Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests

This part of IEC 61672 provides details of the tests necessary to verify conformance to all mandatory specifications given in IEC 61672-1 for time-weighting sound level meters, integrating-averaging sound level meters, and integrating sound level meters. Patternevaluation tests apply for each channel of a multi-channel sound level meter, as necessary. Tests and test methods are applicable to class 1 and class 2 sound level meters. The aim is to ensure that all laboratories use consistent methods to perform pattern-evaluation tests.

Elektroakustik - Schallpegelmesser - Teil 2: Baumusterprüfungen

Electroacoustique - Sonomètres - Partie 2: Essais d'évaluation d'un modèle

La CEI 61672-2:2013 donne des détails concernant les essais nécessaires pour vérifier la conformité à toutes les spécifications obligatoires données dans la CEI 61672-1 pour les sonomètres à pondération temporelle, les sonomètres intégrateurs-moyenneurs, et les sonomètres intégrateurs. Les essais d'évaluation d'un modèle s'appliquent, si nécessaire, à chaque canal d'un sonomètre à plusieurs canaux. Les essais et les méthodes d'essai sont applicables aux sonomètres de classe 1 et de classe 2. Le but est de s'assurer que tous les laboratoires utilisent des méthodes cohérentes pour effectuer les essais d'évaluation d'un modèle. Cette seconde édition annule et remplace la première édition parue en 2003. Elle constitue une révision technique qui inclut des modifications techniques majeures concernant démonstration de la conformité aux spécifications. Elle est maintenant démontrée lorsque les écarts mesurés par rapport aux valeurs nominales ne dépassent pas les limites d'acceptation applicables, et lorsque l'incertitude de mesure ne dépasse pas l'incertitude maximale autorisée correspondante, les deux incertitudes étant déterminées pour une probabilité de couverture de 95 %. Dans ce document, les références aux CEI 61672-1, CEI 61672-2, et CEI 61672-3 s'entendent pour les deuxièmes éditions, sauf indication contraire. Les procédures pour réaliser les essais d'évaluation d'un modèle de sonomètres conçus pour être conformes aux spécifications de la CEI 61672-1:2002 ont été données dans la CEI 61672-2:2003.

Elektroakustika - Merilniki zvočne jakosti - 2. del: Preskusi z ocenjevanjem vzorcev (IEC 61672-2:2013)

Ta del standarda IEC 61672 navaja podrobnosti glede preskusov, potrebnih za preverjanje skladnosti z vsemi obveznimi specifikacijami, podanimi v standardu IEC 61672-1 za merilnike časovno vrednotene zvočne jakosti, zvokomere z integracijskim povprečenjem in merilnike integracijske zvočne jakosti. Preskusi z ocenjevanjem vzorcev se po potrebi uporabijo za vsak kanal večkanalnega merilnika zvočne jakosti. Preskusi in preskusne metode se uporabljajo za merilnike zvočne jakosti razreda 1 in 2. Cilj je zagotoviti uporabo skladnih metod pri preskušanju z ocenjevanjem vzorcev v vseh laboratorijih.

General Information

Status
Published
Publication Date
23-Jan-2014
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
13-Jan-2014
Due Date
20-Mar-2014
Completion Date
24-Jan-2014

Relations

Buy Standard

Standard
EN 61672-2:2014
English language
42 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61672-2:2014
01-marec-2014
1DGRPHãþD
SIST EN 61672-2:2004
(OHNWURDNXVWLND0HULOQLNL]YRþQHMDNRVWLGHO3UHVNXVL]RFHQMHYDQMHPY]RUFHY
,(&
Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
Elektroakustik - Schallpegelmesser - Teil 2: Baumusterprüfungen
Electroacoustique - Sonomètres - Partie 2: Essais d'évaluation d'un modèle
Ta slovenski standard je istoveten z: EN 61672-2:2013
ICS:
17.140.50 Elektroakustika Electroacoustics
SIST EN 61672-2:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61672-2:2014

---------------------- Page: 2 ----------------------

SIST EN 61672-2:2014

EUROPEAN STANDARD
EN 61672-2

NORME EUROPÉENNE
December 2013
EUROPÄISCHE NORM

ICS 17.140.50 Supersedes EN 61672-2:2003


English version


Electroacoustics -
Sound level meters -
Part 2: Pattern evaluation tests
(IEC 61672-2:2013)


