer conductor or screen
The construction and material of the outer conductor (or screen) shall meet the requirements of
EN 50117-1:2019, 4.4 items b), f) or g). Where option b) is used, a double braid layer is required.
For braid constructions or helically wound wires, the braid angle shall be between 15° and 45°. The coverage
factor shall be greater than or equal to 65 %, or, when the cab
...