Liquid petroleum products - Vapour pressure - Part 2: Determination of absolute pressure (AVP) between 40 oC and 100 oC

This European Standard specifies a method for the determination of absolute vapour pressure of liquid petroleum products at elevated temperatures.
The conditions used in the test described in this standard are a vapour to liquid ratio of 3:2 and an initial injection temperature of 37,8 °C or 30,0 °C.
The method described is suitable for testing air-saturated samples that exert an air-saturated vapour pressure of between 9 kPa and 500 kPa at temperatures between 40 °C and 100 °C.
This European Standard is applicable to fuels containing oxygenated compounds up to the limits stated in the relevant EC Directive 85/536/EEC [3].
NOTE 1   If a sample injection is into a test chamber which is raised to 37,8 °C and the vapour to liquid ratio is 4:1, the initial measurement corresponds with the measurement in Part 1 of this standard.
NOTE 2   For the purposes of this European Standard, the term % (V/V) is used to represent the volume fraction.
WARNING - Use of this standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

Flüssige Mineralölerzeugnisse - Dampfdruck - Teil 2: Bestimmung des absoluten Dampfdruckes (AVP) im Temperaturbereich zwischen 40 C und 100 C

Diese Europäische Norm legt ein Verfahren fest zur Messung des absoluten Dampfdrucks von flüssigen Mineralölerzeugnissen bei erhöhten Temperaturen.
Die in dieser Norm beschriebenen Prüfbedingungen beziehen sich auf ein Dampf-Flüssigkeitsverhältnis von 3:2 und eine anfängliche Einspritztemperatur von 37,8 °C oder 30,0 °C.
Das beschriebene Verfahren ist geeignet zur Prüfung von luftgesättigten Proben, die einen luftgesättigten absoluten Dampfdruck zwischen 9 kPa und 500 kPa bei Temperaturen zwischen 40 °C und 100 °C besitzen.
Diese Europäische Norm ist anwendbar auf Kraftstoffe, die sauerstoffhaltige Komponenten bis hin zu der in der relevanten EG-Richtlinie 85/536/EWG [3] angegebenen Grenze enthalten.
ANMERKUNG 1   Wenn die Probeninjektion bei einer Messkammer¬temperatur von 37,8 °C vorgenommen wird und das Verhältnis von Dampf zu Flüssigkeit 4:1 beträgt, entspricht die vorgenommene Anfangsmessung dem Dampfdruck, wie er mit Teil 1 dieser Norm bestimmt wurde.
ANMERKUNG 2   Für deie Anwendung dieser Norm wird der Ausdruck „% (V/V)“ für „Volumenanteil in %“¬ verwendet.
WARNUNG — Die Anwendung dieser Europäischen Norm kann den Einsatz gefährlicher Stoffe, Arbeitsgänge und Geräte mit sich bringen. Diese Norm gibt nicht vor, alle mit ihrer Anwendung verbundenen Sicherheitsprobleme anzusprechen. Der Anwender dieser Norm ist dafür verantwortlich, vorher angemessene Maßnahmen zu ergreifen und die Anwendbarkeit einschränkender Vorschriften zu ermitteln.

Produits pétroliers liquides - Pression de vapeur - Partie 2 : Détermination de la pression de vapeur absolue (PVA) entre 40 C et 100 C

Tekoči naftni proizvodi – Parni tlak – 2. del: Določevanje absolutnega parnega tlaka (AVP) med 40 °C in 100 °C

General Information

Status
Published
Publication Date
24-Oct-2007
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Oct-2007
Due Date
09-Dec-2007
Completion Date
25-Oct-2007

Relations

Buy Standard

Standard
EN 13016-2:2007
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Liquid petroleum products - Vapour pressure - Part 2: Determination of absolute pressure (AVP) between 40 oC and 100 oCProduits pétroliers liquides - Pression de vapeur - Partie 2 : Détermination de la pression de vapeur absolue (PVA) entre 40
C et 100
CFlüssige Mineralölerzeugnisse - Dampfdruck - Teil 2: Bestimmung des absoluten Dampfdruckes (AVP) im Temperaturbereich zwischen 40
C
und 100
CTa slovenski standard je istoveten z:EN 13016-2:2007SIST EN 13016-2:2007en,fr,de75.160.20Liquid fuelsICS:SIST EN 13016-2:20001DGRPHãþDSLOVENSKI
STANDARDSIST EN 13016-2:200701-december-2007







EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13016-2
September 2007 ICS 75.160.20 Supersedes EN 13016-2:2000 English Version
Liquid petroleum products - Vapour pressure - Part 2: Determination of absolute pressure(AVP) between 40 °C and 100 °C
Produits pétroliers liquides - Pression de vapeur -Partie 2 : Détermination de la pression de vapeur absolue (PVA) entre 40 °C et 100 °C
Flüssige Mineralölerzeugnisse - Dampfdruck - Teil 2: Bestimmung des absoluten Dampfdruckes (AVP) im Temperaturbereich zwischen 40 °C und 100 °C This European Standard was approved by CEN on 28 July 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13016-2:2007: E



EN 13016-2:2007 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.5 2 Normative references.5 3 Terms and definitions.5 4 Principle.5 5 Reagents.6 6 Apparatus.6 7 Sampling.7 8 Sample preparation.7 9 Preparation of apparatus.8 10 Calibration of apparatus.8 10.1 Pressure transducer.8 10.2 Temperature measuring device.9 11 Verification of apparatus.9 12 Procedure.9 13 Calculation.10 14 Expression of results.10 15 Precision.11 15.1 Repeatability, r.11 15.2 Reproducibility, R.11 16 Test report.11 Annex A (informative)
Derivation of equations used to calculate AVP.12 A.1 Theory.12 A.2 Derivation of equation.12 A.3 Air correction at test temperature.13 A.4 Calculation.13 Bibliography.14



EN 13016-2:2007 (E) 3 Foreword This document (EN 13016-2:2007) has been prepared by Technical Committee CEN/TC 19 “Gaseous and liquid fuels, lubricants and related products of petroleum, synthetic and biological origin”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2008, and conflicting national standards shall be withdrawn at the latest by March 2008. This document supersedes EN 13016-2:2000, which has been revised editorially to clarify a number of steps related to sampling, calibration of the pressure transducer and the procedure. No new precision evaluations have been carried out. The equation to calculate the absolute vapour pressure in the informative Annex A has been corrected. EN 13016 consists of the following parts, under the general title Liquid petroleum products - Vapour pressure:  Part 1: Determination of air-saturated vapour pressure (ASVP) and calculated dry vapour pressure equivalent (DVPE).  Part 2: Determination of absolute vapour pressure (AVP) between 40 °C and 100 °C. Part 1 is based on and developed in parallel with IP 394 [1] and ASTM D 5191 [2]. It describes a general determination method, whereas this part describes one at elevated temperatures. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard : Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 13016-2:2007 (E) 4 Introduction Vapour pressure is used as a classification criterion for the safe handling and carriage of petroleum products, feedstocks and components; it has a relationship to the potential for hydrocarbon emissions, under uncontrolled conditions, and thus is the subject of environmental scrutiny. Vapour pressure limitations are often imposed to prevent pump cavitation during transfer operations. Vapour pressure is one measure of the volatility characteristics of fuels used in many differing types of engines with large variations in operating temperatures. Fuels having a high vapour pressure may vaporize too readily in the fuel handling systems, resulting in decreased flow to the engine and possible stoppage by vapour lock. Conversely, fuels of low vapour pressure may not vaporize readily enough, resulting in difficult starting, slow warm-up and poor acceleration.