Electroacoustique -  Elektroakustik -
Sonomètres - Schallpegelmesser -
Partie 2: Essais d'évaluation d'un modèle Teil 2: Baumusterprüfungen
(CEI 61672-2:2013) (IEC 61672-2:2013)





This European Standard was approved by CENELEC on 2013-11-04. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61672-2:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61672-2:2014
EN 61672-2:2013 - 2 -
Foreword
The text of document 29/813/FDIS, future edition 2 of IEC 61672-2, prepared by IEC/TC 29
"Electroacoustics" in cooperation with the International Organization of Legal Metrology (OIML), was
submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61672-2:2013.
The following dates are fixed:
– latest date by which the document has to be implemented at (dop) 2014-08-04
national level by publication of an identical national
standard or by endorsement
– latest date by which the national standards conflicting with (dow) 2016-11-04
the document have to be withdrawn

This document supersedes EN 61672-2:2003.
EN 61672-2:2013 includes the following significant technical changes with respect to
EN 61672-2:2003.
In this second edition, conformance to specifications is demonstrated when
a) measured deviations from design goals do not exceed the applicable acceptance limits, and
b) the uncertainty of measurement does not exceed the corresponding maximum permitted
uncertainty, with both uncertainties determined for a coverage probability of 95 %.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61672-2:2013 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated :
IEC 61094-8 NOTE Harmonized as EN 61094-8.

---------------------- Page: 4 ----------------------

SIST EN 61672-2:2014
- 3 - EN 61672-2:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE  When an international publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.

Publication Year Title EN/HD Year
IEC 60942 - Electroacoustics - Sound calibrators EN 60942 -
IEC 61000-4-2 2008 Electromagnetic compatibility (EMC) EN 61000-4-2 2009
Part 4-2: Testing and measurement
techniques - Electrostatic discharge
immunity test
IEC 61000-4-3 2006 Electromagnetic compatibility (EMC) EN 61000-4-3 2006
+ A1 2007 Part 4-3: Testing and measurement + A1 2008
+ A2 2010 techniques - Radiated, radio-frequency, + A2 2010
electromagnetic field immunity test
IEC 61000-4-6 2008 Electromagnetic compatibility (EMC) EN 61000-4-6 2009
Part 4-6: Testing and measurement
techniques - Immunity to conducted
disturbances, induced by radio-frequency
fields
IEC 61000-6-2 2005 Electromagnetic compatibility (EMC) EN 61000-6-2 2005
Part 6-2: Generic standards - Immunity for + corr. September 2005
industrial environments
IEC 61094-1 - Measurement microphones EN 61094-1 -
Part 1: Specifications for laboratory
standard microphones
IEC 61094-5 - Measurement microphones EN 61094-5 -
Part 5: Methods for pressure calibration of
working standard microphones by
comparison
IEC 61183 - Electroacoustics - Random-incidence and EN 61183 -
diffuse-field calibration of sound level
meters
IEC 61672-1 - Electroacoustics - Sound level meters EN 61672-1 -
Part 1: Specifications
IEC 62585 - Electroacoustics - Methods to determine EN 62585 -
corrections to obtain the free-field
response of a sound level meter

