Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

This part of CISPR 16 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der gestrahlten Störaussendung

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnées

Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti - 2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih motenj- Dodatek A1

Ta del CISPR 16 opredeljuje meotde za merjenje pojava sevanih motenj v frekvenčnem razponu od 9 kHz do 18 GHz.

General Information

Status
Withdrawn
Public Enquiry End Date
27-Feb-2010
Publication Date
08-Nov-2010
Withdrawal Date
09-Apr-2020
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
08-Apr-2020
Due Date
01-May-2020
Completion Date
10-Apr-2020

Relations

Buy Standard

Amendment
EN 55016-2-3:2010/A1:2010
English language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 55016-2-3:2010/A1:2010
01-december-2010
Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti -
2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih
motenj- Dodatek A1
Specification for radio disturbance and immunity measuring apparatus and methods -
Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance
measurements
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und
Störfestigkeit - Messung der gestrahlten Störaussendung
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 2-3:
Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations
rayonnées
Ta slovenski standard je istoveten z: EN 55016-2-3:2010/A1:2010
ICS:
17.240 Merjenje sevanja Radiation measurements
33.100.20 Imunost Immunity
SIST EN 55016-2-3:2010/A1:2010 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 55016-2-3:2010/A1:2010

---------------------- Page: 2 ----------------------

SIST EN 55016-2-3:2010/A1:2010

EUROPEAN STANDARD
EN 55016-2-3/A1

NORME EUROPÉENNE
October 2010
EUROPÄISCHE NORM

ICS 33.100.10; 33.100.20


English version


Specification for radio disturbance and immunity measuring apparatus
and methods -
Part 2-3: Methods of measurement of disturbances and immunity -
Radiated disturbance measurements
(CISPR 16-2-3:2010/A1:2010)


Spécifications des méthodes et des Anforderungen an Geräte und
appareils de mesure des perturbations Einrichtungen sowie Festlegung der
radioélectriques et de l'immunité aux Verfahren zur Messung der
perturbations radioélectriques - hochfrequenten Störaussendung
Partie 2-3: Méthodes de mesure des (Funkstörungen) und Störfestigkeit -
perturbations et de l'immunité - Teil 2-3: Verfahren zur Messung der
Mesures des perturbations rayonnées hochfrequenten Störaussendung
(CISPR 16-2-3:2010/A1:2010) (Funkstörungen) und Störfestigkeit -
Messung der gestrahlten Störaussendung
(CISPR 16-2-3:2010/A1:2010)


This amendment A1 modifies the European Standard EN 55016-2-3:2010; it was approved by CENELEC on
2010-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55016-2-3:2010/A1:2010 E

---------------------- Page: 3 ----------------------

SIST EN 55016-2-3:2010/A1:2010
EN 55016-2-3:2010/A1:2010 - 2 -
Foreword
The text of document CISPR/A/878/CDV, future amendment 1 to CISPR 16-2-3:2010, prepared by
CISPR SC A, Radio-interference measurements and statistical methods, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 55016-2-3:2010
on 2010-10-01.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2011-07-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2013-10-01
__________
Endorsement notice
The text of amendment 1:2010 to the International Standard IEC 55016-2-3:2010 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 55016-2-3:2010/A1:2010
CISPR 16-2-3
®
Edition 3.0 2010-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
AMENDMENT 1
AMENDEMENT 1
Specification for radio disturbance and immunity measuring apparatus and
methods –
Part 2-3: Methods of measurement of disturbances and immunity – Radiated
disturbance measurements

Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l’immunité aux perturbations radioélectriques –
Partie 2-3: Méthodes de mesure des perturbations et de l'immunité – Mesures
des perturbations rayonnées

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
H
CODE PRIX
ICS 33.100.10; 33.100.20 ISBN 978-2-88912-012-3
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 5 ----------------------

SIST EN 55016-2-3:2010/A1:2010
– 2 – CISPR 16-2-3 Amend. 1 © IEC:2010
FOREWORD
This amendment has been prepared by CISPR subcommittee A: Radio-interference
measurements and statistical methods, in cooperation with CISPR subcommittee D:
Electromagnetic disturbances related to electric/electronic equipment on vehicles and internal
combustion engine powered devices, of IEC technical committee CISPR: International special
committee on radio interference.
The text of this amendment is based on the following documents:
Enquiry draft Report on voting
CISPR/A/878/CDV CISPR/A/894/RVC

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

_____________

INTRODUCTION
The recent addition of FFT-based measuring instrumentation in CISPR 16-1-1 necessitates
the addition of related specifications for the test methods covered in CISPR 16-2-3. Those
new specifications are introduced in this amendment.
3 Terms and definitions
3.18
measuring receiver
Replace the existing definition by the follow
...

Questions, Comments and Discussion