EN 13016-2:2007 (E) 5 1 Scope This European Standard specifies a method for the determination of absolute vapour pressure of liquid petroleum products at elevated temperatures. The conditions used in the test described in this standard are a vapour to liquid ratio of 3:2 and an initial injection temperature of 37,8 °C or 30,0 °C. The method described is suitable for testing air-saturated samples that exert an air-saturated vapour pressure of between 9 kPa and 500 kPa at temperatures between 40 °C and 100 °C.
This European Standard is applicable to fuels containing oxygenated compounds up to the limits stated in the relevant EC Directive 85/536/EEC [3]. NOTE 1 If a sample injection is into a test chamber which is raised to 37,8 °C and the vapour to liquid ratio is 4:1, the initial measurement corresponds with the measurement in Part 1 of this standard. NOTE 2 For the purposes of this European Standard, the term “% (V/V)” is used to represent the volume fraction. WARNING — Use of this standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN ISO 3170, Petroleum liquids - Manual sampling (ISO 3170:2004) 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 air-saturated vapour pressure total pressure ASVP observed pressure exerted in vacuo by the partial pressure of air-saturated petroleum products, components and feedstocks, in the absence of non-dissolved water, and the partial pressure of the dissolved air 3.2 absolute vapour pressure AVP air-saturated vapour pressure minus the partial pressure due to dissolved air in the liquid 4 Principle A cooled air-saturated sample of known volume is introduced into an evacuated, temperature-controlled chamber in two equal test portions. The volume of the chamber is five times that of the sample introduced to provide a vapour-to-liquid ratio of 4:1.
The vapour-to-liquid ratio following the second injection is 3:2.
After



EN 13016-2:2007 (E) 6 the injection of each test portion, the air-saturated vapour pressure is determined. The partial pressure of the dissolved air is calculated from the two resulting pressures. The temperature of the test chamber is then increased to a specified value and the air-saturated vapour pressure determined. The absolute vapour pressure (AVP) is calculated by subtracting the partial pressure of the dissolved air in the liquid, which has been corrected for temperature and compensated for compressive effects and solubility, from the air-saturated vapour pressure. The procedure may be repeated at further test temperatures. 5 Reagents Pentane, reagent grade 99,5 % (V/V) minimum purity. 6 Apparatus 6.1 Instrument 6.1.1 The instrument shall conform to the general requirements given in 6.1.2 to 6.1.6. NOTE Full details of suitable instruments are not given because of differences in the way that the basic principles are applied by individual manufacturers. The instrument shall be installed, operated and maintained in accordance with the manufacturer's manual. 6.1.2 The system shall be configured to enable the test chamber to be evacuated and isolated, the sample to be drained, and the system flushed and purged as necessary. 6.1.3 The test chamber shall be vacuum-tight, with provision for the introduction of the sample, and shall be capable of containing between 5 ml and 15 ml of liquid and vapour with an accuracy of 1 %. The test chamber shall be capable of controlling the temperature of the sample to achieve the specified test temperature to within ± 0,1 °C and of indicating the temperature to a resolution of at least 0,1 °C. NOTE 1 The test chambers used in the instruments that generated the precision statements were constructed from either aluminum or stainless steel.
NOTE 2 Test chambers with capacities less than 5 ml or greater than 15 ml may be used but the precision of the method can be affected. 6.1.4 The apparatus shall be capable of measuring the vapour pressure of small samples of petroleum products, components and feedstocks over the pressure range 9,0 kPa to 500,0 kPa and at temperatures between 40 °C and 100 °C, by means of a pressure transducer, with an accuracy of 0,8 kPa and a resolution of 0,1 kPa. 6.1.5 If a vacuum pump is required for use with the instrument, it shall be capable of reducing the pressure in the test chamber to less than 0,01 kPa absolute. 6.1.6 If a vacuum-tight syringe or similar equipment is required for measuring or injecting the required volume of sample into the test chamber, it shall be sized appropriately to the required sample size with an accuracy of at least 1 %. 6.2 Cooling equipment, air or iced-water bath or a refrigerator, capable of cooling the samples to a temperature of between 0 °C and 1 °C. NOTE A suitably safe refrigerator should be used with highly volatile petroleum products. 6.3 Barometer for calibration, capable of measuring atmospheric pressure within an accuracy of 0,1 kPa or better and calibrated and/or verified against an instrument certified by an authorized certification body.



EN 13016-2:2007 (E) 7 6.4 Vacuum gauge for calibration, covering at least the range 0 kPa to 177 kPa, calibrated and/or verified against an instrument certified by an authorized certification body. 6.5 Pressure measuring device for the apparatus, having a minimum measuring range from 0 kPa to 500 kPa, calibrated and/or verified against an instrument certified by an authorized certification body. 7 Sampling 7.1 Due to the extreme sensitivity of vapour pressure measurements to losses through evapora
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.