---------------------- Page: 5 ----------------------

SIST EN 61672-2:2014
EN 61672-2:2013 - 4 -
Publication Year Title EN/HD Year
CISPR 16-1-1 - Specification for radio disturbance and EN 55016-1-1 -
immunity measuring apparatus and
methods
Part 1-1: Radio disturbance and immunity
measuring apparatus - Measuring
apparatus
CISPR 16-1-2 2003 Specification for radio disturbance and EN 55016-1-2 2004
+ corr. January 2009 immunity measuring apparatus and - -
+ A1 2004 methods + A1 2005
+ A2 2006 Part 1-2: Radio disturbance and immunity + A2 2006
measuring apparatus - Ancillary
equipment - Conducted disturbances
CISPR 16-2-1 2008 Specification for radio disturbance and EN 55016-2-1 2009
+ A1 2010 immunity measuring apparatus and + A1 2011
methods
Part 2-1: Methods of measurement of
disturbances and immunity - Conducted
disturbance measurements
CISPR 16-2-3 2010 Specification for radio disturbance and EN 55016-2-3 2010
- - immunity measuring apparatus and + AC:2013 2013
+ A1 2010 methods + A1 2010
Part 2-3: Methods of measurement of
disturbances and immunity - Radiated
disturbance measurements
CISPR 22 (mod) 2008 Information technology equipment - Radio EN 55022 2010
1)
disturbance characteristics - Limits and + AC:2011 2011
methods of measurement
ISO/IEC Guide 98-3 - Uncertainty of measurement - -
Part 3: Guide to the expression of
uncertainty in measurement (GUM:1995)
ISO/IEC Guide 99 - International vocabulary of metrology - - -
Basic and general concepts and
associated terms (VIM)
ISO 26101 2012 Acoustics - Test methods for the - -
qualification of free-field environments


1) EN 55022 is superseded by EN 55032:2012, which is based on CISPR 32:2012 + corr. Mars 2012 +
corr. August 2012 .

---------------------- Page: 6 ----------------------

SIST EN 61672-2:2014



IEC 61672-2

®


Edition 2.0 2013-09




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Electroacoustics – Sound level meters –

Part 2: Pattern evaluation tests




Electroacoustique – Sonomètres –

Partie 2: Essais d'évaluation d'un modèle
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX W


ICS 17.140.50 ISBN 978-2-8322-1080-2



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61672-2:2014
– 2 – 61672-2 © IEC:2013
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 Submission for testing . 7
5 Marking of the sound level meter and information in the Instruction Manual . 8
6 Mandatory facilities and general requirements . 8
7 Environmental, electrostatic, and radio-frequency tests . 10
7.1 General . 10
7.2 Uncertainties for measurements of environmental test conditions . 11
7.3 Influence of static pressure . 11
7.4 Limits on air temperature, relative humidity and static pressure . 12
7.5 Acclimatization requirements for tests of the influence of air temperature and
relative humidity . 12
7.6 Abbreviated test of the combined influence of air temperature and relative
humidity . 12
7.7 Influence of air temperature . 14
7.8 Influence of relative humidity . 15
7.9 Influence of electrostatic discharges . 16
7.10 Influence of a.c. power-frequency and radio-frequency fields. 17
7.10.1 Sound signal . 17
7.10.2 AC power-frequency tests . 17
7.10.3 Radio-frequency tests . 17
8 Radio-frequency emissions and public power supply disturbances. 19
9 Electroacoustical performance tests . 20
9.1 General . 20
9.2 Indication at the calibration check frequency . 21
9.3 Directional response . 21
9.4 Tests of frequency weightings with acoustical signals . 23
9.4.1 General . 23
9.4.2 Windscreen corrections . 24
9.4.3 Free-field tests . 24
9.4.4 Comparison coupler tests . 25
9.4.5 Conformance . 26
9.4.6 Random incidence . 26
9.5 Tests of frequency weightings with electrical signals . 27
9.5.1 General . 27
9.5.2 First alternative test procedure (variable input signal level). 27
9.5.3 Second alternative test procedure (constant input signal level) . 27
9.5.4 Conformance . 28
9.5.5 Frequency weightings C or Z at 1 kHz . 28
9.6 Corrections for the effect of reflections from the case of a sound level meter
and diffraction around a microphone . 28
9.7 Corrections to obtain free-field or random-incidence sound levels . 29
9.8 Level linearity . 30
9.8.1 Tests at an air temperature near the reference air temperature . 30
9.8.2 Tests at elevated air temperature . 31

---------------------- Page: 8 ----------------------

SIST EN 61672-2:2014
61672-2 © IEC:2013 – 3 –
9.9 Under-range indication . 31
9.10 Self-generated noise level . 31
9.11 Decay time constants for time weightings F and S . 32
9.12 Toneburst response for sound level meters that measure time-weighted
sound level . 32
9.13 Toneburst response for sound level meters that measure sound exposure
level or time-averaged sound level . 33
9.14 Response to sequences of repeated tonebursts for sound level meters that
measure time-averaged sound level . 34
9.15 Overload indication . 34
9.16 C-weighted peak sound level . 35
9.17 Reset . 36
9.18 Electrical output . 36
9.19 Timing facilities . 36
9.20 Crosstalk in multi-channel sound level meter systems . 36
9.21 Power supply . 36
10 Pattern evaluation report . 37
Bibliography . 38

---------------------- Page: 9 ----------------------

SIST EN 61672-2:2014
– 4 – 61672-2 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

ELECTROACOUSTICS –
SOUND LEVEL METERS –

Part 2: Pattern evaluation tests

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61672-2 has been prepared by IEC technical committee 29,
Electroacoustics, in cooperation with the International Organization of Legal Metrology
(OIML).
This second edition cancels and replaces the first edition published in 2003. This second
edition constitutes a technical revision.
The main technical changes with regard to the previous edition are as follows:
In this second edition, conformance to specifications is demonstrated when:
a) measured deviations from design goals do not exceed the applicable acceptance limits,
and
b) the uncertainty of measurement does not exceed the corresponding maximum permitted
uncertainty, with both uncertainties determined for a coverage probability of 95 %.

---------------------- Page: 10 ----------------------

SIST EN 61672-2:2014
61672-2 © IEC:2013 – 5 –
The text of this second edition is based on that of the first edition and the following
documents:
FDIS Report on voting
29/813/FDIS 29/824/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61672 series, published under the general title Electroacoustics –
Sound level meters, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN 61672-2:2014
– 6 – 61672-2 © IEC:2013
ELECTROACOUSTICS –
SOUND LEVEL METERS –

Part 2: Pattern-evaluation tests



1 Scope
This part of IEC 61672 provides details of the tests necessary to verify conformance to all
mandatory specifications given in IEC 61672-1 for time-weighting sound level meters,
integrating-averaging sound level meters, and integrating sound level meters. Pattern-
evaluation tests apply for each channel of a multi-channel sound level meter, as necessary.
Tests and test methods are applicable to class 1 and class 2 sound level meters. The aim is
to ensure that all laboratories use consistent methods to perform pattern-evaluation tests.
NOTE 1 In this document, references to IEC 61672-1, IEC 61672-2, and IEC 61672-3 refer to the second editions
unless stated otherwise.
NOTE 2 Procedures for the pattern-evaluation testing of sound level meters designed to conform to the
specifications of IEC 61672-1:2002 were given in IEC 61672-2:2003.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60942, Electroacoustics – Sound calibrators
IEC 61000-4-2:2008, Electromagnetic compatibility (EMC) – Part 4-2: Testing and
measurement techniques – Electrostatic discharge immunity test
IEC 61000-4-3:2010, Electromagnetic compatibility (EMC) – Part 4-3: Testing and
measurement techniques – Radiated, radio-frequency, electromagnetic-field immunity test
IEC 61000-4-6:2008, Electromagnetic compatibility (EMC) – Part 4-6: Testing and
measurement techniques – Immunity to conducted disturbances, induced by radio-frequency
fields
IEC 61000-6-2:2005, Electromagnetic compatibility (EMC) – Part 6-2: Generic standards –
Immunity for industrial environments
IEC 61094-1, Measurement microphones – Part 1: Specifications for laboratory standard
microphones
IEC 61094-5, Measurement microphones – Part 5: Methods for pressure calibration of working
standard microphones by comparison
IEC 61183, Electroacoustics – Random-incidence and diffuse-field calibration of sound level
meters
IEC 61672-1, Electroacoustics – Sound level meters – Part 1: Specifications

---------------------- Page: 12 ----------------------

SIST EN 61672-2:2014
61672-2 © IEC:2013 – 7 –
IEC 62585, Electroacoustics – Methods to determine corrections to obtain the free-field
response of a sound level meter
CISPR 16-1-1, Specification for radio disturbance and immunity measuring apparatus and
methods – Part 1-1: Radio disturbance and immunity measuring apparatus – Measuring
1
apparatus
CISPR 16-1-2:2006, Specification for radio disturbance and immunity measuring apparatus
and methods – Part 1-2: Radio disturbance and immunity measuring apparatus – Ancillary
equipment – Conducted disturbances
CISPR 16-2-1:2010 (Ed. 2.1), Specification for radio disturbance and immunity measuring
apparatus and methods – Part 2-1: Methods of measurement of disturbances and immunity –
Conducted disturbance measurements
CISPR 16-2-3:2010 (Ed. 3.1), Specification for radio disturbance and immunity measuring
apparatus and methods – Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements
CISPR 22:2008, Information technology equipment – Radio disturbance characteristics –
Limits and methods of measurement
ISO/IEC Guide 98-3, Uncertainty of measurement – Part 3: Guide to the expression of
uncertainty in measurement (GUM: 1995)
ISO/IEC Guide 99, International vocabulary of metrology – Basic and general concepts and
associated terms (VIM)
ISO 26101:2012, Acoustics – Test methods for the qualification of free-field environments
3 Terms and definitions
For the purposes of this document, in addition to the terms and definitions given in
IEC 61672-1 and IEC 62585, the terms and definitions given in IEC 61000-4-2,
IEC 61000-4-3, IEC 61000-4-6, ISO/IEC Guide 98-3, and ISO/IEC Guide 99 also apply.
4 Submission for testing
4.1 At least three specimens of the same pattern of sound level meter shall be submitted
for pattern-evaluation testing. As a minimum, the laboratory shall select two of the specimens
for testing. At least one of the two specimens shall then be tested fully according to the
procedures of this Standard. The laboratory shall decide whether the full tests shall also be
performed on the second specimen or whether additional limited testing is adequate to
approve the pattern.
4.2 An Instruction Manual and all items or accessories that are identified in the Instruction
Manual as integral components for the normal mode of operation shall be submitted along
with the three sound level meters. Examples of additional items or accessories include a
microphone extension device or cable and peripheral equipment.
4.3 If the manufacturer of the sound level meter supplies devices that are to be connected
to the sound level meter by cables, then the devices and cables shall be submitted with the
sound level meter.
—————————
1
In English, CISPR stands for International Special Committee on Radio Interference.

---------------------- Page: 13 ----------------------

SIST EN 61672-2:2014
– 8 – 61672-2 © IEC:2013
4.4 A calibrated sound calibrator of a model specified in the Instruction Manual for the
sound level meter shall be supplied with the sound level meter. An Instruction Manual for the
sound calibrator shall also be provided. As required by IEC 61672-1, the model of the
calibrator shall conform to the relevant specifications of IEC 60942 for the class of sound
calibrator.
5 Marking of the sound level meter and information in the Instruction Manual
5.1 It shall be verified that the sound level meter is marked according to the requirements
of IEC 61672-1.
5.2 It shall be verified that the Instruction Manual contains all the information that is
required by IEC 61672-1, as relevant to the facilities provided by the sound level meter.
5.3 If the sound level meter does not conform to the requirements of 5.1 and 5.2, no
pattern-evaluation tests shall be performed.
5.4 After completion of all tests, the information shall be reviewed to ensure that it is
correct and that no applicable acceptance limits are exceeded.
6 Mandatory facilities and general requirements
6.1 No test specified in this part of IEC 61672 shall be omitted unless the sound level
meter does not possess the facility described for the test. When the design of a sound level
meter, which has been pattern approved, is changed and a new pattern approval is requested,
then, at the discretion of the laboratory, it is not necessary to repeat those tests for
electroacoustical performance characteristics that are not affected by the design change.
6.2 A time-weighting sound level meter shall be verified to be able to display A-frequency-
weighted, F-time-weighted sound level and to be able to indicate overload and under-range
conditions.
6.3 An integrating-averaging sound level meter shall be verified to be able to display A-
frequency-weighted, time-averaged sound level and to be able to indicate overload and
under-range conditions.
6.4 An integrating sound level meter shall be verified to be able to display A-frequency-
weighted sound exposure level and to be able to indicate overload and under-range
conditions.
6.5 All display devices for the sound level meter shall be verified to be able to display
sound levels or sound exposure levels with the resolution required by IEC 61672
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.